DOE G 441.1-1C, Radiation Protection Programs Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection
Functional areas: Defense Nuclear Facility Safety and Health Requirement, Packaging and Transportation, Radiation Protection
Provides guidance for implementing the provisions of the functional areas contained in 10 CFR 835. The revision to the guide reflects changes in the June 2007 amendment to 10 CFR 835, Worker Safety and Health Program.
Supersedes DOE G 441.1-1B. Admin Chg 1 dated 7-8-11.
Supersedes:
DOE G 441.1-1B, Radiation Protection Programs Guide on May 19, 2008
Superseded By:
Certified By:
DOE G 441.1-1C (Cert Memo), Certification for DOE G 441.1-1C on Nov 18, 2010
Version history and related documents
Superseded by
A newer version replaces this document.
Supersedes
Earlier documents this one replaced.
- DOE G 441.1-1BRadiation Protection Programs Guide (May 19, 2008)
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
AVAILABLE ONLINE AT: INITIATED BY:
www.directives.doe.gov Office of Health, Safety and Security
NOT
MEASUREMENT
SENSITIVE
DOE G 441.1-1C
5-19-08
Certified: 11-18-10
RADIATION PROTECTION PROGRAMS GUIDE
for Use with
Title 10, Code of Federal Regulations, Part 835,
Occupational Radiation Protection
[This Guide describes nonmandatory approaches for meeting requirements. Guides are not
requirements documents and are not to be construed as requirements in any audit or appraisal
for compliance with the parent Rule, Policy, Order, Notice, or Manual.]
Department of Energy
Office of Health, Safety and Security
DOE G 441.1-1C i
5-19-08
TABLE OF CONTENTS
RADIATION PROTECTION PROGRAMS.................................................................... 1
1.0 PURPOSE AND APPLICABILITY ...................................................................... 1
1.1 USE OF CONSENSUS STANDARDS...................................................... 2
1.2 ACRONYMS.............................................................................................. 3
2.0 DEFINITIONS ......................................................................................................... 6
3.0 RADIATION PROTECTION PROGRAMS...................................................... 16
3.1 Implementation Guidance......................................................................... 17
3.2 Organization and Administration.............................................................. 19
3.2.0 Administrative Processes .............................................................. 19
3.2.1 Radiological Control Organization ............................................... 20
3.2.2 Education, Training, and Skills..................................................... 21
3.2.3 Internal Audit and Self Assessment.............................................. 23
3.2.4 Radioactive Material Transportation Exclusion.............................24
3.3 RPP Functional Elements ......................................................................... 24
Appendix 3.A Preparation, Review, and Approval of RPPs.....................26
4.0 ALARA ................................................................................................................... 40
4.1 Implementation Guidance......................................................................... 40
4.2 ALARA Programs .................................................................................... 41
4.2.0 Formal Plans and Measures .......................................................... 41
4.2.1 Policy and Management Commitment.......................................... 42
4.2.2 ALARA Training .......................................................................... 43
4.2.3 Plans and Procedures .................................................................... 43
4.2.4 Internal Assessments/Audits......................................................... 43
4.2.5 ALARA Design Review ............................................................... 44
4.2.6 Radiological Work/Experiment Administration and Planning ..... 47
4.2.6.0 Job/Task/Experiment Reviews....................................... 48
4.2.6.1 Consideration of Non-radiological Hazards .................. 49
4.3 Records ..................................................................................................... 50
5.0 INTERNAL DOSIMETRY PROGRAM............................................................. 51
Section 2
5.1 Implementation Guidance......................................................................... 53
5.2 Program Management and Administration............................................... 54
5.2.0 General Requirements................................................................... 54
5.2.1 Organization, Staffing, and Facilities............................................ 55
5.2.1.0 Organization................................................................... 55
5.2.1.1 Staffing........................................................................... 55
5.2.1.2 Facilities and Resources................................................. 56
5.2.2 Technical Basis Document............................................................ 56
5.2.3 Internal Dosimetry Procedures Manual ........................................ 56
5.2.4 Quality Assurance ......................................................................... 57
5.3 Air Monitoring and Contamination Control Programs............................. 57
5.3.0 Air Monitoring When There
Is No Practical Radiobioassay Method... ...................................... 57
5.3.1 Recourse for Technology Shortfall (DIL<MDA) ......................... 58
ii DOE G 441.1-1C
5-19-08
5.4 Individual Monitoring Program ................................................................ 59
5.4.0 Establishing the Need for Individual Monitoring ......................... 59
5.4.1 Investigation Levels/Derived Investigation Levels ...................... 60
5.4.2 Minimum Detectable Amount (MDA).......................................... 60
5.4.3 Frequency of Measurement........................................................... 61
5.4.4 Detection and Confirmation of Intakes......................................... 61
5.4.5 Internal Dose Management ........................................................... 62
5.4.6 Planned Special Exposures ........................................................... 63
5.4.7 Medical Response ......................................................................... 63
5.5 Internal Dose Evaluation........................................................................... 63
5.5.0 Required Dose Calculations.......................................................... 63
5.5.1 Interpretation of Radiobioassay Data............................................ 64
5.5.2 Evaluation of Internal Dose from Radiobioassay and Air
Monitoring Data............................................................................ 64
5.5.3 Periodic Reevaluation of Internal Dose ........................................ 65
5.6 Recordkeeping and Reporting................................................................... 66
6.0 EXTERNAL DOSIMETRY PROGRAM............................................................ 67
6.1 Implementation Guidance......................................................................... 70
6.2 Program Management and Administration ............................................... 70
6.2.0 General Requirements................................................................... 70
6.2.1 Organization, Staffing, And Facilities .......................................... 72
6.2.1.0 Organization................................................................... 72
6.2.1.1 Staffing........................................................................... 72
6.2.1.2 Facilities and Resources................................................. 72
Section 3
6.2.2 Technical Basis Document............................................................ 72
6.2.3 Procedures..................................................................................... 73
6.2.4 Quality Assurance ......................................................................... 74
6.3 Area Monitoring Program......................................................................... 74
6.3.0 Monitoring Instruments and Devices............................................ 74
6.3.1 Performance of Area Radiation Monitoring ................................. 75
6.3.2 Allowance for Physical Characteristics ........................................ 75
6.3.3 Recourse for Technology Shortfall ............................................... 76
6.4 Individual Monitoring Program ................................................................ 76
6.4.0 Establishing the Need for Individual Monitoring ......................... 76
6.4.1 Routine Monitoring of Individual External Doses........................ 78
6.4.1.0 Whole Body Monitoring ................................................... 78
6.4.1.1 Lens of the Eye Monitoring .............................................. 79
6.4.1.2 Skin and Extremity Monitoring ........................................ 79
6.4.1.3 Embryo/Fetal Monitoring ................................................. 80
6.4.1.4 Non-Uniform Radiation Fields ......................................... 80
6.4.1.5 Supplemental Dosimeters ................................................. 81
6.4.2 Lost, Damaged, or Contaminated Dosimeters .............................. 81
6.4.3 Nuclear Accident Dosimetry......................................................... 82
6.4.4 Planned Special Exposures ........................................................... 82
6.4.5 Personal Protective Equipment ..................................................... 83
DOE G 441.1-1C iii
5-19-08
6.5 External Dose Evaluation ......................................................................... 83
6.5.0 Required Dose Calculations.......................................................... 83
6.5.1 Special Considerations.................................................................. 85
6.6 Recordkeeping and Reporting................................................................... 87
7.0 RADIATION GENERATING DEVICES ........................................................... 88
7.1 Implementation Guidance......................................................................... 88
7.2 Administrative Organization and Controls ............................................... 89
7.2.0 Contractor Management................................................................ 89
7.2.1 RGD Custodian............................................................................. 89
7.2.2 RGD Operator............................................................................... 90
7.2.3 Qualified Expert............................................................................ 91
7.2.4 Radiological Control Manager...................................................... 91
7.2.5 Radiological Control Organization ............................................... 91
7.3 Development of Site-Specific Documents................................................ 92
7.3.0 Radiological Monitoring............................................................... 92
7.3.1 Sealed Radioactive Source Leak Testing...................................... 94
7.3.2 Area Posting.................................................................................. 94
Section 4
7.3.2.0 Radiological Conditions................................................. 94
7.3.2.1 Operational Status.......................................................... 94
7.3.2.2 Maintenance Status ........................................................... 94
7.3.3 Training .........................................................................................95
7.3.4 Records. 95
7.4 Engineered Safety Controls ...................................................................... 95
7.4.0 Shielding, Controls, & Safety Devices ......................................... 96
7.4.0.0 Shielding ........................................................................... 96
7.4.0.1 Access Control and Safety Devices ............................... 96
7.4.0.2 Interlocks........................................................................... 97
7.4.0.3 Device Controls ................................................................ 98
7.4.0.4 Run-Safe and Emergency Shutdown Devices ............... 98
7.4.0.5 Monitoring Instruments .................................................... 99
7.4.1 Guidance for Specific RGD Installations ..................................... 99
7.4.1.0 Accelerators ................................................................... 99
7.4.1.1 Electron Devices that Generate X-Rays Incidentally ..... 100
7.4.1.2 Cabinet X-Ray Systems ............................................... 100
8.0 EVALUATION AND CONTROL OF RADIATION DOSE TO THE
EMBRYO/FETUS ............................................................................................... 101
8.1 Implementation Guidance....................................................................... 101
8.2 Declaration of Pregnancy/Withdrawal of Declaration............................ 101
8.3 Work Restrictions Following Declarations of Pregnancy ...................... 103
8.4 Counseling .............................................................................................. 104
8.5 Dose Determination and Monitoring Methods ....................................... 105
8.5.0 Dose Determination .................................................................... 105
8.5.1 Monitoring Methods ................................................................... 106
8.6 Training................................................................................................... 106
8.7 Record -Keeping and Reporting ............................................................. 106
iv DOE G 441.1-1C
5-19-08
Appendix 8.B ......................................................................................................... 109
Withdrawal of Pregnancy Declaration Form ......................................................... 109
Appendix 8.C ......................................................................................................... 110
Embryo/Fetal Equivalent Dose Record Form........................................................ 110
9.0 PORTABLE MONITORING INSTRUMENT CALIBRATION ................... 111
9.1 Implementation Guidance....................................................................... 112
9.2 Instrument Selection ............................................................................... 113
9.2.0 Type Testing ............................................................................... 113
9.2.1 Acceptance Testing..................................................................... 113
Section 5
9.3 Instrument Calibration ............................................................................ 113
9.4 Operability Tests..................................................................................... 114
9.5 Maintenance............................................................................................ 114
9.6 Calibration Equipment/Calibration Quality............................................ 115
9.7 Laboratory Documentation ..................................................................... 115
9.7.0 Laboratory Protocol .................................................................... 115
9.7.1 Laboratory Records..................................................................... 116
9.7.2 Instrument Calibration Records .................................................. 116
9.7.3 Instrument Location .................................................................... 116
9.8 Laboratory and Staff ............................................................................... 116
9.8.0 Laboratory................................................................................... 116
98.1 Calibration Staff Qualifications .................................................. 117
9.8.2 Calibration Staff Training ........................................................... 117
9.9 Assessments ............................................................................................ 117
10.0 AIR MONITORING............................................................................................ 118
10.1 Implementation Guidance....................................................................... 118
10.2 Determining the Needs for Air Monitoring ............................................ 120
10.2.0 Exposure Assessment.................................................................. 120
10.2.0.0 Type and Frequency of Bioassay................................. 120
10.2.0.1 Estimation of Dose....................................................... 121
10.2.1 Personnel Protection ................................................................... 122
10.2.1.0 Need for Posting .......................................................... 122
10.2.1.1 Effectiveness of Engineered Controls.......................... 122
10.2.1.2 Proper Respiratory Protective Equipment ................... 123
10.2.2 Early Warning............................................................................. 123
10.3 Placement of Air Sampling and Real-Time
Air Monitoring Equipment ..................................................................... 124
10.3.0 Locations of Release Points and Individuals .............................. 125
10.3.1 Purpose of Sample ...................................................................... 125
10.3.2 Room Air Flow Patterns ............................................................. 126
10.4.0 Breathing Zone Air Monitoring .................................................. 126
10.4.1 Source-Specific Air Sampling .................................................... 127
10.4.2 Grab Sampling ............................................................................ 127
10.4.3 Operability Checks...................................................................... 127
10.5 Real-Time Air Monitoring Equipment ................................................... 128
10.5.0 Instrument Selection ................................................................... 128
DOE G 441.1-1C v
5-19-08
Section 6
10.5.1 Alarm Set Points ......................................................................... 128
10.5.2 Alarm Capabilities ...................................................................... 129
10.5.3 Operability Checks...................................................................... 129
10.6 Sample Analysis and Data Review......................................................... 129
10.7 Quality Control and Quality Assurance.................................................. 130
10.7.0 Sample Identification, Handling, and Storage ............................ 130
10.7.1 Air Sampling and Real-Time Air Monitoring Equipment .......... 131
10.7.2 Counting Room Equipment ........................................................ 131
10.7.3 Audits.... 132
10.7.4 Recordkeeping ............................................................................ 132
10.8 Administrative Controls.......................................................................... 132
10.8.0 Technical Basis Document ......................................................... 132
10.8.1 Written Procedures...................................................................... 133
11.0 RADIOACTIVE CONTAMINATION CONTROL......................................... 134
11.1 Implementation Guidance....................................................................... 135
11.2 Contamination Control Program Management....................................... 135
11.3 Engineered Controls................................................................................ 136
11.4 Administrative Control ........................................................................... 138
11.4.0 Work Authorizations................................................................... 139
11.4.1 Access Control ............................................................................ 139
11.4.1.0 Entry Controls.............................................................. 139
11.4.1.1 Egress Controls ............................................................ 140
11.4.1.2 Posting and Labeling.................................................... 141
11.4.2 Areas of Fixed Contamination.................................................... 141
11.4.3 Conduct of Radiological Work ................................................... 142
11.4.4 Personnel and Material Decontamination................................... 142
11.4.4.0 Skin and Clothing Contamination................................ 143
11.4.4.1 Wound Contamination ................................................. 143
11.4.4.2 Material and Area Decontamination............................ 143
11.5 Contamination Monitoring...................................................................... 143
11.5.0 Contamination Control Values ................................................... 144
11.5.1 Monitoring .................................................................................. 146
11.5.2 Control of Material and Equipment ............................................ 148
11.5.3 Portal Monitors, Laundry Monitors, and Tool Monitors ............ 151
12.0 POSTING AND LABELING FOR RADIOLOGICAL CONTROL............... 152
12.1 Implementation Guidance....................................................................... 152
12.2 General.................................................................................................... 152
Section 7
12.2.0 Design... 154
12.2.1 Content.. 155
12.2.2 Visibility ..................................................................................... 156
12.2.3 Conditions ................................................................................... 156
12.2.4 Accessibility................................................................................ 157
12.2.5 Boundaries and Barriers.............................................................. 158
12.3 Controlled Areas ..................................................................................... 158
12.4 Posting for Control of Exposure to External Radiation .......................... 159
vi DOE G 441.1-1C
5-19-08
12.5 Posting for Control of Contamination..................................................... 160
12.5.0 Removable and Airborne Radioactive Contamination ............... 160
12.5.1 Areas of Fixed Contamination.................................................... 161
12.6 Radioactive Material Posting.................................................................. 161
12.7 Exceptions from Posting Requirements.................................................. 163
12.8 Radioactive Material Labeling................................................................ 164
12.8.0 Radioactive Material Labeling.................................................... 164
12.8.1 Exceptions from Labeling Requirements.................................... 165
Appendix 12.A – Standard Radiation Warning Trefoil ......................................... 167
13.0 OCCUPATIONAL RADIATION PROTECTION
RECORD-KEEPING AND REPORTING........................................................ 169
13.1 Implementation Guidance....................................................................... 169
13.2 Records to be Generated and Maintained ............................................... 170
13.2.0 Individual Monitoring and Dose Records................................... 170
13.2.0.0 Internal Doses .............................................................. 172
13.2.0.1 External Doses ............................................................. 173
13.2.0.2 Summation of Internal and External Doses ................. 174
13.2.0.3 Lifetime Occupational Dose ........................................ 174
13.2.0.4 Non-Uniform Exposure to the Skin ............................. 175
13.2.0.5 Planned Special Exposures (PSEs) .............................. 176
13.2.0.6 Doses Resulting from Emergency
or Accidental Exposures .......................................... 176
13.2.0.7 Records of Embryo/Fetus Dose
and Declared Pregnant Workers .............................. 176
13.2.0.8 Individual Monitoring Program Records ..................... 177
13.2.0.9 Equipment Capabilities................................................ 178
13.2.1 Monitoring and Workplace Records........................................... 178
13.2.1.1 Work Authorizations.................................................... 179
13.2.1.2 Area and Material/Equipment
Monitoring Records ................................................. 180
13.2.1.3 Airborne Radioactivity Monitoring Records ............... 181
13.2.1.4 Records of Releases of Materials
and Equipment from Radiological Areas................. 182
13.2.2 Administrative Records .............................................................. 182
Section 8
13.2.2.0 Radiation Safety Training ............................................ 182
13.2.2.1 ALARA Records.......................................................... 184
13.2.2.2 Facility Design ............................................................. 185
13.2.2.3 Entry and Access Control Records .............................. 185
13.2.2.4 Sealed Radioactive Sources ......................................... 185
13.2.2.5 Radiation Protection Program, Policies and
Procedures.................................................... ............186
13.2.2.6 Audits and Programmatic Reviews.............................. 186
13.2.2.7 Posting and Labeling.................................................... 187
DOE G 441.1-1C vii
5-19-08
13.2.2.8 Calibration, Functional Tests, and Maintenance
Records .................................................................... 187
13.3 Reports .................................................................................................... 187
13.3.0 Reports to Individuals ................................................................. 188
13.3.0.0 Records Requested by Monitored Individuals............. 188
13.3.0.1 Termination Dose Reports ........................................... 188
13.3.0.2 Reports to DOE............................................................ 189
13.3.1 Reports of Planned Special Exposures ....................................... 189
13.4 Privacy Act Considerations..................................................................... 190
13.4.0 Informing Individuals ................................................................. 190
13.4.1 Identifying Individuals................................................................ 190
13.4.2 Requesting Correction or Amendment of a Record.................... 191
13.4.3 Responding to Requests.............................................................. 191
13.4.4 Accounting for Disclosures......................................................... 191
13.5 Record – Keeping Standards................................................................... 191
14.0 RADIATION SAFETY TRAINING.................................................................. 192
14.1 Implementation Guidance....................................................................... 192
14.1.0 General Information.................................................................... 192
14.2 Determination of Required Training....................................................... 193
14.3 Training Course Content......................................................................... 195
14.4 Facility-Specific Materials...................................................................... 197
14.5 Conduct of Radiation Safety Training .................................................... 198
14.6 Completion of Radiation Safety Training............................................... 198
14.7 Periodic Radiation Safety Training......................................................... 200
14.8 Use of Escorts in Lieu of Training.......................................................... 201
14.9 Refresher Training .................................................................................. 202
14.10 Other Training Programs ........................................................................ 202
14.11 Training Effectiveness Evaluations ........................................................ 202
Section 9
15.0 SEALED RADIOACTIVE SOURCE
ACCOUNTABILITY AND CONTROL ........................................................... 203
15.1 Implementation Guidance....................................................................... 203
15.2 Organization and Responsibilities .......................................................... 204
15.3 Receipt .................................................................................................... 205
15.4 Labeling and Storage .............................................................................. 206
15.5 Inventory ................................................................................................. 207
15.6 Leak Testing............................................................................................ 208
15.7 Handling and Disposal............................................................................ 210
Appendix 15.A Example Individual Accountable
Sealed Radioactive Source Form............................................................ 212
Appendix 15.B – Example Sealed Radioactive Source
Accountability Form ............................................................................... 213
16.0 TECHNICAL TABLES FOR OCCUPATIONAL
RADIATION PROTECTION............................................................................. 214
viii DOE G 441.1-1C
5-19-08
Appendix A ............................................................................................................ 214
Derived Air Concentrations (DAC) For Controlling
Radiation Exposure To Workers At DOE Facilities................................ 214
Appendix B ............................................................................................................ 247
Reserved.................................................................................................. 247
Appendix C ............................................................................................................ 249
Derived Air Concentration (DAC) For Workers From
External Exposure During Immersion in a Cloud
of Airborne Radioactive Material ............................................... 249
Appendix D............................................................................................................ 251
Surface Contamination Values ................................................................ 251
Appendix E ............................................................................................................ 253
Values For Establishing Sealed Radioactive Source
Accountability And Radioactive Material Posting
And Labeling Requirements ....................................................... 253
Appendix F............................................................................................................. 257
Radiation Weighting Factors................................................................... 257
Appendix G............................................................................................................ 258
Tissue Weighting Factors ........................................................................ 258
REFERENCES................................................................................................................. 259
DOE G 441.1-1C 1
5-19-08
RADIATION PROTECTION PROGRAMS
1.0 PURPOSE AND APPLICABILITY
Section 10
In March 2007 the U.S. Department of Energy (DOE) published an updated
implementation Guide which discussed acceptable methods for ensuring that the
functional elements of radiological activities will be managed and administered in
accordance with Title 10, Code of Federal Regulations (CFR), Part 835, Occupational
Radiation Protection (DOE 2007a), hereinafter referred to as 10 CFR 835. The March
2007 Guide was part of DOE’s efforts to eliminate redundant requirements and guidance
and compiled the guidance previously provided in a set of 13 Implementation Guides.
On June 8, 2007, the DOE published an amendment to 10 CFR 835. This Guide reflects
the June 8, 2007, amendment to 10 CFR 835 and continues to provide cross-references to
other Guides, DOE-STD-1098-99, RADIOLOGICAL CONTROL (DOE 1999a),
hereinafter referred to as the RCS, DOE directives, and industry consensus standards that
provide detailed guidance for implementing specific requirements in 10 CFR 835.
DOE is in the process of updating all of its guidance documents for occupational
radiation protection to reflect the 2007 amendment to 10 CFR 835. This Guide is one of
the first documents to be updated, and as such, the cross-references to other DOE
guidance documents will change as additional updated guidance documents are finalized.
The references to other DOE guidance documents, which are scheduled to be updated,
will include the notation “Use the revised version, reflecting the 2007 amendment to 10
CFR 835, when available.”
This Guide provides guidance with respect to implementing the provisions of all the
functional areas contained in 10 CFR 835. These are listed in Chapter 3 of this Guide.
Specific regulatory citations are provided in the body of the Guide.
This Guide amplifies the regulatory requirements of 10 CFR 835 and provides
explanations and examples of the basic requirements for implementing the requirements
of 10 CFR 835. The requirements of 10 CFR 835 are enforceable under the provisions of
Sections 223(c) and 234A of the Atomic Energy Act of 1954, as amended (AEC 1954).
This Guide was developed consistent with DOE M 251.1-1B, Departmental Directives
Program Manual, (DOE 2006a) which states that guides: (1) Provide preferred,
nonmandatory, supplemental information about acceptable methods for implementing
requirements, including lessons learned, suggested practices, instructions, and suggested
performance measures; (2) Do not impose requirements but may quote requirements if
the sources are adequately cited; and (3) Provide alternate methods that may be used if it
can be demonstrated that they provide an equivalent or better level of performance.
Except for requirements established by a regulation, contract, or administrative means,
the provisions in this Guide are DOE's views on acceptable methods of program
implementation and are not mandatory. Conformance with this Guide will, however,
create an inference of compliance with the related regulatory requirements. Alternate
2 DOE G 441.1-1C
5-19-08
methods that are demonstrated to provide an equivalent or better level of protection are
acceptable. DOE encourages its contractors to go beyond the minimum regulatory
requirements and to pursue excellence in their programs.
The word "shall" is used in this Guide in reference to requirements from 10 CFR 835.
Compliance with 10 CFR 835 is mandatory except to the extent an exemption has been
granted pursuant to 10 CFR 820, Procedural Rules for DOE Nuclear Activities (DOE
2007b). The words "should" and "may" are used to denote optional program
recommendations and allowable alternatives, respectively.
Section 11
This Guide may be used by all DOE activities that are subject to the requirements of
10 CFR 835. The Administrator of the National Nuclear Security Administration (NNSA)
will assure that NNSA employees and contractors comply with their respective
responsibilities under this Guide.
1.1 USE OF CONSENSUS STANDARDS
As discussed in the Department of Energy's Radiological Health and Safety Policy DOE
P 441.1, (DOE 1996), DOE has established a system of regulatory policy and guidance
reflective of national and international radiation protection standards and
recommendations. Consistent with this policy, this Guide endorses the use of several
national and international recommendations and standards, including several from the
International Commission on Radiological Protection, the National Council on Radiation
Protection and Measurements, the American National Standards Institute. In regards to
national consensus standards, to the extent possible, this guidance document endorses and
is written to be consistent with following non-governmental national consensus standards
for radiation protection:
• ANSI N13.3, Dosimetry for Criticality Accidents
• ANSI N43.3-1993, General Radiation Safety -Installations Using Non-Medical
X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV
• ANSI N323A-1997, American National Standard Radiation Protection
Instrumentation Test and Calibration, Portable Survey Instruments
• ANSI N13.5-R1989, American National Standard Performance Specifications for
Direct Reading and Indirect Reading Pocket Dosimeters
• ANSI N42.17A-1989, Performance Specifications for Health Physics
Instrumentation - Portable Instrumentation for Use in Normal Environmental
Conditions
• ANSI N42.17C-1989, Performance Specifications for Health Physics
Instrumentation - Portable Instrumentation for Use in Extreme Environmental
Conditions
DOE G 441.1-1C 3
5-19-08
• ANSI N42.17B, Performance Specifications for Health Physics Instrumentation -
Occupational Airborne Radioactivity Monitoring Instrumentation
• ANSI N2.1-1971(R1989), Radiation Symbol
• ANSI N13.27, Performance Specifications for Pocket-sized Alarming
Dosimeter/Ratemeters
• ANSI Z88.2-1992, Practices for Respiratory Protection
• ANSI/HPS N13.30-1996, Performance Criteria for Radiobioassay
• ANSI/HPS N13.41-1997, Criteria for Performing Multiple Dosimetry
• ANSI/HPS N43.6-1997, Sealed Radioactive Sources Classification
• ANSI /HPS N13.6-1999, Practice for Occupational Radiation Exposure Records
Systems
• ANSI/HPS N43.2-2001, Radiation Safety for X-Ray Diffraction and Fluorescence
Analysis Equipment
• ANSI/HPS N13.49-2001, Performance and Documentation of Radiological
Surveys
• ANSI/HPS N43.5-2005, Radiological Safety Standard for the Design of
Radiographic and Fluoroscopic Industrial X-Ray Equipment
• ANSI/NCSL Z540-1-1994, American National Standard for Calibration -
Calibration Laboratories and Measuring and Test Equipment -General
Requirements
• ANSI N322, American National Standard Inspection, Test, Construction, and
Performance Requirements for Direct Reading Electrostatic/Electroscope Type
Dosimeters
• ANSI N320, American National Standard Performance Specifications for Reactor
Emergency Radiological Monitoring Instrumentation
1.2 ACRONYMS
The following are the acronyms frequently used in this document.
AEC U.S. Atomic Energy Commission
ALARA Low As Is Reasonably Achievable
ALI Annual Limit on Intake
ANS American Nuclear Society
4 DOE G 441.1-1C
5-19-08
Section 12
ANSI American National Standards Institute
BEIR Biological Effects of Ionizing Radiations
BRH Bureau of Radiological Health
BZ Breathing Zone
CAM Continuous Air Monitor
CED Committed Effective Dose
CFR Code of Federal Regulations
CSO Cognizant Secretarial Officer
CTED Cumulative Total Effective Dose
DAC Derived Air Concentration
DIL Derived Investigation Level
DL Decision Level
DOE Department of Energy
DOE G DOE Guide
DOE O DOE Order
DOE P DOE Policy
DOELAP Department of Energy Laboratory Accreditation Program
DOE-STD DOE Standard
DPM Disintegrations per Minute
EPA Environmental Protection Agency
FOIA Freedom of Information Act
FR Federal Register
GERT General Employee Radiological Training
HEPA High Efficiency Particulate Air (filter)
HPS Health Physics Society
ICRP International Commission on Radiological Protection
ICRU International Commission on Radiation Units and Measurements
IL Investigation Level
ISO International Organization for Standardization
MDA Minimum Detectable Amount/Activity
NCRP National Council on Radiation Protection and Measurements
NCSL National Conference of Standards Laboratories
NIST National Institute of Standards and Technologies
NRC Nuclear Regulatory Commission
PNL Pacific Northwest Laboratory
PSE Planned Special Exposure
PSO Program Secretarial Office
DOE G 441.1-1C 5
5-19-08
RCO Radiological Control Organization
RCS DOE-STD-1098-99, RADIOLOGICAL CONTROL
RCT Radiological Control Technician
RGD Radiation-Generating Device
RMA Radioactive Material Area
RPP Radiation Protection Program
RWP Radiological Work Permit
RWT Radiological Worker Training
SLAC Stanford Linear Accelerator Center
TED Total Effective Dose
TEDE Total Effective Dose Equivalent
TLD Thermo Luminescent Dosimeter
TWD Technical Work Document
UNSCEAR United Nations Scientific Committee on the Effects of Atomic Radiation
USLW United States Law Week
6 DOE G 441.1-1C
5-19-08
2.0 DEFINITIONS
Terms from 10 CFR 835 are used consistent with their regulatory definition.
Acceptance testing: Evaluation or measurement of performance characteristics to verify
that certain stated specifications and contractual requirements are met.
Air monitoring: Actions to detect and quantify airborne radiological conditions by the
collection of an air sample and the subsequent analysis, either in real-time or offline
laboratory analysis, of the amount and type of radioactive material present in the
atmosphere.
Air sampling: A form of air monitoring in which an air sample is collected and analyzed
at a later time, sometimes referred to as retrospective air monitoring.
ALARA committee: The multi-disciplined forum that reviews and advises management
on improving progress towards minimizing radiation dose and radiological releases.
ALARA design review: A systematic review to ensure that ALARA considerations are
evaluated, incorporated if reasonable, and documented for the design of new facilities and
modifications to existing facilities that involve the potential for exposure to ionizing
radiation.
ALARA job/task/experiment review: A systematic pre- and post-job review of
high-dose and potentially high-dose activities to ensure that ALARA controls are
planned, evaluated, implemented where reasonable, and documented.
Alarm set point: The count rate or concentration at which a real-time air monitor will
alarm, usually set to correspond to a specific airborne radioactive material concentration
averaged over time (e.g., DAC-hour alarm equivalent) by calculating the sample buildup
rate on the collection medium.
Section 13
Alpha (α): The probability (not to be confused with an alpha particle) of a Type I error or
false positive. This is also called the false positive probability.
Analyte: The particular radionuclide to be determined in a sample of interest.
Baseline bioassay: An appropriate bioassay measurement obtained from a radiobioassay
program participant prior to beginning or resuming work with radioactive material.
Beta (β): The probability (not to be confused with a beta particle) of a Type II error or
false negative. This is also called the non-detection probability.
Boundary identifier: A hazard identifier that is used to define the boundary of an area.
Boundary: The line that defines the transition from one specified area to another.
DOE G 441.1-1C 7
5-19-08
Breathing zone air monitoring: A form of air monitoring that is used to detect and
quantify the radiological conditions of air from the general volume of air breathed by the
individual, usually at a height of 1 to 2 meters. See "personal air monitoring."
Cabinet X-ray system: An X-ray system with the X-ray tube installed in an enclosure
(hereinafter termed "cabinet") which, independently of existing architectural structures
except the floor on which it may be placed, is intended to contain at least that portion of a
material being irradiated, provide radiation attenuation, and exclude individuals from its
interior during generation of X-radiation. Included are all the X-ray systems designed
primarily for inspection of carry-on baggage at airline, railroad, and bus terminals, and in
similar facilities. An X-ray tube used within a shielded part of a building or X-ray
equipment which may temporarily or occasionally incorporate portable shielding is not
considered a cabinet X-ray system.
Challenge examination: An examination administered to ascertain the knowledge of a
worker with respect to radiation safety and provide an exception to the required training.
Check source: A radioactive source, not necessarily calibrated, that is used to confirm
the continuing satisfactory operation of an instrument.
Confirmed intake: An intake confirmed by follow-up radiobioassay, by association with
a known incident, or by investigation.
Contaminated area: Any area meeting the definition of “contamination area,” “high
contamination area,” or “airborne radioactivity area” provided in 10 CFR 835.2(a).
Continuous air monitor (CAM): An instrument that continuously samples and
measures the levels of airborne radioactive material on a "real-time" basis and has alarm
capabilities at preset alarm set points.
Decision level (Lc): The amount of a count (Lc or L′c) as final instrument measurement of
a quantity of analyte (Dc or D′c) at or above which a decision is made that the analyte is
definitely present.
Derived investigation level (DIL): A value of a radiobioassay or air monitoring
measurement that indicates an intake resulting in a dose exceeding an Investigation Level
(IL).
Detector: A device or component designed to produce a quantifiable response to ionizing
radiation, normally measured electronically.
Direct (in vivo) radiobioassay: The measurement of radioactive material in the human
body utilizing instrumentation that detects radiation emitted from the radioactive material
in the body.
DOELAP: The Department of Energy Laboratory Accreditation Program. This program
defines a set of reference performance tests and provides a description of the minimum
8 DOE G 441.1-1C
5-19-08
Section 14
levels of acceptable performance for personnel dosimetry systems and radiobioassay
programs under either DOE STD-1111-98, THE DEPARTMENT OF ENERGY
LABORATORY ACCREDITATION PROGRAM ADMINISTRATION (DOE 1998A), or
DOE STD-1112-98, THE DEPARTMENT OF ENERGY LABORATORY
ACCREDITATION PROGRAM FOR RADIOBIOASSAY (DOE 1998b).
Dose assessment: The process of determining radiological dose and uncertainty included
in the dose estimate, through the use of exposure scenarios, bioassay results, monitoring
data, source term information, and pathway analysis.
Elimination: The biological removal of a radionuclide from the body by excretion,
perspiration, exhalation, secretion (e.g., breast milk), exfoliation (sloughing of dead
tissue), or excision.
Embryo/fetus: A developing human organism from conception until birth.
Escort: An individual with the prerequisite training necessary for unescorted access to
the area(s) where the escort activities will be performed and who is authorized to
accompany and ensure the safety of individuals who lack such training.
Evaluation: The process of arriving at a value for intake or dose that uses, among other
inputs, measurement results.
Excretion: The biological removal of a radionuclide from the body via one or more
excretion pathways: urine and feces.
Exempt sealed radioactive source: A sealed radioactive source that does not meet the
accountability criteria established in the definition of the term “accountable sealed
radioactive source” provided in 10 CFR 835.2(a).
Exposure: The general condition of being subjected to ionizing radiation, such as by
proximity to external sources of ionizing radiation or through intake of radioactive
material into the body. In this document, exposure does not refer to the radiological
physics concept of charge liberated per unit mass of air.
False negative: A Type II (β) error, that is, concluding that analyte is not present when in
fact it is.
False positive: A Type I (α) error, that is, concluding that there is analyte present when it
is not.
Fixed contamination: Radioactive material that cannot be readily removed from
surfaces by nondestructive means, such as casual contact, wiping, or brushing.
Fixed-location sampler: An air sampler located at a fixed location in the workplace.
Frisk or frisking: Process of monitoring individuals or surfaces for contamination by
directly scanning the surface with a suitable radiation detector.
DOE G 441.1-1C 9
5-19-08
Functional tests: Tests (often qualitative) to determine that an instrument is operational
and capable of performing its intended function. Such tests may include, for example,
battery check, zero setting, or source response checks.
Geotropism: A change in an instrument's reading as its orientation changes, due to
gravitational effects.
Gestation period: The time from conception to birth; usually 40 weeks or approximately
9 months.
Grab sampling: A single sample removed from the air over a short time interval,
typically a few minutes for high volume air samplers and less than one hour for low
volume air samplers.
Hot particles: Small, discrete, highly radioactive particles that can cause extremely high
dose rates to a localized area.
Indirect (in vitro) radiobioassay: The measurement or analysis of radionuclides in
excreta or other biological samples removed from the body.
Instrument (radiation detection): A complete system consisting of one or more
subassemblies (e.g., detector, readout, etc.) designed to quantify one or more
characteristics of ionizing radiation or radioactive material.
Section 15
Intake: The amount of radionuclide taken into the body by inhalation, absorption through
intact skin, injection, ingestion, or through wounds. Depending on the radionuclide
involved, intakes may be reported in mass (e.g., μg, mg), activity (e.g., μCi, Bq), or
potential alpha energy (e.g., MeV, J) units.
Interlock: A device for precluding access to an area of radiation hazard by either
preventing entry or by automatically removing the hazard. One example is an
electro-mechanical control mechanism that interrupts the beam of ionizing radiation or
shuts down the radiation installation whenever the interlock is challenged.
Internal audits: Reviews and evaluations of the content and implementation of the
documented radiation protection program conducted by an organization neither
responsible nor accountable for developing program content or implementing the
program.
Investigation level (IL): The value of the committed effective dose from an intake(s) of a
radioactive material by a worker at or above which, for regulatory purposes, is regarded
as sufficiently important to justify further investigation
Irradiator: Any gamma- or neutron-emitting sealed radioactive material that has the
potential to create a radiation level exceeding 500 rads (5 grays) in 1 hour at 1 meter and
is operated within the requirements of an RGD installation.
10 DOE G 441.1-1C
5-19-08
Minimum detectable amount (MDA): The smallest amount (activity or mass) of an
analyte in a sample that will be detected with a probability, β, of non-detection (Type II
error) while accepting a probability, α, of erroneously deciding that a positive (non-zero)
quantity of analyte is present in an appropriate blank sample (Type I error). The MDA is
computed using the same value of α as used for the Lc. The MDA depends on both α and
β. Measurement results are compared to the Lc, not the MDA; the MDA is used to
determine whether a program has adequate detection capability. The MDA will be greater
than or equal to the Lc.
Modification: Any alteration of the shielding configuration, device or installation
operating practices, or the replacement of the original RGD (or component part thereof)
with another that has not been previously evaluated, inspected, monitored, and
documented by the radiological control organization. This definition also includes the
collocation of additional or multiple unevaluated RGDs within a previously evaluated
installation.
Normal operation: Operation under conditions as recommended by the manufacturer of
the RGD with recommended shielding and barriers in place, and as specified in the
operating procedures and requirements for the RGD installation.
Occupied (occupiable) area: An area or location that may be physically accessible by
individuals (or body parts thereof) while a radiation-generating device is in operation.
Off-normal operation: An event or condition that adversely affects, potentially affects,
or indicates degradation in the safety, security, environmental, or health-protection
performance or operation of an RGD installation.
Optimization methodology: A documented methodology which describes how the
factors affecting a protection decision, i.e., social, technical, economic, practical, and
public policy, are assigned values to compare detriment and benefits.
Performance demonstration: A demonstration by a student of the skills required to
perform certain designated activities.
Section 16
Performance tests: Tests performed periodically over the life of an instrument to verify
that it continues to meet operational requirements. Examples of performance tests are
response time and geotropism.
Personal air monitoring: A form of breathing zone air monitoring that involves the
sampling of air in the immediate vicinity (typically within one foot) of an individual’s
nose and mouth, usually by a portable sampling pump and collection tube (e.g., a lapel
sampler) worn on the body.
Physical barrier: A bounding physical obstruction that prevents unimpeded access to an
area.
Portable air sampler: An air sampler designed to be moved from area to area.
DOE G 441.1-1C 11
5-19-08
Portable monitoring instrument: An instrument intended to be operated while being
carried by an individual.
Qualified expert: An individual having the knowledge, training, and recognition of such
by management to measure ionizing radiation, to evaluate safety techniques, to design
RGD installations, and to provide advice on radiation protection requirements.
Radiation protection program (RPP): The documented program, approved by DOE,
including, but not limited to, the plans, schedules, and other measures developed and
implemented to achieve and ensure continuing compliance with 10 CFR 835 and to apply
the as low as is reasonably achievable (ALARA) process to occupational dose.
Radiation-generating device (RGD): Collective term for devices which produce
ionizing radiation, including, certain sealed radioactive sources, small particle
accelerators used for single purpose applications which produce ionizing radiation (e.g.,
radiography), and electron generating devices that produce X-rays incidentally.
Radiography: Examination of the structure of materials by nondestructive methods,
using a RGD.
Radiological control organization (RCO): An organization responsible for radiation
protection activities.
Radiological engineer: An individual who is responsible for providing technical support
and assistance to supervisors, planners, schedulers, principal investigators, and design
engineers to reduce occupational doses and the spread of radioactive materials.
Radiological work permit (RWP): The document that identifies radiological conditions,
establishes worker protection and monitoring requirements, and contains specific
approvals for radiological work activities. The RWP serves as an administrative process
for planning and controlling radiological work and informing the worker of the
radiological conditions.
Radon: Unless otherwise specified, the isotope 222Rn.
Real time air monitor: An instrument that measures the levels of airborne radioactive
material on a "real-time" basis.
Refresher training: Periodic (usually annual) training that provides current information
on changes to radiation protection policies and procedures or changes in facility
conditions, or to promote awareness of infrequently encountered radiological safety
matters.
Removable contamination: Radioactive material that can be removed from surfaces by
nondestructive means, such as casual contact, wiping, or brushing.
Representative air sampling: The sampling of airborne radioactive material in a manner
such that the sample collected closely approximates both the amount of activity and the
12 DOE G 441.1-1C
5-19-08
physical and chemical properties (e.g., particle size and solubility) of the contaminant to
which the individuals may be exposed.
Section 17
Retention: The amount of material which, after being taken into the body by inhalation,
ingestion, entry through an open wound, or absorption through the skin, exists in the
whole body, a compartment, an organ, or a tissue at a specified time.
RGD Custodian: An individual who is trained and designated to maintain cognizance
over accountability control of radiation-generating devices assigned to him or her.
RGD installation: The sum of the radiation source (e.g., sealed radioactive material or
x-ray tube), the associated equipment and component items, and the space in which they
are operated.
Five types of installations are defined as follows:
(1) Shielded installations are those designed to use the room-within-a-room concept
to limit access to the RGD beam and to place more emphasis on distance as
opposed to shielding for radiation protection and include shielded, exempt
shielded, and cabinet x-ray installations;
(2) Unattended installations are those designed for a specific purpose and that do
not require personnel in attendance for operation and include unattended gauge
and other unattended installations;
(3) Open installations are those designed to accommodate a specimen that is so large
as to make an exempt shielded installation impractical;
(4) X-ray diffraction & fluorescence analysis equipment, including both open and
closed beam installations; and
(5) Incidental, including devices that emit low levels of ionizing radiation as a
byproduct of their normal function, such as electron beam welders, electronic
microscopes, and pulse generators.
RGD Operator: An individual who is trained and deemed qualified to use a
radiation-generating device.
Routine radiobioassay monitoring: Any radiobioassay measurement made on a
predetermined, periodic schedule, to establish whether a worker has had any intake of
radioactive material since previous radiobioassay measurements.
Source custodian: An individual who is trained and designated to maintain cognizance
over accountability and control of assigned sealed radioactive sources.
Source response check: A functional test that includes the observation of the response of
an instrument to a check source.
DOE G 441.1-1C 13
5-19-08
Source user: An individual who is trained and authorized to use sealed radioactive
sources.
Source-specific air sampling: Collection of an air sample near an actual or likely release
point.
Special radiobioassay monitoring: Any radiobioassay measurement that is required for
confirmation of a suspected intake of radionuclides, or is required for follow-up
evaluation of confirmed intakes.
State-of-the-art: The most advanced technology that is commercially available and
successfully field tested.
Technical work document (TWD): A term used to generically identify formally
approved documents that direct work, such as procedures, work packages, or job or
research plans. TWDs provide radiological and ALARA controls applicable to the task.
Technology shortfall: A technology shortfall for routine radiobioassay exists when the
derived investigation level (DIL) for a well-designed and appropriate routine
radiobioassay program, using current or state-of-the-art methods and equipment, is less
than the minimum detectable amount/activity of the routine monitoring method (e.g., the
DIL is less than the MDA).
Termination radiobioassay: A radiobioassay measurement performed for the purpose of
documenting the retention of radioactive materials in the body due to occupational
exposure either upon termination of employment or upon the cessation of potential
exposure to a specific nuclide.
Section 18
Test: A procedure whereby an instrument, component, or circuit is evaluated against
certain criteria for satisfactory operation.
Thoron: Unless otherwise specified, the isotope 220Rn.
Traceability: The ability to show, through documentation, that a particular instrument or
radiation source has been calibrated using either the national standard or a transfer
standard in a chain or echelon of calibrations, ultimately leading to a comparison with the
national standard.
Type test: An initial test of one or more production instruments made to a specific design
to show that the design meets certain specifications.
Type I error: Incorrectly concluding from a result that there is analyte present; the
probability (α) of a Type I error is usually taken as 0.05. The decision level is determined
on the basis of an acceptable level of Type I errors.
Type II error: Incorrectly concluding from a result that there is no analyte present; its
probability (β) is usually taken as 0.05.
DOE G 441.1-1C 15
5-19-08
Uniform exposure: Hypothetical radiation field in which the fluence and its angular and
energy distributions are the same throughout the volume of interest.
Useful beam: That part of the primary and secondary radiation beam that passes through
the aperture, cone, or other device used for collimation.
16 DOE G 441.1-1C
5-19-08
3.0 RADIATION PROTECTION PROGRAMS
10 CFR 835 establishes specific requirements for the development, content, revision, and
approval of the documented RPP for a DOE activity. These requirements include
identifying existing and/or anticipated operational tasks and formal plans and measures
for maintaining occupational radiation doses ALARA. Guidance provided in this Guide,
in combination with the provisions of site radiological control manuals developed and
implemented consistent with guidance provided by the RCS for those regulatory
provisions not addressed by this Guide, provide reasonable assurance that a site RPP will
meet the requirements of 10 CFR 835.
The RPP for a specific DOE activity is approved by the DOE, typically by the cognizant
DOE Headquarters Program Office. The RPP is intended to provide DOE reasonable
assurance that the DOE activity will be conducted in compliance with the provisions of
10 CFR 835. The RPP also satisfies the requirement for an Implementation Plan found in
other DOE directives. Guidance concerning the specific documentation required for DOE
approval of RPPs as required in 10 CFR 835.101(f), (g), and (h) is provided in Appendix
3.A, PREPARATION, REVIEW AND APPROVAL OF RADIATION PROTECTION
PROGRAMS. Appendix 3.A is based on guidance which previously was provided in
DOE-STD-1082-94, PREPARATION, REVIEW, AND APPROVAL OF
IMPLEMENTATION PLANS FOR NUCLEAR SAFETY REQUIREMENTS. Guidance
is also provided by the cognizant DOE Headquarters Program Office.
Program Offices will also provide guidance should DOE need to direct or make
modifications to an RPP as provided under 10 CFR 835.101(b). 10 CFR 835 permits
changes, additions, or updates to an RPP to become effective without prior DOE approval
only if the changes do not decrease the effectiveness of the RPP and the RPP, as changed,
continues to meet the requirements of the rule. Proposed changes that decrease the
effectiveness of the RPP shall not be implemented without submittal to and approval by
DOE [10 CFR 835.101(h)]. Guidance regarding the process for submitting and approving
changes will be provided by the appropriate DOE Headquarters Program Office.
Section 19
The RPP is the basis for implementing operational radiation protection program
requirements for a DOE activity. A combination of various methods which can be used to
achieve regulatory compliance is discussed in this Guide. DOE recognizes that many of
the requirements of 10 CFR 835 are not new. Equivalent requirements were previously
promulgated in DOE Orders and the DOE Radiological Control Manual, which were
implemented under contractual obligations for most DOE activities involving
occupational exposure to ionizing radiation. Therefore, much of the RPP documentation
required to ensure compliance with 10 CFR 835 has already been developed to ensure
compliance with contractually-imposed radiation protection standards. DOE recognizes
that significant effort was expended in upgrading radiation protection of the work force
and does not intend for its contractors to expend significant additional effort to develop
and implement a separate, redundant program to satisfy the RPP requirements of
10 CFR 835. The RPP should rely on existing documents, such as the site radiological
control manual, contractual agreements, procedures, and memoranda, to effectively
administer and manage regulatory commitments. However, the completeness of these
DOE G 441.1-1C 17
5-19-08
existing documents should be verified to ensure that all 10 CFR 835 requirements are
satisfied. This chapter of this Guide provides guidance on the management and
administrative aspects of the RPP to achieve and maintain compliance with specific
requirements in 10 CFR 835.
Internal audits of the radiation protection program, including examination of program
content and implementation, shall be conducted through a process that ensures that all
functional elements of the program are reviewed no less frequently than every 36
months (10 CFR 835.102). This Guide discusses the role of an internal audit program
in effectively managing and administering an RPP that complies with 10 CFR 835.
These internal audits may also be incorporated into quality assurance programs
developed under 10 CFR 830 Subpart A, Quality Assurance Requirements (DOE
2001a) and/or DOE Order 414.1C, Quality Assurance (DOE 2005a). Functional
elements of a comprehensive RPP are identified and discussed throughout Section 3.2
of this Guide. The specific functional elements for a DOE activity will depend upon
the types of radiological work being performed and the radiological hazards present.
Other functional elements necessary for an integrated worker health and safety
program are not addressed in this Guide, but should be integrated with a radiological
control program. These other functional elements include: respiratory protection,
radioactive material shipment and receipt, radioactive waste management, and
emergency response.
3.1 Implementation Guidance
The approved RPP details how a DOE activity shall be in compliance with 10 CFR 835
and should identify the functional elements appropriate for that activity. Additional
documentation should be developed and maintained to supplement the approved RPP to
demonstrate that an RPP can be effectively managed and administered to achieve
compliance with 10 CFR 835. This documentation typically includes a site radiological
control manual developed to the guidance contained in the RCS, as well as detailed
implementing procedures, appropriate management policy statements, and technical basis
documentation. While this documentation need not be part of the RPP, it should be
clearly linked to the compliance commitments contained in the RPP.
Section 20
DOE has developed technical guidance to support effective implementation of programs
to ensure compliance with 10 CFR 835. The RCS was developed to provide detailed
guidance on and best practices for line management implementation of DOE's radiation
protection requirements. DOE has also developed a set of technical standards and
handbooks addressing radiation protection issues, such as training, internal dosimetry, or
plutonium operations. Additionally, DOE has developed a set of Radiological Control
Technical Positions (RCTPs). The RCTPs provide acceptable approaches to
implementing specific provisions, or otherwise address specific issues, of the Rule
(available at http://www.hss.energy.gov/HealthSafety/WSHP/radiation/tpp.html). In
addition, this Guide provides acceptable methods for achieving compliance with a variety
of technical and administrative requirements.
18 DOE G 441.1-1C
5-19-08
RPP changes may be implemented without prior DOE approval only if the RPP continues
to meet 10 CFR 835 requirements and the changes do not reduce program effectiveness
[10 CFR 835.101(h)]. Due to the wide range of activities subject to 10 CFR 835 and the
variety of methods used by these activities to ensure compliance, no specific criteria exist
by which DOE may predetermine whether an RPP change results in a reduction in
program effectiveness. Factors that should be considered include the impact of the
proposed change(s) on:
• radiological conditions in occupied areas;
• individual and collective doses;
• worker awareness of radiological conditions and controls;
• management oversight and control of routine and non-routine radiological work
activities;
• sufficiency of area and personnel monitoring programs;
• completeness and irretrievability of records;
• radiological control performance indicators;
• adherence to consensus standards; and
• other factors that ensure full implementation of the RPP.
Documentation of the rationale applied to RPP changes implemented without prior DOE
approval should be retained for future reference and demonstration of compliance.
The terms "likely" and "potential" have been used judiciously throughout the rule to
allow the use of professional judgment and experience in making decisions in specific
circumstances and provide the flexibility necessary to implement the regulatory
requirements under a broad range of activities. The technical bases and other
considerations should be documented when professional judgment is exercised. This
documentation should provide sufficient detail to permit individuals who are
responsible for implementing and assessing the RPP to clearly understand how
regulatory compliance is achieved and maintained. The RCS, Guides, and other DOE
technical standards and handbooks are designed to facilitate development and
implementation of a comprehensive RPP commensurate with the radiological hazards
associated with the DOE activity. In addition, consensus standards, such as those
developed by the American National Standards Institute (ANSI) and the Health
Physics Society (HPS), may provide additional guidance concerning technical issues
not specifically addressed by the Guides, RCS, DOE technical standards, or other
DOE guidance documents.
DOE G 441.1-1C 19
5-19-08
3.2 Organization and Administration
Section 21
The RPP shall include plans, schedules, and other measures for achieving compliance
with 10 CFR 835 [10 CFR 835.101(f)]. Plans should include establishing the organization
and administration of the RPP to ensure that the program is effectively implementing
appropriate measures that ensure regulatory compliance can be achieved and sustained.
The authority and responsibility for radiation protection should originate at the highest
levels of line management and should be emphasized throughout the organization.
Ultimately, workers should be aware of their individual responsibilities for radiation
protection. Programmatic documentation should be developed to document the
organizational and administrative aspects of the RPP.
3.2.0 Administrative Processes
The degree of formality and scope of the associated administrative processes should be
commensurate with the radiological hazards encountered and complexity of the
associated control measures. More rigorous administrative processes should be
implemented for more complex or hazardous DOE activities. Administrative processes
should include a hierarchy of documents that clearly and unambiguously delineate
management policies, requirements, expectations, and objectives for the RPP. This
documentation should typically include the following:
• Policy statement: The policy statement should articulate management’s
commitment to conduct radiological operations in a manner that will ensure the
health and safety of all its employees, contractors, and the general public. This
policy statement should be patterned after DOE P 441.1, Department of Energy
Radiological Health and Safety Policy (DOE 1996).
• Site-specific radiological control manual or handbook: This document should be
issued and endorsed by senior management for a DOE activity. This manual or
handbook should address all functional elements of the RPP for the DOE activity.
• Procedures: These documents should provide detailed instructions for
implementing various functional elements of the RPP. Responsibilities and
actions required of management and workers should be clearly and
unambiguously stated. Written procedures shall be developed and implemented as
necessary to ensure compliance with 10 CFR 835, commensurate with the
radiological hazards created by the activity and consistent with the education,
training, and skills of the individuals exposed to those hazards (10 CFR 835.104).
It is not necessary for written procedures to be developed and implemented for all
of the requirements of 10 CFR 835. Written procedures should be developed and
employed under the following circumstances:
– worker health and safety are directly affected;
20 DOE G 441.1-1C
5-19-08
– the expected outcome for the process or operation requires that a specific
method be followed;
– the process or operation is infrequently used and competence training
cannot assure adequate implementation; or
– to document the approved method to implement specific processes or
operations. In evaluating the need for written procedures, consideration
shall be given to the level and extent of the radiological hazards, the
complexity of the measures required to achieve compliance, and the
education, training and skills of the individuals who must implement those
measures (10 CFR 835.104). Under such a regimen, a low hazard activity
employing a stable staff of highly educated and skilled workers having
demonstrated an advanced knowledge of radiation protection principles
and practices could have fewer and less detailed procedures than a higher
hazard activity employing a transient workforce with less knowledge of
radiation protection practices and principles. This Guide provides
additional guidance regarding specific procedural aspects of the RPP.
Section 22
• Technical basis documents: Document decisions and approaches used to achieve
regulatory compliance, such as those decisions where professional judgment has
been exercised. The document should include supporting analyses and
justifications sufficient to demonstrate that regulatory compliance can be achieved
and maintained. This Guide contains specific recommendations for documenting
the technical basis for various RPP functional elements.
10 CFR 835 specifies the frequency for performing certain activities. Internal audits shall
be conducted on a 36 month cycle (10 CFR 835.102); radiation safety training shall be
conducted every twenty four months [10 CFR 835.901(e)]; and accountable sealed
radioactive sources shall be inventoried and leak tested every six months
[10 CFR 835.1202(a) and (b)]. DOE expects that those entities responsible for ensuring
compliance with the rule will undertake those measures necessary to perform the required
activities within the prescribed time frame (e.g., if a sealed radioactive source is leak
tested on January 15, DOE would expect the subsequent leak test to be performed on or
before July 15 of the same year). 10 CFR 835.3(e) allows a grace period of up to 30 days
when operational or scheduling considerations preclude adherence to the required
schedule (e.g., the leak test could be performed no later than August 14 of the same year).
If the provisions of 10 CFR 835.3(e) are exercised, documentation of the schedule
deviation should be developed and include a discussion of the specific activity involved
and the reason for the schedule deviation. Schedule extensions beyond the 30 day grace
period can only be granted through the regulatory exemption process under
10 CFR 820.62.
3.2.1 Radiological Control Organization
A radiological control organization should be established to support line managers and
workers. To function effectively and be consistent, as necessary, with the requirements in
DOE G 441.1-1C 21
5-19-08
DOE O 226.1, Implementation of Department of Energy Oversight Policy (DOE 2005b)
the radiological control organization should be independent of the line organizational
element responsible for production, operation, or research activities, and should have an
equivalent reporting level. Radiological control organization function is discussed in
detail in the RCS. Other organizational schemes that allow effective compliance with the
standards set forth in 10 CFR 835 should be considered to address site- or
facility-specific needs.
3.2.2 Education, Training, and Skills
Individuals responsible for developing and implementing measures necessary for
ensuring compliance with the requirements of 10 CFR 835 shall have the appropriate
education, training and skills to discharge these responsibilities (10 CFR 835.103). These
individuals can include technical and management personnel within the radiological
control organization, independent assessors, and line managers responsible for
radiological work activities. In addition, 10 CFR 830.122(b), Quality Assurance Criteria,
specifies that nuclear facility personnel shall be trained and qualified to ensure they are
capable of performing their assigned work.
Section 23
DOE previously issued requirements and guidance with regard to education, training, and
skills for many categories of personnel, including individuals responsible for developing
and implementing measures necessary for ensuring compliance with the requirements of
10 CFR 835. Some of these requirements are addressed in DOE 5480.20A, Ch. 1,
Personnel Selection, Qualification, and Training Requirements for DOE Nuclear
Facilities (DOE 2001b). This order establishes training and qualification requirements for
technical professionals and management personnel operating defense nuclear facilities.
While these requirements are not mandatory for all DOE facilities, this information may
be useful for all DOE facilities in developing training programs and standards for the
education, training, and skills appropriate for personnel to achieve compliance with the
requirements of 10 CFR 835.103 and 10 CFR 830.122(b).
Key radiation protection positions are identified in DOE STD-1107-97, KNOWLEDGE,
SKILLS AND ABILITIES FOR KEY RADIATION POSITIONS AT DOE FACILITIES
(DOE 1997a). This document supplements the requirements discussed above by
synthesizing guidance from several source documents into a single reference. DOE
STD-1107-97 describes the level of knowledge, skills, and abilities for personnel in key
radiation protection involved with DOE activities. The approach taken in DOE
STD-1107-97 reinforces the DOE’s emphasis on establishing a system of criteria for key
radiation protection positions that reflects the increasing levels of education, training, and
skills needed for positions of increasing responsibility. The information contained in this
standard should be strongly considered when evaluating the education, training, and skills
of personnel in key radiation protection positions.
The standards in DOE 5480.20A and DOE STD-1107-97 are based on DOE, Nuclear
Regulatory Commission, and related industry standards and provide an acceptable
method for achieving compliance with the requirements of 10 CFR 835.103.
22 DOE G 441.1-1C
5-19-08
DOE STD-1107-97 includes radiological control technicians (RCTs) in the list of key
radiation protection positions. While 10 CFR 835 does not establish specific requirements
for RCT training, DOE considers the typical job functions associated with RCTs to be
critical in implementing an acceptable RPP. These typical job functions include:
prescribing and implementing radiological work controls, performing radiological
monitoring, responding to radiological incidents, or evaluating radiological conditions in
the workplace. Individuals performing these functions shall meet the provisions of
10 CFR 835.103. Chapter 6, Part 4, of the RCS discusses the essential elements of RCT
training and qualification, including qualification standards, oral examination boards, and
continuing training. In support of these elements, DOE has developed and maintains the
core course for RCTs. DOE considers the DOE-developed core course for RCTs,
augmented with site specific training, an acceptable level of training for individuals
performing the typical job functions associated with RCTs. As is the case with using any
of the DOE-developed training courses, sites need to evaluate the individual’s job
functions and ensure the adequacy of the training provided.
Section 24
To ensure that the work performed by RCTs receives the appropriate level of review and
evaluation, it is important that RCT Supervisors receive a higher level of training and
maintain a higher level of knowledge than those expected of RCTs. Chapter 6, Part 4 of
the RCS also provides guidance on the essential elements of RCT Supervisor training and
qualification, including continuing training and oral examination boards.
DOE developed and implemented core courses to enhance the content of training
provided to general employees, radiological workers, and radiological control technicians
across the DOE complex and bring these core training programs up to a standard
consistent with the commercial industry. The use of the core courses is not mandatory.
However, these courses should strongly be considered as a basis for developing and
implementing radiation safety and radiological control technician training programs.
Additional guidance regarding compliance with the Subpart J requirements is provided in
Chapter 14 of this Guide.
DOE has also sponsored development of additional training courses and guidance. DOE
strongly encourages its operating entities to implement these courses and guidance. These
courses and guidance, when augmented with site specific information and appropriately
revised to reflect the most current regulatory requirements, provide acceptable
approaches for providing radiation safety training or training for individuals responsible
for developing and implementing measures necessary for ensuring compliance with the
rule. These courses include:
• DOE-HDBK-1143-2001; RADIOLOGICAL CONTROL TRAINING FOR
SUPERVISORS (DOE 2001c)
• DOE-HDBK-1145-2001; RADIOLOGICAL SAFETY TRAINING FOR
PLUTONIUM FACILITIES (DOE 2001d)
• DOE-HDBK-1141-2001; RADIOLOGICAL ASSESSOR TRAINING (DOE
2001e)
DOE G 441.1-1C 23
5-19-08
• DOE-HDBK-1105-2002; RADIOLOGICAL SAFETY TRAINING FOR
TRITIUM FACILITIES (DOE 2002a)
• DOE-HDBK-1106-97; RADIOLOGICAL CONTAMINATION CONTROL
TRAINING FOR LABORATORY RESEARCH (DOE 1997b)
• DOE-HDBK-1108-2002; RADIOLOGICAL SAFETY TRAINING FOR
ACCELERATOR FACILITIES (DOE 2002b)
• DOE-HDBK-1109-97; RADIOLOGICAL SAFETY TRAINING FOR
RADIATION-PRODUCING (X-RAY) DEVICES (DOE 1997c)
• DOE-HDBK 1110-2008; ALARA TRAINING FOR TECHNICAL SUPPORT
PERSONNEL (DOE 2008)
• DOE-HDBK-1113-98 RADIOLOGICAL SAFETY TRAINING FOR
URANIUM FACILITIES (DOE 1998c)
• DOE-HDBK-1122-99 RADIOLOGICAL CONTROL TECHNICIAN
TRAINING (DOE 1999b)
3.2.3 Internal Audit and Self Assessment
Internal audits and self assessments are two of the numerous checks and balances needed
in an effective RPP. Internal audits of the RPP, including examination of program content
and implementation, shall be conducted through a process that ensures that all functional
elements of the program are reviewed no less frequently than every 36 months
(10 CFR 835.102). The RCS discusses how assessments, including internal audits,
provide independent feedback to senior line managers concerning the implementation of
the RPP.
An audit plan or mechanism should be developed that identifies the functional elements
of the RPP and the schedule for review to ensure that over a 36 month period, all of the
functional elements are reviewed. Internal audits should be conducted on a continuing
basis. DOE cautions against conducting a single comprehensive internal audit of the
entire RPP once every three years. DOE does not believe that such an approach is
effective in assuring that a DOE activity will be conducted in conformance with its
approved RPP. DOE recommends that, at a minimum, an annual, broad scope audit of the
program be conducted. Under this approach, the audit plan would identify each functional
element to be reviewed during the annual audit and ensure that all functional elements
would be reviewed during a 36 month cycle. Thus, the RPP is under continuing review
and deficiencies can be identified and corrected in a timely manner.
Section 25
The functional elements of a comprehensive RPP are discussed in this Guide. All of these
functional elements may not be applicable to a specific DOE activity, but should be
selected based upon the type of radiological work being performed and the radiological
hazards encountered.
24 DOE G 441.1-1C
5-19-08
Internal audits should be conducted by individuals who are organizationally independent
from the organizations responsible for developing and implementing the RPP.
3.2.4 Radioactive Material Transportation Exclusion
10 CFR part 835 excludes radioactive material transportation not performed by DOE or a
DOE contractor (10 CFR 835.1(b)(7)). The intent is to exclude from 10 CFR part 835
transportation by the U. S. Postal Service or a commercial carrier, such as FedEx or UPS,
which transport radioactive material as part of their normal operations. A company or
subsidiary of a corporation that operates a DOE facility would not be considered a
commercial carrier - even if such an organization transports radioactive material as part
of its contractual agreement with DOE. Activities related to transportation such as the
preparation of material or packaging for transportation, storage of material awaiting
transportation, or application of markings and labels required for transportation is not
included in the exclusion (See 10 CFR 835.2, Definitions, Radioactive material
transportation).
Subparts F (Entry Control Program) and G (Posting and Labeling) do not apply to
radioactive material transportation conducted by a DOE individual or DOE contractor,
when the radioactive material is under the continuous observation and control of an
individual who is knowledgeable of and implements required exposure control measures
or when conducted in accordance with Department of Transportation regulations or DOE
orders that govern such movements (10 CFR 835.1(d)). This does not affect the
application of requirements to radioactive material transportation in the other subparts of
10 CFR part 835. In accordance with the definition of “radioactive material
transportation,” the exclusion applies while the material is in the process of undergoing
movement, including nominal stoppages such as for traffic considerations or refueling
activities.
Occupational doses received as a result of radioactive material transportation performed
by other than the DOE or a DOE contractor, shall be considered to the extent practicable
when determining compliance with the occupational dose limits (10 CFR 835.1(c)).
Occupational doses received by DOE or DOE contractor employees while conducting
radioactive material transportation shall be considered when determining compliance
with the occupational dose limits.
3.3 RPP Functional Elements
This section identifies the programmatic functional elements of a comprehensive RPP.
For each element, the following table identifies the applicable regulatory provisions,
contractual requirements, and recommended guidance document(s) which are useful in
achieving compliance with these provisions.
DOE G 441.1-1C 25
5-19-08
Functional Element Regulatory Provision Contractual/Guidance
Document
1. Organization and Administration 10 CFR 835, Subpart B Chapter 3.0 of this Guide
2. ALARA Program 10 CFR 835.101(c), Subpart K Chapter 4.0 of this Guide.
3. External Dosimetry Program 10 CFR 835.401 (a), 402(a), (b) Chapter 6.0 of this Guide.
4. Internal Dosimetry Program 10 CFR 835.401(a), 402(c), (d) Chapter 5.0 of this Guide.
5. Area Monitoring and Control
Section 26
a. Area Radiation Monitoring 10 CFR 835.401(a) Chapter 6.0 of this Guide.
b. Airborne Radioactivity Monitoring 10 CFR 835.209, 401(a), 403 Chapter 10.0 of this Guide.
c. Contamination Monitoring and
Control
10 CFR 835.401(a), Subpart L Chapter 11.0 of this Guide.
d. Instrument Calibration and
Maintenance
10 CFR 835.401(b) Chapter 9.0 of this Guide.
6. Radiological Controls
a. Radiological Work Planning 10 CFR 835.501(d), 1001(b), 1003 DOE-STD-1098-99,
RADIOLOGICAL CONTROL
b. Entry and Exit Controls 10 CFR 835, Subpart F Chapter 7.0 of this Guide.
c. Radiological Work Controls 10 CFR 835, Subpart F, 1003 Chapter 7.0 of this Guide.
d. Posting and Labeling 10 CFR 835, Subpart G Chapter 12.0 of this Guide.
e. Release of Materials and
Equipment
10 CFR 835.1101 Chapter 11.0 of this Guide.
f. Sealed Radioactive Source
Accountability and Control
10 CFR 835, Subpart M Chapter 15.0 of this Guide.
7. Emergency Exposure Situations 10 CFR 835.1301, 1302 DOE O 151.1-1C, Comprehensive
Emergency Management System
(DOE 2005c)
8. Nuclear Accident Dosimetry 10 CFR 835.1304 Chapter 6.0 of this Guide.
9. Records 10 CFR 835, Subpart H Chapter 13.0 of this Guide.
10. Reports to Individuals 10 CFR 835, Subpart I Chapter 13.0 of this Guide.
11. Radiation Safety Training 10 CFR 835, Subpart J Chapter 14.0 of this Guide.
12. Limits for the Embryo/Fetus 10 CFR 835, Subpart C Chapter 8.0 of this Guide.
26 DOE G 441.1-1C
5-19-08
Appendix 3.A
PREPARATION, REVIEW, AND APPROVAL OF
RADIATION PROTECTION PROGRAMS
3.A 1. PREPARATION OF RPPs
The RPPs detail how the site, facility, or activity has met or will meet the requirements of
10 CFR 835. The format for the RPP is not specified. This flexibility will permit the RPP
submitting organizations to take advantage of pre-existing documents. The following
sections describe the minimum content expected in RPPs.
Note: The term “Operations Office” is used throughout this document. Where it is
used, the term “Field Office,” “Site Office” or the term “Area Office,” as
appropriate, should be substituted where there is no Operations Office.
3.A 1.1 RPP SUMMARY
Each RPP should contain a summary section in the front to allow DOE management and
reviewers to quickly assess the more significant information contained in the RPP. The
summary should identify the following minimum information:
(1) Any requests for exemptions contained in the RPP;
(2) The total additional funding required to meet the commitments of the RPP and the
expected sources of funding by fiscal year;
(3) Any significant new programs or activities needed to meet the requirements;
(4) Any significant impacts to other programs or activities not included in the RPP;
(5) Any constraints to implementing the RPP; and
(6) Those areas where there is currently full compliance with the requirements.
3.A 1.2 GENERAL INFORMATION
The RPP should include general information which: (1) identifies that the RPP addresses
the requirements of 10 CFR 835; (2) identifies whether the RPP is the initial submittal or
a revision; (3) identifies the facilities or activities, missions, and organizations involved;
and (4) briefly discusses the content and format of the RPP.
3.A 1.3 APPLICABILITY OF REGULATORY REQUIREMENTS
The RPP should identify the specific facilities or activities covered by the RPP. Any
determination that a specific requirement is not applicable to the facilities or
activities addressed in the RPP should be documented in the RPP to ensure that the
Section 27
DOE G 441.1-1C 27
5-19-08
determination is clearly communicated. DOE approval of the RPP will constitute
agreement with applicability statements contained therein.
Applicability statements may not be used to provide relief where the requirements
are clearly stated to be applicable in 10 CFR 835. Relief from 10 CFR 835 can only
be granted by an approved exemption granted in accordance with 10 CFR Part 820,
Subpart E as discussed in Section 3.A 1.8 of this technical document.
The information provided in the plan should clearly identify which of the following
three categories applies to each requirement for a given facility, site, or activity:
(1) The requirement is applicable and the RPP defines the actions and schedules
for compliance;
(2) The requirement is applicable and an exemption is being requested; or
(3) The requirement is not applicable for the reasons documented in the RPP.
The RPP should also identify any requirements that are only partially applicable,
the limits of the applicability, and the reasons for the limitation.
Individuals should contact the appropriate Operations Office to assist with any
needed clarification of applicability statements. The Operations Office should
contact the Office of Health and Safety for any needed technical clarifications or the
Office of the General Counsel for legal interpretations of 10 CFR 835.
For example, the DOE General Counsel responded to a question concerning what
activities are intended to be included within the scope of the 10 CFR 835.1(b)(3)
exclusion. In response, General Counsel Ruling 95-1 stated "This exclusion is
drafted narrowly to cover only those activities necessary to prevent an accidental or
unauthorized nuclear detonation (that is, where the component parts of a nuclear
weapon have been assembled in a manner such that a nuclear detonation could take
place)."
There are potential situations where a DOE protective force individual could
receive an exposure to ionizing radiation in excess of the 10 CFR 835 limits (or be
in noncompliance with other 10 CFR 835 provisions) as a result of emergency
actions taken to protect nuclear or other material from theft or diversion. Per
General Counsel Ruling 95-1, these situations would not be included within the
scope of the 10 CFR 835.1(b)(3) exclusion. However, these situations, if conducted
as part of an emergency response to a threat to nuclear or other material, would
likely fall within the scope of 10 CFR 835.3(d) which states that "Nothing in this
part shall be construed as limiting actions that may be necessary to protect health
and safety."
28 DOE G 441.1-1C
5-19-08
3.A 1.4 GUIDES AND TECHNICAL STANDARDS
The RPP should identify the guides and technical standards that are to be adopted as the
means to meet 10 CFR 835. The use of guides and technical standards is not required;
however, it is encouraged for the following reasons:
(1) The use of previously approved methodologies will streamline the review and
approval process; and
(2) The use of guides and technical standards will enhance the consistent and
successful implementation of requirements across the DOE complex.
The implementing organization should consider methods and guidance from guides and
technical standards when developing the RPPs; however, alternative methods that
achieve equivalent or better results are acceptable. When an implementing organization
identifies an alternate way to implement the requirements, a reasonable opportunity will
always be provided to demonstrate compliance with the requirements using the alternate
method. Demonstration of compliance does not require an organization to address the
differences between the alternate method and the method in the guide or technical
standard unless the comparison is necessary to demonstrate acceptability.
Section 28
When guides or technical standards are used, the RPP should indicate if they are adopted
in their entirety or adopted with exceptions. The exceptions, if any, should be specifically
noted. Methodologies and guidance that are adopted with exceptions will be reviewed on
a case-by-case basis.
The adopted guides and technical standards should be listed either by:
(1) Including a list of applicable guides and technical standards in the RPP, or
(2) Incorporating a list of guides and technical standards by reference.
Commitments in an RPP to meet all or parts of guides and technical standards are
enforceable as part of the RPP.
3.A 1.5 RESOURCE ASSESSMENT
New RPPs should contain an estimate of the additional life cycle costs to implement
10 CFR 835. Revised RPPs may contain an estimate of the change in life cycle costs
associated with the revision, if the change in life cycle cost is significant. The goals of
this element of the RPP are as follows: (1) to communicate the expected new costs of
implementation to DOE management for the purposes of budget planning and
prioritization; (2) to identify the need to explore more cost effective means of
achieving compliance; and (3) to identify cases where exemptions should be
requested on the basis of insufficient benefit versus the expected implementation
costs. Identification of required resources should also serve to open a dialogue
DOE G 441.1-1C 29
5-19-08
between DOE and the RPP submitting organization on adjusting costs and activities
to the available resources.
When performing the assessments, the estimator should consider monetary costs, as well
as non-monetary resource considerations such as the limited availability of special job
capabilities (e.g., health physicists). The assessment should (1) be guided by available
quantitative and qualitative information; (2) reflect the current status of plant conditions,
configurations, and processes; (3) consider the availability of materials and resources;
and (4) consider any other information that is relevant to the radiation protection
requirements.
RPP submitting organizations should seek to achieve the broadest consistency in the
methods used to evaluate the resource requirements so that the assumptions, evaluations,
and results of the assessment can be objectively compared with the equivalent parameters
of other resource assessments. This will assist DOE and RPP activity management to
determine priorities for the use of funding. All assumptions and estimates should be made
using the best available knowledge and information.
After evaluating the resource impacts, consideration should be given if a more
cost-effective means of achieving the intent of the requirement is available. As a
minimum, the use of more cost-effective methods of compliance, or exemptions (see
section 3.A 3.1.6.7 of this attachment), should be considered whenever the resource
expenditures necessary to meet a requirement are not commensurate with the expected
safety improvements. One of the criteria for granting an exemption to a nuclear safety
requirements is that the requirement results in resource impacts which are not justified by
safety improvements. In the past DOE has granted exemptions on this basis for such
topics as radiological postings and recording tritium intakes, see
http://www.eh.doe.gov/whs/rhmwp/exemption.html.
There should be limited effort used to develop the resource assessments to only that level
of detail necessary to achieve the goals of the assessment as stated above.
Section 29
3.A 1.6 PRIORITIZATION
The RPP should include a discussion of the prioritization process used to integrate the
proposed activities into a facility or site schedule of activities. The prioritization process
is to be used to develop the proposed schedules and should be sufficiently flexible to
accommodate changes at later dates.
The prioritization process should consider available information from safety analyses and
other sources and give primary attention to controlling and reducing risks to the public,
the environment, and the workers to an acceptable level. It should also consider other
factors such as mission needs, outage schedules, and external regulations.
The prioritization process should be selected in consultation with the applicable DOE
Operations Office and Program Offices to ensure that the prioritization of efforts meets
DOE expectations. The prioritization schedule should tie budgets to schedules.
30 DOE G 441.1-1C
5-19-08
3.A 1.7 MILESTONES AND SCHEDULES
Per 10 CFR 835.101(f), the RPP must identify proposed milestones with achievable
schedules developed in accordance with the prioritization process identified in the RPP
(see Section 3.A 1.6 above). In developing the schedules, consider the resources available
to support the work, as well as any major work reductions or schedule changes in other
areas that will be required in order to meet the proposed schedules. The RPP should
identify major impacts to activities or commitments outside the scope of the RPP that will
be caused by the proposed additional activities.
Schedules should be developed using the best information available with any
assumptions on availability of resources (monetary or non-monetary) clearly stated. The
milestones and schedules will be enforceable commitments upon approval of the RPP.
Schedule commitments should be firm commitments and consequently, should not be
listed as contingent on funding. Thus, it is essential that line program representatives
participate in the review and approval of RPPs that involve additional funding needs.
Following approval of the RPPs, DOE has a responsibility to provide appropriate funding
to support the RPP schedules, the RPPs should be revised to reflect the new schedules
supported by funding (provided any schedules specifically prescribed in the DOE
requirements documents are met or schedule exemptions are approved). Such revisions
should be submitted to DOE for review and approval.
Alternatively, RPP developers may consider requesting an exemption for unfunded
activities, if the criteria for granting an exemption are met (see Section 3.A 1.8 of this
attachment).
3A 1.8 EXEMPTIONS
Exemptions are to be requested whenever relief is sought from an applicable DOE
requirement. The RPP should clearly identify any exemptions that have been approved or
are being requested from the subject requirements. The organization conducting RPP
activities may submit requests for exemptions as part of the RPP provided that they relate
to the same requirements. Requests for exemption that are submitted as part of the RPP
should be identified in the RPP summary for early recognition. Early identification of
exemption requests is important because they may need to follow a separate review and
approval process.
The provisions for requesting and granting exemptions to rules are stated in 10 CFR Part
820, Subpart E, Exemption-Relief.
3.A 2 SUBMITTAL OF RPPS
Per 10 CFR 835.101, RPPs must be submitted to the designated DOE point-of-contact
within the schedule specified in 10 CFR 835.
Section 30
Normally, the RPP is submitted to a point-of-contact located in a DOE Operations Office.
The Operations Office point-of-contact should date stamp the receipt of the RPP.
DOE G 441.1-1C 31
5-19-08
Contact the Operations Office point-of-contact in advance of the submittal date to
determine the number of copies to be submitted. Documents that are incorporated by
reference should be submitted with the RPP unless other arrangements are made with the
Operations Office point-of-contact. In addition, if the RPP is not a stand-alone document
(able to be reviewed independent of other documents), contact the Operations Office
point-of-contact prior to submittal of the RPP to discuss which supporting documents are
to be transmitted with the RPP or made available for onsite review.
Also see section 3.A 4 below for additional submittal requirements for final RPPs.
3.A 3. REVIEW AND APPROVAL OF RPPs
3.A 3.1 REVIEW AND APPROVAL PROTOCOL
The Department’s protocol for review and approval of RPPs is described below. The
protocol defines the roles, interfaces, and responsibilities of Department organizations
with respect to review and approval of RPPs. Organizations who prepare the RPPs and
the DOE organizations responsible for review and approval of the RPPs should have a
shared vision of what should be in the completed RPPs before submission of the RPP to
DOE. In order to ensure this shared vision and the development of successful RPPs, early
and continual dialogue between the RPP submitting organization and the Review Team is
essential. This dialogue should begin well before the RPP is submitted to DOE. The
process described below was built on the lessons learned in similar efforts and was
designed to facilitate that dialogue.
Because review and approval of the RPPs will often involve multiple Departmental
organizations, the review and approval process should provide for coordination,
consistency of review, and resolution of issues among those offices. In addition, the
review and approval process should address both the technical adequacy of the proposed
RPPs and the programmatic responsibilities (i.e., funding and mission). These
responsibilities will require additional coordination within the Department as they may
reside in different organizations.
The review and approval process should be sufficiently flexible to accommodate the
subjects addressed by 10 CFR 835 and adequately structured to permit efficient
completion of the review and approval within the 180 days [See 10 CFR 835.101(i)].
Table 1, at the end of this attachment, provides recommended time periods to meet this
180-day requirement.
In the review and approval process, the Operations Office should be responsible for
coordination between the RPP submitting organization and the Department’s
Headquarters staff. This focused interface will ensure consistency in the information
provided to the RPP submitting organization and allow interaction with a single
point-of-contact. In addition, the Operations Office should be responsible for
coordinating PSO (Program Secretarial Officer) approvals. It should be noted that this
attachment contains a detailed protocol. However, individual steps may be modified to or
eliminated, based on local conditions, as long as the process involves appropriate review
32 DOE G 441.1-1C
5-19-08
and approval. For example, approval authority may have been delegated to the Manager
of the Field Element (or lower), which would obviate the need for specific PSO approval
Section 31
A RPP Review Team should be formed for each RPP to conduct the review of the RPP.
The Review Team members should include DOE Headquarters and Field Operations
personnel with technical expertise and coordinating responsibility for program decisions
(e.g., funding, schedule). Operations Office personnel should serve as points-of-contact
and Review Team Leaders for RPP reviews applicable to their sites. Individual
participation in Review Team activities will vary in level of effort and time frame based
on review and approval needs.
The Operations Office point-of-contact plays a key role in coordinating all RPP review
and approval activities between DOE Headquarters and the RPP submitting organization.
The process for the development, review, and approval of RPPs is discussed below. The
provisions of 10 CFR 835.101(i) state that “an initial RPP or an update shall be
considered approved 180 days after its submission unless rejected by DOE at an earlier
date.” See Table 1 for a typical schedule of activities to meet this provision.
3.A 3.1.1 Identifications of Responsible Review Staff
3.A 3.1.1.1 Points-of-Contact
Each Operations Office Manager should identify a point-of-contact for the RPP. The
Operations Office point-of-contact should be the primary interface for all activities
associated with the development, submittal, review, and approval of the RPPs. The
Operations Office point-of-contact should also be the Review Team Leader.
The Review Team Leader should coordinate assignment of Review Team members with
the PSOs and the Operations Office.
3.A 3.1.1.2 RPP Review Teams
As discussed in the previous paragraph, the Operations Office point-of-contact should
normally be the Review Team Leader. The Operations Office Manager may provide
additional team members and technical assistance as necessary. In addition, each affected
PSO should identify the Program Office representatives for each Review Team to the
Review Team Leaders. The PSO may assign multiple reviewers to a single site or a single
reviewer.
3.A 3.1.2. Review Planning
3.A 3.1.2.1 RPP Guide
Each responsible PSO should prepare an RPP Guide that defines DOE’s specific
technical and programmatic expectations for the RPPs internal to their organization. The
guide should include the following types of information: (1) criteria and/or checklists of
DOE G 441.1-1C 33
5-19-08
items to be considered during the review, (2) approaches to key issues, (3) direction on
use of existing RPPs and approvals, (4) review and approval authorities, and (5) specific
issues relating to Headquarters or Operations Office review responsibilities. The guide
should be as brief as possible, should be user friendly, and should not repeat general
guidance available in other guidance documents such as this attachment. The PSO should
provide assistance and/or training to the Review Teams on the use of the guide.
3.A 3.1.2.2 Implementation Action Plan
For each RPP, the Review Team Group should prepare an Implementation Action Plan
that defines the Review Team activities, priorities, and schedule. A copy of the plan
should be provided for information.
3.A 3.1.2.3 Responsibility and Interface Matrix
The PSO should prepare and maintain a matrix that identifies the Review Team Leader,
Review Team members, and DOE programmatic and technical contacts for each RPP.
3.A 3.1.3 Meetings, Conference Calls, and Status Reports
3.A3.1.3.1 Initial Site Meeting
Section 32
The Review Team should meet with the RPP submitting organization at the earliest
feasible date to discuss the basic expectations for implementation of the DOE
requirements document and to discuss any issues that might impact the timely and
acceptable completion of the RPP. Issues to be discussed should include (1) how to best
use existing plans or other information in developing the RPP; (2) potential
exemptions; (3) plans and schedules for ongoing interactions; and (4) funding sources
for new activities identified as necessary to come into compliance. The Operations
Office point-of-contact has primary responsibility for planning and coordinating this
meeting.
3.A 3.1.3.2 Status Meetings
Periodic status meetings should be held with the RPP submitting organization to fully
discuss all elements of the proposed RPPs that could affect the acceptability of the
RPPs.
3.A3.1.3.3 Periodic Conference Calls
The Operations Office point-of-contact should coordinate regular conference calls with
the RPP submitting organization and the Program Offices to address and resolve issues as
they arise. As necessary, site or headquarters meetings should be held to resolve difficult
issues. The Operations Office point-of-contact has primary responsibility for coordinating
phone conferences, as well as necessary meetings to resolve issues.
34 DOE G 441.1-1C
5-19-08
3.A 3.1.4 Submittal and Distribution of RPPs
As discussed in Section3.A 2 of this attachment, RPPs should be submitted directly to the
Operation Office point-of-contact. The Operations Office point-of-contact should
transmit a copy of the RPP to the Review Team members and a copy of the transmittal
memorandum to the affected PSOs within four working days of the receipt of the RPP.
The transmittal memorandum should identify the required date for completing the review.
3.A 3.1.5 Review
3.A 3.1.5.1 Review to Review Teams
RPPs should be reviewed by an integrated Review Team with Program and Operations
Office representatives, as discussed in Section3.A 3.1.1.2 above. Program Office team
members and their contacts should, as a minimum, participate in the review of issues
involving funding, missions, schedules, priorities, and exemptions. The Review Team
Leader should facilitate resolution of unique or difficult issues not addressed in the RPP
Guide.
Review Team members should assist the RPP submitting organization in clearly
understanding what actions or changes are necessary to result in an acceptable RPP. DOE
comments and feedback should be routed through the Review Team Leader to ensure
consistent feedback. The Review Team Leader should also be responsible for resolving
conflicts prior to communication with the RPP submitter.
All reviewers should expedite their reviews to allow closure on an acceptable RPP as
early as possible.
3.A 3.1.5.2 Delegated Approval Authority for RPPs
The PSO may delegate the authority to approve specific RPPs. Any such delegation
should be provided in writing to the designee and documented in the Functions,
Responsibilities, and Authorities (FRA) document for that organization.
Wherever the authority to approve an RPP has been delegated to the Operations Office by
all of the affected PSOs, the Operations Office may choose to have the Review Team
consist entirely of Operations Office personnel provided any technical and programmatic
requirements can be handled by the designated team.
Per 10 CFR Part 820, Subpart E, the authority to approve exemptions to 10 CFR 835
cannot be delegated.
Section 33
3.A 3.1.6 Approval
3.A 3.1.6.1 Approval Recommendations by the Review Team
The Review Team Leader is responsible for ensuring that the Operation’s Office
Manager receives the Review Team’s final recommendation for approval within 145 days
DOE G 441.1-1C 35
5-19-08
after receipt of the RPP. That recommendation should either endorse acceptance of the
RPP as submitted (or changed through negotiations during the review process) or, if
issues cannot be resolved, provide recommendations regarding specific additional
commitments or changes to be incorporated in the RPP.
3.A 3.1.6.2 Operations Office Review of the Review Team Recommendations
The Operations Office Manager, or equivalent, should review the recommendation of the
Review Team and either endorse the recommendation or provide specific
recommendations for an acceptable RPP. The Operations Office Manager is responsible
for ensuring that the PSO receives the recommendations of the Review Team along with
any recommendations from the Operations Office no later than 159 days after receipt of
the RPP [with information copy to the affected CSOs [Cognizant Secretarial Officer)].
In some cases involving multiple PSOs, approval authority may be delegated by one or
more PSOs, but not all PSOs. In such cases, the Operations Office Manager should
coordinate the remaining approvals with the PSOs.
For cases in which the approval authority has been delegated by all affected PSOs to the
Operations Office Manager, the Operations Office Manager should skip to step 3.A
3.1.6.4 Approval Letter, below.
3.A 3.1.6.3 PSO Approval Memorandum
In order to ensure the Operations Office has a week to transmit the approval or
disapproval of the RPP before it becomes automatically effective 180 days after receipt
of the RPP by DOE, each affected PSO should indicate approval or disapproval of the
RPP in a memorandum to the Operations Office within 173 days of receipt of the RPP by
DOE.
3.A 3.1.6.4 Approval Letter
The Operations Office Manager should transmit the approval memorandum by letter to
the RPP submitting organization no later than 180 days after receipt of the RPP by DOE.
3.A 3.1.6.5 Imposition of RPPs
The Review Team will endeavor to resolve any issues identified during the review
process. If conflicts exist which cannot be resolved, the Department may exercise its
authority [see 10 CFR 835.101(b)] to modify proposed RPPs to include those actions and
schedules that the Department finds appropriate for achieving full compliance in a
reasonable and timely manner. In such cases, the PSO approval memorandum should be
replaced with a memorandum imposing a revised RPP. The revised RPP should be
transmitted to the RPP submitting organization by the Operations Office Manager. The
RPPs may be renegotiated at a later date, but until it is replaced by another approved
RPP, it will be the enforceable basis for implementation of 10 CFR 835.
36 DOE G 441.1-1C
5-19-08
3.A 3.1.6.6 RPPs which are not Approved by Final Date
Per 10 CFR 835.101(I), RPPs which are not approved within the approval period
specified in the DOE requirements document should be considered to be approved unless
another RPP is imposed by the Department. These RPPs may be renegotiated at a later
date, but until they are replaced by another approved RPP, they will be the enforceable
basis for implementation of 10 CFR 835.
3.A3.1.6.7 Approval of RPPs Containing Exemption Requests
Section 34
RPPs may contain requests for exemptions. When they do, the requests may be granted in
the approval memorandum for the RPP, provided that all of the requirements for
processing exemptions are met, including the approval of the DOE Headquarters official
designated by 10 CFR Part 820 Subpart E. When exemptions are approved as part of an
RPP, the approval document should state how the provisions of 10 CFR Part 820, Subpart
E were met. Alternatively, exemptions may be approved separately and referenced in the
RPP approval letter.
Upon submittal of the RPPs, the Review Team Leader should determine if any exemption
requests submitted in the RPPs need to be reviewed and approved separate from the
RPPs. Where separate review and approval is necessary, the Review Team Leader should
alert the PSO Review Team representatives to initiate a separate and expeditious review
of the exemption requests.
The provision in 10 CFR 835.101(i) that states that RPPs are considered approved 180
days after submission, does not apply to exemptions.
Approval of an RPP pending granting of an exemption does not constitute or imply
approval of the exemptions contained therein.
3.A 3.2 DISTRIBUTION OF COPIES OF THE FINAL RPP
The Operations Office Manager should be responsible for distributing approved RPPs (if
changed from the originally submitted RPP) to the Office of the Docketing Clerk (in the
Office of Price Anderson Enforcement) and to the affected PSOs. Copies of approved
RPPs transmitted to the Office of the Docketing Clerk should include both a hard copy
and an electronic copy. As required by 10 CFR Part 820, the Office of Docketing Clerk
will maintain a file of enforceable actions based upon rule violations and noncompliance
with RPPs.
3.A 3.3 REVIEW RESPONSIBILITIES
The Review Team should determine if the RPP provides an acceptable method to meet 10
CFR 835. The Review Team should also determine if the RPP adequately addresses the
elements discussed in Section 3.A 1 of this attachment (Preparation of RPPs). RPP
submitting organizations are encouraged to use the methodologies contained in this
Guide for implementation of 10 CFR 835 where they are reasonable and economical;
DOE G 441.1-1C 37
5-19-08
however, one may elect to propose an alternate way to meet the requirements. In cases
where an alternate method is proposed, the Review Team should evaluate the proposed
method to ensure that it will be adequate to meet the requirements and provide a
comparable level of safety.
The Review Team should verify that the RPP provides sufficient detail to permit DOE to
measure the progress towards meeting the DOE requirements.
The Review Team should also ensure that (1) the projected budget and schedule
information contained in the RPP is reasonable and consistent with the funding projects,
(2) the prioritization of efforts meets the DOE expectations, (3) the proposed milestones
and schedules will meet DOE needs, (4) the applicability of the requirements is correctly
identified, and (5) the compensatory actions are acceptable.
The Review Team should expect to see significant variations in the level of detail and
size of individual RPPs because of the diversity of types, sizes, and missions of DOE
facilities. In order to facilitate timely reviews and agreements on complex RPPs, the
members of the Review Team should visit the site and/or facility and have frequent
communication during both the preparation and the review of the RPP.
3.A 3.4 APPROVAL RESPONSIBILITIES
Section 35
DOE approval of the RPP constitutes acceptance by the PSO that:
(1) The proposed activities represent an acceptable method to meet the
requirements;
(2) The resources identified in the RPP are necessary and sufficient to ensure
completion of the activities contained in the RPP and are expected to be available
to support the proposed schedules;
(3) The proposed milestones and schedules are acceptable;
(4) The applicability of the requirements is correctly identified; and
(5) The identified compensatory actions are acceptable.
3A 4. REVISIONS TO RPPs
The RPPs will probably need to be revised and updated during the life cycle of the site,
facility, or activity. Approved RPPs should be revised as needed to reflect the addition or
deletion of other work at a facility or other factors that affect the ability to meet the
approved schedule, such as prospective changes in the level of funding or assumptions
regarding the availability of materials and other resources. The provisions in
10 CFR 835.101(h) contain conditions under which RPPs may be revised without prior
approval from DOE. In such cases, submit the revised RPP to DOE within 30 days of the
38 DOE G 441.1-1C
5-19-08
effective date of the RPP. All other changes to RPPs should be reviewed and approved by
DOE prior to the effective date of the change. Revised RPPs should be submitted in a
timely manner for DOE approval (at least 180 days before the change is to be effective),
along with justification for the revision. As noted previously, proposed revisions will be
considered approved 180 days after submittal to DOE, unless they are approved or
rejected by DOE.
The changes to the RPP should be clearly indicated (e.g., sidebars) to facilitate timely
review. Revised RPPs are to be submitted to DOE in the manner described in this section
and reviewed and approved in the manner described in section 3.A.3 above.
Any changes to RPPs which will result in a requirement not being met, require an
approved exemption.
3.A 5. EXTENSIONS TO THE SUBMITTAL SCHEDULE FOR RPPS
Extensions to the schedule for submitting an RPP will generally require an exemption
processed in accordance with 10 CFR Part 820, Subpart E, and approved by the
Secretarial Officer responsible for environment, safety and health matters (i.e., the Chief
Health, Safety and Security Officer).
3.A 6. IMPLEMENTATION TRACKING
Following approval of the RPP and during the implementation process, the DOE
Operations Office should oversee progress in meeting the commitments in the RPP (for
example, schedules, milestones, and costs) and maintain a dialogue on any problems that
arise.
3.A 7. INCORPORATION BY REFERENCE
The RPP submitting organization may choose to incorporate information into the RPP by
referencing all or selected portions of other documents. In such cases, the portions of the
referenced documents that are incorporated into the RPP are also subject to the provisions
of this Guide and attachment.
However there are situations when a citation or reference is used to indicate the origin of
some of the text in a document. For example, in this Guide, 10 CFR 835 is cited to
indicate the basis for statements containing the word “should” or “shall” (i.e.,
requirements). Consequently, the RPP submitting organization should clearly indicate
which documents (or portions of documents) are considered part of the RPP
commitments. The RPP submittal should maintain a file of all documents incorporated by
reference and should make non-DOE documents available to DOE upon their request.
See also section 3.A 1.2 above for submittal criteria.
Section 36
DOE G 441.1-1C 39
5-19-08
Table 1. TYPICAL SCHEDULE FOR REVIEW AND APPROVAL OF RPPS
Submittal of RPP to Operations Office
0 days
Operations Office send RPP to Review Team/PSOs/Environment, Safety and Health
4 days
Review Team sends recommendation to Operations Office Manager
145 days
Operations Office Manager sends recommendation to PSO*
159 days
PSO Approval to Operations Office*
173 days
Operations Office Manager issues approval/disapproval to RPP submitting organization
180 days
*If approval authority not delegated to the Operations Office by the PSO.
40 DOE G 441.1-1C
5-19-08
4.0 ALARA
In promulgating 10 CFR 835, DOE considered alternatives to reduce the risk from
radiation exposure to workers that included retaining the current occupational dose limits,
reducing these limits, and emphasizing efforts to maintain occupational doses As Low As
is Reasonably Achievable (ALARA). After considering public comments on this issue,
DOE elected to emphasize the ALARA process to maintain occupational dose for DOE
and contractor employees as far below the current regulatory occupational dose limits as
reasonably achievable. Adopting the ALARA process in DOE occupational radiation
protection regulations also provides consistency with recommendations provided in the
President’s Radiation Protection Guidance to Federal Agencies For Occupational
Exposure (EPA 1987), which endorsed the ALARA process.
The importance of the ALARA concept was further stressed in DOE P 441.1, DOE
Radiological Health and Safety Policy (DOE 1996), which states:
It is the policy of the Department of Energy to conduct its radiological
operations in a manner that ensures the health and safety of all its employees,
contractors, and the general public. In achieving this objective, the
Department shall ensure that radiation exposures to its workers and the
public and releases of radioactivity to the environment are maintained below
regulatory limits and deliberate efforts are taken to further reduce exposures
and releases as low as reasonably achievable. The Department is fully
committed to implementing a radiological control program of the highest
quality that consistently reflects this policy.
10 CFR 835 requires formal plans and measures for maintaining occupational exposures
ALARA as part of the documented radiation protection program (RPP). Measures include
incorporating ALARA considerations into the design of new facilities and modifications
of existing facilities, as well as activities that pose the potential for significant
occupational dose. Additionally, administrative controls are addressed as measures which
supplement engineered controls and are integrated into the work planning process.
Record keeping and training requirements related to ALARA are also specified. This
chapter of this Guide discusses acceptable methods for implementing the ALARA
process provisions in 10 CFR 835.
Due to the complex nature of many DOE activities, a combination of radiological and
non-radiological hazards may be encountered. Identification of non-radiological hazards
is critical to the ALARA process, because efforts to apply the ALARA process may
inadvertently increase risks from non-radiological hazards. An integrated safety
management approach that optimizes worker protection from all hazards should be
considered in the ALARA process for a given DOE activity.
4.1 Implementation Guidance
Section 37
Subpart B of 10 CFR 835 requires that a DOE activity shall be conducted in compliance
with an RPP approved by DOE [10 CFR 835.101(a)]. The content of the RPP shall be
DOE G 441.1-1C 41
5-19-08
commensurate with the nature of the activities performed and shall include formal plans
and measures for applying the ALARA process to occupational exposure
[10 CFR 835.101(c)]. Subpart K of the rule provides requirements for design and control
for maintaining radiation exposures ALARA. The primary methods used for maintaining
radiation exposures ALARA in controlled areas shall be engineered controls;
administrative controls may be used as supplemental features and for specific activities
where engineered controls are impractical [10 CFR 835.1001(a) and (b)]. The rule
specifies objectives for design of new facilities or modifications to existing facilities
(10 CFR 835.1002) and the integration of work controls during routine operations
(10 CFR 835.1003). Additionally, the rule requires documentation of the actions taken to
maintain occupational exposures ALARA, including actions required by the RPP, as well
as facility design and control actions [10 CFR 835.704(b)].
Guidance on complying with the training requirements of 10 CFR 835.103 and 835.901
is provided in Chapters 3 and 14 of this Guide.
This chapter provides the basic guidelines for conducting an occupational ALARA
program. It includes the requirements and guidance for developing, implementing,
documenting, and providing feedback and lessons learned for improving the program to
reduce individual doses to levels that are ALARA.
4.2 ALARA Programs
4.2.0 Formal Plans and Measures
The method of implementing an ALARA program is highly dependent on the complexity
and magnitude of potential radiological hazards associated with the DOE activity. The
elements of an effective ALARA program should be identified in a formal ALARA plan
or procedure. The RPP shall clearly identify the ALARA plans and measures employed
by the DOE activity [10 CFR 835.101(c)]. The degree of formality and the level of detail
contained in these plans and measures and other pertinent documentation should be
commensurate with the magnitude of the radiological hazard associated with the DOE
activity. A DOE activity with higher collective dose and/or potential for significant
occupational doses should have more detailed ALARA documentation than an activity
with low collective doses and/or potential for significant occupational doses. ALARA
plans and measures should address the following elements at a level commensurate with
the radiological hazards associated with the DOE activity:
• Policy and Management Commitment: Establish commitment and participation of
all line management and all levels of the work force;
• ALARA Training: Require ALARA training for all employees, including
managers involved with any aspect of radiological operations. Guidance is
provided in Chapters 4 and 14 of this Guide and the RCS;
• Plans and Procedures: Consider administrative and engineered controls and
optimization methods during work procedure development to assure that the
42 DOE G 441.1-1C
5-19-08
ALARA process is fully integrated into the development of
operational/experimental plans, procedures, and protocols. Document formal
plans and measures for applying the ALARA process to occupational doses;
• Internal Assessments/Audits: Conduct comprehensive internal reviews, audits,
and evaluations periodically and report the results to the highest levels of site
management. Guidance is provided in Chapter 3;
Section 38
• ALARA Design Review: Ensure the integration of appropriate methods and
considerations during the design phase to maintain occupational exposures
ALARA during subsequent construction, modification, and operation of the
equipment or facility;
• Radiological Work/Experiment Administration and Planning: Implement controls
and use optimization methods to assure that occupational dose is maintained
ALARA for routine and special operations or experiments; and
• Records: Maintain documents that demonstrate compliance and that the program
is adequately carried out. Guidance is provided in Chapter 13.
4.2.1 Policy and Management Commitment
Management commitment to ALARA, consistent with the DOE Radiological Health and
Safety Policy (DOE 1996), is a critical element in ensuring a successful ALARA
program. This commitment should take the form of a formal, written, policy statement
from a high level of corporate management, generally the senior site executive or
company officer responsible for radiological activities that cause the exposures. This
commitment should hold all levels of management and individual workers responsible for
adhering to the company's ALARA policy. If appropriate, union leadership endorsement
of the ALARA policy should be considered.
Senior site and line management should demonstrate their support of the ALARA
program through direct communication, instruction, inspection of the workplace, and
actions including:
• management decisions that place ALARA considerations before cost or schedule
considerations (in accordance with numerical criteria; see section 4.2.5 below);
• encouragement of and praise for workers who identify ALARA solutions;
• support of the ALARA Committee; and
• publication of ALARA success stories.
All site personnel should be made aware of management's commitment to ALARA and
radiological workers should be instructed on their responsibility to comply.
DOE G 441.1-1C 43
5-19-08
Management’s ALARA commitment statement should be periodically updated and
reaffirmed.
4.2.2 ALARA Training
Specialized ALARA training should be developed for personnel who plan, prepare,
schedule, estimate, or engineer jobs that have the potential for significant radiological
consequences. The purpose of training these personnel in ALARA concepts and
techniques is to empower them to include ALARA considerations in the early phases
of job planning and engineering. This training should provide the basics of ALARA
concepts and the use of ALARA related equipment such as containment devices,
shielding, ventilation, and special tools. Topics such as radiological waste
minimization, application of decontamination efforts, and basic contingency planning
for mitigation of accidental spills and releases may also be appropriate. DOE has
developed specialized training material for these types of positions in DOE HDBK
1110-2008, ALARA TRAINING FOR TECHNICAL SUPPORT PERSONNEL
(DOE 2008).
Discipline-specific ALARA training may be appropriate for some organizations
including: operations, maintenance, engineering, production, and construction (craft
workers). Chapter 3 provides additional guidance with respect to training for such
individuals under 10 CFR 835.103. Mock-up training may be appropriate for craft
workers and others to prepare them for unique and/or high dose jobs.
4.2.3 Plans and Procedures
Section 39
10 CFR 835.101(c) requires that the content of each RPP be commensurate with the
nature of the activities performed and include formal plans and measures for applying the
ALARA process to occupational exposures. The RPP (approved by facility management
and DOE) and supporting procedures (approved by facility management) should describe
the organization, responsibilities, and method of operation of the ALARA program.
These documents should be reviewed and updated according to an established schedule.
Chapter 3 provides additional guidance with respect to procedures required under
10 CFR 835.104.
4.2.4 Internal Assessments/Audits
10 CFR 835.102 requires that internal audits of the RPP be conducted such that all
functional elements are reviewed no less frequently than every 36 months and shall
include program content and implementation. The ALARA program is one of these
functional elements. Chapter 3 provides detailed guidance concerning internal audits.
Management's responsibilities for reviewing, auditing, and evaluating the ALARA
program should be clearly documented. The occupational ALARA program should be
evaluated by an individual(s) or members of the ALARA Committee with no direct
responsibility for implementing the program.
44 DOE G 441.1-1C
5-19-08
4.2.5 ALARA Design Review
10 CFR 835.1001 requires that measures be taken to maintain radiation exposures in
controlled areas ALARA. The primary method used shall be engineered controls (e.g.,
confinement, ventilation, remote handling, and shielding); administrative controls shall
be incorporated only as supplemental methods and for specific activities where
engineered controls are demonstrated to be impractical (10 CFR 835.1001).
10 CFR 835.1003 further requires that during routine operations, the combination of
engineered controls and administrative controls shall provide that the anticipated
occupational dose to general employees does not exceed regulatory limits and that the
ALARA process is utilized for personnel exposures to ionizing radiation. Engineered
controls typically include features that are used to control the work environment, such as
permanent structures, systems, and controls, including shielding, filtered ventilation
systems, remote controls, containment devices, and the use of designs and materials that
facilitate operations, maintenance, and other activities. They may also include controls
(e.g., temporary shielding, confinement and ventilation systems) that are typically used to
facilitate short-term or emergent operations when the installed engineered controls do not
provide the desired level of protection. In addition to the engineered controls, initial
consideration should be given to elimination or substitution of the hazards where feasible
and appropriate. This could include use of non-radioactive material or sources.
Administrative controls typically include controls that are implemented by the individual
at the work site, including written procedures, technical work documents, work
authorizations, and other controls that are used to guide individual actions in a manner
that will facilitate implementation of the ALARA process.
Section 40
DOE has an approved set of directives concerning radiological design criteria for the
design, construction, operation, and decommissioning phases of its nuclear facilities. (See
list below.) The appropriate ALARA design features should be incorporated into
modifications of existing facilities and/or equipment and designs of new facilities and/or
equipment as early as possible in the engineering and design process. From early in the
design phase and throughout the project, a radiological engineer or representative of the
radiation protection staff should be assigned to the design team. This individual should
ensure that reasonable radiological considerations have been integrated into the design,
construction procedures, proposed operating procedures, and plans for decommissioning.
Numerical criteria (e.g., dollars per rem avoided) developed for site ALARA decisions
should be used to determine those design features that are reasonable. An individual with
expertise in radiation protection, preferably from the site staff, but at least familiar with
the site program, should perform an independent ALARA design review that includes the
following elements:
• review the general configuration of the facility and/or equipment, considering
traffic patterns, location of radiation areas, location and size of changing rooms,
adequacy of personnel decontamination facilities, location of fixed monitoring
equipment, and adequacy of space for anticipated operations, maintenance,
DOE G 441.1-1C 45
5-19-08
production, research, and decommissioning. Facility design and selection of
materials shall include features that facilitate operations, maintenance,
decontamination, and decommissioning [10 CFR 835.1002(d)]. The RCS
provides additional guidance;
• verify that radiological design criteria are consistent with applicable federal/state
regulations, recognized standards and guides, and with the following DOE
directives relating to radiological safety in design:
– 10 CFR 835;
– DOE 5400.5; Radiation Protection of the Public and the Environment
(DOE 1993a);
– DOE P 441.1; Department of Energy Radiological Health and Safety
Policy (DOE 1996)
– DOE O 420.2B, Safety of Accelerator Facilities (DOE 2004a);
– DOE 5480.30, Nuclear Reactor Safety Design Criteria (DOE 1993b);
– DOE O 420.1B, Facility Safety (DOE 2005d);
– DOE O 413.3A, Program and Project Management for the Acquisition of
Capital Assets (DOE 2006b);
– DOE 435.1, Radioactive Waste Management (DOE 2001f); and
– the RCS.
• verify that the design of the confinement and ventilation systems provides the
required level of protection from airborne contamination, giving particular
attention to patterns of air flow and to the locations of air inlets, penetrations, and
exhausts. Releases of radioactive material to the workplace atmosphere should be
avoided under normal operating conditions and inhalation of such materials by
workers should be controlled to the extent reasonably achievable;
• evaluate and confirm the adequacy of specific control devices for reducing
occupational doses, including shielding, hoods, glove boxes, containments,
interlocks, barricades, shielded cells, decontamination features, and remote
operations. External sources of radiation in areas of continuous occupational
occupancy (2,000 hours/year) shall be maintained below an average of 0.5
millirem (0.005 mSv) per hour and as far below this average as is reasonably
achievable. For areas where occupancy differs from the above, external dose rates
Section 41
46 DOE G 441.1-1C
5-19-08
should be ALARA and should be maintained at a rate so as not to exceed 20% of
the limits in 10 CFR 835.202;
• verify that the design will be able to maintain personnel entry control for each
radiological area, commensurate with existing or potential radiological hazards
within the area, by using one or more of the methods listed in 10 CFR 835.501;
• verify that each entrance or each access point to high and very high radiation
areas will have the control features required by 10 CFR 835.502; and
• assess the adequacy of planned radiological monitoring and nuclear criticality
safety instrumentation and determine whether the proposed instrumentation is
appropriate for the expected types, levels, and energies of the radiation(s) to be
encountered, and whether it has sufficient redundancy and capability for operation
under normal operating conditions and during emergencies [10 CFR 835.401(b)].
The ALARA design review should have six discrete phases:
• dose assessment;
• review of projected radiological conditions against the trigger points or numerical
criteria established by management to initiate a review (e.g., creation of a new
radiation source or an increase in the dose rates from an existing source that
causes increased projected facility lifetime collective dose of greater than 5,000
millirem (50 mSv) or annual collective dose of 1,000 millirem (10 mSv), from
operations, maintenance, production, research, inspection and decommissioning
activities);
• identification of the applicable radiological design criteria;
• review of similar facilities, designs, and processes to assist in the selection of
optimum ALARA design features and less costly alternatives using approved
numerical criteria; and,
• incorporation and documentation in the design package of features to reduce the:
exposure of personnel; spread of radioactive contamination; release of radioactive
effluent; and creation of radioactive waste; and
• post-construction review of effectiveness of ALARA engineering features to
provide feedback to the design engineers and help refine the design process. The
ALARA design review should be conducted and documented in accordance with
an approved procedure and the design review package should be readily
retrievable. Detailed radiological design considerations are discussed in
PNL-6577, Health Physics Good Practices for Reducing Radiation Exposures to
as Low as Reasonably Achievable (ALARA) (PNL 1988a).
DOE G 441.1-1C 47
5-19-08
Optimization Methodology
Optimization methods are required to assure that occupational exposure is maintained
ALARA in developing and justifying facility designs or modifications and physical
controls. Optimization methodology provides the technical and managerial basis for
setting numerical criteria for ALARA decisions in the design of facilities,
development or review of work processes, and the design/purchase of special tools
and equipment. Selection of an appropriate cost benefit factor for reducing
occupational dose involves a judgment of the relative value of dose, normally in
terms of dollars per rem avoided. Additionally, guidance on optimization
methodology will also provide the basis for selection of trigger points or collective
dose values (facility lifetime, facility annual, job lifetime, one time job, etc.) above
which an ALARA design review or job review is appropriate. Numerical criteria for
ALARA decision making should include radioactive waste volume, radioactive
effluent, contamination levels, and airborne radioactivity levels. Optimization
methodology has led to a multi-attribute analysis technique which is discussed
extensively in ICRP Publication 37, Cost-Benefit Analysis in Optimization of
Radiation Protection (ICRP 1982) and ICRP Publication 55, Optimization and
Decision-making in Radiological Protection (ICRP 1990).
Section 42
At sites with significant collective dose, formally documented optimization
methodologies should be developed for ALARA reviews and decisions on
implementation of ALARA efforts should be developed. This may be on a site- or
facility-specific basis. Application of optimization methodologies to the ALARA process
should lead to consistent, rational, repeatable decisions as to which ALARA efforts are
justifiable. The level of effort involved in documenting ALARA decisions should be
commensurate with the potential dose savings to be realized. A detailed evaluation need
not be made if its cost, including the cost of documentation, outweighs the potential value
of the benefits. The procedure used to evaluate the "appropriateness" of dose-reduction
and contamination minimization decisions should be maintained. The RCS and
PNL-6577 provide additional guidance on optimization methodologies.
4.2.6 Radiological Work/Experiment Administration and Planning
10 CFR 835.1003 requires that during routine operations, the combination of engineered
and administrative controls shall provide that the anticipated occupational dose to general
employees shall not exceed the limits established in 10 CFR 835.202 and that the
ALARA process is utilized for personnel exposures to ionizing radiation. Additionally,
10 CFR 835.501(d) requires written authorizations to control entry into and perform work
within radiological areas. Often, these written authorizations take the form of radiological
work permits (RWP) or technical work documents (TWD) associated with jobs or
experiments. These written authorizations provide a convenient mechanism to integrate
ALARA review of work tasks if the requirement for ALARA review is embodied in the
written authorization. Optimization methodologies and appropriate radiological judgment
should be used to develop numerical criteria and/or trigger points for determining when a
formal ALARA review of planned radiological work activities is required. Once
48 DOE G 441.1-1C
5-19-08
conducted, the completed ALARA review should be incorporated into the written
authorizations for the work activity.
4.2.6.0 Job/Task/Experiment Reviews
A formal ALARA job/task/experiment review should be performed for work or
experiments with the potential to exceed the established numerical radiological criteria.
The following are examples of criteria that should trigger a formal ALARA review.
• the estimated individual or collective dose is greater than pre-established
criteria.
• the predicted concentrations of airborne radioactivity could exceed
pre-established criteria (such as 100 times the DAC values provided in
10 CFR 835 Appendices A and C).
• there is potential for significant radiological exposures.
• the removable contamination in work areas could exceed pre-established criteria
(such as 100 times the values provided in 10 CFR 835 Appendix D).
• individuals will enter areas where exposure rates could exceed pre-established
criteria [such as 1 rem/hour (0.01 Sv/hr)].
The ALARA job/task/experiment review should encompass three discrete phases: (1)
pre-job planning and dose assessment; (2) specification and implementation of ALARA
controls and dose tracking; and (3) post-job review.
Pre-job Planning and Dose Assessment
Section 43
Pre-job planning should include an estimate of the collective dose resulting from the
job/task/experiment and a determination regarding whether the numerical criteria for an
ALARA job/task/experiment review will be exceeded. The estimates may be based on
actual or historical radiological monitoring results. If a review is required, the next step is
to identify appropriate ALARA controls and alternatives. This should include an
assessment of the cost of controls against numerical criteria.
ALARA Controls
During the work or experiment, periodic inspections should be made to ensure that
ALARA controls are being implemented and are effective. Typical ALARA controls
implemented in the field include: appropriate use of shielding and personal protective
equipment (including respiratory protection devices), monitoring of stay times,
minimization of time in radiological areas, maximizing distances from radioactive
sources, and effective use of mock-up training and pre-job briefings. In addition,
individual and collective doses should be tracked and periodically compared to the dose
estimates to determine if intervention is needed.
DOE G 441.1-1C 49
5-19-08
Post-Job Review
Criteria should be established to trigger a formal post-job review. Examples include:
• an actual collective dose equivalent of 5 person-rem or greater,
• actual doses outside the range of 25% of pre-job estimates,
• use of the stop radiological work authority,
• issuance of a radiological occurrence/deficiency report, or
• identification of significant lessons learned.
The post-job review should compare the actual person-hours and person-rem with the
estimates, evaluate the effectiveness and cost of the ALARA controls, document the
lessons learned, and make recommendations on ways to control dose and contamination
for similar activities. The ALARA review should be documented and records should be
readily retrievable.
In the special case of an ALARA review for a planned special exposure, additional
requirements are described under 10 CFR 835.204.
4.2.6.1 Consideration of Non-radiological Hazards
The work planning process should integrate the consideration of other industrial,
physical, and chemical hazards that an individual may encounter. Efforts to maintain
worker doses ALARA should ensure that the risk of personnel injury from other hazards
is not disproportionately increased. The ALARA process should consider the impact of
other occupational hazards when optimizing worker radiation dose. For example:
• excessive protective clothing to control personnel contamination events may lead
to heat stress situations.
• respiratory protective devices used to reduce intakes of radionuclides may impair
visual acuity and communications capabilities between workers.
• protective clothing to protect workers from chemical hazards may slow work
down leading to increased worker dose.
An integrated approach during the work planning process will ensure that all
occupational hazards are appropriately considered and the ALARA process is followed.
10 CFR 851, Worker Safety and Health Program (DOE 2006c) provides requirements for
worker safety and health. The worker safety and health program must integrate the Rule’s
requirements with other site worker protection activities and the integrated safety
management system (ISMS) [851.11(a)(3)(ii)]. Coordination should be established,
maintained, and documented among worker safety and health technical disciplines and
Section 44
50 DOE G 441.1-1C
5-19-08
other safety and health organizations (e.g., radiation control) at a site to ensure successful
implementation of the worker safety and health program.
Additional information concerning DOE expectations for integrating safety management
can be found in Department of Energy Acquisition Regulations (DEAR) clause
48 CFR 970.5223-1, Integration of Environment, Safety and Health into Work Planning
and Execution. This states that “the contractor will manage and perform work in
accordance with a documented Safety Management System (System).”
DOE G 440.1-8, Implementation Guide for Use with Title 10 Code of Federal
Regulations Part 851 (DOE 2006d) provides guidance for establishing and implementing
an ISMS program.
4.3 Records
Actions taken to maintain occupational exposures ALARA shall be documented and
retained [10 CFR 835.701(a) and 835.704(b)]. Administrative controls discussed in this
Guide should include the systematic generation and retention of those auditable records
and reports that document major actions considered or taken to attain and maintain
occupational doses and the spread of radioactive contamination ALARA. The RCS and
Chapter 13 provide detailed guidance on record-keeping.
All documents and legal records used to demonstrate compliance with ALARA program
requirements should be reviewed and approved by supervisory or line management.
DOE G 441.1-1C 51
5-19-08
5.0 INTERNAL DOSIMETRY PROGRAM
In the 2007 amendment to 10 CFR 835 DOE changed most of the dosimetric terms used
in 10 CFR 835 to reflect the recommendations for assessing dose and associated
terminology from ICRP Publication 60, 1990 Recommendations of the ICRP on
Radiological Protection (ICRP 1991), and ICRP Publication 68, Dose Coefficients for
Intakes of Radionuclides by Workers (ICRP 1995). DOE made this change mainly
because these recommendations are based on updated scientific models and more
accurately reflect the occupational doses to workers than the models currently used by
DOE.
During the rulemaking process DOE received a comment that, under certain
circumstances, when an individual conducts multiple activities involving both activities
under 10 CFR 835.1(b)(1) and excluded activities (e.g., activities involving NRC licensed
activities) it is ambiguous as to how the rule would be applied when using different dose
coefficients and weighting factors to calculate the total effective dose for the worker from
both activities. DOE agreed that guidance was needed for this provision. In the preamble
for the final rule DOE stated that for the purpose of compliance with 10 CFR 835.1(b)(1)
and (c), DOE considers the following terms to be equivalent:
Dosimetric Term as Defined by Excluded
Activity Cognizant Regulator DOE Amended Dosimetric Term
Committed effective dose equivalent
Committed effective dose
Committed dose equivalent
Committed equivalent dose
Cumulative total effective dose equivalent
Cumulative total effective dose
Deep dose equivalent
Equivalent dose to the whole body
Dose equivalent
Equivalent dose
Effective dose equivalent
Effective dose
Lens of the eye dose equivalent
Equivalent dose to the lens of the eye
Quality factor
Radiation weighting factor
Shallow dose equivalent
Equivalent dose to the skin or
Equivalent dose to any extremity
Weighting factor
Tissue weighting factor
Total effective dose equivalent
Total effective dose
52 DOE G 441.1-1C
5-19-08
Section 45
Accordingly, for the purpose of compliance with the requirement in 10 CFR 835.1(c) for
the inclusion of doses from excluded activities in determining compliance with the limits,
DOE considers it acceptable to sum the equivalent dosimetric terms (per the above table)
without further adjustment. DOE recognizes that, for some situations, such as evaluation
of uranium intakes, this approach will overestimate radiation doses from excluded
activities as compared to those assessed using ICRP 60 values. For other situations, such
as the evaluation of certain neutron exposures or for intakes of selected radionuclides,
this approach may underestimate radiation doses from excluded activities as compared to
those assessed using ICRP 60 values.
In cases where doses from excluded activities are expected to have been over estimated,
no additional activities above the standard radiological controls are required because this
dose estimate is unlikely to have resulted in a dose less than that estimated using ICRP 60
methods.
Regarding cases where doses from excluded activities are expected to have been
underestimated, a review of doses over the past several recent years, from both DOE and
NRC, indicated very few examples where individuals had neutron exposures or
significant intakes of those radionuclides which could underestimate radiation doses from
excluded activities as compared to those assessed using ICRP 60 values. Accordingly, the
differences in assessing these intakes or neutron doses between DOE (ICRP 60) and
excluded activities would infrequently result in doses challenging limits had they been
entirely assessed using ICRP 60 values. Use of Administrative Control Levels, per the
RCS, should be adequate to address concerns regarding these situations.
See Section 6.0.1, “Protection and Operational Quantities” for a discussion on the use of
protection and operational quantities.
Radiation protection programs for limiting intakes of radioactive material are based on
the DOE policy of controlling radioactive material at the source. It is nonetheless
recognized that low-level, chronic, or intermittent occupational exposures to some
materials may be difficult to avoid due to the types of material handled or processed, their
chemical or physical forms, and the nature of operations, and that incidents may cause
unplanned releases of radioactive material. 10 CFR 835.402(c) requires internal
dosimetry programs (including routine radiobioassay programs) be conducted for
radiological workers, declared pregnant workers, occupationally exposed minors, and
members of the public entering controlled areas who are likely to receive intakes that
exceed specified levels for committed effective dose in a year. An internal dosimetry
program generally consists of three elements:
• An air monitoring program, using a combination of real-time, fixed, and portable
devices, as appropriate;
• an individual monitoring program, using direct and/or indirect radiobioassay, and
personal breathing zone (BZ) air monitoring, as appropriate; and
DOE G 441.1-1C 53
5-19-08
• a dose evaluation program that evaluates the data collected by the air and
individual monitoring programs to determine the magnitude of individual doses.
5.1 Implementation Guidance
Section 46
This section provides guidance for establishing and conducting internal dosimetry
programs for individuals who have the potential for intakes of radioactive materials. It
includes guidance for design and implementation of the radiobioassay program, and
guidance for evaluating, recording, reporting, and managing internal doses. Additional
technical guidance is provided in DOE-STD-1121-2003, INTERNAL DOSIMETRY
(DOE 2003) and the National Council on Radiation Protection and Measurements
(NCRP) Report No. 87, Use of Radiobioassay Procedures for Assessment of Internal
Radionuclide Deposition (NCRP 1987a).
An acceptable internal dosimetry program includes the following features:
• adequate staff with appropriate technical training;
• internal dosimetry technical basis documentation providing scientific information
and other rationale explaining essential elements of the internal dosimetry
program to support dose evaluation methods;
• written policies and procedures covering essential steps in the activities used to
determine worker internal dose;
• criteria and methods for implementing an appropriate air monitoring program;
• defined criteria for identifying workers who need to participate in the individual
monitoring program;
• appropriate radiobioassay measurement methods and frequencies;
• methods for control, accountability, and safe handling of samples;
• appropriate dosimetric models and default parameters for evaluating internal
dose;
• timely analysis of radiobioassay samples and measurements, transmission of
results, dose evaluation, and recommendations to operations management;
• adequate detection capability and quality of radiobioassay measurements;
• defined criteria and actions for identifying individuals with suspected intakes,
based on workplace measurements and radiobioassay measurements;
• appropriate action level guidelines;
54 DOE G 441.1-1C
5-19-08
• defined program to report internal doses to workers, management, and
DOE;
• historical records of radiobioassay measurement results and dose
evaluations;
• historical records of the program, and changes in the program over time; and a
quality assurance program covering essential steps in the activities that determine
worker internal dose.
5.2 Program Management and Administration
5.2.0 General Requirements
The internal dosimetry program shall be adequate to demonstrate compliance with the
dose limits established in Subpart C of 10 CFR 835 [10 CFR 835.402(d)]. In addition,
radiobioassay programs implemented to demonstrate compliance with the requirements
in 10 CFR 835.402(c) (individual monitoring thresholds) shall be:
• accredited or excepted from accreditation in accordance with the DOELAP for
Radiobioassay [10 CFR 835.402(d)(1)]; or
• determined by the Secretarial Officer responsible for environment, safety and
health matters (i.e., the Chief Health, Safety and Security Officer) to have
performance substantially equivalent to that of programs accredited under
DOELAP for radiobioassay [10 CFR 835.402(d)(2)].
Guidance for achieving accreditation or exception from accreditation under
DOELAP is provided in DOE-STD-1111-98, DEPARTMENT OF ENERGY
LABORATORY ACCREDITATION PROGRAM ADMINISTRATION (DOE
1998a). Requests for other program determinations will be considered by DOE on a
case-by-case basis.
Section 47
The provision requiring accreditation for radiobioassay programs implemented to
demonstrate compliance with 10 CFR 835.402(c) does not reflect an intent to provide a
lesser degree of protection to individuals unlikely to receive doses exceeding the
regulatory monitoring thresholds, nor does it express a desire to establish two separate
radiobioassay programs (i.e., an accredited program for individuals likely to exceed the
regulatory monitoring thresholds and a non-accredited program for individuals who are
unlikely to exceed these thresholds). Rather, those individuals who are unlikely to
exceed the regulatory monitoring thresholds are provided an adequate degree of
protection by the various engineering and administrative controls that limit their
internal doses. Implementation of a comprehensive air monitoring program in
accordance with 10 CFR 835.401 and 403 verifies the effectiveness of these controls.
When an accredited radiobioassay program already exists and management of any
given facility chooses to provide monitoring for those individuals who are unlikely to
DOE G 441.1-1C 55
5-19-08
exceed the regulatory monitoring threshold, consideration should be given to using the
accredited program. This will obviate the need to implement two radiobioassay
programs, one accredited and the other not. In addition, it will avoid giving workers
who are not required to be monitored the impression that they are being provided a
lesser degree of protection. However, this does not imply that the monitoring program
for those unlikely to exceed the monitoring threshold must be accredited.
Sections 401 through 403 of 10 CFR 835 establish specific monitoring requirements for
areas and individuals. 10 CFR 835 also establishes requirements for maintaining
individual monitoring records (10 CFR 835.702) and reporting radiation doses to
individuals (10 CFR 835.801).
5.2.1 Organization, Staffing, and Facilities
5.2.1.0 Organization
The internal dosimetry program should be administered by the radiological control
organization under the leadership of the radiological control manager. The internal
dosimetry program should have a designated leader with demonstrated expertise in
internal dose evaluation. When elements of the internal dosimetry program are performed
by one or more subcontractors, the radiological control organization should establish an
arrangement of contractual standards and assessments that ensure that subcontractors
meet all applicable requirements in 10 CFR 835, the documented Radiation Protection
Program (RPP), DOELAP standards, and the internal dosimetry technical basis
document.
5.2.1.1 Staffing
The radiological control organization management should ensure that the internal
dosimetry program is adequately staffed to carry out its functions. The analysis of
workplace and radiobioassay measurement data and the evaluation of internal dose
involve complex evaluation and professional judgment. Personnel with responsibility
for internal dose evaluation should have the necessary expertise and skill, based on
appropriate education and training in conjunction with practical experience, to perform
their assigned duties. Additional guidance on education, skills, and training is provided
in Chapter 3. It is important that internal dosimetry specialists be capable of
recognizing conditions warranting follow-up radiobioassay and dose evaluation.
Personnel should be familiar with the relevant internal dosimetry literature and the
recommendations of national and international scientific organizations with regard to
internal dose evaluation.
Section 48
Management of the radiological control organization should establish minimum
requirements for those staff who evaluate internal doses. These requirements should
include both experience and education requirements. Suggested educational background
and formal training needed for internal dosimetry program key positions are listed in
56 DOE G 441.1-1C
5-19-08
DOE-STD-1107-97, KNOWLEDGE, SKILLS, AND ABILITIES FOR KEY
RADIATION PROTECTION POSITIONS AT DOE FACILITIES (DOE 1997a).
Members of the internal dosimetry staff should meet these requirements, or the staff
should have access to individuals with the required background (perhaps through
interdepartmental agreements or contracted services). It is not necessary for all personnel
on the staff to have expertise in all of the listed subject areas.
5.2.1.2 Facilities and Resources
Computational facilities and software tools used by internal dosimetry personnel should
be adequate for performing calculations required for the evaluation of dose from
radionuclides in the body. A library of handbooks, reference materials, scientific
publications, and other resources pertaining to internal dosimetry should be readily
available. Suggested reference materials are included in the reference chapter of this
Guide. DOE O 414.1C, Quality Assurance (DOE 2005a), establishes quality process
requirements to be implemented under a QA program (QAP) for the control of
suspect/counterfeit items (S/CIs), safety issue corrective actions, and safety software.
5.2.2 Technical Basis Document
Internal dosimetry technical basis documentation should be developed and should include
technical methods, supporting evidence, and reference information used to provide the
technical foundation for the internal Dosimetry program. The internal dosimetry technical
basis documentation should provide the approach to evaluating internal doses from
radiobioassay data, and for situations in which there is no practical radiobioassay, from
representative air monitoring or other appropriate data. The technical basis
documentation should address all of the topics listed under Section 3.1 of
DOE-STD-1121-2003. The technical basis documentation should be reviewed
periodically and updated as necessary to ensure that the scientific bases are appropriate
for current conditions. The technical basis documentation should be controlled and
retained as a radiation protection program record.
5.2.3 Internal Dosimetry Procedures Manual
10 CFR 835 requires that written procedures be developed and implemented as necessary
to ensure compliance, commensurate with the radiological hazards created by the activity
and consistent with the education, training, and skills of the individuals exposed to those
hazards (10 CFR 835.104). Essential elements of the internal dosimetry program should
be addressed in written procedures. These procedures should be consistent with
10 CFR 835, the DOELAP standard, and technical basis documentation.
Detailed guidance on topics that should be addressed in the internal dosimetry procedures
manual are discussed in Section 3.2 of DOE-STD-1121-2003. Additional guidance on
written procedures is provided in Chapter 3 of this Guide.
DOE G 441.1-1C 57
5-19-08
5.2.4 Quality Assurance
Quality Assurance for internal dosimetry programs is addressed in DOE-STD-1121-2003,
Section 11. Quality assurance in support of internal dosimetry programs should be
conducted in accordance with this DOE standard.
Section 49
The internal dosimetry program should be included as a functional element subject to the
internal audit requirements of 10 CFR 835.102. Chapter 3 provides guidance on internal
audit programs. External peer-review by qualified individuals, on a periodic basis, is also
recommended.
5.3 Air Monitoring and Contamination Control Programs
The objectives of an air monitoring program are to verify the integrity of radioactive
material containment, detect the release of radioactive materials from some routine
operations, detect inadvertent releases of those materials in the workplace, evaluate and
provide the basis for modification to containment systems, provide a basis for the design
of radiobioassay programs, and verify that selected groups do not need to participate in a
radiobioassay program. Air monitoring programs and internal dosimetry programs are
complimentary. The air monitoring program provides an indication of the effectiveness of
engineering and administrative controls in preventing or minimizing worker intakes and
the internal dosimetry program provides verification of the adequacy of these controls in
preventing or minimizing worker intakes.
The air monitoring and contamination control programs supplement the individual
monitoring program by providing a prospective assessment of radiological conditions,
facilitating decisions regarding postings, access controls, work authorizations, and
individual monitoring, and providing back-up data for use in individual dose evaluations.
Because of the need to evaluate individual internal doses from intakes of radioactive
material from uncontained sources, airborne radioactive material, and surface
contamination, the air monitoring and contamination control programs should include
methods for assessing the degree of hazard arising from each of these hazards to which
individuals may be exposed. Guidance for implementing contamination control and air
monitoring programs is provided in Chapters 10 and 11 of this Guide.
In most cases the air monitoring program is used to supplement and validate the
individual monitoring program. However, in the case when there is no practical
radiobioassay method or when there is a technology shortfall (e.g., the DIL is less than
the MDA) the air monitoring program may be the basis for the determination of internal
doses. These two cases are discussed below.
5.3.0 Air Monitoring When There Is No Practical Radiobioassay Method
In situations where no radiobioassay method is available for the radionuclides in
question, and no radiobioassay program, either routine or special, can show compliance
58 DOE G 441.1-1C
5-19-08
with 10 CFR 835, personal (BZ) air monitoring may be used for demonstrating
compliance with 10 CFR 835. BZ air monitoring is part of the Individual Monitoring
Program which is detailed below. However, other fixed or portable monitoring
instruments that provide either real-time (such as continuous air monitors) or
retrospective (such as grab sampling which is analyzed at some time after the sample is
collected) may be required when BZ monitoring data is not available or to supplement or
validate the BZ data if it is available. Radionuclides with short half-lives, including the
short-lived decay products of 222Rn (“radon” decay products 218Po, 214Pb, 214Bi, and
214Po) and 220Rn (“thoron” primary decay products 212Pb and 212Bi) are examples of
radionuclides where intakes cannot be determined through radiobioassay and must be
determined from personal air monitoring. For detailed information on non-background
exposures to radon and thoron, see DOE-STD-1121-2003, Section 4.5. Monitoring
programs for radon and thoron should be in accordance with the DOE standard.
Section 50
5.3.1 Recourse for Technology Shortfall (DIL<MDA)
DILs for reasonable and practical routine radiobioassay programs may be significantly
less than the achievable MDA for certain radionuclides, such as plutonium. Since a
technology shortfall for routine radiobioassay exists, the facility should consider the
following actions (note that some of these suggested actions fall under the category of
individual as opposed to area monitoring, but for completeness they are all listed below):
• enhance contamination and air monitoring and the use of indicators (e.g.,
unexpected glove or surface contamination, increase in airborne radioactive
material contamination, nasal smears) to trigger early special radiobioassay
monitoring;
• enhance personal contamination monitoring (e.g., clothing, skin) to trigger special
radiobioassay monitoring;
• use the best practicable radiobioassay monitoring methods;
• implement enhanced design, operation, controls, and personnel protection
equipment and procedures to minimize intakes;
• implement supplementary air monitoring; and
• document and justify the planned supplementary approach in the facility's internal
dosimetry technical basis documentation.
When air monitoring data are used, each worker's stay times (in hours) and the average
concentration (in DACs) to which the worker is exposed should be multiplied to yield
exposures to airborne radioactive materials in units of DAC-hours. Forty (40) DAC-hours
corresponds to 0.1 rem (0.001 Sv) committed effective dose for radionuclides with a
stochastic ALI.
DOE G 441.1-1C 59
5-19-08
A technology shortfall for routine radiobioassay should not be sufficient cause for failing
to place individuals on a minimum or best-available radiobioassay program. Refer to
DOE-STD-1121-2003, Section 4.4.4, for a discussion and examples of technology
shortfalls and suggested methods to handle such situations.
5.4 Individual Monitoring Program
Individual monitoring programs should be designed in accordance with Section 4 of
DOE-STD-1121-2003 and should:
• provide for investigation of suspected intakes;
• provide data for evaluating internal dose; and
• provide results that are adequate to demonstrate compliance with the radiation
dose limits given in 10 CFR 835. The primary methods of routine and special
worker radiobioassay are direct (in vivo) radiobioassay and indirect (in vitro)
radiobioassay.
In situations where there is no practical radiobioassay, representative air monitoring (e.g.
breathing zone (BZ) air monitoring) is the preferred measurement method on which to
base dose evaluations. Additional guidance on air monitoring programs may be found in
Chapter 10 of this Guide.
5.4.0 Establishing the Need for Individual Monitoring
Radiological workers who could likely receive intakes resulting in 0.1 rem (0.001 Sv) or
more committed effective dose in a year shall participate in an internal dose evaluation
program [10CFR 835.402(c)(1)]. Declared pregnant workers, occupationally exposed
minors, and members of the public are also required, under specific conditions [see
10 CFR 835.402(c)] to participate in internal dosimetry programs. Criteria for
participation in individual monitoring programs which include baseline radiobioassay,
routine radiobioassay and/or air sampling, radon and thoron monitoring, special
radiobioassay, and termination or task-ending radiobioassay, radiobioassay for declared
pregnant women, and confirmatory radiobioassay are covered in DOE-STD-1121-2003,
Section 5. This section of the technical standard also discusses timely receipt of
radiobioassay results. Participation in individual monitoring programs for internal
dosimetry should be in accordance with the DOE technical standard.
Section 51
Situations may arise where a decision is made to monitor radiological workers who are
not likely to receive intakes that exceed 0.1 rem (0.001 Sv) committed effective dose in a
year. Such monitoring may be useful for demonstrating compliance with
10 CFR 835.401(a) or established for other purposes. The internal dosimetry program
documentation should clearly identify those individuals or groups of individuals being
monitored for such purposes.
60 DOE G 441.1-1C
5-19-08
5.4.1 Investigation Levels/Derived Investigation Levels
Refer to DOE-STD-1121-2003, Sections 4.3 and 4.4 for a discussion of and reference
levels for Investigation Levels (ILs) and Derived Investigation Levels (DILs). Programs
should be designed in accordance with this technical standard.
Refer to DOE-STD-1121-2003, Section 4.4.1 for a discussion of factors affecting the
DIL. Additionally, section 4.4.2 provides guidance for calculating the DIL for a given
sample frequency, Section 4.4.3 discusses factors affecting the DIL for air sampling, and
Section 4.4.4 deals with supplementing routine radiobioassay programs when DIL< MDA
(technology shortfall). Programs should be designed in accordance with this technical
standard.
5.4.2 Minimum Detectable Amount (MDA)
The internal dosimetry program staff should determine the minimum detectable amount
(MDA) for each radiobioassay and BZ air monitoring method for each radionuclide
present. The MDAs should be documented in procedures and their statistical bases given
in the internal dosimetry technical basis documentation. ANSI Standard N13.30-1996,
Performance Criteria for Radiobioassay, (ANSI/HPS 1996) provides extensive guidance
on the calculation of MDAs.
As MDAs are affected by various aspects involved with individual monitoring methods,
procedures should contain descriptions of the method(s) of individual monitoring
measurements (e.g., urinalysis, fecal analysis, in vivo counting, BZ air monitoring),
analytical methodology (e.g., chemical separation followed by alpha counting), and
measurement parameters (e.g., counting time or instrument efficiency) to be used in each
component of the individual monitoring program.
Several other factors affect the method of radiobioassay used and its associated MDA.
They include:
• the possible need for improved detection capability to assess individual dose
during the special radiobioassay following an intake requiring internal dose
evaluation, due to diminishing amounts of material in compartments as time goes
on;
• the need for improved precision and accuracy if residual retention and excretion
from prior intakes interferes with the detection of additional intakes in subsequent
years;
• timeliness of results needed to manage individuals and keep subsequent intakes
low enough to avoid exceeding dose limits;
• convenience to the affected individuals;
DOE G 441.1-1C 61
5-19-08
• costs, including lost production time while individuals are participating in the
radiobioassay program; and
• the impact of the method of radiobioassay on the frequency of radiobioassay
measurements.
Where practicable, the method of individual monitoring, analytical methodology, and
measurement parameters should result in an MDA less than the corresponding DIL for all
radionuclides to which an individual might be exposed.
The methods of radiobioassay and air monitoring measurements, their MDAs, and their
accuracies should be specified in the internal dosimetry technical basis documentation,
along with a rationale or justification for the methods chosen.
Section 52
5.4.3 Frequency of Measurement
The routine radiobioassay measurement frequency depends on the radiobioassay
measurement method and associated MDA. The frequency should be chosen so that it is
unlikely that intakes by an individual in a year will result in doses exceeding one IL
without detection.
5.4.4 Detection and Confirmation of Intakes
Section 6 of DOE-STD-1121-2003 provides acceptable methods for detecting and
confirming intakes through workplace monitoring and radiobioassay. Statistical methods
for confirming that an intake has occurred are also discussed. Decisions regarding the
detection and confirmation of suspected occupational intakes of radioactive material
should be based on answers to the following questions:
• Can it be concluded reliably that the analyte is present in the measured sample
(>Lc)?
• Is the measurement result unexpected? In other words, is the result beyond the
range of values that would be expected due to environmental “background”
sources or due to previously recognized intakes?
• Is the intake (and resulting dose) implied by the measurement significant enough
(e.g., greater than the IL) to warrant follow-up measurements or investigation?
If the answer to all these questions is “yes”, then follow-up measurements or
investigation is warranted. Internal dosimetry programs should establish appropriate and
technically-based decision criteria to assist in answering these questions. Such decision
criteria should be included in the technical basis document for the site or facility.
The proper decision criteria for the first question is the Lc which is a purely statistical
concept based on an acceptable probability of “false positive” conclusions. The Lc for
62 DOE G 441.1-1C
5-19-08
radiobioassay and air sample measurements should be set by considering the acceptable
rate of false positives, the cost and consequences of false positives, and the dosimetric
consequences of false negatives. The analytical laboratory Lc should be based on a
reagent blank. Radiobioassay results above the Lc may be expected in the absence of a
new intake due to normal statistical fluctuations, non-occupational or environmental
sources, or prior confirmed intakes. In the case of environmental sources of interference
(e.g., uranium in urine) an “occupational decision level” should be established, above
which the measurement result is concluded to be statistically significant and above the
range of values that would normally be expected from environmental sources of the
radionuclide. In the case of prior confirmed intakes, an individual-specific “occupational
decision level” should be established, which takes into account the expected contribution
from the prior intakes. Finally, for each route of intake, measurement type, and
radioactive material of interest (taking into account particle size, material type, etc.),
time-dependent DILs should be established. Such DILs are based solely on dosimetric
considerations, and typically correspond to an implied intake (and corresponding dose) of
1 investigation level, i.e., 0.1 rem. This Guide has adopted the value of 0.1 rem (0.001
Sv) committed effective dose as the value which, for regulatory purposes, is regarded as
sufficiently important to justify further investigation. However, a site or facility may wish
to establish lower follow-up levels for ALARA purposes.
Section 53
If the measurement result is statistically significant, unexpected, and dosimetrically
significant, then follow-up measurements and/or an investigation should be done to
attempt to confirm or rule out the intake. An intake should be considered to be confirmed
if the three criteria above are satisfied and the measurement result is associated with a
known incident, or appropriate follow-up measurements meet the three criteria above, or
follow-up investigation indicates that an intake has occurred.
Refer to DOE-STD-1121-2003, Section 6, for additional information on the detection and
confirmation of intakes. Table 3 addresses reference levels for interpreting or responding
to intake monitoring results. Program elements which address the detection and
confirmation of intakes of radionuclides should be in accordance with the DOE technical
standard. ANSI N13.30-1996 is a suggested reference. Additionally, NCRP Report No.
84, General Concepts for the Dosimetry of Internally Deposited Radionuclides (NCRP
1985) and ICRP Publication 30, Limits for Intakes of Radionuclides by Workers (ICRP
1979), may be useful references.
5.4.5 Internal Dose Management
Internal dose management, which includes routine radiological worker dose management,
management of dose from previous intakes (work restrictions), control of dose to the
embryo/fetus, control of dose to minors and students, dose limitation, interface with the
external dosimetry program, lifetime dose control, accidental dose control, and internal
dose control after an incident, is covered in DOE-STD-1121-2003, Section 8. Individual
programs should be in accordance with the DOE technical standard.
DOE G 441.1-1C 63
5-19-08
5.4.6 Planned Special Exposures
Planned special exposures are included in an individual’s occupational dose record, but
shall not be considered when determining compliance with the occupational dose limits
of 10 CFR 835 [10CFR 835.204(a)]. In order to maintain separate records of doses
resulting from planned special exposures and routine occupational exposures, dosimetry
adequate to measure the potential doses and appropriate for the work to be performed and
specific radiological circumstances should be provided for the planned special exposure.
5.4.7 Medical Response
Medical response is addressed in DOE-STD-1121-2003, Section 10. The standard
addresses situations where internal dosimetry actions and medical treatment occur
simultaneously, the role of the health physicist in medical treatment, when to treat, how
to treat, the impact of therapy on dosimetry, and the counseling of workers. Medical
response should be handled in accordance with the DOE technical standard.
5.5 Internal Dose Evaluation
10 CFR 835 requires internal dose evaluation programs for assessing intakes of
radionuclides and for maintaining adequate worker exposure records. Technical details
and extensive references for internal dose evaluation are given in DOE-STD-1121-2003.
NCRP Report No. 84, and ANSI N13.30 are additional suggested references.
5.5.0 Required Dose Calculations
Internal doses should be evaluated for all confirmed intakes, as defined in Section 5.3.5
of this Guide. For intakes confirmed with radiobioassay results below the DIL, no further
investigation or follow-up radiobioassay are indicated. For intakes confirmed with
radiobioassay results above the DIL or exposures greater than 40 DAC-hours, follow-up
radiobioassay (if practical) and investigation should be performed.
Section 54
In the 2007 amendment to 10 CFR 835, section 835.702(b) was modified and a provision
was added regarding the recording of internal dose (committed effective dose or
committed equivalent dose). The provision allows for not recording of any positive
monitoring result estimated to correspond to an individual receiving less than 0.01 rem
(0.1 mSv) committed effective dose. Typically, this would be for very sensitive bioassay
protocols or for radionuclides which are easy to detect at very low doses (e.g., routine
tritium bioassay). The bioassay or air monitoring result used to make the estimate shall be
maintained in accordance with 10 CFR 835.703(b) and the unrecorded internal dose
estimated for any individual in a year shall not exceed the applicable monitoring
threshold at 10 CFR 835.402(c).
The extent of the investigation and the number and frequency of special radiobioassay
measurements following a suspected or confirmed intake should be determined and
documented on an individual, case-specific basis, taking into account the potential
64 DOE G 441.1-1C
5-19-08
magnitude of the intake, the effective clearance half-time, the health of the worker, and
the number of measurements needed to evaluate the internal dose.
The schedule and frequency of long-term special radiobioassay measurements to evaluate
the committed effective dose to an individual who has had an intake resulting in a dose in
excess of one IL should depend on the expected magnitude of the committed effective
dose and the likelihood of the individual receiving additional intakes.
While the investigation should be tailored to the specific individual and exposure
circumstances, the trigger levels and preliminary actions to be taken for exposures to the
different radionuclides encountered at the facility should be documented in the internal
dosimetry technical basis documentation and procedures.
5.5.1 Interpretation of Radiobioassay Data
Technical details on the interpretation of radiobioassay data including the use of
biokinetic models are given in DOE-STD-1121-2003, Section 7. Radiobioassay data
should be interpreted in accordance with the applicable portions of this DOE technical
standard.
Evaluations of committed effective dose from a specific intake should account for
expected values of radiobioassay measurements from prior confirmed intakes.
5.5.2 Evaluation of Internal Dose from Radiobioassay and Air Monitoring Data
Methods for evaluating the various doses from intakes should be specified in the internal
dosimetry technical basis documentation. The methods should be based on
recommendations, consistent with DOE requirements, given in ICRP Publications, NCRP
Reports, and ANSI standards which embody improvements and updates of the science of
internal dosimetry. Other methods may be used provided they are documented and
justified in the procedures and/or internal dosimetry technical basis documentation.
Section 55
In the calculation of internal doses less than one IL, default parameters may be used.
These parameters (e.g., intake date, deposition fractions, retention functions, organ
masses, and absorption fractions) should be based on the recommendations of the ICRP,
NCRP, other relevant technical references, or facility-specific factors as documented in
the internal dosimetry technical basis documentation. If the initial evaluation of an intake
indicates a dose in excess of 10 times an IL, individual-specific and facility-specific
factors should be used when more appropriate parameters are expected to change the
dose calculations by a factor of 1.5 or more Between 1 and 10 times the IL, either default
parameters or individual- and facility-specific parameters may be used, as deemed
appropriate and documented by the internal dosimetry staff. The basis for determining
which individual-specific and facility-specific factors are expected to change the dose
calculations by a factor of 1.5 or more should be documented in the internal dosimetry
technical basis documentation. Determination of individual retention patterns for a
worker requires participation in the special radiobioassay program and may require
DOE G 441.1-1C 65
5-19-08
temporary work restriction or reassignment to prevent subsequent intakes from
confounding the dose evaluation.
5.5.3 Periodic Reevaluation of Internal Dose
In the case of certain well-retained radionuclides (e.g., plutonium), long-term follow-up
and reevaluation of doses may be required. The internal contribution to lifetime
occupational dose should continue to be reevaluated as further radiobioassay results and
improved methods for evaluating internal dose become available.
Evaluations for general employees with prior confirmed intakes should be revised when
information demonstrates a change in the currently evaluated committed effective dose of
0.5 rem (0.005 Sv) or a factor of 1.5 of the previously assigned dose for that intake,
whichever is higher. In cases where intakes are detected or confirmed in a year
subsequent to the year of the intake, the committed effective dose should be attributed to
the known or assumed year of the intake, and all records and reports for that year should
be amended as appropriate. An acceptable approach would be for DOE sites to update
their dosimetry program to reflect the amended 10 CFR 835 tissue and radiation
weighting factors, and to assess doses using the updated factors at some predetermined
time. It is not expected that DOE sites recalculate all previously completed dose estimates
performed at that site. Note the Department did not require recalculation of previous
internal doses resulting from uranium intakes when it granted a DOE contractor an
exemption from those requirements in 10 CFR 835 requiring the use of the specified
tissue weighting factors, thus, permitting the use of the tissue weighting factors in ICRP
60 when calculating internal doses from uranium.
DOE does not encourage routine recalculation of internal doses in response to changes in
internal dosimetry methodologies such as biokinetic models, tissue weighting factors, or
improved bioassay techniques after a final dose estimate has been completed and
recorded. Internal doses calculated using technically sound and defensible methods
available at the time of the dose estimate are an acceptable way to meet the Department’s
expectations for internal dose monitoring and compliance with occupational exposure
dose limits promulgated in 10 CFR 835. However, in the process of updating
methodologies it is recommended that DOE sites should maintain close communication
with cognizant DOE personnel.
Section 56
DOE recognizes there may be unique situations in which a DOE site may consider or be
directed to reevaluate an internal dose estimate. Examples of such situations are a
response to litigation, determination that an internal dose has been incorrectly estimated,
or availability of new bioassay data. In such cases the decision to recalculate a final
internal dose estimate should be made on a case-by-case basis and consider:
• The magnitude of the expected change,
• Programmatic costs,
• Impact on compliance with dose limits,
66 DOE G 441.1-1C
5-19-08
• Documentation of the recalculated result in official records, and
• Communication of the recalculated dose to current and former workers.
To ensure compliance with record-keeping provisions of 10 CFR 835 subpart H, the
technical basis and results of determinations to recalculate a completed internal dose
assessment should be documented in official site records.
5.6 Recordkeeping and Reporting
Requirements and guidance for recording and reporting internal doses and related
information are provided in Chapter 14 and DOE-STD-1121-2003, Section 9.
Record-keeping and reporting of internal doses and related information should be in
accordance with these DOE documents.
DOE G 441.1-1C 67
5-19-08
6.0 EXTERNAL DOSIMETRY PROGRAM
Due to the types of material handled or processed, low-level, chronic occupational
exposures to external ionizing radiation are difficult to avoid, necessitating an external
dosimetry program at most DOE and DOE-contractor facilities that use, handle, or store
radioactive materials. An external dosimetry program generally consists of three
elements:
• an area monitoring program, using an array of fixed and portable devices, as
appropriate;
• an individual monitoring program, using personnel dosimeters; and
• a dose evaluation program that evaluates the data collected by the area and
individual monitoring programs to determine the magnitude of individual doses.
6.0.1 Protection and Operational Quantities
The ICRP Publication 60 dosimetric quantities adopted in 10 CFR 835 have been
designated by ICRP as “protection quantities” that are intended for defining and
calculating the numerical limits and action levels used in radiation protection standards
such as 10 CFR 835. Protection quantities provide a way to relate the magnitude of a
radiation exposure to the risk of a health effect that is applicable to an individual and that
is largely independent of the type and source (internal or external) of the radiation. In
addition the protection quantities can be easily calculated for use in planning radiological
work.
These goals are achieved using a combination of theoretical and practical considerations.
For example, absorbed dose is assumed to be averaged over a tissue or organ. Radiation
weighting factors are used to account for the biological effectiveness of various types and
energies of radiation and tissue weighting factors are used to account for the sensitivity of
various tissues to radiation induced cancer. See Appendices F and G of Chapter 16 of this
Guide for listings of values. The tissue and radiation weighting factors are based on both
biological and epidemiological studies and have been updated as new research became
available. Nevertheless, the values of these weighting factors are approximations that
account for both uncertainty in the underlying data and the need to ensure that the
protection quantities do not underestimate the true dose and hence the risk. Protection
quantities used in 10 CFR 835 include: equivalent dose, effective dose, committed
equivalent dose, committed effective dose, total effective dose, and cumulative total
effective dose.
Section 57
Because protection quantities were developed to provide an index of the risk resulting
from energy imparted to tissue by radiation, they are theoretical and not measurable.
Fortunately, it is possible to use the measurable properties of radiation fields and
radioactive materials associated with exposure to external radiation sources or intake of
radioactive materials to estimate and demonstrate compliance with the protection
quantities. These measurable quantities are called operational quantities.
68 DOE G 441.1-1C
5-19-08
Although many types of operational quantities are possible, a well characterized set of
operational quantities for assessing doses received from external exposure have been
selected by the International Commission on Radiation Units and Measurements (ICRU)
in Report 51, Quantities and Units in Radiation Protection Dosimetry. These operational
quantities have been adopted in recommendations of the ICRP and in the standards
implementing the ICRP recommendations written by the International Atomic Energy
Agency (IAEA) and the European Union (EU). In addition, the ICRP, in Publication 74,
Conversion Coefficients for Use in Radiological Protection Against External Radiation,
compared and contrasted doses determined using the ICRP system of protection
quantities with doses determined using the ICRU based operational quantities. For almost
all situations considered, doses determined with the operational quantities were greater or
equal to the doses determined using protection quantities. These operational quantities
and their relation to the protection quantities listed in the final version of 10 CFR 835 are
listed below.
Relation between protection quantities and operational quantities for individual monitoring of
external exposure
Protection quantity
Operational quantity (depth [d] in tissue [mm])
Equivalent dose to the whole body from
external sources* Hp(10)
Equivalent dose to the lens of the eye from
external sources Hp(3)
Equivalent dose to the extremity or skin
from external sources Hp(0.07)
Where Hp(d) is the personal dose equivalent at depth d in tissue
See ICRU Report 51 for the definition of Hp(d)
* Same as effective dose from external sources.
For doses resulting from intakes of radioactive materials operational quantities have been
published in ICRP, IAEA and EU documents.
Relation between protection quantities and operational quantities for individual monitoring of
doses from intakes of radioactive material
Protection quantity Operational quantity
Committed effective dose ∑∑ +
j
ingjingeffj
j
inhjinheffj IhIh ,,50,,,,50,,
Committed equivalent dose ∑∑ +
j
ingjingTj
j
inhjinhTj IhIh ,,50,,,,50,,
Where: hj,eff,50,inh is the committed effective dose per unit of radioactivity intake by inhalation (inh)
hj,eff,50,ing is the committed effective dose per unit of radioactivity intake by ingestion (ing)
hj,T,50,inh is the committed equivalent dose to a tissue (T) per unit of radioactivity intake by inhalation
hj,T,50,ing is the committed equivalent dose to a tissue (T) per unit of radioactivity intake by ingestion
Ij,inh is an intake by inhalation
Ij,ing is an intake by ingestion
j is a radionuclide
DOE G 441.1-1C 69
5-19-08
For the total effective dose, the following operational quantity is suggested.
Protection quantity Operational quantity
Total effective dose Hp(10) + ∑∑ +
j
ingjingeffj
j
inhjinheffj IhIh ,,50,,,,50,,
Section 58
In addition to the operational quantities used for individual monitoring, the following
table contains operational quantities that may be measured to characterize certain aspects
of radiation fields in the workplace.
Operational quantities for use in characterizing workplace radiation fields
Workplace measurement Suggested operational quantity
Control of effective dose H *(10)
Control of dose to the skin, the extremities
and the lens of the eye H '(0.07, Ω)
Control of dose to the lens of the eye H '(3, Ω)
Where: H *(10) is the ambient dose equivalent at a depth of 10 mm in tissue
H '(0.007, Ω) is the directional dose equivalent at a depth of 0.07mm in the ICRU sphere
H '(3, Ω) is the directional dose equivalent at a depth of 3 mm in the ICRU sphere
Ω defines the direction of the radiation field
See ICRU Report 51 for the definitions of ambient dose equivalent and directional dose equivalent
In the 2007 amendment to 10 CFR 835, DOE deleted the terms deep dose and shallow
dose. The following was added to the definition of equivalent dose: “For external dose,
the equivalent dose to the whole body is assessed at a depth of 1 cm in tissue; the
equivalent dose to the lens of the eye is assessed at a depth of 0.3 cm in tissue, and the
equivalent dose to the extremity and skin is assessed at a depth of 0.007 cm in tissue.”
The 10 CFR 835 definition of “absorbed dose” is taken from ICRP Publication 71, which
reads:
Absorbed Dose: the physical dose quantity, which is given by:
dE/dm
where dE is the mean energy imparted by ionizing radiation to the matter in a volume
element and dm is the mass of the matter in this volume element. The SI unit for absorbed
dose is joule per kilogram (J /kg) and its special name is gray (Gy).
The 10 CFR 835 definition:
Absorbed dose (D) means the average energy imparted by ionizing radiation to the matter
in a volume element The absorbed dose is expressed in units of rad (or gray) (1 rad =
0.01 gray).
While the 10 CFR 835 definition does not include the equation or the definition of the
terms in the equation as does ICRP Publication 71, it does state that absorbed dose is
expressed in units of rad, i.e., energy per mass (J/kg). Accordingly, for purposes of
70 DOE G 441.1-1C
5-19-08
compliance, the 10 CFR 835 definition is considered equivalent to the ICRP Publication
71 definition.
6.1 Implementation Guidance
This chapter provides guidance for establishing and conducting an external dosimetry
program for individuals who are likely to be exposed to external sources of ionizing
radiation. Conduct of an external dosimetry program involves determining area and
individual monitoring methods and frequencies, distributing and controlling monitoring
devices, and evaluating external doses. This chapter also addresses program organization,
administration, staffing, and training.
An external dosimetry program should include the following features:
• adequate staff provided with appropriate technical training;
• a technical basis document that explains each program element;
• procedures that address each step in the activities that determine external dose;
• criteria and methods for implementing the area monitoring program;
• criteria and methods for identifying individuals who require individual
monitoring;
• appropriate personnel dosimeter measurement methods and frequencies;
• methods for control, accountability, and safe handling of dosimeters;
• appropriate dosimetric models and default parameters for evaluating external
dose;
Section 59
• timely analysis of personnel dosimeter measurements and transmission of results,
dose evaluation, and recommendations to monitored individuals, management,
and DOE, as appropriate;
• historical records of the external dosimetry program, procedures, and results; and
• a quality assurance (QA) program that covers all steps in the activities that
determine individual external dose.
6.2 Program Management and Administration
6.2.0 General Requirements
The external dosimetry program implemented to demonstrate compliance with
10 CFR 835.402(a) shall be adequate to demonstrate compliance with the dose
limits established in Subpart C of 10 CFR 835 [10 CFR 835.402(b)] and shall be:
DOE G 441.1-1C 71
5-19-08
• accredited by the DOE Laboratory Accreditation Program (DOELAP); or
• excepted from DOELAP accreditation in accordance with the DOELAP
standards; or
• determined by the Secretarial Officer responsible for environment, safety
and health to have performance substantially equivalent to that of programs
accredited under the DOE Laboratory Accreditation Program for Personnel
Dosimetry [10 CFR 835.402(b)].
Guidance for achieving accreditation or exception from accreditation under the
DOELAP Program is provided in DOE-STD-1111-98. DOE will consider
requests for other program approvals on a case-by-case basis. Programs
excepted from DOELAP under the specific exception criteria established in the
governing documents of that program are considered to be operated in
conformance with the program. However, these programs would not be
considered to be in conformance with DOELAP if conditions established in
granting that exception, such as maintenance of alternate accreditation, were not
maintained by the contractor.
The specification of accreditation requirements only for programs implemented to
demonstrate compliance with 10 CFR 835.402(a) does not reflect an intent to
provide a lesser degree of protection to individuals unlikely to receive doses
exceeding the regulatory monitoring thresholds, nor does it reflect DOE’s intent for
it’s contractors to establish two separate individual monitoring programs (i.e., an
accredited program for individuals likely to exceed the regulatory monitoring
thresholds and a non-accredited programs for individuals who are unlikely to
exceed these thresholds). Rather, those individuals who are unlikely to exceed the
regulatory monitoring thresholds are provided an adequate degree of protection by
the various engineering and administrative controls that limit their doses.
Implementation of a comprehensive area monitoring program verifies the
effectiveness of these controls. When an accredited dosimeter program already
exists and management of any given facility chooses to provide monitoring for
those individuals who are unlikely to exceed the regulatory monitoring threshold,
consideration should be given to using the accredited program. This will obviate the
need to implement two dosimeter programs, one accredited and the other not. In
addition, it will avoid giving workers who are not required to be monitored the
impression that they are being provided a lesser degree of protection. However, this
does not imply that the monitoring program for those unlikely to exceed the
monitoring threshold must be accredited.
Sections 401 - 403 of 10 CFR 835 establish specific monitoring requirements for
areas and individuals. 10 CFR 835 also establishes requirements for preserving
dosimetric records and reporting external radiation doses to individuals.
Section 60
72 DOE G 441.1-1C
5-19-08
6.2.1 Organization, Staffing, and Facilities
6.2.1.0 Organization
The external dosimetry program should be administered by the radiological control
organization under the leadership of the radiological control manager. When elements
of the external dosimetry program are performed by a subcontractor, the radiological
control organization should establish contractual standards and assessments that
ensure the subcontractor meets all applicable requirements in 10 CFR 835, the
documented radiation protection program, DOELAP standards, and the technical
basis document.
6.2.1.1 Staffing
Management should maintain an adequate staff with the necessary expertise and skill to
implement the external dosimetry program. For staff members responsible for evaluating
external doses, management should establish minimum qualification standards that
include both experience and education requirements. Additional guidance on education,
skills, and training is provided in Chapter 3 and DOE STD-1107-97, KNOWLEDGE,
SKILLS, AND ABILITIES FOR KEY RADIATION PROTECTION POSITIONS AT
DOE FACILITIES (DOE 1997a). Personnel should be familiar, at a level commensurate
with their assigned responsibilities, with relevant external dosimetry literature and related
recommendations of national and international scientific organizations.
6.2.1.2 Facilities and Resources
Computational facilities and software tools used by external dosimetry personnel should
be adequate for performing calculations required for dose evaluation. A library of
handbooks, reference materials, scientific publications, applicable regulations and
guidance documents should be readily available.
6.2.2 Technical Basis Document
A technical basis document should be developed for the external dosimetry program to
provide (or provide reference to) the regulatory, scientific, and technical foundation of the
program. The technical basis document should include:
• the methods used for evaluating external doses from workplace and individual
monitoring data and the technical basis for those methods;
• justification of categories selected for participation in and exception from
DOELAP personnel dosimeter performance testing;
• QA procedures for dosimeters that are outside of the DOELAP testing protocol, as
appropriate;
DOE G 441.1-1C 73
5-19-08
• the physical characteristics of external radiation to be monitored, methods for
calculating external doses, methods for documenting calculations, dose evaluation
quality assurance, and procedures for recording and reporting external dose
results;
• the methodology used in determining the dose of record when multiple dosimeters
are used and when dosimeters are relocated;
• individual monitoring methods, their lower limits of detectability, and monitoring
intervals, along with a rationale or justification for the methods and intervals
chosen;
• calibration models, parameters, assumptions, and default values used in
dosimetric modeling and evaluation; and
• statistical methods for evaluating dosimeter data, using appropriate controls,
identifying above-background values, and analyzing trends.
The technical basis document should be reviewed periodically and updated as necessary
to ensure that it remains appropriate for current conditions. The technical basis document
should be handled as a controlled document and retained as an RPP record.
6.2.3 Procedures
Section 61
10 CFR 835 requires that written procedures be developed and implemented as necessary
to ensure compliance, commensurate with the radiological hazards created by the activity
and consistent with the education, training, and skills of the individuals exposed to those
hazards (10 CFR 835.104). All functions of the external dosimetry program should be
specified in written procedures that provide for appropriate quality control and QA
measures. The procedures should be consistent with 10 CFR 835, the DOELAP technical
standards, and the technical basis document. In summary, the procedures should provide
the following information:
• methods and requirements for measuring, evaluating, and recording external dose;
• methods for consistent collection of workplace and personnel monitoring data, its
evaluation, documentation of results, and records maintenance;
• components and reporting structure of the external dosimetry program;
• responsibilities of line management and members of the dose evaluation group;
and
• elements of the area monitoring program that are germane to external dose
determination.
Additional guidance on written procedures is provided in Chapter 3.
74 DOE G 441.1-1C
5-19-08
6.2.4 Quality Assurance
Internal audits shall be conducted such that all functional elements are reviewed no
less frequently than every 36 months and shall include program content and
implementation (10 CFR 835.102). External peer-review by qualified individuals, on
a periodic basis, is also recommended. See Chapter 3 for further information on
internal audits.
6.3 Area Monitoring Program
The area monitoring program supplements the individual monitoring program by
providing a prospective assessment of radiological conditions, thus facilitating decisions
regarding postings, access controls, work authorizations, and individual monitoring, and
providing back-up data for use in individual dose evaluations. Because of the need to
evaluate individual external doses (prospectively and retrospectively) from contained
sources, airborne radioactive material, and surface contamination, the area monitoring
program should include methods for assessing the degree of hazard arising from each of
these hazards to which individuals may be exposed. Guidance for implementing surface
contamination and airborne radioactivity monitoring programs is provided in Chapters 10
and 11. Guidance for implementing area monitoring for other external sources of
radiation is provided below. For each element of the area monitoring program, additional
guidance is provided in Chapter 5 of the RCS.
6.3.0 Monitoring Instruments and Devices
External radiation monitoring instruments and devices include both fixed and portable
instruments that provide real-time indication of radiation levels and passive monitoring
devices (such as TLDs and radio-sensitive film) that provide a retrospective indication of
radiological conditions. Guidance on portable instrument selection, calibration, and
checking for operability is provided in Chapter 9. While Chapter 9 addresses portable
instruments, many of the concepts and practices discussed in Chapter 9, and in the
referenced consensus standards, may be applicable to fixed instruments.
Although fixed instruments provide the advantage of continuous operation with little or
no attention, their application is limited by their lack of mobility. Fixed instruments
should be used to monitor areas and installations:
Section 62
• having a known and relatively predictable operation where little variation in the
radiological hazards is expected;
• where monitoring of an access point (and possible provision of an alarm function)
is desirable to warn individuals of hazards in the area;
• where it is desirable to continuously monitor an area to detect changes in
radiological conditions, possibly as a result of an unplanned change in process
functions;
DOE G 441.1-1C 75
5-19-08
• where continuous monitoring and alarm functions are necessary to prevent
unplanned exposures; and
• as necessary to provide input into interlocks, control devices, and alarm systems
that are dependent upon or that control the operation being monitored
Portable instruments are most appropriate for use in performing prospective monitoring
for the purposes of work planning, radiological condition verification, facility integrity
verification, and operational assessments. The quality and utility of the data provided by
portable instruments are highly dependent upon the knowledge and skills of the user.
Because of these important applications and significant vulnerabilities, portable
instruments should be used only by trained individuals (such as specifically-trained
radiological workers and radiological control technicians). Passive monitoring devices
(e.g., area monitoring TLDs) should be placed in areas surrounding radiological areas to
verify that doses in these areas do not exceed the individual monitoring threshold. Passive
monitoring devices should be placed where they will be exposed to radiation fields
similar to those affecting individuals frequenting the area, but should be protected from
loss or vandalism. The use of passive monitoring devices to characterize radiation fields
as a part of pre-job planning should also be considered.
6.3.1 Performance of Area Radiation Monitoring
10 CFR 835 defines radiation and high radiation areas in terms of the radiation levels at a
distance of 30 centimeters from the source or from any surface penetrated by the
radiation. Similarly, 10 CFR 835 defines very high radiation areas in terms of the
radiation levels at a distance of 100 centimeters. Therefore, area radiation monitoring
should be performed at these distances (consistent with facility hazards) to ensure
compliance with the 10 CFR 835.603 area posting requirements. However, actual and
likely exposure conditions should be considered when performing monitoring for task
planning, hazard analysis or dose assessment should also include consideration of. If an
individual is likely to linger at a distance of several feet from a shield wall, use an
obvious travel path between stations, or work within a few inches of a radiation source,
measurements should be made at those locations (and recorded as such) to provide
representative information. Such monitoring should be performed as necessary to ensure
compliance with 10 CFR 835.401(a). Methods used in performing area radiation
monitoring should also be adequate to identify localized variations in radiation levels to
facilitate dosimeter placement and individual exposure reduction actions.
Important variables that should be considered for inclusion in procedures and training
include instrument selection, operation, functional testing, detector orientation, response
time, operational limitations, source-to-detector distance considerations, and
documentation requirements.
6.3.2 Allowance for Physical Characteristics
Section 63
The physical characteristics of the radiation field present should be considered in the
design of the monitoring program and in the evaluation of external dose equivalent.
76 DOE G 441.1-1C
5-19-08
These characteristics include radiation quality, energy, fluence rate, and direction of
incidence. If certain characteristics are not known, the assumed values used as the basis
for the area monitoring program design should be documented in the technical basis
document. For instance, if monitoring for beta particles is performed, but the energies are
not known, the energy assumed and rationale used for calibration purposes should be
recorded.
6.3.3 Recourse for Technology Shortfall
The technology may not be available to perform area monitoring for some types of
radiation at levels indicative of the monitoring requirements. If the performance
objectives cannot be achieved for this reason, the facility should
• use the best practicable monitoring methods, and
• implement enhanced design, operational controls, personnel protection
equipment, and procedures to control external exposures.
6.4 Individual Monitoring Program
This section discusses program features for individual monitoring, compensatory actions
for lost, damaged, or contaminated dosimeters, nuclear accident dosimetry, and dosimetry
for planned special exposures.
6.4.0 Establishing the Need for Individual Monitoring
It is usually not necessary for all individuals at a facility to wear dosimeters unless there
is a documented technical basis. Unnecessary issuance of dosimeters should be avoided.
If an individual does not enter areas where there is a likelihood of external exposure
resulting in a dose near or in excess of the regulatory monitoring thresholds, issuance of a
dosimeter to that individual is discouraged. For reasons of practicality and uniformity,
decisions regarding those individuals to whom dosimeters are issued should be made on
the basis of work group affiliation, type of work to be performed, and/or areas to be
entered. There is generally no need to perform calculations regarding individual dose
expectations to support decisions regarding the provision of individual dosimeters. The
issuance of dosimeters to concerned individuals should not be a substitute for providing
information, training, access controls, and a comprehensive area monitoring program.
The criteria for the selection of individuals to be monitored should be documented in the
technical basis document.
10 CFR 835 establishes individual monitoring requirements based on the likelihood of an
individual receiving a dose in excess of a regulatory monitoring threshold. In determining
the likelihood of potential exposures, the use of professional judgment is necessary. This
judgment should include consideration of the following:
• areas to which the individual will have access;
DOE G 441.1-1C 77
5-19-08
• the individual's previous occupational dose during the current year;
• activities taking place in the areas to be entered;
• restrictions on areas entered or time in these areas;
• design basis radiological conditions in the areas to be entered;
• documentation of actual radiological conditions in the areas to be entered,
obtained through prior individual and area monitoring; and
• potential for changes that may affect the radiological conditions.
Except for provisions for nuclear accident dosimetry, it is not necessary to include
consideration of accidents or emergencies, because these events are not considered
"likely."
Section 64
There are many instances where groups conduct site tours. A common practice is to only
monitor the individual conducting the tour. This may be appropriate depending on the
areas being toured and the classification of the individuals on the tour. For example, this
practice is appropriate for tours limited to members of the public touring well
characterized areas with no measurable radiation levels above background. If it is later
found that there was an unexpected exposure, doses may be evaluated from the dosimeter
of the individual conducting the tour. This is consistent with RCS Section 511, which
states that DOE discourages the issuance of dosimeters to individuals other than those
entering areas where there is a likelihood of external exposure in excess of the monitoring
thresholds given in 10 CFR 835.
If the tour group consists of individuals receiving occupational exposure (i.e., situations
where being on the tour is part of an individual’s job function, such as tours by external
auditors or subject matter experts) and the tour could result in individual receiving
measurable doses, then an evaluation should be made on the need for monitoring the
individuals on the tour. The evaluation should consider the expected magnitude of any
dose received during the tour and during subsequent work as well as consideration of
previous occupational doses received during the year, and individual dose monitoring
requirements of 10 CFR 835 § 402. Where this evaluation cannot be accurately
performed by the site because of complexity or lack of dosimetry information (e.g., the
individual has visited, or may visit, more than one site or has not received dosimetry
reports) each individual should be monitored.
When the tour guide carries the dosimeter for the tour, each member of the tour should be
told that their dose will be assigned based upon the tour guide’s dosimeter and given the
opportunity to request an individual dosimeter be issued to that individual.
Individuals should not wear a dosimeter at multiple sites without appropriate
administrative controls. If an individual is allowed to wear his or her resident site issued
78 DOE G 441.1-1C
5-19-08
dosimeter at another site (in lieu of being issued a dosimeter at the visited site),
acceptable methods to meet the reporting requirements include:
• Processing the dosimeter at the conclusion of each site visit;
• Issuing a self-reading dosimeter and using the results to assess dosimeter of
record results by location; and
• Attributing dose only to those sites where the monitoring is performed in
accordance with 10 CFR 835.402.
The method selected should have a sound technical basis and be consistent with external
dosimetry technical basis documentation for all affected sites, The RPP and the external
dosimetry technical basis documentation should also discuss the geographic boundaries
of the site where that method will be applied.
6.4.1 Routine Monitoring of Individual External Doses
Individual monitoring shall be performed for those individuals likely to receive external
doses exceeding the monitoring thresholds provided in 10 CFR 835 and for individuals
entering high radiation or very high areas [10 CFR 835.402(a)]. The frequency of
collecting and processing personnel dosimeters depends on the measurement method and
associated lower limit of detectability. The collection/processing frequency should be
chosen so that it is unlikely that an individual will receive a dose equal to or greater than
the values listed in 10 CFR 835.402(a) from external radiation without detection and
quantification. The specific physical characteristics of the radiation field should be
considered in choosing the measurement method. These characteristics include radiation
type, quality, energy, fluence rate, and direction of incidence. If these characteristics are
not quantified, conservative assumptions should be used until further information is
available, and should be stated in the technical basis document.
Section 65
6.4.1.0 Whole Body Monitoring
10 CFR 835.402(a) requires monitoring for individuals likely to exceed the specified
whole body dose threshold as a result of exposure to external radiation sources. For
radiological workers this is an effective dose of 0.1 rem (0.001 Sv) or more in a year. 10
CFR 835.2(b) specifies that for external dose, the equivalent dose to the whole body is
assessed at a depth of 1 cm (1000 mg/cm2) in tissue. It also specifies that equivalent dose
to the whole body may be used as effective dose for external exposures
[10 CFR 835.2(b), Equivalent dose and Effective dose].
DOELAP accredited monitoring performed under the previous (10 CFR 835; 1993 -
1998) definitions (i.e., where deep dose equivalent from external exposures was allowed
to be used as the effective dose equivalent to the whole body and where the effective dose
equivalent to the whole body was evaluated at a tissue depth of 1 cm (1000 mg/cm2) is
considered acceptable monitoring to meet these definitions.
DOE G 441.1-1C 79
5-19-08
For individuals who require individual monitoring, external dose should be determined
using such devices as thermoluminescent dosimeters, track-etch dosimeters, or
radiation-sensitive film. The dosimeter should be worn to provide a measurement of the
maximum dose received at any location on the whole body. When the whole body is
exposed fairly uniformly, the location should be on the front of the torso between the
neck and waist. For non-uniform irradiation, multiple dosimeters should be used or the
primary dosimeter should be relocated to the area receiving the highest dose. Guidance
on the use of multiple dosimeters and dosimeter relocation is provided later in this
chapter.
6.4.1.1 Lens of the Eye Monitoring
The equivalent dose to the lens of the eye is assessed at a depth of 0.3 cm in tissue
(300 mg/cm2) [10 CFR 835.2(b), Equivalent dose].
For uniform exposures, a measurement taken in the torso region is sufficient. For
non-uniform exposures that would result in an individual receiving a significantly higher
dose to the lens of the eye than to the whole body, such as access to or near reactor
beams, X-ray machines, sources of beta radiation, and shield penetrations, the dose
should be measured near the eye, such as with a dosimeter worn on the side of the head
or forehead.
For beta particles with maximum energies less than about 3.5 MeV, the dose limit to the
skin is more restrictive than that for the lens of the eye. At higher energies, the lens of the
eye dose limit dominates. Therefore, at beta energies below 3.5 MeV, if it can be shown
that skin monitoring is not required, then it follows that lens of the eye monitoring is also
not required (See International Commission on Radiation Units and Measurements
(ICRU) Report No. 43, Determination of Dose Equivalents from External Sources - Part
2 [ICRU 1988)]. Protective eyewear using 1/10-inch (0.254 cm) of acrylic plastic will
completely attenuate beta particles with maximum energies < 800 KeV. This covers most
beta-emitting isotopes with the exception of P-32, Y-90, and Pa-234. See the Radiological
Health Handbook (BRH 1970).
6.4.1.2 Skin and Extremity Monitoring
Exposure to the extremities and skin from external radiation (except for non-uniform
exposure of the skin as discussed in Section 6.4.1.4 ) shall be assessed at a depth of 0.007
cm (7 mg/cm2) in tissue [10 CFR 835.2(b), Equivalent dose].
Section 66
Monitoring for skin exposure is usually performed in conjunction with that for the
effective dose to the whole body using a single whole body dosimeter. This method is
adequate for uniform or nearly uniform fields. Guidance on the use of extremity
dosimeters is provided later in this chapter.
When monitoring the extremities, if the most exposed location is not directly monitored,
a field correction factor may be applied based the gradient between the location
monitored and the most exposed location (or the equivalent dose at contact if there is
80 DOE G 441.1-1C
5-19-08
direct source-to-skin or -extremity contact). Because of difficulties associated with
inducing an albedo effect necessary for proper function of commonly-available neutron
dosimeters, monitoring for neutron dose to the extremities can present special challenges
to the external dosimetry program. Neutron dose to the extremities may be determined by
a variety of methods:
• direct measurement by neutron sensitive dosimeters, when available;
• barring sufficient neutron energy information, or for ease in implementation, a
factor of two (i.e., a doubling) may be applied to neutron doses calculated using
the existing neutron quality factors;
• application of a gamma dose to neutron dose correction factor determined through
the measurement of the gamma and neutron dose rates incident to the affected
extremities; or
• application of a whole body dose to extremity dose correction factor determined
through measurements of the neutron dose rates incident to both the whole body
and the affected extremities.
Justification for the choice of dosimeter and placement of dosimeter and results of field
gradient measurements should be provided in the technical basis document.
6.4.1.3 Embryo/Fetal Monitoring
Following the pregnancy declaration, a declared pregnant worker should continue to wear
her dosimeter in the normal manner if she will be entering areas or performing work for
which individual monitoring is required. If she is in an area where the dose is likely to
approach 50 millirem (0.5 mSv) in a month, a supplemental dosimeter should be worn to
obtain a monthly estimate of the dose. If she is exposed to localized sources of radiation,
the supplemental dosimeter should be worn on or near the abdomen.
Guidance for determining the dose to the embryo/fetus is provided in Chapter 8.
6.4.1.4 Non-Uniform Radiation Fields
When individuals will be exposed to radiation in a manner that will result in significantly
non-uniform doses to various areas of the whole body, multiple dosimeters should be
issued or the primary dosimeter should be relocated to the area of the whole body likely
to receive the highest dose. Such a situation may result from an irregular distribution of
radiation sources in the area, a continued positioning of the individual that causes an
irregular radiation exposure to the body, or the effects of personal protective equipment
(e.g., lead aprons) or other shielding devices that do not protect all portions of the whole
body in a uniformly effective manner. Multiple dosimeters should be used to assess
whole-body dose when radiation fields vary by > 50% over the whole body and the
anticipated dose to the maximally-exposed area is > 100 millirem (1 mSv) (equivalent
dose to the whole body) or 1 rem (0.01 Sv) (equivalent dose to the skin or extremity)
DOE G 441.1-1C 81
5-19-08
Section 67
during the dosimeter issue period. The technical basis document should provide details
regarding the basis for dosimeter location(s) under non-uniform exposure conditions.
Preliminary judgments on the need for multiple dosimeters and placement of multiple
dosimeters should be made from direct exposure rate surveys with portable monitoring
instruments or monitoring with dosimeters placed on phantoms. Multiple dosimeters may
be used at any time to provide more detailed information for estimates of whole body
dose. Additional guidance on the use of multiple dosimeters is provided in ANSI/HPS
N13.41, Criteria for Performing Multiple Dosimetry (ANSI/HPS 1997a). Guidance on
the evaluation of individual dose from multiple dosimeter results is provided later in this
chapter.
When the radiation field is well characterized and the individual's orientation is known,
relocation of the primary dosimeter may be preferable to issuance of multiple dosimeters.
If dosimeter relocation is desirable, the individual's dosimeter should be relocated to the
portion of the whole body likely to receive the highest dose. Dosimeter relocation should
be conducted in conformance with management-approved procedures or work
authorizations, such as radiological work permits. Dosimeter relocation should not be
performed by individuals without written authorization.
Multiple dosimeters should be placed at locations on the body likely to receive the
highest dose equivalent. Common locations for multiple dosimeter placement include the
head, chest, back, gonads, upper arms, and upper legs. If multiple dosimeters are used,
the routine whole body dosimeter should be replaced with the set of multiple dosimeters
during the multibadging activity. This keeps the normal dosimetry on its regular
processing cycle and eliminates the possibility of "double counting" dosimetry results.
6.4.1.5 Supplemental Dosimeters
Supplemental dosimeters include, but are not limited to, electronic dosimeters, pocket
dosimeters, and other self-reading, alarming dosimeters. Any individual entering a high
radiation area or very high radiation area shall wear a supplemental dosimeter or be
monitored by another means capable of providing an immediate estimate of that
individual’s integrated equivalent dose to the whole body during the entry (e.g., stay-time
tracking) [10 CFR 835.502(a)].
Supplemental dosimeters should be read periodically while in use. The range and energy
dependence of supplemental dosimeters, particularly to low-energy beta and X-ray
radiation, should be considered in determining their applicability. Supplemental
dosimeters with a limited range should be selected with the lowest range applicable for
the anticipated exposure. Chapters 3 and 5 of the RCS provide additional guidance on the
use of supplemental dosimeters.
6.4.2 Lost, Damaged, or Contaminated Dosimeters
An individual whose dosimeter is lost, damaged, or contaminated should place work in a
safe condition, immediately exit the area, and report the occurrence to the radiological
control organization.
82 DOE G 441.1-1C
5-19-08
Reentry of the individual into radiological areas should not be made until a review has
been conducted, the individual has been issued a new dosimeter, and management has
approved reentry. The review may be as simple as a documented survey showing the
dosimeter not to be contaminated, in which case the worker may go back to work
immediately. Otherwise, a review should include a dose evaluation to replace the results
of the lost, damaged, or contaminated personnel dosimeter and should determine if work
can continue while an investigation is in progress.
Section 68
6.4.3 Nuclear Accident Dosimetry
Nuclear accident dosimetry shall be provided to individuals in installations possessing
sufficient quantities of fissile material to potentially constitute a critical mass, such that
the excessive exposure of individuals to radiation from a nuclear accident is possible
[10 CFR 835.1304(a)]. Nuclear accident dosimetry shall include:
• a method to conduct initial screening of individuals involved in a nuclear accident
to determine whether significant exposures to radiation occurred;
• methods and equipment for analysis of biological materials;
• a system of fixed nuclear accident dosimeter units; and
• personal nuclear accident dosimeters [10 CFR 835.1304(b)].
Initial screening methods should include measurements of activation products in and on
the bodies of exposed individuals (e.g., sodium-24 in the body, activation of jewelry)
and/or evaluation of individual locations during the accident, as appropriate. Methods and
equipment for analysis of biological materials should include appropriate counting
systems maintained in operable condition and sample collection and preparation
processes. Acceptable methods for implementing a nuclear accident dosimetry program
are described in ANSI N13.3, Dosimetry for Criticality Accidents (ANSI 1988).
Additional guidance is provided in Chapter 5 of the RCS.
Placement of fixed nuclear accident dosimeter units should consider the nature of the
operations, structural design characteristics, accessibility of areas to personnel, and
recovery of units after a criticality accident. The number of fixed nuclear accident
dosimeter units, their locations, the effect of intervening shielding, and an analysis
demonstrating the above performance criteria should be documented in the technical
basis document.
6.4.4 Planned Special Exposures
Planned special exposures are included in an individual's occupational dose record, but
shall not be considered when determining compliance with the occupational dose limits
[10 CFR 835.1(b)]. In order to maintain separate records of doses resulting from planned
special exposures and routine occupational exposures, dosimeters adequate to measure
DOE G 441.1-1C 83
5-19-08
the potential doses and appropriate for the work to be performed and specific radiological
circumstances should be provided for the planned special exposure.
6.4.5 Personal Protective Equipment
Use of personal protective equipment (such as shielded aprons or other clothing items)
may present special challenges in the placement of personnel dosimeters and the
determination of the dose equivalent. Use of such items may create non-uniform radiation
field conditions similar to those discussed in Section 4.3.2 of this Guide. If so, the
placement of dosimeters and determination of the individual dose equivalent should be
conducted consistent with that guidance. If the effect of personal protective equipment is
not significant enough to create a non-uniform radiation field as described in the
technical basis document, then the dosimeter should be placed on the area of the body
likely to receive the highest equivalent dose. The effect of the personal protective
equipment on albedo effects that are critical for the proper function of neutron dosimeters
should also be considered.
6.5 External Dose Evaluation
Radiation protection requirements are expressed in terms of limiting values of equivalent
dose to individuals. The limiting values for equivalent dose in 10 CFR 835 are specified
as total effective dose to the whole body and equivalent dose for other organs and tissues.
Section 69
Methods for evaluating the various doses from external exposures should be based on
recommendations given in International Commission on Radiological Protection (ICRP)
Publications, NCRP Report No. 91, Recommendations on Limits for Exposure to Ionizing
Radiation (NCRP 1987b), and other reports of the NCRP that address improvements and
updates of the science of external dosimetry. Other methods may be used provided they
are documented and justified in the procedures and/or technical basis document. The dose
calculation methodology shall use the radiation weighting factors and tissue or organ
weighting factors in the definition section of 10 CFR 835 [10 CFR 835.203(b)].
6.5.0 Required Dose Calculations
Records shall be maintained to document the doses received by all individuals monitored
in accordance with 10 CFR 835.402 and to document doses received as a result of
planned special exposures, doses exceeding the monitoring thresholds of 835.402, and
authorized emergency exposures [10 CFR 835.702(a)]. The following quantities shall be
recorded for external dose received during the year:
• effective dose from external sources of radiation (equivalent dose to the whole
body may be used as effective dose for external exposure)
[10 CFR 835.702(c)(3)(i)];
• equivalent dose to the lens of the eye [10 CFR 835.702(c)(3)(ii)];
84 DOE G 441.1-1C
5-19-08
• equivalent dose to the skin [10 CFR 835.702(c)(3)(iii)]; and
• equivalent dose to the extremities [10 CFR 835.702(c)(3)(iv)].
For airborne radionuclides that pose an external exposure hazard, the derived air
concentration (DAC) values in Appendix C of 10 CFR 835 shall be used to control
exposure to airborne radionuclides [10 CFR 835.209(a)]. See Appendix C of Chapter 16
of the Guide for a listing of values. The technical basis document should note which
radionuclides could be present and whether the individual dosimeter responds correctly to
the quality of the radiation or whether immersion exposures should be calculated
separately and added to dosimeter results. When it is necessary to apply airborne
radioactivity monitoring results to individual external dose assessment, such applications
should include consideration of the concentration of the contaminant in the workplace
and the duration of the exposure (i.e., maintenance of records of DAC-hours of
exposure). The air immersion DAC values in 10 CFR 835 Appendix C were calculated
for a continuous (2,000 hours per year), non-shielded exposure via immersion in a
semi-infinite atmospheric cloud. 10 CFR 835 allows modification of the DAC values
contained in Appendix C to allow for submersion in a cloud of finite dimensions.
Personnel dosimeters should be calibrated to monitor for dose directly or indirectly
through the use of a calibration factor. Dosimetry services that process dosimeters
typically report personnel doses in units or subunits of rem and no further calculations
need be performed unless modifying factors are applied.
When neutron monitoring is performed, the neutron equivalent dose is added to the non-
neutron equivalent dose to determine the total equivalent dose to the whole body, and
added, as applicable, to the extremity equivalent dose, and/or the lens of the eye
equivalent dose. Varying neutron energy spectra are encountered at field locations,
depending on the original energy of the neutrons and the degree of moderation and
attenuation. These neutron energy spectra may not be representative of the energy spectra
used in DOELAP. If this situation exists, specific field correction factors should be
developed and used to adequately assess the neutron equivalent dose. The development
and use of the field correction factors should be reflected in the technical basis document.
Examples of methods for developing field correction factors can be found in Personnel
Neutron Dose Assessment Upgrade (PNL 1988b) and in Neutron Dose and Energy
Spectra Measurements at Savannah River Plant (PNL 1987).
Section 70
The adoption of ICRP Publication 60 dosimetric quantities and units results in revising
the assessment of neutron exposures from using the quality factors to using radiation
weighting factors. For the energy range of 0.1 to 2 MeV the radiation weighting factor is
approximately a factor of two greater than the corresponding quality factor (from 10 to
20). Specific field correction factors may be developed and used to adequately assess the
neutron equivalent dose. In lieu of this approach, a scaling factor may be developed and
used. The scaling factor may be based on the neutron spectrum and taking a ratio of the
differences between the quality factor and radiation weighting factor for each neutron
energy grouping. Barring sufficient neutron energy information, or for ease in
implementation, a factor of two (i.e., a doubling) may be applied to neutron doses
DOE G 441.1-1C 85
5-19-08
calculated using the existing neutron quality factors. DOE will continue to evaluate
neutron dose assessment using radiation weighting factors and will provide additional
guidance as more information is obtained.
DOELAP is working towards adopting standards consistent with ICRP Publication 60
dosimetric quantities and units. It is anticipated that this change will be effective prior to
the 10 CFR 835 amendment compliance due date of July 8, 2010. This should address
issues relating to use of personnel monitoring devices to assess neutron exposures. Prior
to DOELAP updating its requirements, sites may consider implementing the above
mentioned scaling factor or a comparable approach for assessing neutron exposures from
personnel monitoring devices.
In addition, sites may find it advantageous for certain applications to continue calibrating
portable neutron survey instruments using the existing neutron quality factors. For
example, neutron calibrations using existing neutron quality factors may correlate better
with surveys conducted to meet Department of Transportation requirements. If this
approach is taken, the above mentioned scaling factor or a comparable approach may
then be applied to portable neutron survey instrument results and used for controlling and
limiting individual neutron exposures.
6.5.1 Special Considerations
Personnel dosimeter measurements are the preferred source of data for evaluating the
external dose of individuals likely to exceed the monitoring thresholds. Area monitoring
data and other personnel monitoring data should be used to evaluate external dose if
personnel dosimeter measurements are not feasible or are not available. When personnel
dosimeter measurements are not available, a dose evaluation should be performed for that
period. The dose evaluation should be based on personnel dosimeter results from other
individuals in the same area, on previously recorded doses (provided no significant
changes in exposure rates would be anticipated), or on area monitoring results of the
ambient radiation levels. These estimated or assigned doses shall be clearly recorded and
maintained as such [10 CFR 835.702(a) and (g)]. When area monitoring results are
used to estimate individual dose, the results of surveys, measurements and calculations
used to determine individual occupational exposure from external sources shall be
recorded [10 CFR 835.703(b)].
Section 71
When an individual is provided multiple dosimeters, the dose measured by the highest
responding dosimeter on the whole body should be assigned as the whole body dose of
record. When multiple dosimeters are employed more than once during the year,
dosimeter results may be summed by location and the highest total assigned as the whole
body dose of record. However, sufficient records should exist to demonstrate that the
dose to portions of the whole body between the monitoring locations did not exceed that
recorded for the monitoring location. For example, if both the left and right upper arms
were monitored, adequate records should be maintained to demonstrate that the dose to
the head and torso, which may have been exposed as a result of exposure to both arms,
did not exceed the dose to either upper arm.
86 DOE G 441.1-1C
5-19-08
If tissue weighting factors are used to calculate effective dose from external radiation
fields, the weighting factors in 10 CFR 835.2 shall be used [10 CFR 835.203(b)]. If
necessary, a compartmentalization methodology, such as that recommended in ANSI/HPS
N13.41 (ANSI/HPS 1997) modified to use the 10 CFR 835 specified tissue weighting
factors, may be applied to the multiple dosimeter results. A calculation of this type
provides a better representation of the risk to the monitored individual. Whatever
methodology is selected, all multiple dosimeter results shall be recorded
[10 CFR 835.702(a) and (g)].
When supplemental dosimeters are used, the results should be compared to the results
from the primary dosimeter issued to the same individual (if the issue periods for the
primary and supplemental dosimeters are the same). If the dose results differ by >50%
from the primary dosimeter and the dose from the primary dosimeter is >100 millirem (1
mSv), an investigation should be initiated to explain the difference.
10 CFR 835.205 places additional requirements on evaluating and recording doses from
non-uniform exposures of the skin from X-rays, beta radiation, and/or radioactive
materials on the skin, including hot particles. The technical basis document should
provide the basis for the action level used to identify the need for such evaluations.
Decisions regarding the appropriate action levels should be based upon such factors as
the likely magnitude of events resulting in non-uniform exposure of the skin, the
likelihood of repeated events, and potential resulting doses (total of all events). An action
level of 100 millirem (1 mSv) for the evaluation of skin dose for general employees is
recommended. Further information regarding hot particles can be found in NCRP Report
No. 106, Limit for Exposure to "Hot Particles" on the Skin (NCRP 1989).
For non-uniform exposures of the skin, the assessment of the exposed area should be
recorded with the equivalent dose to the skin. Non-uniform exposures of the skin of the
extremities from X-rays, beta radiation, and radioactive materials on the skin, including
hot particles, should be assigned to the extremity, not the skin. If the non-uniform
equivalent dose to the skin does not exceed 1 rem (0.01 Sv), then recording of the dose is
not required [10 CFR 835.702(b)].
When an individual has been monitored for extremity exposure at some time during the
calendar year, but is not monitored for the entire year, the equivalent dose to the skin or
extremity from the whole body dosimeter should be used as the extremity dose of record
for periods when extremity dosimeters are not worn.
Section 72
If it is necessary to determine an equivalent dose to the lens of the eye in the absence of
reliable monitoring data (i.e., in the absence of properly calibrated lens of the eye
dosimeters), the equivalent dose to the skin or extremity should be used as an
approximation of the lens of the eye dose or appropriate dose conversion factors should
be used to convert the dosimeter reading to the lens of the eye dose. Appropriate dose
conversion factors may be found in ICRP Publication 74, Conversion Coefficients for Use
in Radiological Protection Against External Radiation (ICRP 1996), or peer-reviewed
journals or may be determined locally through performance of a series of tests using
dosimeters with different filters.
DOE G 441.1-1C 87
5-19-08
In the case of a large dose, actual or suspected, quick initial estimates should be made
based on stay time and exposure rate. These estimates should be used to limit further
external dose until dosimeter and bioassay results are available.
6.6 Recordkeeping and Reporting
10 CFR 835 requires that records be maintained to document certain aspects of the
external dosimetry program. These records include radiation dose records, instrument and
equipment calibration records, monitoring procedures, and area monitoring results.
10 CFR 835 also requires that certain reports be provided to individuals on their exposure
received while performing their duties. Chapter 13 provides detailed guidance on the
records necessary to document the external dosimetry program and the reports to
individuals required by 10 CFR 835. Chapter 7 of the RCS provides additional guidance.
88 DOE G 441.1-1C
5-19-08
7.0 RADIATION GENERATING DEVICES
The Radiation Generating Devices (RGDs) addressed in this chapter may be classified as
either devices that are electrically energized to produce ionizing radiation or sealed
radioactive sources that emit radiation continuously. RGDs are used at DOE sites with a
great variety of configurations and operating characteristics and in a wide spectrum of
applications. This Guide addresses RGDs used for industrial and research applications,
but does not address RGDs used for patient diagnostic or therapeutic medical
applications. Medical RGDs should be registered with the cognizant regulatory agency
which typically is a Federal, state or local level authority.
Specific examples of RGDs addressed by this Guide include: sealed photon- or
neutron-emitting radioactive sources; X-ray producing radiography equipment; research
and analytical X-ray or electron beam machines; sealed radioactive sources used as
irradiators; particle accelerators; neutron generators; Van de Graff generators;
electromagnetic pulse generators (if capable of producing ionizing radiation); electron
microscopes; electron arc welders; microwave cavities that produce X-rays incidentally,
and cabinet X-ray machines used for security applications.
Note that sealed radioactive sources are specifically addressed in Chapter 15. The
guidance provided in this Guide should be considered in addition to that provided in
Chapter 15 for those sealed radioactive sources that produce radiation fields exceeding
100 millirem (1 mSv) in one hour at a distance of 30 centimeters from the source.
7.1 Implementation Guidance
10 CFR 835 must be generic to cover the wide spectrum of facilities and activities within
the DOE complex. To ensure an adequate level of radiological safety and compliance
with 10 CFR 835, the requirements and guidance provided in the following secondary
documents should be implemented, to the extent appropriate to site-specific activities and
hazards.
Section 73
• 10 CFR 34, Licenses for Radiography and Radiation Safety Requirements for
Radiographic Operations (NRC 1992);
• ANSI N43.3, American National Standard For General Radiation Safety -
Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources,
Energies Up to 10 MeV (which updates ANSI N543-1974) (ANSI 1993);
• ANSI/HPS N43.2, Radiation Safety for X-Ray Diffraction and Fluorescence
Analysis Equipment (ANSI/HPS 2001a); and
• ANSI/HPS N43.5, Radiological Safety Standard for the Design of Radiographic
and Fluoroscopic Industrial X-Ray Equipment (Formerly called N537)
(ANSI/HPS 2005).
DOE G 441.1-1C 89
5-19-08
Should any conflict exist between the requirements and guidance provided in these
standards and the requirements of 10 CFR 835, then the requirements of 10 CFR 835 take
precedence. This Guide provides guidance that supplements that provided by the ANSI
Standards discussed above.
7.2 Administrative Organization and Controls
RGD control should be maintained by individuals responsible for RGD operations.
Overview for radiological safety should be provided by the independent radiological
control organization. Within smaller organizations, where one individual may be
responsible for multiple roles (such as RGD custodian, qualified expert, and radiological
control staff), independent oversight of that individual’s activities should be provided to
ensure the ongoing quality of the RGD program.
7.2.0 Contractor Management
To implement their responsibilities, management should perform the following:
• appoint a RGD Custodian for each RGD;
• exercise supervision to ensure safe RGD operation;
• review RGD procedures and operational and maintenance logs;
• schedule periodic inspections and monitoring;
• approve operating and emergency procedures;
• schedule and otherwise provide for training to ensure that RGD Custodians and
RGD Operators are trained and re-certified (see Chapter 14 for guidance
concerning training of personnel); and
• promptly terminate the operation of any unsafe RGD installation.
7.2.1 RGD Custodian
The appointed RGD Custodian should provide direct control over RGD installations and
operations. The RGD Custodian should ensure that the RGD installation is operated and
maintained safely and in accordance with the requirements of the site-specific RPP.
Specific responsibilities of the RGD Custodian should include the following:
• controlling the keys to RGD installations, RGDs, and/or RGD storage facilities
and authorizing the operation of the RGD installation;
• ensuring that RGD Operators follow applicable operating procedures;
• ensuring that RGD Operators follow the applicable Radiological Work Permit
(RWP), or other written authorization;
90 DOE G 441.1-1C
5-19-08
• ensuring that required dosimeters are properly worn;
• ensuring that inspections of RGD interlocks, warning lights, and other safety
features are performed and documented;
• ensuring that all required monitoring is performed and documented;
• ensuring that all RGD Operators are trained;
• reviewing and approving materials used for training RGD Operators, in
cooperation with the radiological control staff;
• ensuring that accountability records of assigned RGDs are maintained;
• notifying the radiological control staff of changes in shielding configuration, use,
storage, disposal, or loss of a RGD;
• ensuring proper disposition of unneeded RGDs;
• ensuring that sealed radioactive source integrity tests are performed; and
Section 74
• maintaining schematics (mechanical and electrical), safety device wiring
diagrams, manufacturer provided instruction manuals, and operations and
maintenance records.
7.2.2 RGD Operator
RGD Operators are those individuals authorized by the RGD Custodian to use the RGD.
The RGD Operator should:
• ensure proper control of the RGD installation and/or area;
• ensure that inspections and monitoring are performed and documented;
• ensure that required dosimeters are worn properly by all individuals in the vicinity
of RGD operations;
• follow the applicable RWP, or alternative authorization, and ensures that other
individuals also adhere to the requirements of those documents;
• establish control of all adjacent areas where individuals could receive a dose
approaching administrative limits and ensure that those areas are unoccupied
during RGD operations;
• maintain access control over the actual RGD exposure area;
DOE G 441.1-1C 91
5-19-08
• follow all applicable operating procedures; and
• promptly terminate unsafe RGD operations.
7.2.3 Qualified Expert
A qualified expert(s) should be appointed by management. To ensure technical
qualification, the qualified expert should be approved by the radiological control
manager. The qualified expert should have knowledge and training necessary to: (1)
measure ionizing radiations; (2) analyze the significance and evaluate the potential health
effects of monitoring results; and (3) advise on matters related to radiological control as it
pertains to installations covered by this Guide. The qualified expert should have in-depth
knowledge of characteristics associated with RGDs, RGD installations, and applicable
Rules, Manuals, Orders, and Standards. If the radiation generating device is capable of
producing very high acute doses, i.e., such that the hazard are to be analyzed in the
documented safety analysis, the expertise should include familiarity with any associated
safety system software and hardware used to prevent major radiological accidents.
The qualified expert should periodically review the following areas and provide
recommendations to the radiological control manager:
• the design or modification of RGD installations;
• the results of pre-operational inspections and radiological monitoring;
• the engineered safety features and administrative controls;
• the need for and adequacy of the personnel monitoring program for the
installation; and
• the training materials used for the RGD Custodians and Operators.
7.2.4 Radiological Control Manager
A radiological control manager should be designated to ensure independent overview of
radiological operations, including RGDs. The radiological control manager's function is
similar to that of the radiological protection supervisor or radiation protection officer, as
described in the specific ANSI standards referenced in this Guide and publications of the
National Council on Radiation Protection and Measurements (NCRP). Additional
guidance for radiological control manager responsibilities is provided in RCS Articles
141and 142 and ANSI N43.3.
7.2.5 Radiological Control Organization
The radiological control organization (RCO) should provide support to managers and
radiological workers. The radiological control staff should be established consistent with
Chapter 1 of the RCS.
92 DOE G 441.1-1C
5-19-08
Radiological control staff should perform the following tasks to implement their
functions described in RCS Articles 141 and 143:
Section 75
• evaluate adherence to the RPP by conducting pre-operational and periodic
inspections and radiation monitoring of RGD installations;
• under the direction of the radiological control manager, provide radiological
support to line managers and RGD operations;
• ensure that all inspections and monitoring are performed and documented;
• perform radiation monitoring of open installations to verify proper posting and
control of boundaries during operations and removal of hazards (and associated
temporary postings and barriers) after operations;
• monitor all RGD installations for potential or actual unsafe operations or
conditions and conformity to the site-specific RPP; and
• review the operational and maintenance logs maintained by RGD Custodians and
Operators to ensure that controls are commensurate with existing or potential
radiological hazards.
7.3 Development of Site-Specific Documents
10 CFR 835.104 requires that written procedures be developed and implemented as
necessary to ensure compliance with that regulation, commensurate with the radiological
hazards created by the activity and consistent with the education, training, and skills of
the individuals exposed to the hazards (10 CFR 835.104). Written procedures should be
developed and implemented as necessary to ensure proper implementation of the
radiation protection program elements addressed in this Guide. Additional guidance is
provided in Chapter 3.
7.3.0 Radiological Monitoring
Radiological monitoring should be conducted to determine and document the integrity
and adequacy of the shielding and to verify that posting and access control requirements
are satisfactory before the RGD is turned over to the RGD Custodian for routine
operation and periodically thereafter. If there is a potential for exposure in accessible
areas adjacent to the installation, then the adjacent areas should be monitored and should
be vacated when pre-operational monitoring is performed.
Specifically, the pre-operational monitoring program should be designed to:
• determine dose rate or integrated dose received in any 1 hour as dependent upon
the pulse capability of the RGD;
• evaluate the exposure potential of the RGD at the maximum value of applied
DOE G 441.1-1C 93
5-19-08
voltage or current, or at the maximum exposed position of the source for sealed
radioactive source installations. RGD(s) should be operated in steps of increasing
beam strength until the highest values are achieved;
• include the use of mechanical or electrical devices that restrict beam orientation
and magnitude, and determine the degree of beam restriction, with and without
those devices;
• detect and measure potential leaks in the shielding and barriers; and
• encompass all geometries in which the useful beam can be directed.
Special monitoring should be conducted as follows:
• during the performance of maintenance and alignment procedures if the
procedures require the presence of a primary beam;
• when any component in the system is disassembled or removed;
• any time an inspection of the components in the system reveals an abnormal
condition;
• whenever personnel monitoring dosimeters or area monitoring show a significant
increase over a previous monitoring period or are approaching administrative
limits;
• following maintenance or calibration prior to restoration to fully operable status;
and
• after any modification.
Section 76
It is not necessary to perform radiological monitoring of electrically-energized RGDs
(that is, those RGDs that do not contain radioactive material) during periods when they
have been removed from service and placed in storage. However, when any RGD which
has been in "storage" is being reactivated for use, functional and operational inspections
and radiological monitoring should be performed prior to initial use.
For open installations, where irradiation configurations and boundary conditions are
likely to change frequently, radiation monitoring shall be conducted in response to
changing working parameters [10 CFR 835.401(a)].
After the initial assessment, independent inspections and monitoring should be conducted
as necessary to verify: 1) that RGD operations continue to remain safe; 2) that during the
operation of any open installation, the proper location and posting of boundaries is
maintained; and 3) that after any modification or removal from storage of a RGD
installation, the effectiveness and operability of safety features are adequate. Additional
guidance on area monitoring is provided in Chapter 6.
94 DOE G 441.1-1C
5-19-08
7.3.1 Sealed Radioactive Source Leak Testing
A program of sealed radioactive source accountability and leak testing for radioactive
contamination and encapsulation integrity shall be implemented (10 CFR 835.1202).
Guidance for this program is provided in Chapter 15.
7.3.2 Area Posting
7.3.2.0 Radiological Conditions
Guidance for posting radiological hazards is provided in Chapter 12.
7.3.2.1 Operational Status
Posting should be used to signify the presence of an intermittent radiation condition. The
posting should also express the method used to convey that a radiation field is present.
An example of such a sign is:
"CAUTION: RADIATION BEING PRODUCED OR RADIATION
AREA EXISTS WHEN RED LIGHT IS ON"
The qualified expert should be notified of status changes and pertinent details, e.g., safety
system software errors as well as safety device malfunctioning.
7.3.2.2 Maintenance Status
Any time an installation requires maintenance, the entrance to the area in which the
installation is located and the inside of the installation should be conspicuously
posted to indicate the maintenance status of the installation. Posting should be
established:
• during the performance of maintenance and alignment procedures if the
procedures require the presence of radiation; and
• any time an inspection or monitoring reveals a deficient condition for any safety
device.
When a safety device or interlock has been approved to be by-passed or is awaiting
repair, the entrance to the installation and the RGD enclosure should be posted with a
prominent sign bearing the words "SAFETY DEVICE NOT FUNCTIONING" or a
similar message.
The qualified expert should be notified of status changes and pertinent details, e.g.,
safety system software errors as well as safety devices affected by maintenance or
malfunction.
DOE G 441.1-1C 95
5-19-08
7.3.3 Training
Guidance for radiation safety training is provided in Chapter 14 of this Guide. This
training should be augmented with pertinent material provided in DOE-HDBK-1108-97,
RADIOLOGICAL SAFETY TRAINING FOR ACCELERATOR FACILITIES (DOE
2002b) and DOE-HDBK-1109-97, RADIATION SAFETY TRAINING FOR
RADIATION-PRODUCING (X-RAY) DEVICES (DOE 1997c). Additional training
guidance is provided in Chapters 3 and 6 of the RCS.
7.3.4 Records
Section 77
Guidance for generation and maintenance of records sufficient to meet the requirements
of 10 CFR 835 are provided in Chapter 13.
7.4 Engineered Safety Controls
10 CFR 835.1001 requires that measures be taken to maintain radiation exposures in
controlled areas ALARA. The primary method used shall be engineered controls (e.g.,
confinement, ventilation, remote handling, and shielding); administrative controls shall
be incorporated only as supplemental methods and for specific activities where
engineered controls are demonstrated to be impractical (10 CFR 835.1001).
10 CFR 835.1003 further requires that during routine operations, the combination of
engineered controls and administrative controls shall provide that the anticipated
occupational dose to general employees does not exceed regulatory limits and that the
ALARA process is utilized for personnel exposures to ionizing radiation. Safety system
hardware and software are sometimes associated with engineered safety features, i.e., for
hazards that must be analyzed in a documented safety analysis.
Engineered controls typically include features that are used to control the work
environment, such as permanent structures, systems, and controls, including shielding,
filtered ventilation systems, remote controls, containment devices, and the use of designs
and materials that facilitate operations, maintenance, and other activities. Temporary
engineered controls (e.g., temporary shielding, confinement and ventilation systems) are
typically used to facilitate short-term or emergent operations when the installed
engineered controls do not provide the desired level of protection. Administrative
controls typically include controls that are implemented by the individual at the work site,
including written procedures, technical work documents, work authorizations, and other
controls that are used to guide individual actions in a manner that will facilitate
implementation of the ALARA process (10 CFR 835.1001).
ANSI N43.3 and N43.2 provide specific guidance that should be considered for exempt
shielded (including cabinet X-ray), shielded, unattended, and open installations. As
discussed in the introduction to Chapter 7, not all of the ANSI guidance for shielded,
unattended, and open installations meets the requirements of 10 CFR 835. If the design of
the facility cannot be upgraded in a practical manner to meet the 10 CFR 835 exposure
rate criteria, then the alternative is the implementation of additional access and
occupancy controls to meet the design objectives.
96 DOE G 441.1-1C
5-19-08
7.4.0 Shielding, Controls, & Safety Devices
7.4.0.0 Shielding
Permanent shielding should be designed and installed consistent with the guidance
provided in ANSI N43.3.
The effect of temporary shielding should be evaluated prior to its installation. The
installation, use, and removal of temporary shielding should be controlled by procedures
and in accordance with RCS 314.
7.4.0.1 Access Control and Safety Devices
10 CFR 835.501 establishes requirements for maintaining control over entries into
radiological areas. 10 CFR 835.502 establishes supplemental requirements for entry
controls for high and very high radiation areas. Viewed collectively, these provisions
establish a hierarchy of controls, with general, flexible requirements for all radiological
areas and more specific and stringent requirements for areas of greater hazard.
Section 78
Guidance for establishing appropriate signs and barricades as required by
10 CFR 835.501 is provided in this Guide. Guidance for establishing appropriate
administrative controls is provided in Chapters 4 and 11. The RCS provides additional
guidance for all these. The remainder of this chapter provides guidance for implementing
the physical controls required by 10 CFR 835.501 and 502.
The purpose of access control devices is to prevent unauthorized or inadvertent entry into
a radiological area and/or to warn of a hazard.
If locked entryways are used, the keys used for one RGD installation or storage facility
should not provide access to another RGD installation or storage facility.
Additional measures shall be implemented to ensure individuals are not able to gain
unauthorized or inadvertent access to very high radiation areas [10 CFR 835.502(c)].
Such measures (i.e., physical constraints) should include locking or securing service
doors and panels with tamper resistant fasteners or the use of multiple and redundant
access controls.
Due to the lack of intrinsic shielding and the nature of use, access to a very high radiation
area could be possible for an "open" installation. Additional measures (e.g., interlocked
"photoelectric eye" light beams) should be established to meet this requirement.
There are many situations where, when the access points of a radioactive material
container are closed, there are no physically controlled high radiation areas exterior to the
container. In some of these situations, opening on access point creates a physically
controlled high radiation area exterior to the container. An acceptable approach for these
situations is to implement one or more of the features of 10 CFR 835.502 for the
container. This approach would be consistent with the requirements of 10 CFR 835.502
in acting to prevent uncontrolled or unplanned exposures to individuals.
DOE G 441.1-1C 97
5-19-08
In addition, in situations where an individual could enter a container and access a
physically controlled high radiation area, one or more of the features of
10 CFR 835.502 should also be implemented for the container. In this case, the walls
of the container form the boundary of an accessible physically controlled high
radiation area.
The 10 CFR 835.502 features discussed above could include either controlling access
to the container itself or controlling access to the room where the container is
residing.
Generally, entryways that are secured closed in such a manner that a tool, such as a hoist,
must be used to gain access, may be considered locked. However, if the opening tool was
left in place such that an individual would not need to make a determined effort to gain
access the entry, in this situation, would not be considered adequately locked or
otherwise secured. Similar unacceptable examples would include leaving a ladder
secured adjacent to a fence meant to restrict access or securing an entryway with a single
bolt and leaving the wrench attached to the bolt. These examples are analogous to the
unacceptable situation of locking an entryway with a key lock and leaving the key in the
lock. These examples are not considered consistent with 10 CFR 835.501(b), which
requires that the degree of control be commensurate with existing and potential
radiological hazards within the area.
Section 79
While the purpose of locking these areas is to maintain a high level of positive access
control, it is recognized that these controls cannot absolutely prevent determined
circumvention of the physical barrier such as with the use of wire cutters or unbolting the
hinges to a doorway. Instances of such determined circumvention should be addressed
with appropriate disciplinary action.
In addition to the above mentioned controls, the entryways or access point to the
container would also need to be labeled, per 10 CFR 835.601, if adequate warning is not
provided by control measures and required posting. The label should specify that the
entryways should not be opened without radiological control approval and that significant
levels of radiation may exist. In the above referenced situation, neither container labeling
nor other posting was implemented to warn individuals not to open the container.
Also, all individuals in the controlled area need to be trained, in accordance with 10 CFR
835.901 (a), in radiation safety prior to receiving occupational exposure during access to
controlled areas at a DOE site or facility. This training would need to address the
importance of following posting and labeling directions as well as the site specific
information and policy concerning the use of tools to open entryways.
7.4.0.2 Interlocks
Doors and/or access panels in exempt shielded, shielded, and unattended installations
should be equipped with one or more fail-safe safety interlocks to prevent irradiation of
an individual [ANSI N43.3(6.5.2)].
98 DOE G 441.1-1C
5-19-08
If an area radiation monitor is incorporated into a safety interlock system, the circuitry
should be such that a failure of the monitor shall either prevent normal access into the
area or operation of the RGD.
7.4.0.3 Device Controls
One or more physical control devices should be used to secure the RGD to prevent
unauthorized access and use. The control system governing the production of radiation
should be equipped with a lock and key to prevent unauthorized use. The key
controlling the production of radiation in one RGD should not control the production in
another.
Control devices used to limit RGD time, position (irradiation geometry), current,
voltage, beam intensity, or control panel lights or system indicators should be fail-safe.
7.4.0.4 Run-Safe and Emergency Shutdown Devices
Administrative procedures should be implemented to ensure that the RGD installation
and the RGD safety interlock control devices are such that:
• radiation cannot be produced until the interlock system logic has been
completely satisfied;
• production of radiation cannot be resumed by merely reestablishing the
interlock circuit at the location where an interlock was tripped; and
• the safety circuit cannot be re-energized or reestablished automatically (i.e.,
there should be a manual safety circuit reset on or near the main control
console).
For each area designated as a high radiation area or very high radiation area,
10 CFR 835.502 provides an option that permits a control device to automatically
generate audible or visible alarm signals to alert individuals and the cognizant RGD
Operator of a potential entry into the area before it occurs. In order to meet ANSI
N43.3 guidance, warning devices should be provided as an addition to any other access
control feature in accordance with the installation specific requirements delineated in
Section 7.4.1 of this Guide. These warning devices are typically warning lights.
Section 80
All RGD warning lights should be red or magenta for consistency. A sufficient number
of lights should be installed so that at least one light is easily visible from all reasonably
occupied areas that may have dangerous radiation levels and from reasonable avenues
of approach to such areas.
However, warning lights (even though interlocked to fail-safe if burnt out) are only
passive in nature. When operating, they generally do not prevent an individual from
physical access to a radiation beam unless they are used as part of a photosensitive
DOE G 441.1-1C 99
5-19-08
circuit. Such a circuit would remove the radiation beam or field if any individual
intercepted the light beam.
Due to the passiveness (i.e., reliance on worker attention and action) of this safety feature
and the potential for failure, at least one interlocked warning light should be used in all
circumstances. The interlocked warning light should be used to provide visual indication
that radiation is being produced, and should be used in conjunction with any interlocked
safety device which restricts physical access to a radiation beam or field. This is
recommended above and beyond the installation specific requirements in this Guide, or
the minimum required by 10 CFR 835.502. When used in this fashion, the RGD should
not be operable when the warning light is out.
It should not be possible to override the operation of any warning device activated by a
fail-safe function without positive actions by the operator such as resetting controls at the
control console. Where feasible, i.e., for new or significantly modified RGDs that are
capable of producing very high acute doses, i.e., that must be analyzed in the documented
safety analysis, safety system hardware and software should provide additional safety via
computer-assisted operations as well as indicate all abnormal events at the console and
remotely notify cognizant personnel of abnormal events and conditions.
7.4.0.5 Monitoring Instruments
Requirements and guidance for instruments used to measure radiation are given in
10 CFR 835.401(b) and Chapter 9 of this Guide.
7.4.1 Guidance for Specific RGD Installations
In addition to the general guidance in this Guide, there is specific guidance cited from
ANSI N43.3 and N43.2 for each of the primary RGD installations and the open and
shielded beam analytical RGDs. The analytical RGD installations may enclose one or
more X-ray devices and/or sealed radioactive sources.
The ANSI standards specify dose rates that are to be used for installation categorization
only and are not to be interpreted as permissible levels.
7.4.1.0 Accelerators
Small (low voltage, less than or equal to 10 MeV) accelerators used for radiography, ion
implantation, or the production of incidental photons or particles (e.g., neutron
generators) in exempt shielded, shielded, or open installations should be operated in
accordance with the guidance specified by this Guide and the applicable ANSI standards.
When accelerators are used outside of exempt shielded or shielded installations,
requirements for open-air radiography prevail.
When used within shielded installations, determination must be made whether the
requirements for the exempt shielded or shielded installations prevail. Although the basic
radiological control program requirements discussed in this Guide are generally
100 DOE G 441.1-1C
5-19-08
Section 81
applicable to the large multi-purpose research accelerators, the complexities associated
with these facilities may require additional consideration beyond the scope of this Guide.
Additional requirements for those RGDs with particle energies exceeding 10 MeV are
provided in DOE O 420.2B, Safety of Accelerator Facilities.
7.4.1.1 Electron Devices that Generate X-Rays Incidentally
These devices are usually shielded to attenuate the emission of X-rays. Requirements for
the exempt shielded or shielded installations prevail. Examples include electron beam
welders, electron microscopes, pulse generators, etc., and microwave cavities if used as
beam guides.
Preoperational inspections and monitoring should be performed initially upon receipt.
However, the requirement for the routine semiannual inspections and monitoring may be
modified at the discretion of the radiological control manager.
7.4.1.2 Cabinet X-Ray Systems
Since these RGDs are used primarily in security applications and are commercially
available, manufacturer requirements for these RGDs are delineated in 21 CFR Part
1020.40.
These RGDs should be procured, categorized, inventoried, operated, inspected and
monitored, and decommissioned in accordance with this Guide to ensure compliance with
10 CFR 835.1001& 1003). Inspections and surveys should be performed as specified in
Section 7.4.1.1, of this Guide.
If not commercially obtained, the requirements for an exempt shielded installation
prevail.
DOE G 441.1-1C 101
5-19-08
8.0 EVALUATION AND CONTROL OF RADIATION DOSE TO THE
EMBRYO/FETUS
DOE has codified in 10 CFR 835.206 radiation dose limits for the embryo/fetus as a
result of the occupational exposure of a declared pregnant worker. These requirements
are established to provide protection to the embryo/fetus in a manner that does not
discriminate against the rights of the pregnant worker.
Programs established to evaluate and control radiation dose to the embryo/fetus need to
balance protection of the embryo/fetus (from hazards that may arise from the mother's
occupational radiation exposure) against the possibility of work discrimination against
the mother. The choice of providing additional protection to the embryo/fetus is left
entirely to the voluntary discretion of the mother. The Supreme Court ruled in United
Automobile Workers v. Johnson Controls, Inc., 499 U.S.187, 206 (USLW 1991) that
". . . decisions about the welfare of future children must be left to the parents who
conceive, bear, support, and raise them rather than to the employers who hire those
parents."
8.1 Implementation Guidance
Essential elements of an acceptable program to evaluate and control radiation dose to the
embryo/fetus include:
• voluntary, formal declaration of pregnancy, including the estimated date of
conception;
• voluntary, formal withdrawal of declaration of pregnancy;
• work restrictions for workers who have voluntarily declared their pregnancies;
• counseling of workers;
• dose calculation and monitoring methods;
• worker training;
• record-keeping; and
• reporting.
Acceptable methods for implementing these program elements are discussed in this
chapter.
8.2 Declaration of Pregnancy/Withdrawal of Declaration
Due to the higher sensitivity of the embryo/fetus to ionizing radiation (relative to the
sensitivity of adults), 10 CFR 835 establishes provisions for individuals to voluntarily
102 DOE G 441.1-1C
5-19-08
Section 82
declare their pregnancy and to accept restrictions on the equivalent dose to the
embryo/fetus (i.e., 0.5 rem (0.005 Sv) gestation period equivalent dose limit, uniform
exposure rate) (10 CFR 835.206). It remains the sole and fundamental responsibility of
the worker to decide whether to formally declare her pregnancy and consequently
become subject to the above dose limits and restrictions. It is the employers'
responsibility to ensure that the worker is fully informed and provided with counseling to
assist in her decision making. Deciding whether or not to accept the risk from radiation
dose to the embryo/fetus is entirely the responsibility of the pregnant worker.
A pregnancy may be declared by the pregnant worker or the worker who is planning a
pregnancy, and shall be formally declared in writing [10 CFR 835.2(a)]. The declaration
shall include the estimated date of conception [10 CFR 835.704(d)], and should be
declared as early in the pregnancy as possible. A declared pregnant worker that is
planning a pregnancy should notify her supervisor as soon as possible following
verification of conception. The statement should be signed by the employee and delivered
to her supervisor or to a designated contact in health physics, laboratory safety,
occupational health, or medical services. A sample declaration form is provided in
Appendix 8.A of this Guide.
10 CFR 835 also allows an individual who has declared her pregnancy to withdraw her
declaration and to return to the general employee occupational dose limit (5 rem (0.05
Sv) total effective dose in a year). The employer is considered to be notified of the
withdrawal of the declaration of pregnancy at the time that the individual submits a
signed and dated statement to her supervisor or to the designated contact, indicating that
she is withdrawing her formal declaration of pregnancy. A sample form is provided in
Appendix 8.B of this Guide. No additional explanation or justification should be
requested by the employer. The worker shall be allowed to withdraw her declaration of
pregnancy at any time [10 CFR 835.2(a), Declared pregnant worker], thus terminating
any work restrictions. Once such notification has been made, it is the employer's
responsibility to remove any imposed work or area restrictions as discussed in
Section 8.3.
The rights (e.g., right to work) and privacy of the worker should be maintained before,
during, and following any declaration of pregnancy. All aspects of the worker's
withdrawal of the declaration of pregnancy should also be maintained confidential. The
rights and privacy of workers who have chosen not to declare their pregnancy should also
be respected. Because 10 CFR 835.901 requires that radiation safety training include
discussions of the risks of exposure to radiation and radioactive materials during
pregnancy, and include an individual's rights and responsibilities as related to the
facility's radiation protection program, there is no need to remind an undeclared pregnant
worker of the opportunity for a pregnant employee to avail herself of the special limits
for protection of the embryo/fetus. Such reminders would be inappropriate in light of the
United Auto Workers v. Johnson Controls, Inc. case previously cited. Chapter 14
provides guidance on initial and biennial training, as well as recommendations for annual
refresher training.
DOE G 441.1-1C 103
5-19-08
8.3 Work Restrictions Following Declarations of Pregnancy
Section 83
Following the submittal of a declaration of pregnancy, the radiation equivalent dose
received by the embryo/fetus prior to the declaration (i.e., from the estimated date of
conception to the date of declaration) should be calculated as soon as practicable. Section
8.5 of this Guide provides an acceptable methodology. Once this equivalent dose has
been calculated, the dose equivalent allowed for the remaining gestation period should be
determined. An evaluation of the equivalent dose that the embryo/fetus is likely to
receive while the declared pregnant worker is performing her current job duties should be
performed to determine if work restrictions are necessary. The evaluation should take
into consideration the 0.5 rem equivalent dose limit, the equivalent dose remaining for
the gestation period, and the requirement not to vary substantially above a uniform
exposure rate that would satisfy the 0.5 rem limit during the gestation period. If the
nature of the declared pregnant worker’s duties make it likely that either the 0.5 rem limit
will be exceeded or that substantial variation will occur, then work restrictions shall be
established [10 CFR 835.206(a) and (b)]. If it is determined that the equivalent dose to
the embryo/fetus has already exceeded 0.5 rem, the declared pregnant worker shall not be
assigned to tasks where additional occupational exposure is likely during the remainder
of the gestation period [10 CFR 835.206(c)], unless she voluntarily revokes her
pregnancy declaration.
A uniform exposure rate in rem/week may be calculated by subtracting the equivalent
dose received by the embryo/fetus prior to the declaration of the pregnancy from the 0.5
rem limit and then dividing this difference by the approximate number of weeks
remaining in the gestation period. For example, for a pregnancy that was declared at 10
weeks into the gestation period with a calculated equivalent dose of 200 mrem to the
embryo/fetus prior to the declaration of the pregnancy, a uniform exposure rate for the
remainder of the pregnancy would be (500 mrem-200 mrem)/30 week or approximately
10 mrem/week. 10 CFR 835 allows flexibility for a facility specific determination of
what constitutes a “substantial variation.” The value selected will vary depending
onsite-specific factors such as nature of work performed, radiological conditions in the
areas to be entered, and the sensitivity and accuracy of the individual monitoring methods
used. DOE recommends a value equal to the calculated uniform equivalent dose rate per
week +100%. In the example cited above, this would be any dose rate greater than 20
mrem/week. Each facility should determine and document the methods used to identify a
“substantial variation.”
Additional work or area restrictions for the declared pregnant worker, based on
limiting the total dose (internal and external) may be established as necessary to
ensure compliance with the total equivalent dose and “substantial variation” criteria.
Procedures should provide for coordination between radiation protection and line
management, occupational health or medical services. Examples of typical
restrictions include reducing the time allowed in radiological areas (including
prohibiting access to certain areas), restricting the time spent in certain areas within a
radiological area, restricting performance of certain tasks, and requiring use of
104 DOE G 441.1-1C
5-19-08
Section 84
supplemental controls, such as shielding, ventilation, and personal protective
equipment. To determine whether restrictions should apply, each facility should
evaluate the worker's dose history and radiological conditions in those areas to which
the declared pregnant worker may have access. Also, employers should provide
declared pregnant workers the option of a mutually agreeable work assignment that
does not involve additional occupational dose. The training for workers should
identify such restrictions and options (see Chapter 14).
Due to difficulties in evaluating fetal dose resulting from radioactive material intakes,
restrictions should be imposed to minimize a declared pregnant worker’s radioactive
material intakes. Consideration should be given to restricting declared pregnant workers
from entering areas where they may receive an intake of radionuclides. ALARA (total
dose) aspects should also be considered in implementing these restrictions. If it is not
practical to restrict the declared pregnant worker from entry into areas where intakes are
likely to occur, enhanced use of engineered controls (primary) and administrative
controls (secondary) should be considered.
Any additional workplace restrictions for the declared pregnant worker shall
(10 CFR 835.206) remain in place until the baby is born, the declaration of pregnancy has
been withdrawn (see the sample declaration and withdrawal forms in Appendices 8.A and
8.B), or it is determined that such restrictions are not required to ensure compliance with
10 CFR 835.206.
Radiological work restrictions apply only to declared pregnant workers. If the worker
does not declare her pregnancy, she cannot be restricted in her work or in the dose that
she receives unless these restrictions apply to all employees of similar position, i.e.
general employees or radiological workers as specified in 10 CFR 835.
8.4 Counseling
An employee with expertise in health physics, laboratory safety, occupational health, or
medical services should be designated as a contact for female workers to obtain
counseling or additional information on the subject of the risks to the embryo/fetus from
exposure to ionizing radiation. Individuals who provide this counseling should receive
training in risk communication and be knowledgeable of the risks of fetal radiation
exposure. NRC Regulatory Guide 8.13, Instruction Concerning Prenatal Radiation
Exposure (NRC 1987) and NCRP Report No. 116, Limitation of Exposure to Ionizing
Radiation (NCRP 1993) provides information on the risks of radiation dose to the
embryo/fetus.
Counseling of any worker on the risks of exposure to radiation to the embryo/fetus should
be documented regardless of the worker's decision to declare or not to declare the
pregnancy.
DOE G 441.1-1C 105
5-19-08
8.5 Dose Determination and Monitoring Methods
8.5.0 Dose Determination
The equivalent dose to the embryo/fetus should be determined as soon as practicable
after a worker submits a declaration of pregnancy, at sufficient intervals after
declaration to ensure the limit is not exceeded and that substantial variations do not
occur, and at the end of the gestation period. It may be necessary to include the dose for
the entire reporting period during which conception occurred, unless more detailed
records are available to determine the fraction of the dose received since the time of
conception. If enough information is available to assume that the previous dose was
received in a linear fashion, the fraction of the dose may be used that corresponds to the
fraction of the reporting period during which the worker was pregnant. This method is
appropriate for the majority of workers who work on a variety of tasks during a
reporting period, none of which results in a significant dose. At the conclusion of a
declared pregnancy the dose received by the embryo/fetus prior to the declaration of
pregnancy plus the dose received during the remainder of the pregnancy should be
calculated as the sum of:
Section 85
• the equivalent dose to the embryo/fetus from external sources of radiation;
• the equivalent dose to the embryo/fetus from intakes of radionuclides in the
embryo/fetus; and
• the equivalent dose to the embryo/fetus resulting from intakes of radionuclides
in the declared pregnant worker.
A sample dose record form is provided in Appendix 8.C. Detailed equivalent dose
calculations should be attached to the record form. The dose to the embryo/fetus from
radiation external to the mother should be taken as the equivalent dose to the whole
body to the mother's abdomen or torso. For external dose, the equivalent dose to the
whole body is assessed at a depth of 1 cm in tissue.
If an intake of radioactive material occurs, or occurred between conception and the
declaration of pregnancy, the equivalent dose to the embryo/fetus should be determined
as follows. The equivalent dose to the embryo/fetus from radionuclides in the
embryo/fetus and in the mother that are relatively uniformly distributed, such as Cs-137
and compounds of H-3 and C-14 that are not organically bound, may be considered to
be the same as the equivalent dose to the mother because, under these circumstances,
the same energy would be deposited per gram of tissue in both the mother and the fetus.
Refer to ICRP Publication 88, Doses to the Embryo and Fetus from Intakes of
Radionuclides by the Mother, (ICRP 1998) for methodologies for estimating dose to the
embryo/fetus. If other methods are used, the basis for their use in demonstrating an
equivalent or better level of protection should be documented.
106 DOE G 441.1-1C
5-19-08
8.5.1 Monitoring Methods
Guidance on internal and external dose monitoring methods is provided in Chapters 5 and
6 of this Guide.
8.6 Training
It is important that all individuals who enter a controlled area understand the risk to the
embryo/fetus from ionizing radiation received as a result of the mother’s occupational
exposure. It is also important that procedures regarding fetal exposure be well understood
by workers and their supervisors.
Note that the radiation safety training requirements in 10 CFR 835.901(which include the
risk of prenatal exposure to ionizing radiation) pertain to workers who are allowed
unescorted access to, and/or receive occupational radiation dose in, controlled areas.
Under certain conditions, it is possible that a pregnant worker outside of the controlled
area could receive a dose exceeding the 50 millirem (0.5 mSv) monitoring threshold, but
not be subject to the 10 CFR 835.901 training requirements. If such conditions exist,
measures should be implemented to ensure that affected workers are aware of the risks of
fetal radiation exposure and their rights to declare their pregnancy. This information
should be disseminated through radiation safety training or equivalent measures.
Additional guidance on radiation safety training programs can be found in Chapter 14 of
this Guide and NRC Regulatory Guide 8.13.
8.7 Record -Keeping and Reporting
Record-keeping and reporting guidance may be found in Chapter 13.
DOE G 441.1-1C 107 (and 108)
5-19-08
Appendix 8.A
Declaration of Pregnancy Form
DECLARATION OF PREGNANCY
Section 86
In accordance with Section 206 of 10 CFR 835, I am voluntarily declaring that I am pregnant, for
the purposes of lowering the dose received by my embryo/fetus. I realize that work restrictions
may be imposed to ensure that the embryo/fetus does not receive a dose in excess of that given in
10 CFR 835 (500 mrem, or 0.005 Sv, during the entire gestation period). I also realize that
supplemental dosimetry may be supplied to me, along with periodic reports of the dose received
by my embryo/fetus.
Estimated Date of Conception ____________________________
____________________________________________________
Printed name of worker ID#
____________________________________________________
Signature of worker Date
____________________________________________________
Printed name of supervisor Title
____________________________________________________
Signature of supervisor Date
____________________________________________________
Printed name of Health Physics Title
or Medical Representative
DOE G 441.1-1C 109
5-19-08
Appendix 8.B
Withdrawal of Pregnancy Declaration Form
WITHDRAWAL OF PREGNANCY DECLARATION
I am withdrawing my previous declaration of pregnancy. I understand that, as a result of
signing and submitting this form, any work restrictions that have been imposed as a result of
the previously submitted "Declaration of Pregnancy" will be lifted.
Date of Pregnancy Declaration ___________________________
____________________________________________________
Printed name of worker ID#
____________________________________________________
Signature of worker Date
____________________________________________________
Printed name of supervisor Title
____________________________________________________
Signature of supervisor Date
____________________________________________________
Printed name of Health Physics Title
or Medical Representative
____________________________________________________
Printed name of Health Physics Title
or Medical Representative
____________________________________________________
Signature of Health Physics Date
or Medical Representative
110 DOE G 441.1-1C
5-19-08
Appendix 8.C
Embryo/Fetal Equivalent Dose Record Form
EMBRYO/FETAL EQUIVALENT DOSE RECORD
_______________________________________________________________
Printed name of worker ID#
Date of Declaration of Pregnancy _______________________
Estimated Date of Conception _______________________
Estimated External Dose _______________________
(prior to declaration of pregnancy)
External Dose for remaining _______________________
period of pregnancy
Estimated Internal Dose _______________________
(prior to declaration of pregnancy)
From radionuclides in the _______________________
embryo/fetus
From radionuclides in the mother _______________________
Subtotal _______________________
Internal Dose for remaining _______________________
period of pregnancy
From radionuclides in the _______________________
embryo/fetus
From radionuclides in the mother _______________________
Subtotal _______________________
Total Dose during gestation period _______________________
______________________________________________________________
Printed name of Evaluator Title
______________________________________________________________
Signature of Evaluator Date
DOE G 441.1-1C 111
5-19-08
9.0 PORTABLE MONITORING INSTRUMENT CALIBRATION
A comprehensive radiation protection program (RPP) requires reliable means of
monitoring radiological conditions. Such monitoring requires the use of properly
functioning radiation monitoring instruments.
Section 87
10 CFR 835.401(b) requires that instruments and equipment used for monitoring
radiological conditions shall be appropriate for the radiation(s) encountered and the
environmental conditions and be routinely maintained, calibrated, and tested. American
National Standards Institute (ANSI) Standard N323A, Radiation Protection
Instrumentation Test and Calibration, Portable Survey Instruments (ANSI 1997a)
provides comprehensive guidance for implementing a portable monitoring instrument
calibration program.
This Guide provides guidance for a portable monitoring instrument calibration program
that addresses selection (acceptance testing), calibration, tests for operability (functional
tests and performance tests), maintenance, calibration equipment, calibration quality,
laboratory documentation, facilities, and staff. Note that, while 10 CFR 835.401(b)
applies to all radiation monitoring instruments and equipment, the guidance provided in
this Guide applies specifically to portable monitoring instruments only. This Guide does
not provide specific guidance for:
• installed or stationary monitors such as air monitors, portal monitors, and other
non-portable monitoring instrumentation;
• laboratory equipment such as liquid scintillation counters and complex laboratory
multi-channel analyzers;
• low exposure rate instruments (even if they are portable) with ranges extending
below 0.1mrad/h;
• personal monitoring devices, such as thermoluminescent dosimeters and
radio-sensitive film. These devices are addressed by DOE-STD-1111-98,
DEPARTMENT OF ENERGY LABORATORY ACCREDITATION
PROGRAM ADMINISTRATION (DOE 1998a);
• pocket ionization chambers. These devices are addressed by ANSI N13.5,
Performance Specifications for Direct Reading and Indirect Reading Pocket
Dosimeters (ANSI 1989a) and ANSI N322, American National Standard
Inspection, Test, Construction, and Performance Requirements for Direct
Reading Electrostatic/Electroscope Type Dosimeters (ANSI 1997b); and
• electronic dosimeters. Appropriate guidance regarding selection, calibration,
testing and maintenance of electronic dosimeters is provided in ANSI N13.27,
112 DOE G 441.1-1C
5-19-08
Performance Specifications for Pocket-sized Alarming Dosimeter/Ratemeters
(ANSI 1992a).
While this Guide does not apply directly to the above listed devices, many of the
concepts and practices discussed in this Guide, and in the referenced consensus standards,
may be applicable to these devices. These concepts and practices should be considered
when establishing calibration and maintenance programs for these devices.
9.1 Implementation Guidance
This chapter provides guidance for selecting, calibrating, testing, and maintaining
portable radiation monitoring instruments and equipment. The portable monitoring
instrument maintenance and calibration program should be developed and conducted
consistent with ANSI N323A.
The essential elements of an acceptable portable instrument calibration program are
shown below with reference to 10 CFR 835, with additional elements provided in ANSI
N323A:
• a system that ensures calibration shall be performed periodically on each
instrument [10 CFR 835.401(b)(1)]. ANSI N323A (4.9) recommends that
calibration be performed at least annually;
• an internal audit program shall be conducted no less frequently than every
36 months (10 CFR 835.102); and
Section 88
• a records program shall be established that documents results of maintenance and
calibration performed on instruments and equipment used for area monitoring and
contamination control [10 CFR 835.703(d)], includes the maintenance of training
records [10 CFR 835.704(a)], documents changes in equipment, techniques, and
procedures used for monitoring, [10 CFR 835.704(e)], and documents the results
of internal audits [10 CFR 835.704(c)].
Further, the following elements should be in place for those activities that perform their
own instrument calibrations:
• procedures addressing the calibration of reference sources, support instruments,
and field instruments;
• a method to determine when instruments have been returned out-of-calibration
and a method to notify users of out-of-calibration instruments;
• adequate technical staff with appropriate training in instrument calibration; and
• a dedicated facility that permits calibrations without outside physical interference.
DOE G 441.1-1C 113
5-19-08
For those activities that rely on contracted organizations to perform calibration services,
the RPP should include or make reference to a Memorandum of Agreement with the
calibration contractor(s) that assures compliance with applicable DOE requirements.
9.2 Instrument Selection
Instruments shall be selected that are appropriate to measure the type(s), levels, and
energies of radiation(s) encountered and for the existing environmental conditions
[10 CFR 835.401(b)(2) and (b)(3)]. To ensure these requirements are met, the initial
instrument selection process should include knowledge of facility radiation types,
energies, anticipated or known ranges, and results of available instrument performance
and testing data (vendor or independent). The selection process should include type
testing and acceptance testing.
9.2.0 Type Testing
DOE encourages implementation of a formal instrument qualification (type testing)
process in accordance with the relevant portions of ANSI N323A, ANSI N42.17A,
Performance Specifications for Health Physics Instrumentation - Portable Instruments
for Use In Normal Environmental Conditions (ANSI 1989b), and ANSI N42.17C,
Performance Specifications for Health Physics Instrumentation - Portable Instruments
for Use In Extreme Environmental Conditions (ANSI 1989c).
The Department recognizes that hundreds of different types of instruments are used
throughout the complex, including both commercially available and unique instruments.
Some individual sites have well over one hundred different instruments in use. Testing of
these instruments at each DOE site to the standards established in ANSI N42.17A would
not be cost effective. While testing of instrument types in accordance with ANSI
N42.17A is encouraged, such testing is not required.
9.2.1 Acceptance Testing
Prior to use, new instruments should be subjected to acceptance testing as detailed in
ANSI N323A. Instruments that do not meet the selected specifications should not be
accepted or used by the facility. ANSI N320, American National Standard Performance
Specifications for Reactor Emergency Radiological Monitoring Instrumentation, (ANSI
1979) provides performance parameters for various types of instruments for monitoring
releases of radionuclides associated with an accident at a reactor facility.
9.3 Instrument Calibration
Section 89
ANSI N323A sets forth criteria for proper portable monitoring instrument calibration. An
instrument calibration shall be performed on each instrument periodically at an
established frequency [10 CFR835.401(b)(1)]. ANSI N323A establishes an annual
calibration frequency for portable monitoring instruments. The calibration frequency
should be determined and the calibration should be performed according to the details
114 DOE G 441.1-1C
5-19-08
presented in the above referenced consensus standards. If routine checks (e.g., routine
operability tests and as-found tests) indicate that the response of an instrument (or type of
instrument) remains stable over a long period of time, then the calibration frequency may
be extended. Conversely, if routine checks indicate that an instrument (or type of
instrument) fails to provide a stable response over the prescribed calibration interval, then
the calibration interval should be shortened. The reliability of an instrument (or type of
instrument) and appropriate calibration frequency should be determined by collecting and
analyzing data in accordance with National Conference of Standards Laboratories
Recommended Practice RP-1, Establishment and Adjustment of Calibration Intervals
(NCSL 1996).
Sites may find it advantageous for certain applications to continue calibrating portable
neutron survey instruments using the existing neutron quality factors. For example,
neutron calibrations using existing neutron quality factors may correlate better with
surveys conducted to meet Department of Transportation requirements. If this approach is
taken, as previously mentioned, a scaling factor or a comparable approach may be
applied to portable neutron survey instrument results and used for controlling and
limiting individual neutron exposures.
9.4 Operability Tests
Functional tests should be performed prior to initial use of an instrument in the field.
Functional tests should be detailed in the instrument-use procedures and should include,
as a minimum: general condition; battery condition; verification of current calibration
(i.e., check to see that the date due for calibration has not passed); background readings;
and other tests (high voltage, zero setting, alarm functions, etc.) as applicable to the
instrument. Functional tests should also include a source response check (i.e., observing
the instrument response to a check source) before initial operation. During use in the
field, instruments should be tested with a check source to ensure that the readings remain
within prescribed limits. This should be done as prescribed in ANSI N323A. The
performance of functional tests during use in the field should be appropriately
documented. This may be as simple as a check-list on the survey sheet.
Performance tests should be performed periodically and after maintenance to ensure that
the instruments continue to meet performance requirements for field measurements.
Examples of performance tests are tests for geotropism and response time. Performance
requirements should be met as specified in the applicable sections of ANSI N323A,
ANSI N42.17A, and ANSI N42.17 C. These tests may be conducted as part of the
calibration procedure.
9.5 Maintenance
Maintenance shall be performed periodically on an established frequency
[10 CFR 835.401(b)(1)]. Maintenance activities should be directed toward ensuring that
the instruments continue to meet the required accuracy for field measurements.
DOE G 441.1-1C 115
5-19-08
Section 90
All preventive and corrective maintenance should be performed using components and
procedural recommendations at least as stringent as those specified by the instrument
manufacturer. If the manufacturer does not provide routine maintenance procedures, a
procedure should be written and approved by staff and management in the organization
performing the maintenance.
9.6 Calibration Equipment/Calibration Quality
The calibration laboratory should possess and maintain appropriate radiation and
non-radiation standards to achieve reliable operation.
Instruments should be calibrated with appropriate standards that are traceable to the
National Institute of Standards and Technology (NIST) or its international equivalents.
Calibrations of reference radiation fields or sources, calibration assemblies, maintenance
of standards, and check sources should be in accordance with ANSI N323A. For
information on acceptable reference sources for calibration for various radiation types,
refer to Table 2 of ANSI N323A. Instruments should be calibrated using a source of
appropriate energy for the radionuclides anticipated to be encountered. Calibration
quality including calibration field accuracies and quantities should be in accordance with
ANSI N323A.
For non-radiation quantities (e.g., temperature, humidity, pressure, voltage, current, etc.),
the facility may use standards based on traceability to NIST.
9.7 Laboratory Documentation
The calibration laboratory should maintain the following sets of documentation: (1) the
laboratory protocol; (2) the laboratory records; and (3) the calibration records. Historical
records should be maintained to detail any changes or revisions in procedures or
protocols. The laboratory protocol describes the laboratory operations, i.e., what the
laboratory is expected to do and how it is expected to do it. This documentation should
also include the detailed calibration procedures for each instrument routinely calibrated.
The laboratory records, on the other hand, are those records that document the activities
of the laboratory. Finally, the calibration records are those records that document the
maintenance, calibration, and testing of each instrument and source used.
9.7.0 Laboratory Protocol
Each DOE laboratory should have a written protocol for operations. Components that
should be included in the protocol are listed in ANSI/NCSL Z540-1-1994, American
National Standard for Calibration - Calibration Laboratories and Measuring and Test
Equipment - General Requirements (ANSI/NCSL 1994). Radiation detection instruments
that are commonly used to perform area and individual monitoring required by 10 CFR
835 need not be considered to be measuring and test equipment (M&TE) as discussed in
ANSI/NCSL Z540-1-1994. ANSI N323 provides appropriate guidance for establishing
and operating a calibration program for portable radiation monitoring instruments. While
116 DOE G 441.1-1C
5-19-08
ANSI/NCSL Z540-1 provides guidance that may be useful in such programs, this
guidance need not be applied to calibration of radiation detection instruments used in
operational settings. Radiation detection instruments that are used as calibration standards
should be considered M&TE and used, handled, stored, and calibrated in accordance with
the applicable standards.
9.7.1 Laboratory Records
Guidance for record-keeping can be found in ANSI N323A and ANSI/HPS N13.6,
Practice for Occupational Radiation Exposure Records Systems (ANSI/HPS 1999).
Chapter 13 provides additional guidance for maintaining records consistent with the
requirements of 10 CFR 835.
Section 91
9.7.2 Instrument Calibration Records
A record shall be maintained for results of calibration and maintenance performed for
each instrument [10 CFR 835.703(d)]. Refer to Chapter 9 and ANSI N323A for specific
items that should be included.
9.7.3 Instrument Location
A system for tracking the location of portable survey instruments and for recalling those
instruments for recalibration should be established. The location of portable survey
instruments should be known by the calibration staff or by some identifiable group
assigned with that responsibility. Because instruments may incorporate or be
accompanied by an accountable sealed radioactive source, instrument tracking may be
required as part of the sealed radioactive source control program. See Chapter 15 to
determine if this is the case.
9.8 Laboratory and Staff
The location, design, and use of the calibration laboratory should ensure that conditions
within the laboratory will not affect calibration quality. In addition, the laboratory shall
be designed to keep worker exposures ALARA in compliance with 10 CFR 835.1001 -
1003. The laboratory should also have an appropriate selection of calibration equipment
and should be operated with a properly organized and trained staff. Additional guidance
may be found in Chapter 4 of this Guide and Chapter 3 of the RCS.
9.8.0 Laboratory
The effect of external conditions on the internal environment of the calibration laboratory
should be considered in selecting the facility site. The laboratory should be sited away
from, or otherwise isolated from, sources of mechanical vibration and shock, sources of
electrical and electromagnetic interference, and other potential sources of interference
with the proper calibration of instrumentation. If such potential sources exist, the
DOE G 441.1-1C 117
5-19-08
laboratory should have documentation that demonstrates an absence of adverse effects on
calibration accuracy.
The electrical power should be appropriate for the equipment used, suitably stable, and
free of switching surges and significant line noise. When necessary, local auxiliary
voltage stabilizers, filters, and uninterruptible power supplies should be provided.
The laboratory environment should be controlled to ensure that environmental conditions
do not affect the calibration quality. The conditions described in ANSI N323A, Table 1,
should be considered and implemented, to the extent practicable and appropriate.
Calibration areas should not be used for storage of instruments, equipment, or sources.
Such storage may lead to variable scatter or abnormal ambient radiation conditions.
98.1 Calibration Staff Qualifications
The calibration laboratory manager and the individual in charge of the day-to-day
operation of the calibration laboratory should have the authority to conduct operations
free from any influence that could adversely affect the quality or impartiality of the
services offered. Refer to DOE STD-1107-97, KNOWLEDGE, SKILLS, AND
ABILITIES FOR KEY RADIATION PROTECTION POSITIONS AT DOE
FACILITIES (DOE 1997a) and Chapter 14 for guidance on the recommended education,
training, and skills for these two positions. The laboratory manager should understand the
laboratory protocol, ensure it is followed, and should, at least annually, evaluate staff
competence and the need for training. In smaller operations, the manager may also be in
charge of day-to-day operations.
9.8.2 Calibration Staff Training
Section 92
All staff employed in calibration work shall be trained in radiation safety prior to
receiving occupational exposure [10 CFR 835.901(a)]. Chapter 14 provides additional
guidance.
Apart from radiation safety training, the staff should receive training on the theory of
radiation detectors, interaction of radiation with matter, basic statistics, maintenance of
records, quality assurance, and other topics related to the safe and efficient operation of
calibration equipment.
9.9 Assessments
Internal audits of the radiation protection program shall be conducted such that, over a
three year period, all functional elements are assessed, including program content and
implementation (10 CFR 835.102). Chapter 3 provides guidance on the required internal
audits.
118 DOE G 441.1-1C
5-19-08
10.0 AIR MONITORING
The purposes for conducting an air monitoring program can be characterized as the need
to assess individual exposures to airborne radioactive material, determine the need for
and prescribe appropriate personnel protection from airborne radioactive material, and
provide early warning of unexpected increases in airborne radioactivity levels. The type
of air monitoring to be performed will depend on the purpose of the monitoring and how
the monitoring results will be used. Under 10 CFR 835, air monitoring results are
required to measure the concentrations of airborne radioactive material, determine
posting requirements, determine the effectiveness of the engineered controls and barriers
used to contain and confine radioactive material, determine appropriate protective
equipment and measures, and provide warnings of significantly elevated levels of
airborne radioactive materials. In addition, air monitoring results may be used to estimate
individual intake. 10 CFR 835 establishes the basic elements of an air monitoring
program: periodic air samples to assess actual and potential individual exposures and
real-time air monitoring to provide immediate warning of increases in airborne
radioactive material concentrations.
When implementing an air monitoring program, it is important to achieve a proper
balance between the basic elements of the program -- air sampling and real-time air
monitoring. The balance will depend on the characteristics of each facility and the
justification for the approach taken should be included in program documentation.
The primary difficulty in meeting the air monitoring requirements in 10 CFR 835 is in
collecting samples that can reliably reveal and estimate the magnitude of individual
exposures. However, it should be possible to reliably detect increases in airborne
radioactive material concentrations above baseline levels. This information can be used to
initiate bioassay evaluations to verify whether an exposure has occurred and, if so, to
estimate the magnitude of the exposure.
Real-time air monitoring is performed to provide warning of significantly elevated levels
of airborne radioactive materials. The primary challenge in performing effective real-time
air monitoring is placing the monitors where they will provide a rapid and reliable
warning that an unexpected release has occurred. The number and placement of real-time
air monitors should be optimized. Proper strategy for the placement of real-time air
monitors is critical to the effectiveness of the air monitoring program.
Section 93
The air monitoring program is only one element of a comprehensive radiation protection
program. Therefore, individuals involved with the air monitoring program should
coordinate their efforts with other radiation protection program personnel, particularly
with those involved in contamination control and internal dosimetry.
10.1 Implementation Guidance
Monitoring of airborne radioactivity is required where an individual is likely to receive
an exposure of 40 or more derived air concentration (DAC)-hours in a year or as
necessary to characterize the airborne radioactivity hazard where respiratory protective
DOE G 441.1-1C 119
5-19-08
devices for protection against airborne radionuclides have been prescribed
[10 CFR 835.403(a)]. )]. See Appendix A of Chapter 16 of the Guide for a listing of
values. Real-time air monitoring is required to be performed, as necessary, to detect and
provide warning of airborne radioactivity concentrations that warrant immediate action to
terminate inhalation of airborne radioactive material [10 CFR 835.403(b)].
This chapter describes acceptable methods for establishing and operating an air
monitoring program adequate to demonstrate compliance with 10 CFR 835. The
discussion is divided into the following topics:
• determining the need for air monitoring;
• placement of air sampling and real-time air monitoring equipment;
• selection and operation of air sampling equipment;
• selection and operation of real-time air monitoring equipment;
• sample analysis and data review;
• quality control and quality assurance; and
• administrative controls.
NUREG-1400, AIR SAMPLING IN THE WORKPLACE (NRC 1993), was developed
by the U.S. Nuclear Regulatory Commission to provide technical information on air
sampling for facilities following NRC’s related regulatory guidance. The technical
information provided in this document is useful for DOE facilities using this Guide.
NUREG-1400 contains the following technical information:
• evaluation of the need for air sampling, including air sampling based on potential
intakes and concentrations, and air sampling systems;
• location of air samplers, including purpose of airflow studies, determination of
airflow patterns, and selecting sample location;
• demonstration that air sampling is representative of inhaled air;
• adjustments to derived air concentrations;
• measurement of the volume of air sampled; and
• evaluation of sampling results, including detecting changes in air concentrations
over time, efficiency of collection media, and detection sensitivity.
120 DOE G 441.1-1C
5-19-08
NUREG-1400 should be consulted to obtain pertinent technical information concerning
regulatory guidance provided in this Guide.
10.2 Determining the Needs for Air Monitoring
The decision to perform air monitoring should be based on consideration of both actual
and potential radiological conditions. Actual conditions are typically confirmed by air
sampling results with detectable levels of activity. Potential conditions are identified
through the use of professional judgment and experience regarding the likelihood that a
radiological condition will exist. When evaluating potential conditions, both normal
situations and unusual situations which can reasonably be expected to occur should be
considered. NUREG-1400, (Section 1) provides an acceptable methodology for
evaluating the need for air sampling by predicting likely intakes for some individuals
who might receive a significant intake. This methodology provides an acceptable
approach to justify and document decisions based on professional judgment and
experience.
Section 94
When performing air monitoring to demonstrate compliance with either 10 CFR
835.403(a)(1) or (2), the method used must be appropriate for the existing environmental
conditions, consistent with 10 CFR 835.401(c)(3). Any conflicts between this
requirement and the specific monitoring requirements of 10 CFR 835.403(a) should be
considered in development of the RPP.
10.2.0 Exposure Assessment
Air monitoring through the use of representative sampling is used for the assessment of
an individual's exposure to airborne radioactivity. Air monitoring results may be used to
determine an individual's type and frequency of bioassay measurements and to estimate
an individual's dose from exposure to airborne radioactive material.
Determinations of the need for air sampling should include consideration of occupancy
factors to determine if an individual is likely to receive a 40 DAC-hour exposure in a
year. For example, if a worker is present in a work area only 200 hours per year and
enters no other areas of significant airborne radioactivity, the individual could be exposed
to an air concentration just less than 20% of a DAC without receiving an exposure equal
to or exceeding 40 DAC-hours in a year.
10.2.0.0 Type and Frequency of Bioassay
10 CFR 835 requires that internal dose monitoring programs be conducted for individuals
likely to exceed certain internal dose thresholds [10 CFR 835.402(c)]. The air monitoring
program can provide significant information for determining the type and frequency of
bioassay measurements.
An effective air monitoring program, in combination with an effective and reliable
access control program, can facilitate tracking of an individual's exposure to airborne
radioactive materials measured in DAC-hours. A DAC-hours tracking program should
DOE G 441.1-1C 121
5-19-08
be considered for DOE activities where individuals could routinely be expected to be
exposed to greater than 40 DAC-hours in a year. Internal dose monitoring programs
typically assign bioassay frequency and methods based on actual or anticipated
individual exposures. Therefore, tracking of individual exposures in DAC-hours can
facilitate determination of the type and frequency of required bioassay measurements.
For example, if a radiological worker receives greater than 40 DAC-hours in a year, the
individual would be required to participate in the bioassay monitoring program. The
bioassay frequency and methodology may be determined based on the radionuclides
inhaled and the frequency of intakes or exposure to airborne radioactive material.
10.2.0.1 Estimation of Dose
The estimation of internal dose shall be based on bioassay data rather than air
concentration values unless bioassay data are:
• unavailable;
• inadequate; or
• internal dose estimates based on air concentration values are demonstrated to be
as or more accurate [10 CFR 835.209(b)].
Bioassay data may meet these conditions as a result of instrumentation limitations,
sampling discrepancies, or other conditions. Chapter 5 provides guidance on evaluation
of internal dose from air monitoring data.
If bioassay measurements are not available or their validity is questionable, internal dose
estimates may be determined from the number of DAC-hours tracked for that individual.
When DAC-hours are used for this purpose, any adjustments, such as protection factors
for respiratory protection, shall be documented [10 CFR 835.702(g)]. Additional
guidance is provided in Chapter 5.
Section 95
When using respiratory protection devices for radiological protection, as an initial
approach one should consider selecting a respiratory protection device which has an
assigned protection factor greater than the peak concentration value, in multiples of DAC,
expected. As an alternate approach, to ensure the radiological protection occupational
exposure limit of 5 rem TED is not exceeded, one may establish an administrative control
level for that activity that is much lower than the 5 rem TED limit and use the conversion
of 2.5 millirem per DAC hour and account for the protection factor of the respiratory
protection device and the time in the area. However, there are some considerations before
using this approach. Regardless of the approach taken, the ALARA provisions of 10 CFR
835 would need to be appropriately considered.
DOE has addressed the special case where the sensitivity of the bioassay analysis is
technologically limited (such as with certain plutonium isotopes). Acceptable methods of
dealing with technology shortfalls have been addressed in Chapter 5 and
DOE-STD-1121-2003 (DOE 2003).
122 DOE G 441.1-1C
5-19-08
As required by 10 CFR 835.209(b)(3), when used for determinations of individual dose
equivalents, air sampling results must provide dose determinations that are as or more
accurate than those provided by bioassay. The air sample should closely approximate
both the airborne radioactivity concentration and the physical and chemical properties of
the airborne radioactive material. Personal air monitoring is typically used for obtaining
air samples that are used for dose determination. Chapter 10 provides additional guidance
for situations where air monitoring is used when there is no practical bioassay method.
Normally, real-time air monitoring should not be used in lieu of air sampling when the
results may be used to estimate an individual's dose and intake. The results from real-time
air monitoring may not be representative of the air actually breathed by individuals,
linked to the individual in that area, or sufficient to use in the estimation of internal dose.
10.2.1 Personnel Protection
Air monitoring is performed to determine the need for “Airborne Radioactivity Area”
posting and access controls, evaluate the effectiveness of engineered controls, and
determine the proper respiratory protective device.
10.2.1.0 Need for Posting
10 CFR 835.603(d) requires posting of airborne radioactivity areas. Air sampling may be
used to determine whether an area should be posted as an airborne radioactivity area.
Grab sampling is typically used to determine whether the criteria for posting airborne
radioactivity areas have been exceeded. The sample volume should be sufficient to
ensure the achievement of adequate counting system detection capabilities.
Chapter 12 of this Guide and Chapter 2 of the RCS provide detailed guidance on posting
airborne radioactivity areas.
10.2.1.1 Effectiveness of Engineered Controls
Engineered controls for facilities and systems include measures to preclude and control
releases of airborne radioactive material. Air monitoring should be performed in facilities
and around systems with engineered controls designed to prevent the release of airborne
radioactivity and also following modifications which could affect air flow and ventilation
balance. Fixed-location air sampling should be considered in the design and modification
of facilities where uncontained radioactive material would be used or releases of airborne
radioactive material would be anticipated. Results from fixed-location air sampling are
particularly useful during the startup of a new facility or new operation within an existing
facility to establish baseline airborne radioactive material concentrations and verify
containment integrity.
Section 96
Temporary engineered controls are used to protect individuals when permanent
controls cannot adequately contain radioactive material. When engineered controls,
such as ventilation, vacuum cleaners, or containment devices, are used to reduce or
maintain airborne radioactivity concentrations, air monitoring should be performed to
DOE G 441.1-1C 123
5-19-08
determine the adequacy and effectiveness of the engineered controls. Generally, for
installed controls, such as fume hoods, fixed-location air sampling is preferred,
whereas for temporary controls, such as portable ventilation or use of vacuum
cleaners, grab sampling is preferred. Real-time air monitoring for determining the
adequacy of installed controls may also be appropriate or required. Chapters 4 and 11
of this Guide and the RCS provide guidance on the use of engineered controls.
10.2.1.2 Proper Respiratory Protective Equipment
Respiratory protective equipment is used to reduce an individual's intake of airborne
radioactive materials. Each respiratory protective device is assigned a protection factor
that indicates the degree of protection afforded by the respirator. Respiratory protective
devices should be chosen based on the protection factor and actual or potential airborne
radioactivity levels, taking into account ALARA considerations, other industrial hazards,
and worker safety. DOE requires its respiratory protection programs to be conducted, for
DOE contractors in accordance with 10 CFR 851, and for DOE Federal employees in
accordance with DOE O 440.1B, Worker Protection Program for DOE (Including the
National Nuclear Security Administration) Federal Employees (DOE 2007c).
10 CFR 851 and DOE O 440.1B require adherence to ANSI Z88.2, Practices for
Respiratory Protection (ANSI 1992b) and 29 CFR 1910.134.
An important step in selecting the proper respiratory protective equipment is determining
the actual or potential concentration of airborne radioactivity in the area the individual is
to enter. Air sampling shall be performed as necessary to characterize the airborne
radioactivity hazard where respiratory protection against airborne radionuclides has been
prescribed [10 CFR 835.403(a)(2)]. Typically, grab sampling is used to determine the
airborne radioactivity concentration. Real-time air monitoring may be useful in areas
where substantial work is being performed and airborne radioactivity concentrations
fluctuate,. If the individual is entering an area where the airborne radioactivity
concentration is routinely sampled and is not likely to have changed since air monitoring
was last performed, previously obtained samples may be used to characterize the airborne
radioactivity hazard. When the need for air monitoring is not clear, historical data from
fixed-location air sampling and real-time air monitoring should be analyzed to determine
whether respiratory protection is appropriate. NUREG-1400 provides a methodology for
predicting the potential intakes which can be useful in determining the need for
respiratory protection (Section 1.2).
10.2.2 Early Warning
Real-time air monitoring shall be performed as necessary to detect and provide warning
of airborne radioactivity concentrations that warrant immediate action to terminate
exposure to airborne radioactive material [10 CFR 835.403(b)]. Typically, real-time air
monitoring should be used in areas where unexpected increases in airborne radioactivity
levels could result in an exposure to an individual exceeding 40 DAC-hours in one week.
This exposure is typically representative of a committed effective dose of approximately
100 millirem (1 mSv). To provide the necessary warning, real-time air monitors should
Section 97
124 DOE G 441.1-1C
5-19-08
have alarm capability and sufficient sensitivity to detect airborne radioactivity at these
levels.
Unlike air sampling, the need for real-time air monitoring is based on the likelihood that an
individual will be exposed to an unexpected increase of airborne radioactivity greater than
a given level. The use of real-time air monitors is based upon the expectations of discrete
events, rather than determination of ambient airborne radioactivity concentrations.
Examples of situations for which real-time air monitoring may be appropriate include the
following:
• within or at the boundaries of areas where work is performed that creates or has
the potential to create airborne radioactivity;
• within or at the boundaries of areas where a power failure or other disruption of
engineered controls could result in the release of airborne radioactivity; and
• within or at the boundaries of established airborne radioactivity areas when work
is being performed that has the potential to significantly increase the ambient
airborne radioactivity levels.
These examples serve to emphasize that real-time air monitoring is intended to protect
individuals both inside and outside of work areas.
Real-time air monitors may not be appropriate or necessary in established airborne
radioactivity areas where ambient airborne radioactivity levels are not expected to
increase (i.e., unexpected releases are not likely). Grab samples are typically used to
monitor airborne radioactivity levels and to detect trends. Historical workplace air
monitoring records and knowledge of the type of work to be performed in the area can be
used to justify the decision not to use a real-time air monitor.
10.3 Placement of Air Sampling and Real-Time Air Monitoring Equipment
Once the need for air monitoring has been established, the monitor/sampler location(s)
can be determined. Location is important because inappropriately placed equipment may
not provide representative results. Concentrations of airborne radioactivity in an area can
vary greatly from one location to another.
In general, air sampling equipment is most effective when located close to individuals
to provide an indication of airborne radioactivity levels to which they are exposed.
Real-time air monitoring equipment should be located to provide an early warning to
individuals of a significant increase in levels of airborne radioactive material.
When selecting locations for air sampling and real-time air monitoring equipment,
consideration should be given to the locations of possible release points and workers,
DOE G 441.1-1C 125
5-19-08
the purpose of the sample, and room air flow patterns. The cost of real-time monitors
and the time required to collect and analyze sample media limit the number used in a
facility. This consideration, together with the need for a rapid response to an unplanned
release, means that optimal placement is critical. The technical basis for air sampling
and real-time air monitoring equipment placement should be documented. The
following considerations should be included in technical basis documentation:
10.3.0 Locations of Release Points and Individuals
Actual and potential release points in an area should be identified. Actual release points
can be determined from past operating experience. Potential release points can be
determined from a review of safety analysis documentation for the facility. The location
of individuals in relation to these release points should also be identified. Finally,
occupancy times for individuals near the release locations should be estimated.
Section 98
10.3.1 Purpose of Sample
The purpose of air monitoring is to measure the concentrations of airborne radioactive
material to:
• estimate individual intakes;
• determine posting requirements;
• determine the effectiveness of the confinement of radioactive material;
• determine appropriate protective equipment and measures; and
• provide warnings of significantly elevated levels of airborne radioactive
materials.
To estimate exposures and intakes, a sample representative of the air breathed by the
individual should be taken. The air sampling equipment should be positioned in the
vicinity of the individual, taking into consideration the air flow path from likely release
points to the individual. Alternatively, if the purpose is to indicate containment or
confinement control, then air sampling equipment should be positioned near the release
point, or likely release point, in a downstream direction. The downstream direction can be
determined by performing air flow studies.
Real-time air monitoring equipment, such as continuous air monitors (CAMs), should be
positioned strategically in the affected area or at the affected area boundaries. If there is
only one potential release point in an area, then placement of the real-time air monitor as
close to the release point as possible in a downwind direction may be adequate. If there
are multiple release points and a limited number of real-time air monitors, such that one
cannot be placed near each release point, then the real-time air monitors should be placed
126 DOE G 441.1-1C
5-19-08
at locations expected to provide the most reliable indication of a release with the least
delay from the onset of the release, should one occur. The general objective is to provide
a rapid and reliable warning to the greatest number of individuals that a release has
occurred.
10.3.2 Room Air Flow Patterns
Air flow studies should be used to determine the placement of air monitors and facilitate
the interpretation of the results of air monitoring. The extent of air flow testing will
depend on the type of air monitoring being performed. More extensive air flow testing
should be performed when locating fixed-location air samplers and real-time air monitors
than when locating air samplers being used as grab samplers for short duration jobs. Air
flow studies may be useful in placement of grab samplers to ensure that samples are
indeed representative. Air flow testing is not needed for personal air monitoring since
proper placement of personal air samplers on the worker ensures collection of
representative samples. Acceptable methods for determining air flow patterns are
discussed, in detail, in NUREG-1400 (Section 2.3).
The radiation protection organization should be aware of facility characteristics,
operations, and changes that may affect airflow patterns. The radiation protection
organization should perform and document a review of the adequacy of sampling and
monitoring systems periodically and as part of any facility or operational change
affecting radiological control. The periodicity of the review should be documented as part
of the technical basis for the placement of the air sampling and real-time monitoring
equipment.
Placement of fixed-location air sampling and real-time air monitoring equipment should
be reevaluated after changes to the ventilation system have been made or after equipment
or structures have been added that may influence air flow. Air flow patterns in a given
area should be reevaluated at a minimum every 36 months or when major room or
building renovation has occurred.
Section 99
10.4 Air Sampling Equipment
Types of air sampling equipment include fixed-location air samplers, portable air
samplers (high-volume and low- volume), and personal (lapel) air samplers. Selection of
air sampling equipment should be based on the type of sample being collected (e.g.,
breathing zone air sample, source-specific air sample, or grab air sample). Detailed
technical information regarding air sampling systems is provided in NUREG-1400
(Section 1.3).
10.4.0 Breathing Zone Air Monitoring
Breathing zone air monitoring should be used when air monitoring results are used to
assign internal doses and when determining the effectiveness of respiratory protection
equipment. Breathing zone air monitoring involves collecting an air sample from the
individual's breathing environment, making allowances to eliminate interferences the
DOE G 441.1-1C 127
5-19-08
samplers themselves may have on the individual's activities. Such air samples provide the
most reliable indicator of the potential for inhalation of airborne radioactivity and can
provide an estimate of the magnitude of possible exposures. Breathing zone air samples
can be collected using fixed-location air samplers, portable air samplers, or personal air
samplers. When fixed-location air sampling equipment will not provide a representative
indication of the individual's breathing zone, then personal air sampling equipment
should be used. When using personal air samplers, the radiation protection staff should
ensure that the low flow rate will allow collection of enough radioactive material to meet
the minimum sensitivity requirement for air monitoring.
Breathing zone air monitoring should also be used in areas where workers are likely to
exceed an exposure of 40 DAC-hours in a year, and to identify possible worker internal
exposures and the need for follow-up bioassay measurements. Breathing zone air
monitoring data may be used to estimate intakes of radioactive material and subsequent
internal dose in accordance with the requirements of 10 CFR 835.209(b).
10.4.1 Source-Specific Air Sampling
Source-specific air sampling is the collection of an air sample near an actual, or likely,
release point in a work area. Fixed-location and portable air samplers can be used for
source-specific air sampling to verify containment or confinement integrity, document
airborne radioactive material levels (can be used for determining the need for posting),
and provide information relevant to determining when the use of respiratory protective
devices is necessary.
10.4.2 Grab Sampling
Grab sampling should be used for temporary or non-routine situations and as a backup for
other types of air sampling in the event of equipment failure. Grab sampling can be used
to determine whether areas should be posted as airborne radioactivity areas and
respiratory protective devices should be used for protection against airborne radioactive
material. Portable air sampling equipment should be used for operations requiring grab
sampling. Sample flow rates may vary depending upon the specific application, but
should allow collection of a sample volume adequate to ensure that the minimum
detectable activity of the sampling and counting system corresponds to an intake of no
greater than 2% of an ALI.
10.4.3 Operability Checks
Section 100
Operability checks of air monitoring equipment are used to ensure that the equipment is
functioning properly prior to and during use. Operability checks shall be performed
routinely on flow rate meters [10 CFR 835.401(b)(4)]. In addition, because excessive
dust loading interferes with alpha particle detection and reductions in flow rate result in
uncertainties in the total air volume sampled, periodic verification of flow rates should be
performed. At a minimum, the flow rates should be verified when sample media are
128 DOE G 441.1-1C
5-19-08
exchanged. Rapid or significant changes in flow rate should be investigated immediately.
These instances may indicate the need for more frequent changes of sample media or loss
of integrity of filter or sampling equipment. The sample flow rate used for estimating air
concentration should be the average of the flow rate when the sample was started and the
flow rate when the sample medium was removed.
10.5 Real-Time Air Monitoring Equipment
10.5.0 Instrument Selection
Instruments used for real-time air monitoring shall be appropriate for the type(s), levels,
and energies of radiation(s) encountered in the workplace [10 CFR 835.401(b)(2)] and
for existing environmental conditions [10 CFR 835.401(b)(3)]. The selection of real-time
air monitors should be based on the characteristics of the airborne radioactive material,
the anticipated range of airborne radioactive material concentrations and the possible
variations of the concentrations over time. The type of real-time air monitor used depends
on the type of facility in which it is used, the radioisotopes being monitored, and the
physical and chemical forms of the radioactive material. Commonly used monitors at
DOE facilities are: particulate-radioactive material continuous air monitors (e.g., alpha
CAMs and beta CAMs); impactor air monitors; and gaseous radioactive material mon-
itors. Monitors that use background-reduction methods (e.g., activity-fractioning
monitors and pseudo-coincidence monitors) may also be used. CAMs should not be used
when high levels of contamination or other factors would prevent them from providing
reliable results. Use of CAMs for particulates and noble gases is acceptable; however,
detection of radon requires a different monitoring methodology that provides real-time
information and alarm capabilities. In these cases, the use of working level monitors may
be acceptable. If such monitoring instruments are taken credit for in the documented
safety analysis, their initial quality and maintenance level should also be appropriate,
including any that of any associated safety system hardware and software.
If a real-time air monitor is likely to become highly contaminated or if unreasonably high
flow rates are needed, then one of the following techniques can be used: (1) periodic
direct reading of fixed air sample media by using portable survey instruments; or (2)
periodic grab samples with rapid analysis.
10.5.1 Alarm Set Points
Real-time air monitors should be capable of measuring 1 DAC when averaged over 8
hours (8 DAC-hours) under laboratory conditions. Alarm set points for real-time air
monitors used for routine monitoring should be set at the lowest practical level so as to
accurately indicate loss of containment or the need for corrective action without causing a
significant number of false alarms. When monitoring for alpha emitters shows high radon
and thoron concentrations, an alarm set point of up to 24 DAC-hours may be acceptable.
In all cases, the actual alarm set point established for each unit and the technical basis for
the alarm set points should be documented. If real-time monitors are used during work
requiring the use of respiratory protective devices, the alarm set point can be adjusted to
Section 101
DOE G 441.1-1C 129
5-19-08
provide an early warning that the applicable respiratory protection factor may be
exceeded.
10.5.2 Alarm Capabilities
Real-time air monitors shall have alarm capability and sufficient sensitivity to alert
potentially exposed individuals that immediate action is necessary to minimize or
terminate inhalation exposure [10 CFR 835.403(b)]. The alarm should be audible and
have a distinctive tone or sound so that it is not confused with other work area alarms,
such as those for criticality. The audible alarm intensity should be a minimum sound
level of 75 dB at 15 cm. In areas that have a high ambient noise level (>95 dB), a visual
alarm should activate with the audible alarm. The visual alarm should be distinctive so
that it cannot be mistaken for other types of alarms. If the monitor is installed outside the
work area, there should be additional audible and visible alarm indicators inside the area
to ensure that individuals are promptly notified. ANSI N42.17B, Performance
Specifications for Health Physics Instrumentation - Occupational Airborne Radioactivity
Monitoring Instrumentation (ANSI 1989d), provides additional guidance regarding alarm
capabilities.
10.5.3 Operability Checks
Operability checks shall be routinely performed on real-time air monitoring equipment
[10 CFR 835.401(b)(4)]. The following periodic operability checks should be performed
at the frequency indicated:
• Daily operability checks should include positive airflow indication, presence of a
typical non-zero response to background activity, and internal check sources or 60
Hz electronic checks when available. In addition, daily checks should verify the
control settings and the operability of strip chart recorders, if used.
• Weekly operability checks should verify instrument response with a check source
or with ambient levels of radon or thoron daughters. If an instrument response
falls outside established response limits, it should be taken out of service.
• Once each month, every real-time air monitor in active service should be tested to
ensure proper operation of the alarm. Alarm testing should also verify alarm
response when the detector fails.
The adequacy of battery power should be tested monthly for real-time air monitors that
rely on battery backup power in an emergency. Similarly, for those monitors using
emergency power supplies, the adequacy of the emergency power for monitor operation
should be verified as a part of the emergency power checks.
10.6 Sample Analysis and Data Review
Provisions for detecting changes in radiological conditions, detecting the gradual buildup
of radioactive material, verifying the effectiveness of engineered and process controls in
130 DOE G 441.1-1C
5-19-08
containing radioactive material, and identifying and controlling potential sources of
individual exposure to radioactive material require that certain evaluations of air
monitoring results be performed [10 CFR 835.401(a)(3-6)]. Additional technical
information regarding evaluation of sampling results is provided in NUREG-1400
(Section 6).
Section 102
Air sample results should be evaluated as quickly as practical for special situations, such
as the evaluation of the need for respiratory protection, area evacuation (if necessary),
individual intake, and relief from use of respiratory protective devices. Preliminary
assessments of air samples using field survey techniques should be performed promptly
upon removing the sample from its holder. When background levels of radon and thoron
daughters interfere with evaluation of alpha air samples, prompt field assessments may
not be possible. Procedures should define the methods for counting samples in the field
(i.e., detection equipment to use, configuration of the detector and the sample, and
conversion factors). Prompt field assessments are not required for fixed-location,
portable, or personal air samplers used to routinely sample the individual’s breathing
environment unless upset conditions have been identified.
Appendix A of 10 CFR 835 has a provision that allows the adjustment of DACs to reflect
the actual physical characteristics (e.g., particle size) and chemical characteristics (e.g.,
solubility in lung fluid) of the airborne radioactive material. Guidance on making
adjustments to DACs can be found in DOE STD-1121-2003.
10.7 Quality Control and Quality Assurance
Records of the results of air monitoring shall be documented and maintained
[10 CFR 835.703(a)]. To meet this requirement, quality control should be applied to all
phases of the air monitoring program to include sample identification, handling, and
storage, air sampling and real-time air monitoring equipment, counting room equipment,
and record-keeping.
10.7.0 Sample Identification, Handling, and Storage
All samples collected should be assigned an identification number that cannot be
confused with samples taken at another location. Sample designators should be placed on
all collection envelopes or containers to reduce the possibility of mislabeling a sample.
Other information on the envelope should include the date and time of sample collection
and the sample flow rates.
Samples should be handled carefully to prevent cross-contamination between samples
and should be placed in appropriately labeled containers to reduce the potential for loss.
Arrangements should be made for sample storage prior to counting and between counts if
multiple counts are required.
DOE G 441.1-1C 131
5-19-08
Each organization should develop a tracking system for its air samples that permits
positive identification of any individual sample, while indicating the results of the sample
analysis, the flow rate, the dates and times of sample collection, the individual
performing the collection, and pertinent information about the sample collection system.
A sample log book or a computerized database should be maintained. This should contain
the necessary entries to provide a complete history of the sample and its analysis.
10.7.1 Air Sampling and Real-Time Air Monitoring Equipment
Components of air sampling and real-time air monitoring systems (i.e., air mover, CAM
detector, portable air sampler, fixed sampling head, and sampling line) should be
uniquely identified. Labeling of equipment and maintaining a log of equipment locations
will allow the radiation protection staff to locate a sampling or monitoring unit should
there be a questionable sample result.
Section 103
Equipment used for air monitoring shall be periodically maintained and calibrated on an
established frequency [10 CFR 835.401(b)(1)]. ANSI N42.17B indicates that air flow
meters, differential pressure indicators, and other devices used to determine volumetric
flow rates of air samplers and monitors should be calibrated to within +_15% of the true
reading. Calibrations should be performed annually at the atmospheric pressure and
temperature conditions that are expected during sampling conditions, or the appropriate
correction factor should be applied during the calculation of the flow rate.
Detectors in real-time air monitors should be calibrated with a calibration source(s)
typical of the radionuclide(s) present in the work environment. The calibration should
also be performed after failure of an operability test. Calibration sources should be
traceable to the National Institute of Standards and Technology (NIST).
At a minimum, air inleakage tests should be performed on real-time air monitors when
they are calibrated, whenever a monitor is replaced, and whenever a monitor's rubber
O-rings or other seals are replaced. Ideally, tests for inleakage should also be performed
during monthly or quarterly performance tests. Care should be exercised to prevent
equipment damage during testing. For example, rapid changes in sample line pressure on
some real-time air monitors may damage the detector.
Procedures should be established to address the appropriate review and use of data when
a critical component of an air monitoring system (e.g., detector or airflow meter) is
determined to be out of calibration. Procedures should be established to review the
accuracy of any data generated by that particular equipment since it was last calibrated.
10.7.2 Counting Room Equipment
Counting room equipment shall be routinely tested for operability
[10 CFR 835.401(b)(4)]. Daily performance checks of background count rate and
radiation response (source checks) should be performed on the counting system.
132 DOE G 441.1-1C
5-19-08
10.7.3 Audits
The radiation protection organization should perform and document a review of the
adequacy of air monitoring systems as part of any facility or operational changes
affecting radiological control. In the absence of such changes, a review should be
conducted annually. The air monitoring program should be reviewed as a functional
element in the internal audit program required under 10 CFR 835.102.
10.7.4 Recordkeeping
10 CFR 835 establishes specific requirements for the documentation of air monitoring.
Chapter 13 of this Guide and the RCS discuss these requirements and provide detailed
guidance.
10.8 Administrative Controls
10.8.0 Technical Basis Document
A document should be developed that provides the technical basis for selecting, placing,
and operating air sampling and real-time air monitoring equipment. This document
should include information such as:
• performance and acceptance testing of new equipment;
• filter media characteristics;
• sample transport line losses (if applicable);
• flow rate and duration of sample collection;
• identification of relevant supplies and equipment by manufacturer, make, and
model;
• performance of air flow studies;
• rationale for the use and placement of air samplers and real-time air monitors;
• rationale for demonstrating that air samples are representative of air breathed by
workers;
• list of, and a facility map showing, actual locations of air sampling and real-time
air monitoring equipment;
Section 104
• calculation of the decision level, minimum detectable activity, and minimum
detectable concentration for sampling/counting configurations;
• procedures for sample analysis;
DOE G 441.1-1C 133
5-19-08
• procedures for sample accountability; and
• routine maintenance and calibration of equipment.
This information should be readily available to radiation protection staff and should be
reviewed periodically and revised as necessary.
10.8.1 Written Procedures
Written procedures should be available for:
• collecting air samples;
• performing operability checks of air sampling and real-time air monitoring
equipment;
• calibrating flow rate meters;
• calibrating any radiation detectors that are part of the air monitoring equipment;
• conducting air flow studies to aid in the placement of air sampling and real-time
air monitoring equipment; and
• interpreting the air monitoring results.
Other written procedures should be established for the following:
• counting room staff, on the operation and routine maintenance of air sample
counting equipment, including the development and continued use of source
count statistical control charts.
• radiochemistry staff, on the performance of special analyses.
Any changes in procedures used for monitoring in the workplace shall be documented
[10 CFR 835.704(e)].
134 DOE G 441.1-1C
5-19-08
11.0 RADIOACTIVE CONTAMINATION CONTROL
Work with unsealed quantities of radioactive material creates the potential for generating
radioactive contamination. 10 CFR 835 requires, in part, a contamination control program
sufficient to provide warning of the presence of surface contamination and to prevent the
inadvertent transfer of contamination at levels exceeding specified values outside of
radiological areas under normal operating conditions.
An acceptable contamination control program incorporates two types of control: (1)
Engineered control, and (2) administrative control. Contamination monitoring is part of
and verifies the effectiveness of the contamination control program.
In implementing a contamination control program, engineered controls that control
contamination at the source are the most important element. Engineered controls
incorporated into older facilities may not be sufficient to meet modern contamination
control standards. The engineered controls used in a contamination control program may
include temporary containment and ventilation, which may be the primary methods of
controlling airborne radioactivity and internal exposures to workers in older facilities,
during relatively short-term operations and maintenance, and in other situations in which
permanent engineered controls are unavailable or inadequate. For example, a
permanently installed high efficiency particulate air (HEPA)-filtered ventilation system
may be included as a physical design feature in a facility to control airborne radioactive
material concentrations during routine operations, but a temporary HEPA-filtered
ventilation system may be used as an engineering control during certain maintenance
activities. Similarly, a drain system may be included as a physical design feature to route
contaminated fluids to a controlled collection point, but temporary drains may be
installed as engineered controls during system breach. Finally, administrative controls,
including access restrictions and the use of specific work practices designed to minimize
contamination transfer, should be used as the tertiary method to control exposure to
contamination hazards. These elements of a contamination control program are not
independent. The permanent engineered controls included in a facility will dictate the
types and levels of administrative controls and engineered controls that are possible and
necessary.
Section 105
A contamination control program is an essential element of a comprehensive radiological
control program. In this Guide, when another element of a radiological control program
interfaces with the contamination control program, the appropriate chapter is referenced
and the topic of interest is listed as it applies to contamination control. Because of these
interfaces, individuals involved with the contamination control program should interact
with personnel working in other elements of the radiological control program,
particularly with individuals involved in instrument calibration, posting and labeling, air
monitoring, internal and external dosimetry, As Low As Is Reasonably Achievable
(ALARA), training, and record-keeping programs.
DOE G 441.1-1C 135
5-19-08
Detailed information on contamination controls applicable to specific radiological
hazards is provided for tritium facilities, in DOE-HDBK-1129-2007, TRITIUM
HANDLING AND SAFE STORAGE (DOE 2007d).
11.1 Implementation Guidance
Activities that have the potential to generate surface contamination should be evaluated to
ensure appropriate controls are established. To the extent practicable, contamination
controls should be consistent to facilitate effective implementation by affected
individuals. This chapter describes methods for establishing and operating an acceptable
contamination control program. The discussion is divided into the following topics:
• Contamination Control Program Management;
• Engineered Controls;
• Administrative Control; and
• Contamination Monitoring.
Note that the requirements of 10 CFR 835.1101-1102 and the values provided in
10 CFR 835 Appendix D (Surface Contamination Values) apply only to radioactive
material that is present in the form of surface contamination. See Appendix D of Chapter
16 of the Guide for a listing of values. The storage, movement, and use of radioactive
material in other forms (e.g., material that is intrinsically radioactive or that has been
made radioactive through activation processes) should be controlled consistent with
applicable requirements in 10 CFR 835, including the training requirements under
10 CFR 835.901, the ALARA controls required under 10 CFR 835.101 and 835.1001-
1003, and the controlled area maximum yearly dose expectation provided in
10 CFR 835.602.
11.2 Contamination Control Program Management
Common characteristics of effective contamination control programs include:
• strong, written upper management commitment to control of contamination in the
workplace;
• consistent line management implementation of required controls through
established procedures, training, and frequent supervision;
• detailed work planning, including effective hazards analysis, pre-job briefings,
and post-job debriefings; and
• consistent program support by affected individuals.
136 DOE G 441.1-1C
5-19-08
Management commitment should be established in a written policy which may be
included in the ALARA Policy statement or other policy-level document. The policy
should be implemented by written procedures, technical work documents, and
radiological work permits commensurate with the hazards and required controls and
sufficient to ensure consistent program implementation given the education, training, and
skills of the affected individuals. Guidance on developing written procedures and on
ensuring the appropriate education, training, and skills of affected individuals is provided
in Chapter 3. Guidance on radiation safety training is provided in Chapter 14. The
radiological control manager should be responsible for the development of the
contamination control program, including associated design reviews.
Section 106
Contamination control is the responsibility of everyone involved in radiological
activities. All individuals working with radioactive material should follow established
procedures that meet or exceed the guidance provided in this Guide and applicable DOE
Orders and regulations. Line managers should be responsible for overseeing program
implementation by their subordinates.
Guidance on effective planning for work with radiological hazards is provided in Chapter
4 of this Guide and Chapter 3 of the RCS.
11.3 Engineered Controls
Appropriate controls that prevent the inadvertent transfer of removable contamination to
locations outside of radiological areas under normal operating conditions shall be
maintained and verified [10 CFR 835.1102(a)]. 10 CFR 835.1001 requires measures to be
taken to maintain radiation exposure as low as is reasonably achievable through
engineered controls and administrative controls. The primary methods used shall be
engineered controls (e.g., confinement, ventilation, remote handling, and shielding).
Administrative controls shall be employed only as supplemental methods to control
radiation exposure [10 CFR 835.1001(a)].
DOE recognizes the fact that the design and operating history of its facilities and the
nature of existing contamination hazards may make control of contamination
problematic, particularly in outdoor areas where legacy contamination may exist.
Therefore, DOE regulations do not require that the controls implemented to prevent the
transfer of removable contamination be impervious to ensure regulatory compliance.
However, the controls should be appropriate to the extent of the hazard and the potential
adverse effects that may result from such transfer. Should the potential exist for
radioactive contamination to be transferred outside of posted or controlled radiological
areas (i.e., as a result of human or animal intrusion, containment or system failures,
planned work activities, or natural forces), enhanced monitoring and control programs
should be developed and implemented to identify affected areas and ensure timely
detection of the transfer and institution of appropriate controls over the affected area as
required by 10 CFR 835 and further explained in this Guide.
DOE G 441.1-1C 137
5-19-08
Radiological control is affected by human performance and engineered design features.
General and radiological design criteria for new facilities and major modifications to
existing facilities are provided in 10 CFR 835 and DOE O 420.1B, Facility Safety (DOE
2005d). The design of facilities currently under construction or modification should be
planned and evaluated for adherence to the applicable criteria. The effectiveness of
design features should be evaluated through performance of area and individual
monitoring. See Section 11.5 of this Guide and Chapter 5 of the RCS for further
information regarding contamination monitoring.
Engineered controls that should be considered to enhance control of workplace
contamination include:
• containment of process materials to the maximum practicable extent;
• components and materials that minimize leakage across seals;
• catch basins and controlled drains from potential leakage points;
• use of multiple barriers as necessary to control the spread of contamination. (For
instance, a room, system or vessel that contains radioactive material should be
designed and operated to retain that material, and should also be equipped as
necessary with drain and ventilation systems to direct any leakage that may occur
to appropriate collection systems);
Section 107
• adequate working space around serviceable components to facilitate maintenance
and repairs;
• filtered ventilation from areas of lower to areas of higher contamination levels;
• adequate space for donning and removal of protective clothing and individual
frisking in low-background areas; and
• location of office and break areas away from radiological areas.
In addition to the above, facility design, including materials selected, shall include
features that facilitate operations, maintenance, decontamination, and decommissioning
[10 CFR 835.1002(d)]. These activities should be facilitated by limiting the size of any
contaminated areas and the magnitude of the contamination levels within those areas. To
the maximum possible extent, materials used should be readily decontaminated using
non-hazardous compounds, particularly water or steam. Smooth, corrosion resistant
surfaces and rounded edges also facilitate decontamination. More detailed information on
design features is provided in Chapter 4 of this Guide and Chapter 3 of the RCS.
When permanent engineered controls are not sufficient to prevent the spread of
contamination in the workplace, temporary engineered controls, such as containment
devices and portable or auxiliary ventilation, should be installed. These circumstances
138 DOE G 441.1-1C
5-19-08
arise frequently during maintenance, modifications, and decontamination and
decommissioning. Planning for such activities should include evaluation of the potential
for contamination spread and the effectiveness of engineered controls to reduce such
potential, and, to the extent that engineered controls will not be effective, prescription of
administrative controls to limit the spread of contamination.
Temporary containment devices may be particularly useful in controlling contamination
spread resulting from system leaks and from maintenance that requires contaminated
system breach. These devices range in complexity from simple plastic catch-basins
suspended below leakage points to complex portable buildings used to enclose an entire
work area. Many commercially-available designs include provisions for glove and
equipment ports, ventilation, and contamination reduction exit portals.
Portable air handling systems used in contaminated areas, including vacuum cleaners,
should be equipped with HEPA filtered exhausts or have their exhausts directed to
installed systems that are so equipped. These provisions may not be necessary in areas
where only tritium or radioactive noble gases are present or when the material to be
vacuumed is wet enough to preclude re-suspension after entry into the system collection
chamber. Improper use of vacuum cleaners and portable air-handling equipment may
result in the generation of airborne radioactive material or removable surface
contamination. Extended use of air handling equipment may result in a significant
build-up of radioactive material in the ductwork and filters. Periodic monitoring of the
exhausted air and accessible equipment surfaces should be performed to assess the
radiological impact of equipment operation. Chapter 4 of the RCS provides more detailed
information regarding use of portable ventilation units and vacuum cleaners.
Section 108
Although use of the devices discussed above has been proven effective in reducing
contamination spread and the associated decontamination costs, these benefits must be
weighed against the potential costs. Use of engineered controls may require expenditure
of worker dose to set up, work in, maintain, and remove the device. There may be
financial costs associated with device purchase or manufacture, training, possible reduced
productivity, and device or component set-up, maintenance, and disposal. These factors
are considered in implementation of an effective ALARA program, which is discussed in
more detail in Chapter 4.
11.4 Administrative Control
When the use of engineered controls to limit individual exposures is impractical,
administrative controls shall be implemented to maintain exposures ALARA
[10 CFR 835.1001(b)]. To control the spread of contamination and limit individual
exposures, a graded, multiple-tier system should be used in and around contaminated
areas. The effectiveness of the controls should be verified through the conduct of
contamination monitoring, as discussed in Section 11.5 of this Guide and Chapter 5 of the
RCS.
DOE G 441.1-1C 139
5-19-08
11.4.0 Work Authorizations
Guidance on the use of work authorizations is provided in Chapter 4 of this Guide and
Chapter 3 of the RCS.
11.4.1 Access Control
Control of entry to contaminated areas is necessary to ensure that personnel entering the
area are informed of the radiological status and potential hazards and are provided with
the appropriate protective apparel and equipment. Control of egress from contaminated
areas ensures that radioactive material is not inadvertently removed from the area by
personnel or equipment. Efforts should be made to limit the degree of contamination and
the size and number of contaminated areas in the facility, thereby limiting the need for
use of protective clothing and the undesirable side effects of restricted access to facility
equipment, heat stress, and radioactive waste generation.
11.4.1.0 Entry Controls
Protective clothing shall be required for entry into contaminated areas where removable
contamination levels exceed the values provided in Appendix D of 10 CFR 835
[10 CFR 835.1102(e)]. The type of protective clothing required should be prescribed
based upon considerations of contamination levels, chemical and physical form of the
contaminant, activities to be performed, and area accessibility. Other area and activity
hazards, such as heat, flame, hazardous chemicals, physical obstructions, electrical shock,
and limited visibility, should be considered when prescribing protective clothing.
Appendix C "Compliance Guidelines" of 29 CFR 1910.120 (OSHA 1974) provides
guidance on these considerations as follows:
The use of PPE can itself create significant worker hazards, such as heat stress,
physical and psychological stress, and impaired vision, mobility, and communication.
For any given situation, equipment and clothing should be selected that provide an
adequate level of protection. However, over-protection, as well as under-protection,
can be hazardous and should be avoided where possible.
Two basic objectives of any PPE program should be to protect the wearer from safety
and health hazards, and to prevent injury to the wearer from incorrect use and/or
malfunction of the PPE. To accomplish these goals, a comprehensive PPE program
should include hazard identification, medical monitoring, environmental surveillance,
selection, use, maintenance, and decontamination of PPE and its associated training.
Section 109
The written PPE program should include policy statements, procedures, and
guidelines. Copies should be made available to all employees, and a reference copy
should be made available at the worksite. Technical data on equipment, maintenance
manuals, relevant regulations, and other essential information should also be
collected and maintained.
140 DOE G 441.1-1C
5-19-08
Multiple layers of protective clothing should be prescribed for areas in which the
removable contamination levels exceed 10 times the values provided in Appendix D
of 10 CFR 835, consistent with the consideration provided above. When penetration
of the protective clothing by the contaminant is likely, such as during activities likely
to induce heavy sweating or otherwise wet the individual, an additional layer of
impenetrable clothing should be considered. In some cases, provision of an
impenetrable plastic sheet for sitting or kneeling will be adequate and will reduce the
hazards of heat stress. Additional guidance is provided in Chapter 3 of the RCS.
Prior to unescorted access to radiological areas (including contaminated areas) and
prior to performing unescorted radiological work, each individual shall complete
radiation safety training commensurate with the hazards in the area and the required
controls [10 CFR 835.901(b)]. Guidance on radiation safety training is provided in
Chapter 14 of this Guide and Chapters 3 and 6 of the RCS.
11.4.1.1 Egress Controls
Exits from contaminated areas should include provisions to facilitate retention of
contamination in the area and for monitoring of individuals and the area to ensure
control has been maintained. Undress methods should be prescribed to minimize the
potential for contamination spread. When complex methods are necessary for
removal of multiple layers of protective clothing, assistance should be provided.
Individuals exiting contaminated areas shall be monitored, as appropriate, for the
presence of surface contamination [10 CFR 835.1102(d)]. At a minimum, individuals
exiting contaminated areas should perform a whole body frisk, using either portable
or automated devices. The use of automated whole body frisking devices should be
considered due to the consistency of results achievable with such devices. For
individuals exiting areas where the only contaminated areas are laboratory bench
surfaces or fume hoods, or where contamination potential is limited to specific
portions of the body, the frisking should concentrate on affected areas. Exiting
individuals should be trained to frisk any personal items carried into the area.
Personal items include papers, pens, jewelry, security badges, dosimeters, and other
items commonly used within the area. Necessary monitoring of tools or other material
and equipment should be performed by trained radiological control personnel. See
Section 11.5.2 of this Guide for information concerning necessary monitoring of
material and equipment.
The instruments and techniques used for contamination monitoring shall be
appropriate for the types, levels, and energies of the radiations encountered and for
the existing environmental conditions, be periodically calibrated and maintained, and
be routinely tested for operability [10 CFR 835.401(b)]. Detailed guidance on
selecting, calibrating, and using portable contamination control instruments is
provided in Chapter 9 of this Guide and Chapter 5 of the RCS.
DOE G 441.1-1C 141
5-19-08
Section 110
Because skin contamination by certain radioisotopes, such as tritium, cannot be reliably
detected by currently available hand-held or automated monitoring instrumentation,
individual frisking is not an appropriate means of detecting skin contamination, as
discussed in 10 CFR 835.1102(d). When individual exposure to such contamination
hazards is possible, additional emphasis should be placed on radiobioassay programs and
routine contamination and air monitoring programs. Detailed guidance on radiobioassay
and air monitoring programs is provided in Chapters 5 and 10 of this Guide.
If background radiation levels or other conditions at the exit point preclude performance
of personnel frisking, the exit point should be relocated to an area of lower background
levels. If relocation of the exit point is not practicable, individuals should proceed
directly from the exit point to an appropriate area to perform a whole body frisk. The
travel path should be monitored frequently for contamination spread during use and after
the detection of any contamination at the frisking station.
The instruments used for frisking should be capable of detecting contamination at or
below the total surface contamination values provided in Appendix D of 10 CFR 835.
Individuals should be trained in proper frisking techniques, including detector speed and
distance, and proper techniques should be enforced through frequent line management
observation. Frisking for skin contamination while wearing protective clothing will not
generally provide detection capability adequate to ensure compliance with 10 CFR 835.
Frisking for hot particles may require special techniques and should reflect considerations
of source to detector size effects. Such factors should be included in radiation safety
training and reinforced through line management attention.
11.4.1.2 Posting and Labeling
Guidance on area posting and contaminated item labeling is provided in Chapter 12 of
this Guide, and Chapters 2 and 4 of the RCS.
11.4.2 Areas of Fixed Contamination
The control measures discussed above have been proven effective in minimizing the
generation and spread of removable contamination. However, these measures may not be
appropriate for implementation in areas having only fixed contamination. When surfaces
with fixed contamination are located within a radiological area, the radiological area
posting and entry control requirements provide for adequate control of entry and egress.
Additional control measures may be necessary to prevent inadvertent or unauthorized
removal of the fixed contamination by methods that disturb the surface. 10 CFR 835
establishes specific requirements for controlling such locations outside of radiological
areas. Although fixative coatings may be used to bind the contamination to the surface,
such usage should be minimized and removable contamination levels should be reduced
to levels that are ALARA prior to application of the coating.
When located outside of radiological areas, accessible areas in which only the fixed
contamination levels exceed the total surface radioactivity values provided in Appendix
142 DOE G 441.1-1C
5-19-08
D of 10 CFR 835 (i.e., removable contamination levels are below the Appendix D
removable surface radioactivity values) shall [10 CFR 835.1102(c)]:
• undergo routine monitoring to ensure removable surface contamination levels
remain below the Appendix D values. Monitoring should be conducted in and
around the area using techniques discussed in Section 11.5.1 of this Guide; and
Section 111
• display conspicuous markings to warn individuals of the contaminated status. The
marking may consist of stencils on affected surfaces or postings established at
each access point. The marking should include the radiation warning trefoil and
the words "Caution, Fixed Contamination" and should provide radiation
protection instructions sufficient to prevent inadvertent removal of the
contamination.
Additional guidance on labeling of items having only fixed contamination is provided in
Chapter 12. Additional information on control of fixed contamination is provided in
Chapter 2 of the RCS.
11.4.3 Conduct of Radiological Work
Work in contaminated areas should be conducted in a manner that minimizes the spread
of contamination to adjacent surfaces, individuals in the area, and the workplace
atmosphere. The following controls and techniques should be included in work planning
and employee training:
• minimization of individuals and materials entering contaminated areas;
• a dedicated contaminated tool program, if justified by the extent of contaminated
area work activities;
• proven work techniques to minimize contamination spread, including techniques
to minimize the release of hot particles;
• judicious use of stop-work authority to correct radiological problems before they
escalate;
• judicious work area monitoring to detect, and decontamination to reduce,
contamination spread; and
• priority repair of leaks to minimize the spread of contamination.
Chapter 3 of the RCS provides more information on these issues.
11.4.4 Personnel and Material Decontamination
Two types of personnel contaminations can occur: skin (or personal clothing)
contamination and wound contamination. In this context, personal clothing includes work
DOE G 441.1-1C 143
5-19-08
clothing provided by the employer, but does not include protective clothing provided
solely for contamination control purposes. Potential internal contamination caused by
exposure to airborne radioactive material is discussed in Chapter 5 of this Guide,
DOE-STD-1121-2003, and Chapter 5 of the RCS.
11.4.4.0 Skin and Clothing Contamination
When individuals detect skin (or personal clothing) contamination, they should notify the
radiological control organization to ensure adequate characterization of the potential for
significant skin dose. A qualified radiological control organization representative should:
• assess the extent of the contamination;
• retain samples of the contamination as necessary to perform a detailed dose
assessment. Levels of contamination that trigger the need for dose assessments
should be established for site-specific radionuclides. These trigger levels should
not exceed 100 millirem (1 mSv) (equivalent dose to the skin); and
• initiate decontamination procedures that minimize skin abrasion and changes in
pore size.
Skin decontamination methods should be established for site-specific radionuclides.
Intrusive decontamination methods, such as tissue removal, require medical assistance.
Contaminated personal clothing should be decontaminated by laundering or other
appropriate methods, monitored, and returned to the owner or, if necessary, disposed of
as radioactive waste.
11.4.4.1 Wound Contamination
Medical treatment of injuries takes precedence over radiological considerations.
Emergency medical care should be administered immediately for injuries involving
radioactive materials in accordance with National Council on Radiation Protection and
Measurements Report Number No. 65, Management of Persons Accidentally
Contaminated with Radionuclides (NCRP 1980) and DOE-STD-1121-2003.
Section 112
11.4.4.2 Material and Area Decontamination
In general, water and steam are the preferred decontamination agents. Other cleaning
agents should be selected based upon their effectiveness, hazardous properties, amount of
waste generated, compatibility with the contaminated surface and other systems or items
that may be contacted (including protective clothing and waste handling systems), and
ease of disposal.
11.5 Contamination Monitoring
Comprehensive surveillance for contamination is the best available assurance of
compliance with the requirements of 10 CFR 835. Frequent routine and special
144 DOE G 441.1-1C
5-19-08
contamination monitoring should be performed in and around contaminated areas to
verify the levels and locations of contamination and to alert personnel to changes in
levels.
An effective contamination monitoring program includes the capability to calibrate
instruments and perform appropriate operational tests, monitor for contamination,
determine the lower detection limits both for field and laboratory instruments, and
conduct the appropriate quality control checks to assure reliable instrument performance.
11.5.0 Contamination Control Values
Appendix D of 10 CFR 835 establishes values above which contamination controls,
including posting, access controls, and radioactive material controls must be
implemented. The contamination monitoring program should be sufficient to identify the
location of surfaces having contamination at such levels. Contamination levels on
surfaces outside of contaminated areas should be maintained below the applicable
Appendix D values and as low as is reasonably achievable.
The footnotes to Appendix D of 10 CFR 835 provide guidance on appropriate means of
determining the surface contamination levels and comparing these levels against the
controlling values. Footnote 3 to Appendix D of 10 CFR 835 indicates that the total
contamination levels may be averaged over an area of one square meter. When averaging
total contamination levels over a square meter, the applicable Appendix D value shall be
considered to have been exceeded if:
• the average contamination level in the one square meter area exceeds the
applicable Appendix D value; or
• the sum of the activity in all isolated spots or particles in any 100 square
centimeter (cm2) area exceeds three times the applicable Appendix D value
(10 CFR 835, App. D, Footnote 3). In practice, this condition may be determined
by evaluating a number of 100 cm2 grids and ensuring that the contamination
level in any grid is less than three times the applicable Appendix D value.
There are two different scenarios under which combinations of radionuclides may be
present as radioactive surface contamination:
• there may be a combination of radionuclides all of which are within the same
10 CFR 835 Appendix D category (e.g., one horizontal row of the Appendix D
table, such as U-nat, U-235, U-238, and associated decay products); or
• there may be a combination of radionuclides in different 10 CFR 835 Appendix D
categories (e.g., radionuclides in more than one horizontal row of the Appendix D
table).
If a surface is contaminated with radionuclides all of which fall within the same
10 CFR 835 Appendix D category, then the contamination levels of the various
DOE G 441.1-1C 145
5-19-08
Section 113
radionuclides should be summed to determine if contamination levels in any area
monitored exceeds the applicable Appendix D value. For example, if a surface is
contaminated with both U-235 and U-238, then the contamination levels of both
radionuclides should be summed to determine whether or not the applicable Appendix D
value has been exceeded.
If a surface is contaminated with a combination of radionuclides in different 10 CFR 835
Appendix D categories, then the values provided in Appendix D of 10 CFR 835 may be
considered to be independent of one another. It is not necessary to perform a sum of the
fractions calculation to determine if the contamination levels in any area monitored
exceed the applicable Appendix D value. For example, if a surface is contaminated with
both U-235 and Sr-90, then the contamination levels of the two radionuclides may be
compared independently to the applicable Appendix D values. Although it is permissible
to do so, there is no need to sum the U-235 and Sr-90 contamination levels or their
fractions relative to the applicable Appendix D values. In practice however, it is often
more convenient to determine the sum of the contamination levels of the various
radionuclides and to compare this figure to the most conservative applicable Appendix D
value.
Footnote 5 to Appendix D of 10 CFR 835 discusses application of the listed surface
contamination values for Sr-90. DOE recognizes that Sr-90 is typically present in
equilibrium with its daughter, Y-90. Therefore, the values given for Sr-90 in Appendix D
should be applied to the total activity from the Sr-90/Y-90 contamination. If the Sr-90
contamination resulted from processes involving the separation and purification of Sr-90,
the lesser values (200 dpm/100 cm2 - removable, 1,000 dpm/100 cm2 - total) should be
applied. If the Sr-90 contamination is present as a constituent of a mixture of fission
products, the higher values should be applied (1,000 dpm/100 cm2 - removable, 5,000
dpm/100 cm2 - total).
The following application of footnote 5 in appendix D of 10CFR835 to Sr-90 combined
with mixed fission products is considered an acceptable approach for compliance with
10CFR835:
• Where the Sr-90 fraction is 50 percent or less, the mixed fission products surface
activity values apply.
• Where Sr-90 fraction is between 50 percent and 90 percent of the total activity,
surface radioactivity values should be 3000 dpm/100 cm2 or less.
• Where the Sr-90 fraction exceeds 90 percent the total activity, Sr-90 surface
radioactivity values should be applied to the material.
If contamination by a radionuclide not listed in 10 CFR 835 Appendix D, such as certain
isotopes of uranium (e.g. U-234), is suspected or verified, the actual contamination level
should be compared to the Appendix D value(s) for radionuclides most similar to the
contaminant(s) (i.e., radiological and chemical properties). Appropriate actions (e.g.,
posting, labeling, access controls) should be based on the results of these comparisons.
146 DOE G 441.1-1C
5-19-08
11.5.1 Monitoring
Individual and area monitoring shall be performed to demonstrate compliance with
10 CFR 835, document radiological conditions in the workplace, detect changes in
radiological conditions, detect the gradual buildup of radioactive materials in the
workplace, verify the effectiveness of engineering and process controls in containing
radioactive materials and identify and control potential sources of individual exposure to
radiation and/or radioactive material [10 CFR 835.401(a)]. Monitoring frequencies
should be based on potential and actual radiological conditions, probability of change in
conditions, and area occupancy factors. The contamination monitoring program should
incorporate the following features:
Section 114
• scheduled routine monitoring for removable contamination and, where feasible,
fixed contamination. Schedules should be adjusted to reflect changes in
conditions, activities, and previous results;
• special monitoring as necessary to accommodate planned events, such as
maintenance and repairs, barrier breach or leakage, material movement, and
unplanned events such as spills;
• sample analysis and monitoring using instruments and techniques capable of
detecting contamination below the values specified in Appendix D of
10 CFR 835. To provide for early warning of changes, a sample of smears taken
from areas surrounding contaminated areas should be analyzed for contamination
at levels below the Appendix D values;
• documentation of survey results;
• timely documented review of results for trends and changes and the need for
further action, such as decontamination, posting, changes in monitoring
frequency, and access controls; and
• provision of results for use by individuals planning work in or entering the area.
Monitoring for removable contamination should be conducted using conventional smear
techniques for quantitative analyses and, where practicable, large-area smears for
qualitative analyses. The use of large-area smears, adhesive pads or adhesive rollers is
also helpful in identifying hot particles. Direct frisking is necessary for detecting fixed
contamination; however, the application of direct frisking may be limited by such items
as: background radiation levels, frisking surface characteristics (smooth/rough, wet/dry),
frisking detector capabilities, frisking speed and distance, and type and energy of
radiation being detected. Monitoring techniques should be developed and documented to
ensure that the collected data are representative of the entire surface, with special
attention paid to likely points for collection of contamination, such as leakage points,
rough surface areas, areas that are infrequently cleaned, current work areas, and high
traffic areas.
DOE G 441.1-1C 147
5-19-08
Conventional dry smear monitoring techniques may prove to be ineffective in the
detection of tritium contamination. If tritium contamination is likely, monitoring should
be performed using wet smears or direct frisking techniques or a combination of these
methods. The monitoring method should be selected with due consideration of the
characteristics of the radiation emitted by tritium. DOE-HDBK-1129-2007 provides
guidance on monitoring for tritiated water and tritium gas (DOE 2007d). DOE
DOE-HDBK-1184-2004, RADIOLOGICAL CONTROL PROGRAMS FOR SPECIAL
TRITIUM COMPOUNDS (DOE 2004d), provides guidance for radiological controls,
including monitoring, for special tritium compounds.
Under certain conditions, radioactive contaminants may tend to penetrate the
contaminated surface and then return to the surface over an extended period of time.
This phenomenon is often encountered when dealing with tritium contamination
(off-gassing) and when handling items that are stored or used under water (leaching),
such as high level waste storage and shipping casks. When such conditions are likely,
enhanced contamination monitoring methods that are capable of detecting changes in
contamination levels as a result of leaching or off-gassing should be used.
Section 115
Because of difficulties in implementing conventional removable contamination
monitoring techniques (e.g., smear surveys), the presence of radioactive contamination
in or on soil or other surfaces contaminated with granular solids may present significant
challenges to the contamination monitoring program. Although the measurement of
contamination levels in the granular solid (on a quantity of radioactive material per
weight or volume basis) may be relatively straightforward, it may be difficult to
compare the results of such measurements to the 10 CFR 835 Appendix D values,
which are provided in units of contamination levels per unit area. Such comparisons are
necessary to ensure compliance with the 10 CFR 835 requirements for posting and area
and material control. DOE recognizes the difficulties associated with such measures. To
ensure compliance, an assessment should be performed to determine the likelihood that
radioactive contamination may be dispersed from the surface in question to surrounding
areas or to items or individuals who may come in contact with the surface. The
assessment may include a review of the operating history to determine whether
significant contamination dispersion has occurred in the past, calculations based on
realistic dispersion scenarios, performance of tests to determine the magnitude of
contamination dispersion under actual operating conditions, or other technically
defensible measures. If the results of the assessment indicate that contamination at
levels exceeding the 10 CFR 835 Appendix D values is likely to be dispersed from the
contaminated surface to surrounding or contacting surfaces, then the surface in question
should be considered contaminated at levels exceeding the Appendix D values. If the
surface in question is considered contaminated at levels exceeding the Appendix D
values appropriate protective measures shall be implemented [10 CFR 835.1001(a)].
See the hierarchy of controls discussion in the introduction to Chapter 11.0.
10 CFR 835.401(b) requires that instruments and equipment used for monitoring be
appropriate for the types, levels, and energies of the radiation(s) encountered. The
148 DOE G 441.1-1C
5-19-08
effectiveness of the contamination monitoring techniques discussed in this chapter may
be limited due to the physical conditions and specific characteristics (chemical and
radiological) of radionuclides present in some DOE facilities. For example, common
frisking and smear counting techniques and instruments may not be effective in
detecting certain low-energy radiations. Detailed technical guidance for performing
monitoring under these conditions is outside the scope of this Guide. Monitoring under
these conditions should be conducted in accordance with applicable DOE Technical
Standards and other documents, including those referenced in Chapter 11 of this Guide.
Other scientific standards (e.g., ANSI or Health Physics Society Standards or
International Commission on Radiological Protection (ICRP) or National Council on
Radiation Protection and Measurement (NCRP) publications) should also be
considered.
Additional information regarding requirements for instruments and documentation is
provided in Chapters 9 and 13 of this Guide, and in Chapters 5 and 7 of the RCS.
11.5.2 Control of Material and Equipment
Section 116
Release of material and equipment from contaminated areas presents special challenges.
Many items have surfaces that are inaccessible, making adequate monitoring of surface
contamination difficult. Monitoring of large items and vehicles can be time consuming
and difficult in inclement weather. For these reasons, to the maximum extent practical,
materials and equipment that enter contaminated areas should be retained there.
Except as noted below, any material and equipment that enters contaminated areas shall
be retained there if [10 CFR 835.1101(a)]:
• monitoring of accessible surfaces indicate the presence of removable surface
contamination at levels exceeding the removable surface contamination values
provided in Appendix D of 10 CFR 835; or
• prior use of the material and equipment indicates that removable surface
contamination levels on inaccessible surfaces are likely to exceed these levels.
Material and equipment control programs should include features that:
• provide for assessment of the likelihood of material and equipment
contamination through documentation of material and equipment location and
use, monitoring of material and equipment surfaces, or a combination of these
techniques;
• where monitoring is necessary, include monitoring for both fixed and removable
contamination;
DOE G 441.1-1C 149
5-19-08
• for materials and equipment with inaccessible surfaces that are likely to be
contaminated, require disassembly to the extent necessary to perform monitoring
on those surfaces;
• require reduction of surface contamination before release to levels that are as
low as reasonably achievable; and
• require retention of materials and equipment having contamination levels in
excess of the values provided in Appendix D of 10 CFR 835.
A prospective and retrospective assessment of the likelihood of material and equipment
contamination should consider:
• the nature of the material and equipment;
• radiological conditions in the locations in which it will be or was stored and
used;
• controls established to reduce the likelihood of contamination transfer (wrapping
or taping);
• the degree of assurance that exists regarding knowledge of the material’s and
equipment's storage and use; and
• material and equipment properties that are or were likely to preclude
contamination transfer or enhance the likelihood of contamination transfer (e.g.,
surface irregularities, installed fans and air inlets).
Under certain circumstances, materials and equipment having removable surface
contamination levels in excess of the values provided in Appendix D of 10 CFR 835
may be released to controlled areas. Materials and equipment having either removable
or total contamination levels in excess of these values may be released for movement to
another radiological area. Appropriate monitoring and controls shall be implemented
[10 CFR 835.1101(b)] and should include:
• determining the contamination levels before movement;
• wrapping or containing the material and equipment to prevent the spread of
contamination;
• applying appropriate labels to the material and equipment and postings at the
destination;
• selecting the transport path to minimize the potential for contamination spread;
and
150 DOE G 441.1-1C
5-19-08
• monitoring the transport path as necessary after movement to ensure that
contamination has not been spread
Section 117
Materials and equipment having fixed contamination (in either accessible or
inaccessible locations) in excess of the total surface radioactivity values provided in
Appendix D of 10 CFR 835 may be released for use in controlled areas. Release of such
materials and equipment shall require that [10 CFR 835.1101(c)]:
• removable contamination levels be below the values provided in Appendix D.
Contamination levels should be assessed in accordance with the guidance
provided in this Guide;
• routine monitoring be conducted. The monitoring should be adequate to ensure
that the radiological hazard resulting from the release is fully characterized and
that appropriate posting, labeling, and access control measures are implemented;
and
• the material and equipment is clearly marked or labeled. Guidance for material
and equipment labeling is provided in Chapter 12 of this Guide, and Chapter 4
of the RCS.
Written records of material and equipment release monitoring are required
[10 CFR 835.703(c)]. These records should include:
• a description of the material and equipment. Where large quantities are
involved, a simple entry such as "box of nails" or "tool box full of hand tools" is
adequate;
• monitoring date;
• identity of individual performing the monitoring;
• survey meter type and identification number; and
• monitoring results.
An acceptable approach to compliance with the record keeping requirements for release
of materials from radiological areas is to use a single record or entry that contains a
general description of a group of non-traceable items released from radiological areas.
In addition to the property description, such records must contain the information
specified by 10 CFR 835.1101(d).
The provisions of 10 CFR 835 do not apply to release of materials and equipment from
controlled areas. Material, equipment, and real property which have been documented
to comply with the criteria for release from controlled areas set forth in an authorized
limit which has been approved by a Secretarial Officer in consultation with the Chief
DOE G 441.1-1C 151
5-19-08
Health, Safety and Security Officer are expressly excluded from the provisions 10 CFR
835 [10 CFR 835.1(b)(6)]. These activities are subject to DOE standards for protection
of the environment. The release of materials and equipment from DOE control requires
following the process specified in DOE O 5400.5.
11.5.3 Portal Monitors, Laundry Monitors, and Tool Monitors
DOE encourages the use of automated monitoring devices for evaluating material and
equipment for release to controlled areas. Automated monitoring devices are typically
large gas proportional or plastic scintillation detectors arranged in a shielded counting
chamber into which objects may be placed. The monitor counts the object using a count
time sufficient to achieve the desired confidence level and compares the net count rate
from the object with a pre-determined alarm set point.
Automated monitoring devices are appropriate for monitoring of the external surfaces of
non-porous, industrially clean objects. Objects with potential internal contamination
should be surveyed using portable survey instruments. In general, automated monitoring
devices are not appropriate for releasing porous material that has been contaminated in
depth (e.g., wood, concrete) or in volume (e.g., activated material, smelted contaminated
material). However, such devices may have limited application to monitoring of items
contaminated in depth or volume by radioisotopes that emit high energy gamma
radiation.
Section 118
152 DOE G 441.1-1C
5-19-08
12.0 POSTING AND LABELING FOR RADIOLOGICAL CONTROL
The goal of a radiological hazard posting and labeling program is to identify and
effectively communicate radiological hazards to individuals, allowing them to take the
appropriate protective actions. In pursuit of this goal, a radiological posting and labeling
program works in concert with other hazard communication programs, including
programs for radiation safety training, work authorizations, written procedures, and
briefings.
10 CFR 835 requires that certain areas and items be posted or labeled to control
personnel exposure to radioactive material and ionizing radiation and to prevent the
spread of contamination. 10 CFR 835 also provides exceptions from the posting and
labeling requirements under certain circumstances; these exceptions apply to posting or
labeling requirements only. They do not apply to entry control or radiation safety training
requirements.
12.1 Implementation Guidance
This chapter discusses the regulatory requirements for radiological hazard posting and
labeling and provides guidance for achieving compliance with those requirements.
Postings for other health and safety concerns, such as those for nuclear criticality and
industrial safety concerns should be in addition to the postings specified for radiological
control.
12.2 General
10 CFR 835 establishes specific requirements for posting of controlled areas, radioactive
material areas (RMAs), and radiological areas. Controlled areas are established to warn
individuals that they are entering areas that, because of the presence of radiological areas
and/or RMAs, are controlled for radiation protection purposes. RMAs and radiological
areas are established within the controlled area to provide warning of specific hazards
that may require individual protective action for safe entry and egress.
10 CFR 835 also establishes specific requirements for labeling of items or containers of
radioactive material exceeding specified threshold activity levels. Radioactive material
labels are used to provide warning to individuals of the presence of radioactive material,
particularly in areas in which the radiological hazard does not warrant area posting in
accordance with 10 CFR 835. Use of electronic means to label items or containers (e.g.,
bar codes) in conjunction with human readable labels may help reduce human error rates
and assist in tracking and inventory of materials.
10 CFR 835.104 requires that written procedures be developed and implemented as
necessary to ensure compliance, commensurate with the radiological hazards and
consistent with the education, training, and skills of the exposed individuals. With regard
to the radiological hazard posting and labeling program, written procedures should be
developed to address the program elements addressed in this Guide. The level of detail
provided in these procedures should be sufficient to provide assurance that the affected
DOE G 441.1-1C 153
5-19-08
individuals can implement the program in a manner that will achieve and maintain
regulatory compliance. 10 CFR 835.104 provides flexibility for a site- or facility-specific
determination of the appropriate balance between individual education, training, skills,
and specificity of the required written procedures. As an example, if responsibility for
posting radiological hazard signs is assigned to radiological control technicians (RCTs)
qualified in accordance with the RCS, then the written procedures may be relatively brief,
based upon the detailed knowledge possessed by the RCTs. Conversely, if responsibility
for posting radiological hazard signs is assigned to another work group in the facility
whose members have a less-detailed knowledge of the regulatory requirements, then
more detailed procedures should be developed and implemented, based on the cognizant
individuals’ presumably more rudimentary understanding of the specific requirements of
10 CFR 835.
Section 119
10 CFR 835.604 and 835.606 establish specific conditions under which radiological
hazard posting and radioactive material labeling are not required, generally due to the
minimal hazards present in certain areas or the implementation of other controls that are
sufficient to limit individual exposures to radiological hazards. Care should be exercised
in implementing these posting and labeling exceptions to ensure that both the specific and
general requirements of 10 CFR 835 will be met in the absence of the area postings and
material labeling. For example, 10 CFR 835.604 provides a posting exception for areas in
which the radioactive material consists solely of activated structures or installed
components. Likewise, 10 CFR 835.606 provides a labeling exception for radioactive
material having an activity less than one tenth of the 10 CFR 835 Appendix E values and
less than 0.1 Ci. See Appendix E of Chapter 16 of the Guide for a listing of values.
However, omission of postings and labels under these conditions may affect the status of
compliance with other requirements of 10 CFR 835, including the ALARA requirements
of 10 CFR 835.101 and 1001, the dose limit requirements of 10 CFR 835.207 and
835.208, and the maximum controlled area dose expectation of 10 CFR 835.602(a).
The 0.1 rem in a year dose expectation discussed in 10 CFR 835.602(a) is not a limit, but
represents DOE’s expectation for conditions within controlled areas, but outside of
radiological areas and RMAs. It does not require DOE’s operating entities to take specific
actions to prevent individuals who enter controlled areas, but who do not enter
radiological areas, from receiving more than 0.1 rem in a year. Individuals who enter the
controlled area, but do not enter radiological areas or RMAs are often, but not always,
only incidentally exposed to radiation and radioactive materials. While DOE’s
expectation is that incidentally-exposed individuals will receive less than 0.1 rem TED in
a year, 10 CFR 835 does not require specific controls to limit individual doses (other than
doses to minors and members of the public) to this level.
DOE’s operating entities are required to establish programs to limit individual dose
equivalents consistent with the dose limits established in Subpart C of 10 CFR 835 and
the ALARA process as required under 10 CFR 835.101 and 835.1001 - 835.1003.
Subparts E, F, G, J, and K of 10 CFR 835 establish requirements for individual
monitoring, entry control, area posting, radiation safety training, physical design
features, and administrative controls that support these requirements and provide
154 DOE G 441.1-1C
5-19-08
flexibility for establishing controls that are commensurate with the hazards. The
requirements are complemented by guidance provided in this Guide and the RCS.
These requirements, when implemented as required by a documented radiation
protection program approved by DOE, fully satisfy DOE’s expectations for controlling
exposure in controlled areas, radiological areas, and RMAs.
Compliance with these requirements is generally achieved through implementation of a
comprehensive program that includes engineered controls, administrative controls,
training, area posting, and material labeling. Therefore, decisions regarding omission of
area postings and radioactive material labels should consider the full impact of such
omissions and the ability of the remaining program elements to ensure continued
compliance. Such decisions should be made on the basis of management-approved
standards documented in the radiation protection program, site-specific procedures,
and/or the site-specific radiological control manual.
Section 120
12.2.0 Design
Postings for controlled areas may be selected by the contractor to avoid conflict with
local security requirements [10 CFR 835.602(b)]. To the extent practicable, controlled
area postings should use the yellow and magenta radiological hazard warning color
scheme, but the flexibility provided in 10 CFR 835.602(b) extends to the shape, color
scheme, and content of the controlled area postings.
Postings for radiological areas and radioactive material areas and labels on radioactive
items and containers of radioactive material shall include the standard radiation
warning trefoil in black or magenta imposed upon a yellow background
[10 CFR 835.601(a)]. Magenta is the preferred color for the trefoil and any lettering on
the posting. The standard radiation warning trefoil is illustrated in Appendix A of this
Guide. Unless circumstances do not permit, the standard radiation warning trefoil
should be oriented with one blade downward and centered on the vertical axis. The
standard radiation warning trefoil should be displayed as prominently as is practicable.
Lettering should not be superimposed on the standard radiation warning trefoil, ANSI
N2.1-1971(R1989), Radiation Symbol, (ANSI 1989e). The size of lettering used on the
sign should not detract from the clarity of the standard radiation warning trefoil.
The background for the entire sign or label should be yellow. The lettering and standard
radiation warning trefoil should be proportional to the size of the sign or label. The
color scheme used for radiological postings and labels should be consistent throughout
the site and should be approved by the head of the cognizant radiation protection
organization before use. The color scheme used for radiological hazard posting and
labeling should be reserved for radiological hazards communication only.
Signs and labels should be constructed of materials that can endure expected
environmental conditions without significant deterioration of color, legibility, strength,
DOE G 441.1-1C 155
5-19-08
or other physical characteristics. Although magenta is the preferred color for both the
standard radiation warning trefoil and the lettering, the magenta color tends to fade
when exposed to sunlight. Therefore, special consideration should be given to the
selection of signs for outdoor postings to ensure durability. If signs or labels will be
used under conditions that are likely to result in significant degradation, routine
surveillances should be performed as necessary to verify continued legibility. Signs and
labels should not be altered or defaced in any way to change their meaning. Inserts (on
signs containing insert slots) may be changed, as appropriate.
12.2.1 Content
In addition to the standard radiation warning trefoil discussed above, postings and
labels required by 10 CFR 835 shall include the appropriate heading (“Caution,”
“Danger,” or “Grave Danger”) and wording describing the radiological hazard
(10 CFR 835 hazard designation) (10 CFR 835.603 and 835.605).
Signs required by 10 CFR 835 may include radiological protection instructions
[10 CFR 835.601(b)]. Supplemental wording describing additional warnings or
directions should be included on the postings or labels, as appropriate. Recommended
supplemental wording on potential and actual radiological conditions and specific
controls is discussed in Chapters 2 and 4 of the RCS. 10 CFR 835 requires that each
radiological area be posted. Therefore, if more than one radiological condition exists in
an area and requires posting, each condition shall be identified (10 CFR 835.603).
Multiple radiological conditions may be posted using one of two common practices:
Section 121
• by posting each radiological condition on a separate sign with any appropriate
supplemental wording; or
• by posting all radiological conditions on one or more signs (user-changeable
signs using inserts, for example) using the most stringent heading and listing the
radiological areas in decreasing order of importance. Any supplemental
information should follow the radiological area designations.
The second method is preferred because it reduces clutter and is more efficient.
Very high radiation area postings should be established on an exclusive sign without
other radiological area designations.
In recognition of the broad range of radiological conditions encompassed by the
10 CFR 835.2(a) definitions of the terms “airborne radioactivity area,” “high
contamination area,” and “high radiation area,” 10 CFR 835.603 allows use of either
the "Caution" or "Danger" heading on the required postings. This allows the hazard in
the area to be more accurately characterized. This is also an option for radioactive
material labeling (see 10 CFR 835.605). Accordingly, the "Caution" heading should be
used for lower hazards and "Danger" for higher hazards. With respect to radioactive
156 DOE G 441.1-1C
5-19-08
material labeling, the amount, specific activity, and chemical and physical
characteristics of the radioactive material should be taken into consideration. However,
the use of only one heading for the entire range of conditions is also acceptable.
Chapter 2 of the RCS provides guidance for posting of additional areas, including:
• buffer areas surrounding radiological areas;
• areas where soil contamination is present;
• areas where underground radioactive materials are present; and
• access ports to enclosures having limited accessibility, such as glove bags and
boxes.
While posting of these areas is not required to ensure compliance with the posting
requirements of 10 CFR 835, such postings may provide an additional regulatory
margin and degree of protection to affected individuals.
12.2.2 Visibility
Signs required by 10 CFR 835 shall be clearly and conspicuously posted
[10 CFR 835.601(b)]. Each item or container of radioactive material that requires
labeling shall bear a clearly visible label (10 CFR 835.605).
When posting is required, appropriate signs should be placed intermittently along the
boundary (fences, barricades, ropes, tapes, etc.). The effect upon visibility of opening
of doors or other changes in configuration should be considered when posting
radiological hazard warning signs. At least one sign should be on each side of an area's
boundary, and a sign should be visible from any normal avenue of approach. A distance
of 40 feet (12.2 m) between signs along the area's boundary is considered acceptable.
Radiological posting and labeling should be securely affixed and located such that signs
and labels can be expected to remain in place when subjected to expected adverse
conditions and environments.
When one radiological area is completely contained within another radiological area
having similar hazards (e.g., a high contamination area inside a contamination area) or
individuals must pass through one radiological area to enter another, it is not necessary
to post the exits from the inner area to indicate entry into the outer area.
12.2.3 Conditions
Section 122
Radiological warnings are posted based upon actual or likely radiological conditions.
Actual conditions are determined through area monitoring. Likely conditions should be
identified based on professional judgment or experience regarding the probability that a
radiological condition will exist. When evaluating the likelihood of specified
DOE G 441.1-1C 157
5-19-08
conditions, normal situations as well as unique situations which can reasonably be
expected to occur should be considered.
In many operations, the likelihood that a radiological condition will exist, rather than
the actual condition, will define the boundaries and posting of a radiological area. For
example, opening a contaminated ventilation system in a non-contaminated area may
require a contamination area to be established, or opening a radiological vacuum
cleaner in a contamination area may require that an airborne radioactivity area be
established. Therefore, past monitoring data, work-specific experience, and
professional judgment should be included in the decision on the correct posting of each
area.
Radiological postings should be completed before work begins, updated periodically
when changes in radiological conditions occur or are expected, and removed as soon as
is practicable when no longer required.
Radiological posting and labeling should be used or displayed only to signify the actual
or likely radiological conditions. However, posting and labeling may also be used for
illustrative purposes in appropriate educational or informational matter. When used for
this purpose, signs and labels should be clearly marked to indicate that they are for
training use only.
12.2.4 Accessibility
Radiological areas and radioactive material areas are defined based upon area
accessibility. An area is considered to be accessible to individuals when it contains
entrance or access points of sufficient size to permit human entry, i.e., such that any
portion of the body may be exposed to the radiological hazard.
Areas with entrance or access points consisting of locked doors or other controls and
interlocks (including those specified under 10 CFR 835.502), should be considered
accessible to individuals. In contrast, areas with entrance or access points consisting of
doors or portals, such as man hole covers, that are bolted or otherwise more
permanently sealed, may be considered inaccessible, unless such doors or portals are
opened on a routine basis. Likewise, areas in which the radiological hazard is located
underground, such that significant soil excavation, drilling, natural forces, or other
forms of intrusion would be required to gain access, may be considered inaccessible. In
general, areas with entrance or access points that require the use of tools or lifting or
excavation equipment to gain access may be considered inaccessible to individuals.
However, for ALARA purposes, these entrance or access points should be marked
indicating the radiological hazard that exists, or is likely to exist, behind the entrance or
access point and a warning not to open the barrier without authorization from the
radiation protection organization. In lieu of or in addition to such markings, physical
controls (e.g., physical barriers, entry alarms) and/or administrative controls (e.g.,
procedural controls, additional training) should be implemented as necessary to prevent
158 DOE G 441.1-1C
5-19-08
Section 123
unauthorized or inadvertent entry to the area or exposure of the hazard. Once the
entrance point has been unsealed (or for underground hazards, the covering soil has
been disturbed or penetrated) such that individuals may be exposed to the radiological
hazard (whether or not such acts have been authorized), the area should be considered
to be accessible.
12.2.5 Boundaries and Barriers
Controlled areas, radioactive material areas, and radiological areas should be identified
by the use of a boundary identifier or a physical barrier and sufficient signs. The
combination of signs and boundary identifiers should be sufficient to warn approaching
individuals that they are entering an area controlled for radiation protection purposes.
Boundary identifiers may consist of ropes, chains, color-coded adhesive tape, or other
materials sufficient to delineate the boundary of the area. Because color-coded adhesive
tape applied to floors may not be highly visible and provides no impediment to entry,
its use as a boundary identifier should be limited to counter-top applications or to use in
conjunction with other boundary identifiers.
Boundary identifiers and physical barriers should be clearly visible from all directions
and various elevations to prevent inadvertent access to areas. For example, rope barriers
should be approximately 24 to 40 inches (60 to 100 cm) in height. Area monitoring
should be used to determine the adequacy of boundary placement.
Existing physical barriers, such as fences or walls, may be used as boundary identifiers
if the posting is adequate to prevent inadvertent access to the area. For example, a wall
that could be crossed by ladder could suffice as a boundary identifier, but would not
prevent an individual from entering an area; thus posting would be required.
10 CFR 835.501(b) requires that the degree of personnel entry control be
commensurate with the existing and potential radiological hazards within the area.
There may be site-specific situations where the use of boundary identifiers (ropes,
chains, fence, etc.) may not be appropriate. These might include large areas with
minimal radiological hazards. For these types of situations the time and expense of
erecting and maintaining boundary identifiers may not be warranted. Site-specific
controls such as a gate and posting on the access road, supplemented by postings at
suitable intervals around the area may be adequate to provide appropriate warning and
minimize inadvertent intrusions.
12.3 Controlled Areas
Controlled areas are established and posted to warn individuals that they are entering
areas in which radiological areas and/or RMAs exist. All radiological areas and RMAs
lie within the boundaries of controlled areas (although the boundaries may be
contiguous).
DOE G 441.1-1C 159
5-19-08
Each entrance or access point to a controlled area shall be posted if that area contains
radioactive materials or radiation fields that require posting under 10 CFR 835.603
[10 CFR 835.602(a)]. The sign should contain wording equivalent to "CONTROLLED
AREA"; however, the actual wording, color scheme, and sign may be selected by the
contractor to avoid conflict with local security requirements [10 CFR 835.602(b)]. In
the event that the boundaries of the controlled area are contiguous with those of
radiological areas or RMAs, the area should be posted with both the controlled area and
radiological area/RMA postings.
Section 124
A controlled area may incorporate one or more radiological areas and/or radioactive
material areas. Controlled area borders should not be contiguous with the site boundary.
12.4 Posting for Control of Exposure to External Radiation
10 CFR 835 establishes requirements for three areas that shall be posted to provide
warning of external radiation fields - radiation areas, high radiation areas, and very high
radiation areas [10 CFR 835.603(a-c)]. The need to post these areas is contingent upon
two factors:
• area accessibility, as discussed in Section 4.1.5 of this Guide; and
• the radiation field intensity and duration, such that an individual’s dose may
exceed the specified threshold in one hour.
The posting thresholds established in 10 CFR 835 are based on the radiation field
intensity measured at a specified distance from the radiation source or from any surface
penetrated by the radiation (30 centimeters (12 inches) for radiation and high radiation
areas and 100 cm (39 inches) for very high radiation areas). To ensure continuing
compliance with the posting requirements, a degree of conservatism should be
established in the local posting requirements. The desired degree of conservatism may
be established by:
• posting affected areas at an exposure rate lower than that specified in
10 CFR 835 (i.e., requiring area posting when an individual is likely to exceed a
specified fraction of the 10 CFR 835 posting threshold); or
• measuring the exposure rate at a distance less than that specified in 10 CFR 835;
or
• both of the above.
The degree of conservatism established in the posting regimen for external radiation
hazards should be adequate to address issues of monitoring equipment variability and
likely variations in area radiological conditions.
160 DOE G 441.1-1C
5-19-08
12.5 Posting for Control of Contamination
12.5.0 Removable and Airborne Radioactive Contamination
10 CFR 835 establishes requirements for three areas that shall be posted to provide
warning of the presence of radioactive contamination - contamination area and high
contamination area postings for removable surface contamination and airborne
radioactivity area postings for airborne contamination [10 CFR 835.603(d-f)]. The need
to post contamination areas and high contamination areas is contingent upon two factors:
• area accessibility as discussed in Section 4.1.5 of this Guide; and
• the presence of removable surface contamination at levels exceeding the specified
removable surface contamination values (1x the values provided in Appendix D
of 10 CFR 835 for contamination areas, 100 x these values for high contamination
areas).
For detailed guidance on contamination measurements and the use of the 10 CFR 835
Appendix D surface contamination values, see Chapter 11 of this Guide.
The need to post airborne radioactivity areas is contingent upon three factors:
• area accessibility, as discussed previously in this Guide;
• the concentration of airborne radioactive material in the area; and
• the extent to which individuals will be in the area during the area during a week.
Section 125
10 CFR 835 establishes two criteria requiring posting of airborne radioactivity areas. The
first criterion, based upon airborne radioactive material concentrations exceeding the
derived air concentration (DAC) value(s) provided in Appendices A and C of
10 CFR 835 is absolute. That is, if the airborne radioactive material concentration
exceeds or is likely to exceed the specified value(s), then the area shall be considered an
airborne radioactivity area [10 CFR 835.2(a), Airborne radioactivity area]. The second
criterion, based upon individual exposure to airborne radioactive material, allows
consideration of individual stay times. Under this criterion, an area shall be considered to
be an airborne radioactivity area if an individual could receive an intake exceeding 12
DAC-hours in a week (i.e., if an individual was present in the area for 40 hours during a
week and the airborne radioactive material concentration exceeded 30% of the specified
DAC value(s); 40 hours multiplied by >0.30 DAC exceeds 12 DAC-hours)
[10 CFR 835.2(a) Airborne radioactivity area]. Note that this criterion requires
consideration of individual exposures without the benefit of respiratory protective
devices, whether or not such devices are required for entry. The definition of the term
“week” provided in 10 CFR 835.2(a) does not specify a starting day. A starting day for
the week should be selected and maintained constant, to the extent practicable. It is not
necessary to track individual exposures in DAC-hours over rolling seven day periods to
DOE G 441.1-1C 161
5-19-08
ensure compliance with the airborne radioactivity area posting requirements of
10 CFR 835.603(d).
To ensure continuing compliance with the posting requirements for removable and
airborne radioactive contamination hazards, a degree of conservatism should be
established in the local posting requirements. The desired degree of conservatism may be
established by posting affected areas at surface contamination/airborne radioactivity
concentrations lower than those specified (i.e., requiring area posting at a specified
fraction of the applicable 10 CFR 835 Appendix value). The degree of conservatism
established in the posting regimen for radioactive contamination hazards should be
adequate to address issues of monitoring equipment variability, sample collection
efficiency variations, and likely variations in area radiological conditions.
12.5.1 Areas of Fixed Contamination
10 CFR 835 establishes specific requirements for areas that have total contamination
levels greater than the Appendix D values, but removable contamination levels less than
the Appendix D values. 10 CFR 835 establishes no requirements for posting of these
areas (although 10 CFR 835 does establish requirements for marking these areas, which
may be satisfied through area posting, surface stenciling, or other appropriate means);
however, it does establish requirements for control of these areas. These requirements are
discussed in Chapter 11 of this Guide.
12.6 Radioactive Material Posting
10 CFR 835 requires that certain areas in which radioactive material is used, handled, or
stored be posted as radioactive material areas. The need to post RMAs is contingent upon
two factors:
• area accessibility, as discussed in Section 12.2.4 of this Guide; and
• the presence of items or containers of radioactive material in the area in quantities
exceeding the applicable Appendix E value(s).
Section 126
The RMA posting exists as a means of supporting the 10 CFR 835.602(a) controlled area
maximum total effective dose expectation of 0.1 rem (0.001 Sv) in a year and provides an
alternative to labeling of multiple radioactive items or containers of radioactive material.
Therefore, 10 CFR 835.604 allows for the use of radioactive material labeling in lieu of
RMA posting and 10 CFR 835.606 likewise allows for the use of the RMA posting in
lieu of individual item or container labeling. The flexibility provided under these
provisions permits individual DOE activities to tailor their programs to meet specific
needs.
Under conditions commonly associated with DOE activities, determinations of the
quantities of radioactive materials in an area are not as straightforward as determinations
of radiation and contamination levels and airborne radioactive material concentrations.
The process of making accurate determinations of the quantities of radioactive materials
162 DOE G 441.1-1C
5-19-08
present in some areas may be relatively cumbersome and time-consuming relative to the
benefits obtained. Because of the relatively low hazards present in RMAs, such a
designation carries no additional regulatory burden in terms of required entry controls.
Reliable, good faith measures should be implemented to assess the quantities of
radioactive material present in all areas. Such measures may include provisions for
inventory tracking, exposure rate-to-activity, concentration-to-activity, or contamination
level-to-activity calculations, activation analyses, or other technically-justified means for
determining the activity of containers of radioactive material or radioactive items. If there
is doubt about whether or not the quantity of radioactive material in an area exceeds the
applicable Appendix E value(s), the area should be posted as a radioactive material area
to ensure compliance.
Another difficulty that may arise in identifying RMAs is in determining the location of
the RMA boundaries. While the boundaries of the radiological areas are readily identified
through the conduct of area monitoring, the boundaries of a radioactive material are more
nebulous. While it may be apparent that the quantity of radioactive material in a specified
room or enclosure does not exceed that level defining an RMA, the sum of the quantities
of radioactive material in a series of adjoining rooms or enclosures may exceed the
threshold level. Such a condition will necessarily lead to questions regarding whether or
not an RMA exists and, if so, regarding the logical RMA boundaries.
Section 127
Two acceptable approaches to defining the boundaries of RMAs are provided in this
Guide; the approach selected will be determined based predominantly on considerations
of the nature of the operations taking place, the education, training, and skills of the
affected individuals, and convenience. Under the first acceptable approach, the quantity
of radioactive material in individually identifiable rooms or enclosures may be
considered. Note that the footnote to Appendix E of 10 CFR 835 requires summing of the
fractions of all radionuclides present in the designated room or area. If there are multiple
radioactive items or containers, then the activity of each radionuclide present in all of the
items and containers should be summed, divided by the appropriate Appendix E value
and then added to the similarly determined ratios for all other radionuclides present to
determine the activity-to-threshold value ratio for the designated room or area. The
postings, if necessary, should be erected at the individual room or enclosure entry or
access point(s) or, if there is a common access point to the rooms or enclosures, then the
posting may be erected at that point. Under the second acceptable approach, the quantity
of radioactive material present in a group of rooms or enclosures may be considered
(using the sum-of-the-fractions rule as discussed above) and the postings, if necessary,
should be erected at the common entry or access points. The decision regarding the
appropriate location for the posting(s) will be based largely on considerations of
convenience (i.e., the establishment of radiological hazard postings and associated entry
controls at the common entrance point(s) may disrupt or impede the activities of
individuals who must enter the area or create the need for additional radiation safety
training for these individuals).
The use, handling, or storage of items or containers of radioactive material in outside
areas may pose special challenges in identifying areas requiring posting as RMAs,
DOE G 441.1-1C 163
5-19-08
particularly when the items or containers are spread over a wide area. These challenges
result from the absence of identifiable rooms or enclosures, thus making the identification
of the identified “area” problematic. To the extent practicable and consistent with
ALARA principles, such items or containers should be consolidated in a localized area to
facilitate activity determinations, posting, and control. Piles or areas of radioactive rubble
or granular solids, such as soil or sand, would not normally be considered “items” or
“containers.” Therefore, areas in which the radioactive material consists solely of such
piles or areas would not be subject to posting as an RMA. However, appropriate controls
may be required to ensure compliance with other requirements of 10 CFR 835, including
the ALARA requirements of 10 CFR 835.101 and 835.1001, the dose limits of
10 CFR 835.207 and 835.208, and the controlled area maximum dose expectation of
835.602(a).
12.7 Exceptions from Posting Requirements
Accessible areas may be excepted from the radiological area and radioactive material
area posting requirements for periods of <8 continuous hours duration when the area is
placed under the observation and control of individuals who are knowledgeable of and
empowered to implement required access and exposure control measures
[10 CFR 835.604(a)]. The observing/controlling individual(s) should be stationed to
provide line of sight surveillance of the area boundaries and verbal warnings. For
situations that require only simple access control measures, such as entry prevention, a
minimally-trained individual would suffice. For situations that require more complicated
access and exposure control measures, a radiological control technician should be used. A
sufficient number of individuals should be used to provide for adequate access and
exposure control.
Section 128
The following accessible areas are excepted from the radioactive material area posting
requirements [10 CFR 835.604(b)]:
• radiological areas posted in accordance with 10 CFR 835.603(a) - (f). In this case,
the radiological area posting provides adequate warning of the area hazards;
• areas in which each item or container of radioactive material is clearly and
adequately labeled in accordance with Subpart G of 10 CFR 835 such that
individuals entering the area are made aware of the hazard. In this case, the
radioactive material labels provide adequate warning of the area hazards; and
• areas in which the radioactive material of concern consists solely of structures or
installed components which have been activated (i.e., such as by being exposed to
neutron radiation or particles produced in an accelerator).
Areas containing only packages received from transportation need not be posted in
accordance with 10 CFR 835.603 until the packages are monitored in accordance with
164 DOE G 441.1-1C
5-19-08
10 CFR 835.405 [10 CFR 835.604(c)]. For ALARA purposes, the time between package
receipt and monitoring should be minimized.
Even though certain areas may be excepted from posting in accordance with the
conditions provided in 10 CFR 835, appropriate controls should be established over these
areas as necessary to limit exposures consistent with the ALARA controls required under
10 CFR 835.1001. Decisions regarding the omission of radiological hazard postings
should be made in full consideration of the information provided in Section 12.2 of this
Guide.
The exceptions discussed above apply only to radiological area and/or radioactive
material area posting requirements and do not apply to the entry control requirements
established in 10 CFR 835.501 and 10 CFR 835.502 or to the radiation safety training
requirements established in 10 CFR 835.901. Decisions regarding omission of postings
should be made in full consideration of the guidance provided in Section 12.2 of this
Guide.
12.8 Radioactive Material Labeling
12.8.0 Radioactive Material Labeling
Each item or container of radioactive material shall be labeled (10 CFR 835.605). The
label shall contain the standard radiation warning trefoil and the words "CAUTION,
RADIOACTIVE MATERIAL" or "DANGER, RADIOACTIVE MATERIAL"
(10 CFR 835.605). The label shall also provide sufficient information to permit
individuals handling or using the containers or working in the vicinity of the containers to
take precautions to avoid or minimize exposures (10 CFR 835.605).
The following information should be included on the labels, as appropriate:
• radiological hazard (e.g., radiation and/or contamination levels);
• an estimate of the quantity of radioactivity;
• radioisotope(s) and activity;
• dates monitored;
• any special handling instructions necessary to permit individuals to implement
appropriate protective measures;
• name of the individual performing the monitoring; and
• a description of the material, as appropriate.
DOE G 441.1-1C 165
5-19-08
If the item is too small to accommodate a label, then the label should be applied to the
container or storage location.
The label shall be clearly visible on the item or container (10 CFR 835.605). If a label
applied to the items will not be clearly visible, then the label should be placed on the
exterior of containers holding the radioactive material.
12.8.1 Exceptions from Labeling Requirements
Section 129
Containers and items are excepted from the radioactive material labeling requirements of
10 CFR 835.605 under any one of the following circumstances:
• the items or containers are used, handled, or stored in areas posted and controlled
in accordance with Subpart G of 10 CFR 835 and sufficient information is
provided to permit individuals to take appropriate protective actions
[10 CFR 835.606(a)(1)]. This information may be provided on or in conjunction
with the area postings, radiation safety training, written procedures, controlling
work authorization for that area, or other suitable means.
• the quantity of radioactive material is less than one tenth of the values specified in
Appendix E of 10 CFR 835 and less than 0.1 Ci [10 CFR 835.606(a)(2)]. For
containers that contain numerous items of radioactive material, the determination
of the need for labeling should be based upon the sum of the activities of the
individual items. Section 4.5 of this Guide provides guidance on determining the
activity of radioactive items and containers of radioactive material and on
determining the sum of the fractions of the activities of the items in question.
• the items or containers are packaged and labeled in accordance with Department
of Transportation regulations or corresponding DOE Orders
[10 CFR 835.606(a)(3)]. When such labels are used as an alternative to the
labeling required by 10 CFR 835, measures should be implemented to ensure that
affected individuals are familiar with the labels and the hazards and precautions
associated with the labeled materials.
• the items or containers are inaccessible or accessible only to individuals
authorized to handle or use them, or to work in the vicinity
[10 CFR 835.606(a)(4)]. In such situations, the individuals should be trained in
accordance with 10 CFR 835.901(b) and knowledgeable of the types and
quantities of radioactive material present in the area. Chapter 14 of this Guide
provides guidance on developing appropriate radiation safety training programs.
• the items or containers are installed in manufacturing or process equipment, such
as reactor components, piping, and tanks [10 CFR 835.606(a)(5)].
• the radioactive material consists solely of nuclear weapons or their components
[10 CFR 835.606(a)(6)].
166 DOE G 441.1-1C
5-19-08
Even though items and containers of radioactive material may be excepted from labeling
in accordance with the conditions provided in 10 CFR 835, appropriate controls should
be established over the storage, movement, and use of unlabeled items and containers as
necessary to limit exposures consistent with the ALARA controls required under
10 CFR 835.1001. Decisions regarding the omission of radioactive material labels should
be made in full consideration of the information provided in Section 12.2 of this Guide.
Although 10 CFR 835.606(a)(1) provides a labeling exception for radioactive material
that is used, handled, or stored in areas posted and controlled in accordance with Subpart
G of 10 CFR 835, caution should be exercised in applying this exception to ensure that
the radiological area posting or associated information will be sufficient to inform
affected individuals of the area hazards and required protective actions. For example, a
trained individual’s response to a “Contamination Area” posting (i.e., protective clothing,
personnel frisking) may not be sufficient to protect that individual from the hazards
associated with an unlabeled radioactive item or container in the area. Similarly, a trained
individual’s response to a “Radiation Area” posting may not be sufficient to protect that
individual from the hazards arising from the opening of a wrapped, but unlabeled,
contaminated item in that area. In such cases, the exception provided in
10 CFR 835.606(a)(1) requires that sufficient information be provided to permit
individuals to take appropriate protective actions. As discussed above, this information
may be provided in conjunction with the area postings, radiation safety training, written
procedures, controlling work authorizations or other suitable means.
Section 130
DOE G 441.1-1C 167 (and 168)
5-19-08
Appendix 12.A – Standard Radiation Warning Trefoil
The standard radiation warning trefoil should be proportioned as shown below (ANSI N2.1). The
trefoil color shall be either magenta or black on a yellow background [10 CFR 835.601(a)].
DOE G 441.1-1C 169
5-19-08
13.0 OCCUPATIONAL RADIATION PROTECTION RECORD-KEEPING
AND REPORTING
This Guide provides instructions for implementing a program that will meet DOE
requirements for generating, administering, and retaining occupational radiation
protection records and reports. Complete and accurate radiation protection records are
necessary to:
• provide information used to protect individuals from radiation exposure;
• evaluate the effectiveness of the radiation protection program;
• demonstrate compliance with regulations and requirements; and
• defend the radiation protection program against unwarranted litigation.
Supporting guidance useful in developing and implementing occupational radiation
protection record-keeping programs is provided in N13.6, Practice for Radiation
Exposure Records Systems (ANSI/HPS 1999) and NCRP Report No. 114, Maintaining
Radiation Protection Records (NCRP 1992). These documents should be used in concert
with this Guide and 10 CFR 835 because they may not address every DOE-specific
occupational radiation protection record-keeping requirement.
The RCS provides detailed information concerning various aspects of records
management programs, including record-keeping standards. The RCS provides detailed
technical guidance concerning employee records, radiological control procedures, area
monitoring, and instrumentation and control. The information provided by the RCS,
used in conjunction with this Guide, will assure that a records management program
will meet the record-keeping requirements and relevant DOE contractual requirements.
13.1 Implementation Guidance
This chapter describes acceptable methods for conducting a functional and effective
program for generating and administering occupational radiation protection program
records and reports. An acceptable radiation protection records program should:
• be implemented by individuals who are knowledgeable of the record-keeping
requirements. Guidance on appropriate education, training, and skills is provided
in the RCS and in Chapter 3 of this Guide;
• have documented policies and procedures for record and report generation and
administration;
• demonstrate accuracy, completeness, timely record and report generation, and
retrieval capability; and
170 DOE G 441.1-1C
5-19-08
• maintain documents that are traceable, trackable, verifiable, and retrievable, to
substantiate historical events.
Unless otherwise specified, all radiation protection program records and reports shall use
the special radiological units of curie, rad, roentgen, and rem, including their multiples
and subunits or other conventional units, such as, dpm, dpm/100 cm2 or mass units
(10 CFR 835.4). Units such as counts per minute should not be used without the
additional detailing of supplemental information (such as counting efficiencies) needed to
evaluate the units. The international system of units may be used to facilitate calculations
(e.g., Becquerel, Gray, Sievert) but final records and reports should always be provided in
the required units.
13.2 Records to be Generated and Maintained
Section 131
Required records include individual monitoring and dose, workplace monitoring and
control, and administrative records
13.2.0 Individual Monitoring and Dose Records
10 CFR 835.702(a) and (b) require maintenance of monitoring results to document doses
received by:
• all individuals monitored pursuant to 10 CFR 835.402;
• all individuals who received unplanned doses exceeding the monitoring threshold;
all individuals who receive doses as a result of planned special exposures and
authorized emergency exposures; and
• all individuals for whom monitoring was provided, but not required under
10 CFR 835.402.
Individual monitoring records shall be sufficient to evaluate compliance with the
regulatory provisions for internal and external exposures [10 CFR 835.702(c)(1)]. An
acceptable approach for meeting this requirement is for a site to maintain records of all
occupational doses received during the year for any monitored (internal or external
exposure) individual at that site. The records would include doses received at other sites
prior to being monitored at the site in question. These records shall be sufficient to
provide dose information necessary to complete mandated reports to individuals
[10 CFR 835.702(c)(2)].
10 CFR 835.702(d) requires that documentation of all occupational doses received during
the current year be obtained to assure individuals do not exceed the dose limits provided
in 10 CFR 835.202(a). A written estimate signed by the individual may be accepted if
complete records documenting previous occupational dose during the year cannot be
obtained. 10 CFR 835.702(e) requires that reasonable efforts be made to obtain complete
records of the current year’s occupational internal and external doses. An acceptable
DOE G 441.1-1C 171
5-19-08
approach to obtain such records includes making at least three written requests to each
prior employer. Doses from planned special exposures conducted in accordance with
10 CFR 835.204 and emergency exposures authorized in accordance with
10 CFR 835.1302(d) are not included when determining compliance with the
occupational dose limits.
Individual monitoring records identified with a specific individual shall be readily
available to that individual [10 CFR 835.702(f)]. Individuals should be informed as to
how they may access their records. Guidance on reports to individuals is provided in
section 13.3.0 of this Guide. See Section 13.8 for Privacy Act considerations.
Frequently, for individuals who had previously been monitored during the year, the
process of obtaining exposure records may be too time consuming to allow the individual
to commence scheduled work. In these situations, an acceptable approach would be to
obtain a written estimate of the current year dose from the individual and implement
appropriate administrative control levels for these individuals. This approach will allow
these individuals to receive occupational exposure during the time period when efforts
are being made to obtain complete records documenting previous occupational dose
during the year. Administrative control levels implemented for this situation should
consider the individuals’ current year work history and the potential magnitude of
occupational dose received (e.g., had they been involved in any radiological incidents, are
they knowledgeable of the radiological conditions in areas where they worked, do they
have any estimated exposure information from self reading dosimeters).
Section 132
For members of the public being monitored per 10 CFR 835.402 and granted access to
Controlled Areas, a written statement that they had not been monitored for, or received
exposure to, ionizing radiation in a Controlled Area during the current year would
typically be sufficient to ensure compliance with the dose limits in 10 CFR 835 subpart
C. If a member of the public were to indicate that they had been monitored for or
received exposure to ionizing radiation in a Controlled Area and could not provide
adequate documentation of any subsequent exposure, implementation of the above
guidance for occupational exposures would be an acceptable approach (i.e., a written
estimate and appropriate administrative controls).
Each individual’s dose records should be identified by the following information, as
appropriate:
• full name;
• social security number, employee or other unique identifying number;
• date of birth;
• sex;
• employment status;
172 DOE G 441.1-1C
5-19-08
• occupation code;
• facility type or building number; and
• organization code.
13.2.0.0 Internal Doses
10 CFR 835.702(c)(4) requires that individual internal dose records include the
committed effective dose, the committed equivalent dose to any organ or tissue of
concern (e.g., any organ or tissue receiving a dose approaching the threshold for required
monitoring), and the identity of the radionuclide(s). These records should also typically
include the estimated intake to facilitate future reassessments of doses [see
10 CFR 835.702(g)]; however, the estimated intake is not needed for determination of
dose from certain forms of some radionuclides, such as tritiated water vapor or elemental
tritium. In these cases, the intake need not be recorded. In cases where intakes are
detected or confirmed in a year subsequent to the year of the intake, the committed
effective dose should be attributed to the known or assumed year of the intake, and all
records and reports for that year should be amended as appropriate. Records of the results
of air monitoring when used to determine individual occupational dose shall be
documented and maintained [10 CFR 835.703(b)].
In the 2007 amendment to 10 CFR 835 DOE made a revision to allow some relief from
the need to perform a dose assessment and to record very small internal doses. Recording
of internal dose (committed effective dose or committed equivalent dose) is not required
for any result estimated to correspond to an individual receiving less than 0.01 rem (0.1
mSv) committed effective dose. The bioassay or air monitoring result used to make the
estimate shall be maintained in accordance with § 835.703(b) and the unrecorded internal
dose estimated for any individual in a year shall not exceed the applicable monitoring
threshold at § 835.402(c) [10 CFR 835.702(b)].
This relief will be most useful for internal exposure assessments where it is possible to
detect and assess doses at a small fraction of the internal dose monitoring threshold (e.g.,
tritium or certain uranium exposures). The relief most easily can be achieved through the
development and use of default values, below which no further dose assessment or
recording would be required. However, the bioassay or air monitoring data used in
making the assessment must still be maintained. This practice is consistent with
nationally accepted standards as discussed in “American National Standard for Design of
Internal Dosimetry Programs” (ANSI/HPS 2000).
Section 133
Internal dosimetry technical basis documentation should be developed and should include
technical methods, supporting evidence, and reference information used to provide the
technical foundation for the internal dosimetry program. The technical basis
documentation should be controlled and retained as a radiation protection program
record. Guidance for determining individual internal doses is provided in Chapter 5 of
this Guide.
DOE G 441.1-1C 173
5-19-08
Special radiobioassay measurements should be performed following suspected or
confirmed intakes. The extent of the investigation and the number and frequency of these
radiobioassays should be determined and documented on an individual, case-specific
basis, taking into account the potential magnitude of the intake, the effective clearance
half-time, the health of the worker, and the number of measurements needed to evaluate
the internal dose.
Additional guidance for recording and reporting internal doses and related information is
provided in Section 9, of DOE-STD-1121-2003. Record-keeping and reporting of internal
doses and related information should be in accordance with this standard.
13.2.0.1 External Doses
10 CFR 835.702(c)(3) requires that individual external dose records include the effective
dose, equivalent dose to the lens of the eye, equivalent dose to the skin and the
extremities. When the lens of the eye is not specifically monitored, the skin dose may be
used to determine regulatory compliance. When the extremities are not specifically
monitored, the dose to the skin of the whole body may be used for determination of
regulatory compliance.
When the extremities are specifically monitored, the dose should be recorded as
equivalent dose to 1) hands and arms below the elbows and, separately, 2) feet and legs
below the knees. When both left and right extremities are monitored, the higher
equivalent dose should be recorded.
When an individual is provided multiple dosimeters, the dose measured by the highest
responding dosimeter on the whole body should be assigned as the whole body dose of
record (see Chapter 6 for special considerations). When multiple dosimeters are
employed more than once during the year, dosimeter results may be summed by location
and the highest total assigned as the whole body dose of record. However, sufficient
records should exist to demonstrate that the dose to portions of the whole body between
the monitoring locations did not exceed that recorded for the monitoring location.
When personnel dosimeter measurements are not available, a dose evaluation should be
performed for that period, if necessary. These estimated or assigned doses shall be clearly
recorded and maintained as such [10 CFR 835.702(a) and (g)]. When area monitoring
results are used to estimate individual dose, the results of surveys, measurements and
calculations used to determine individual occupational exposure from external sources
shall be recorded [10 CFR 835.703(b)].
A technical basis document should be developed for the external dosimetry program to
provide (or provide reference to) the regulatory, scientific, and technical foundation of
the program. The technical basis document should be handled as a controlled document
and retained as a RPP record. Guidance to determine individual external doses is
provided in Chapter 6.
174 DOE G 441.1-1C
5-19-08
The number of fixed nuclear accident dosimeter units, their locations, the effect of
intervening shielding, and an analysis demonstrating these performance criteria should be
documented in the technical basis document.
Section 134
13.2.0.2 Summation of Internal and External Doses
10 CFR 835.702(c)(5) requires that individual dose records include the total effective
dose, for any organ or tissue assigned an internal dose during the year, the sum of the
whole body equivalent dose from external exposures and the committed equivalent dose
to that organ or tissue, and the cumulative total effective dose (see guidance regarding
lifetime occupational dose, below). When only internal or external dose has been
monitored, then the summed doses will be equivalent to the component of the dose
(internal or external) that has been monitored.
13.2.0.3 Lifetime Occupational Dose
For each radiological worker monitored in accordance with 10 CFR 835.402 [i.e., the
radiological worker’s dose is expected to exceed the monitoring threshold(s)], efforts
shall be made to obtain records of prior years’ occupational dose [10 CFR 835.702(e)].
Efforts to obtain such records should include at least three written requests to each prior
employer. If the prior employer is non-responsive or complete records cannot be obtained
for any reason, a written estimate signed by the worker may be accepted.
10 CFR 835.204(b) requires that an individual's dose from all previous planned special
exposures and all doses in excess of the occupational dose limits be determined prior to
requesting the individual to participate in a planned special exposure. For this situation,
estimates of dose from previous planned special exposures and estimates of doses in
excess of the limits are not permitted for meeting the requirements of 10 CFR 835.204(b).
The records of prior years exposure required by 10 CFR 835.204(b) need only be
obtained for radiological workers who are chosen and elect to participate in a planned
special exposure.
On the basis of available dose records and written estimates, records of each radiological
worker’s cumulative total effective dose shall be maintained [10 CFR 835.702(c)(5)(iii)]
and efforts should be made to determine the lifetime occupational dose of each
radiological worker who is monitored in accordance with 10 CFR 835.402.
The adoption of the revised dosimetric quantities and units in the 2007 amendment to 10
CFR 835 requires summation of dosimetric values from pre and post 2007 10 CFR 835
amendment. Similar to DOE’s approach to applying the rule to individuals who conduct
multiple activities involving both activities under 10 CFR 835.1(b)(1) and excluded
activities (e.g., activities involving NRC licensed activities), for the purpose of
compliance with 10 CFR 835.702(c)(5)(iii), DOE considers the following terms to be
equivalent:
DOE G 441.1-1C 175
5-19-08
Dosimetric Term as Defined by Excluded
Activity Cognizant Regulator DOE Amended Dosimetric Term
Committed effective dose equivalent
Committed effective dose
Committed dose equivalent
Committed equivalent dose
Cumulative total effective dose equivalent
Cumulative total effective dose
Deep dose equivalent
Equivalent dose to the whole body
Dose equivalent
Equivalent dose
Effective dose equivalent
Effective dose
Lens of the eye dose equivalent
Equivalent dose to the lens of the eye
Quality factor
Radiation weighting factor
Shallow dose equivalent
Equivalent dose to the skin or
Equivalent dose to any extremity
Weighting factor
Tissue weighting factor
Total effective dose equivalent
Total effective dose
Section 135
The contribution to an individual’s lifetime occupational dose since January 1, 1989,
should be recorded as CTED. DOE did not require determination of CEDE or
committed effective dose prior to January 1, 1989; consequently, annual TEDE or
TED information may not be available. While determination of CEDE or committed
effective dose for internal exposures received prior to January 1, 1989, is
recommended to improve the consistency of available information, such conversion
may not be possible due to resource or data limitations. If conversion to committed
effective dose is not possible or practical, all available dose and intake data should be
recorded.
13.2.0.4 Non-Uniform Exposure to the Skin
Non-uniform exposures to the skin (such as from non-penetrating radiation or skin
contamination) shall be recorded in the individual’s dose record and included in the
dose equivalent to the skin for the year if the area of skin exposure equals or exceeds 10
cm2 and the dose equals or exceeds 1 rem (0.01 Sv) [10 CFR 835.205(b)(1) and (2) and
176 DOE G 441.1-1C
5-19-08
10 CFR 835.702(b)]. If the dose does not exceed 1 rem, the dose may be included in the
individual’s dose records as equivalent dose to the skin, but in any case, records of the
dose assessment should be maintained. If the dose exceeds 1 rem (0.01 Sv) and the area
of the skin exposure is less than 10 cm2, the dose shall be recorded as a special entry in
the individual's dose record, but shall not be included in the equivalent dose to the skin
for the year [10 CFR 835.205(b)(3)].
If the exposure to the skin is to the hands or arms below the elbows or feet and legs
below the knees, the dose should be included in the equivalent dose to the extremity for
the year. Otherwise the dose should be recorded as equivalent dose to the skin.
13.2.0.5 Planned Special Exposures (PSEs)
The dose resulting from PSEs shall not be considered in controlling future occupational
dose to the individual under 10 CFR 835.202(a), but shall be included in the records and
reports required by 10 CFR 835 [10 CFR 835.204(f)]. Doses resulting from PSEs should
be included in the determination of the individual’s yearly doses, CTED, and lifetime
dose. For the purpose of compliance with the planned special exposure requirements in
10 CFR 835.204, DOE considers the terms as listed in the table in section 13.2.0.3 to be
equivalent.
These doses are not considered in the individual’s yearly dose when demonstrating
compliance with the dose limits in 10 CFR 835.202(a). Doses resulting from PSEs
should be recorded and treated separately, even if the dose does not exceed the value of
the dose limits provided in 10 CFR 835.202(a).
13.2.0.6 Doses Resulting from Emergency or Accidental Exposures
The dose received from an authorized emergency exposure or unplanned exposure
exceeding the applicable monitoring threshold shall be documented in each individual's
dose record [10 CFR 835.702(a)]. Doses resulting from accidents shall be included in
assessments with compliance with the dose limits provided in 10 CFR 835
[10 CFR 835.2(a), Occupational dose]. Doses resulting from authorized emergency
exposures shall not be considered in assessments of compliance with the regulatory
dose limits and should not be considered in controlling the affected individual’s future
routine occupational exposure under 10 CFR 835.202(a).
13.2.0.7 Records of Embryo/Fetus Dose and Declared Pregnant Workers
Section 136
Records pertaining to the embryo/fetus and the declared pregnant worker shall include:
• the equivalent dose to the embryo/fetus of a declared pregnant worker
[10 CFR 835.702(c)(6)];
• the written declarations of pregnancy for the individual, including estimated
conception date [10 CFR 835.704(d)]; and
DOE G 441.1-1C 177
5-19-08
• the written revocations of declarations of pregnancy for the individual, if any
[10 CFR 835.704(d)].
Other records that should be maintained include:
• any work restrictions imposed;
• any counseling performed;
• monitoring performed (e.g., dosimeter placement, bioassay frequency,
supporting workplace monitoring); and
• records of reports provided.
Guidance for determining dose to the embryo/fetus may be found in Chapter 8 of this
Guide.
13.2.0.8 Individual Monitoring Program Records
Data that are necessary to support or recalculate doses at a later date shall be retained
[10 CFR 835.702(g)]. Records that should be retained include the following:
• the monitoring program technical basis documents and any changes;
• decisions to include or exclude program participants and the monitoring results
(individual and workplace) supporting these decisions;
• calculations of dose based on workplace monitoring data, when performed;
• sample collection dates, times, volumes, analysis results, and dose assessment;
• models used (i.e., individual specific parameters versus Reference Man, etc.);
• records of program accreditation, exceptions from accreditation, or other
approvals;
• contractual arrangements for contractor dosimetry services;
• program cross-checks;
• instrument capability, calibration and functional tests;
• workplace monitoring results;
• results of trend analyses;
178 DOE G 441.1-1C
5-19-08
• monitoring device issue, return, readings, dose assessment, inter-device
agreement, and investigations;
• dosimeter relocation or multi-badge issue, as appropriate;
• field correction factors used;
• calculations of external dose from airborne radionuclides and surface, skin, or
clothing contamination; and
• employee radiological safety concerns that have been formally investigated.
13.2.0.9 Equipment Capabilities
The capabilities of radiation monitoring instruments, including individually worn
dosimeters, should be documented. Recorded information should include the
identification, description, and functional specifications and the results and date of any
acceptance or performance tests that are performed to demonstrate equipment
capabilities with regard to sensitivity, range, and energy dependence (ANSI/HPS
N13.6). Additionally, records of computer program capabilities, limitations, and
validation and verification should be maintained.
13.2.1 Monitoring and Workplace Records
This chapter applies to the records that may be required to establish the conditions
under which individuals were exposed to radiation or radioactive material. These
records supplement the individual dose records that are based on individual monitoring.
In some cases, workplace records provide the only means for estimating individual
doses. These records are also helpful in assessing the overall quality and effectiveness
of the radiation protection program. ANSI/HPS N13.49-2001, Performance and
Documentation of Radiological Surveys, provides guidance on documentation of
radiological surveys (ANSI/HPS 2001b). The following information shall be
documented and maintained:
Section 137
• results of monitoring for radiation and radioactive material as required by
Subparts E and L of 10 CFR 835 [except for that monitoring required by
10 CFR 835.1102(d)] [10 CFR 835.703(a)];
• results of monitoring used to determine individual occupational dose from
external and internal sources [10 CFR 835.703(b)];
• results of monitoring for the release and control of material and equipment as
required by 10 CFR 835.1101 [10 CFR 835.703(c)]; and
• results of maintenance and calibration performed on instruments and equipment
as required by 10 CFR 835.401(b) [10 CFR 835.703(d)].
DOE G 441.1-1C 179
5-19-08
13.2.1.0 Radiation Safety Analysis and Evaluation Records
Reports of initial evaluations and periodic re-evaluations of the long-term radiation
protection aspects of a work area, equipment, or specific location should be retained.
These evaluations may be used to supplement the monitoring that is required for transient
conditions. The details and content of the evaluation reports depend upon the purpose of
the report, the nature of the operation, and the associated potential hazards. The
evaluation report should include or make reference to:
• descriptions of the facility, equipment, and nature of the operation, including
modifications to any facilities, equipment or operations;
• design criteria for systems, components, and structures;
• identification of potential hazards, including the types and magnitude of the
sources of radiation allowed in the facility, and the nature and magnitude of those
found during the review;
• training and experience requirements for individuals employed in the operation;
• probability of occurrence and predicted consequences of hazards expressed in
quantitative terms where feasible;
• engineered controls and administrative controls provided to prevent or mitigate
potential accidents;
• the scope of the periodic surveillance program and the radiation instrumentation
required;
• the appropriate emergency actions to be taken in the event of accidents;
• operational limitations; and
• identification of the individual(s) who made the evaluation.
13.2.1.1 Work Authorizations
Written authorizations shall be required to control entry into and perform work within
radiological areas [10 CFR 835.501(d)]. Records of these authorizations shall be
maintained [10 CFR 835.701(a)] and should include the information provided in Chapter
3, Part 2 of the RCS pertaining to preparation of RWPs. The RCS also provides guidance
regarding the preparation and use of written work authorizations, such as RWPs and
technical work documents. The supporting records, such as monitoring records used to
prepare work authorizations, should be linked so that reference can be made to the data
when required.
180 DOE G 441.1-1C
5-19-08
13.2.1.2 Area and Material/Equipment Monitoring Records
Results of area and material/equipment monitoring activities should be recorded on
appropriate standard forms (to the extent practicable) and include the following common
elements:
• date, time, and purpose of the monitoring activity;
• general and specific location monitored;
• name and signature of the individual performing the monitoring;
• pertinent information needed to interpret the monitoring results;
• reference to a specific work authorization if the monitoring is performed to
support the authorization;
• model and serial number of the instrument (locations of fixed instruments may be
used as identifiers where the model and serial numbers are not available).
Section 138
The value of some types of area monitoring is enhanced by the use of sketches of
building, room, or equipment layouts to clearly define the areas monitored and results
observed. Monitoring of certain items however, may be adequately documented by
simply describing the item and its radiological status. Additional records that should be
maintained include:
• the technical bases for assumptions on which the monitoring program is based,
including radionuclide inventories, system functions, specific activities involving
radioactive materials, and air flow studies;
• records of alarms and alarm responses;
• placement of fixed dosimeters and nuclear accident dosimeters;
• results of samples, including location, time, occupancy, volume, radionuclides,
concentrations, counting equipment data, etc.;
• field analysis and follow-up analysis results;
• pertinent facility conditions when monitoring is performed;
• corrective actions resulting from performance of monitoring;
• personnel and area decontamination records; and
DOE G 441.1-1C 181
5-19-08
• times and dates as necessary to assess compliance with time sensitive
requirements, such as receipt of material from radioactive material transportation.
Many facilities employ area monitoring instrumentation that records on charts the
radiation levels in work locations. The record on the chart should include, or be directly
linked to, the information described in ANSI/HPS N13.6.
See Chapter 7, Part 5 of the RCS for additional guidance concerning radiation and
contamination monitoring records.
13.2.1.3 Airborne Radioactivity Monitoring Records
In addition to the guidance provided in section 4.1.2.3, the results of monitoring for
airborne radioactivity shall be documented and maintained [10 CFR 835.703(a)] and
should include:
• measured airborne radioactivity concentrations in general areas and breathing
zones;
• supporting parameters, including collection efficiency, flow rate, duration of
sampling, correction factors, and filter medium;
• individual DAC-hour calculations, when performed; and
• linkage of air sample results to individuals in the area, when monitoring results
will be used for individual dose assessment or exposure control.
Airborne monitoring program records should include:
• the technical basis for alarm set points for real-time monitors;
• the technical basis for air sampling and real-time air monitoring equipment
selection, placement, and operation; and
• any adjustments to DACs.
When air monitors with chart recorders are used, the following additional information
should be recorded on the chart or be directly linked to the chart:
• type of instrument, e.g., fixed filter or moving tape;
• tape and chart speed;
• identity of scale or range of operation; and
• specific calibration and relationship between the chart divisions and the
concentration of the airborne radioactive material depending on the tape speed
and flow rate of a moving filter unit or the flow rate of a fixed filter unit.
182 DOE G 441.1-1C
5-19-08
13.2.1.4 Records of Releases of Materials and Equipment from Radiological Areas
Records of monitoring for the release and control of material and equipment as required
by 10 CFR 835.1101 shall be documented and maintained [10 CFR 835.703(c)]. These
records should contain the following:
• description of the material or equipment;
• date on which the material or equipment was monitored;
• type and identification number of the survey instrument used;
Section 139
• results of the monitoring; and
• identification of the individual(s) who performed the monitoring.
When the material to be released consists of many small or identical items, then the
material may be described in a general manner (e.g., “box of tools” or “pallet of
lumber”). Large or unique items should be specifically identified by identification
number, if available.
13.2.2 Administrative Records
This section applies to the administrative records that describe various elements of the
radiation protection program.
The following records shall be maintained:
• training records, as necessary, to demonstrate compliance with 10 CFR 835.901
[10 CFR 835.704(a)].
• actions taken to maintain occupational exposures ALARA, including the
actions required for this purpose by 10 CFR 835.101, as well as facility design
and control actions required by Subpart K of 10 CFR 835
[10 CFR 835.704(b)];
• results of internal audits and other reviews of program content and
implementation [10 CFR 835.704(c)]; and
• changes in equipment, techniques, and procedures used for monitoring
[10 CFR 835.704(e)].
13.2.2.0 Radiation Safety Training
Records of radiation safety training are essential to show that each individual received
appropriate training. Records shall be maintained, as necessary, to demonstrate
compliance with 10 CFR 835.901 [10 CFR 835.704(a)]. These records should include
documentation of on-the-job and practical factor training as well as formal classroom
DOE G 441.1-1C 183
5-19-08
training. Training and qualifications records should be readily available to first-line
supervision and management to aid in work assignment.
Course-related items, including all revisions and dates used, should be retained include
the following:
• the course title and outline or syllabus;
• copies of handouts distributed to the attendees;
• instructor's manuals and lesson plans;
• copies or transcriptions of any video and audio training that is provided;
• attendance sheets showing dates, attendees’ names and signatures, and names of
instructors;
• documentation of job-specific training, such as radiological procedures, RWP
procedure, and special training requirements, pre-job briefings, and mockup
training;
• documentation of exceptions to training requirements and extension of
qualifications;
• on-the-job training records;
• records demonstrating the practical application of a learned skill;
• copies of any certificates issued;
• the basis for decisions to alter standard course content for specific candidates due
to prior education, experience, escort provided, etc.;
• program accreditation records;
• effectiveness evaluations and actions in response;
• training/briefings provided between full training cycles;
• basis for site/facility-specific materials;
• individual tests, or if a test bank is used, the test series number and a copy of
the bank and the series code; and
• confirmation of satisfactory completion of training.
184 DOE G 441.1-1C
5-19-08
If training or qualifications received at other locations are to be accepted in place of
training, documentation should be obtained and placed in the individuals’ training
records. Additional guidance on training records may be found in the RCS.
13.2.2.1 ALARA Records
Section 140
Actions taken to maintain occupational exposures ALARA, including actions
required by the RPP, as well as facility design and control actions shall be
documented [10 CFR 835.704(b)]. As discussed in Chapter 4, this documentation
includes formal plans and measures for applying the ALARA process to
occupational doses. This documentation should include the following, to the extent
the programmatic elements are used in the specific program:
• the ALARA committee charter, membership, and meeting minutes;
• implementation of administrative control levels;
• forms demonstrating approval to exceed administrative control levels;
• dose, intake, and personnel contamination investigation forms;
• radiological performance goals, status, and annual performance records;
• pre-job briefing, with content and attendance;
• post-job reviews, with dose estimates, and actual doses received;
• collective doses received by the total facility, by specific work groups, and
for specific high dose jobs;
• annual or special ALARA reports, e.g., dose/dosimetry trend data;
• records of ALARA design review;
• results of optimization analysis;
• work planning, including procedures and technical work documents;
• work authorizations, including RWPs;
• records of ALARA job/experiment review; and
• ALARA training records.
Formally documented optimization methodologies should be developed for
ALARA reviews and decisions on implementation of ALARA efforts. The degree
of formality should be commensurate with the radioactive material contamination
DOE G 441.1-1C 185
5-19-08
and dose potential. Chapter 1 of the RCS provides additional guidance on the
degree of program formality.
All documents and legal records used to demonstrate compliance with the
requirements for an ALARA program should be reviewed and approved by
supervisory or line management.
13.2.2.2 Facility Design
Records necessary to evaluate compliance with the design and control requirements
of Subpart K of 10 CFR 835 shall be maintained [10 CFR 835.701(a)]. These
records should include the following:
• the design and control considerations documenting the rationale for
selecting physical controls or administrative controls, when necessary;
• the design criteria used and technical basis for these criteria;
• the optimization methodology employed for facility design and
modifications;
• the technical basis for design objectives;
• the results of design reviews, including features that facilitate operations,
maintenance, decontamination, and decommissioning; and
• the technical basis for workplace controls used.
13.2.2.3 Entry and Access Control Records
Records necessary to evaluate compliance with 10 CFR 835.501 shall be
maintained [10 CFR 835.701(a)]. These records should include the following:
• system/device design, test criteria, and data;
• system/device failure and corrective actions;
• assessments of adequacy for actual and design conditions; and
• administrative controls used in lieu of physical controls.
13.2.2.4 Sealed Radioactive Sources
Records shall be maintained as necessary to evaluate compliance with the requirements
of 10 CFR 835.1201 and 10 CFR 835.1202 for sealed radioactive source control,
inventory, and source leak tests [10 CFR 835.704(f)].
Records that should be maintained include:
186 DOE G 441.1-1C
5-19-08
• source acquisition, monitoring, leak tests, inventories, loss;
• storage and use locations;
• investigations conducted; and
Section 141
• exceptions taken due to source inaccessibility or sources taken out of service.
See Chapter 7, Part 5 of the RCS for additional guidance concerning sealed radioactive
source leak tests and inventories records.
13.2.2.5 Radiation Protection Program, Policies and Procedures
Documentation supplementing the approved RPP should be developed and maintained to
demonstrate that an RPP can be effectively managed and administered to achieve
compliance with 10 CFR 835. This documentation should include a site radiological
control manual, detailed implementing procedures, appropriate management policy
statements, and technical basis documentation. While this documentation need not be part
of the RPP, it should be clearly linked to the compliance commitments contained in the
RPP. Records of this documentation should be recorded in accordance with ANSI/HPS
N13.6. All policies and procedures should have effective dates.
Documentation of changes made to the RPP without prior DOE approval should include
the rationale applied to such changes and should be retained for future reference and
demonstration of compliance.
Programmatic documentation should be developed to document the organizational and
administrative aspects of the RPP.
Records shall be maintained, as necessary, to demonstrate that individuals who are
responsible for the development and implementation of measures necessary to ensure
compliance with 10 CFR 835 have the appropriate education training, and skills to
execute these responsibilities [10 CFR 835.103 and 701(a)]. These records should include
records of the training provided in accordance with Chapter 6, Parts 4 and 5 of the RCS.
If the provisions of 10 CFR 835.3(e) are exercised, documentation of the schedule
deviation should be developed and include a discussion of the specific activity involved
and the reason for the schedule deviation.
Revisions to procedures, policies, or methods of evaluation used for monitoring shall be
documented [10 CFR 835.704(e)]. The original document and all approved revisions of
subject documents should also be retained.
13.2.2.6 Audits and Programmatic Reviews
Assessments of radiation protection programs by external agencies and internal groups
are valuable in determining the adequacy of the program. Records shall be maintained to
DOE G 441.1-1C 187
5-19-08
document the results of internal audits and other reviews of program content and
implementation [10 CFR 835.704(c)]. These records should include records of corrective
actions and audit procedures.
13.2.2.7 Posting and Labeling
Records necessary to evaluate compliance with the posting and labeling requirements of
10 CFR 835 shall be maintained [10 CFR 835.701(a)]. These records should include the
following:
• documentation of area postings on area monitoring records. These records need
not show the placement of each sign, but should be adequate to demonstrate that
areas are posted consistent with the radiological conditions recorded on the
monitoring record;
• variance from facility design parameters;
• documentation of compensatory measures implemented to obviate the need for
posting; and
• long term changes in postings.
13.2.2.8 Calibration, Functional Tests, and Maintenance Records
Section 142
Calibration and maintenance procedures, criteria, and schedules for dosimeters and
radiation protection instruments are important to demonstrate their dependability,
reliability, and accuracy. The results of maintenance and calibration performed on
instruments and equipment used for monitoring shall be recorded [10 CFR 835.703(d)].
These records should include equipment, sources, and fields used, results of initial (as
found) tests and post-adjustment tests, and corrective actions taken for instruments found
to be out of calibration or inoperable.
The calibration laboratory should maintain the following sets of documentation: (1) the
laboratory protocol; (2) the laboratory records; and (3) the calibration records. Historical
records should be maintained to detail any changes or revisions in procedures or
protocols.
The performance of functional tests during use of portable monitoring instruments in the
field should be appropriately documented. This may be as simple as a check-list on the
survey sheet.
13.3 Reports
Many reports are prepared for a variety of purposes by the radiation protection program.
This chapter describes the reports required by the previously cited references.
188 DOE G 441.1-1C
5-19-08
13.3.0 Reports to Individuals
Each individual monitored in accordance with 10 CFR 835.402 shall be provided an
annual report of his/her dose [10 CFR 835.801(c)]. The report shall include, at a
minimum the data required under 10 CFR 835.702(c), and the following additional
information [10 CFR 835.801(a) & (c)]:
--The DOE site or facility name;
--the name of the individual, and;
--the individual’s social security number, employee number, or other unique
identification number.
Individuals who were not monitored in accordance with 10 CFR 835.402 but who were
determined to have received an occupational dose in excess of any of the monitoring
thresholds of 10 CFR 835.402 should also be provided an annual report of his/her dose.
This report should also include the information discussed above. Radiation exposure
reports sent to individuals in accordance with 10 CFR 835 subpart I only need to include
exposure data for the dose received at that site or facility. 10 CFR 835.702(c)(5)(iii)
requires that records include cumulative total effective dose (CTED). CTED is the sum of
the total effective dose values recorded for an individual plus, for occupational exposures
received before the implementation date of the June 8, 2007 amendment to 10 CFR 835,
the cumulative total effective dose equivalent (as defined in the November 4, 1998
amendment to 10 CFR 835) values recorded for an individual, where available, for each
year occupational dose was received, beginning January 1, 1989.
DOE O 231.1A, Environment, Safety and Health Reporting (DOE 2004b), and DOE M
231.1-1A, Environment, Safety and Health Reporting Manual (DOE 2004c), provide
additional detailed information with respect to occupational dose reporting requirements.
Whenever a report concerning radiation protection matters is written about or to an
individual, a copy of the report should be placed in the individual's dose records.
13.3.0.0 Records Requested by Monitored Individuals
Detailed information on any individual's exposure shall be made available to him/her
upon request, consistent with the provisions of the Privacy Act (PA 1974)
[10 CFR 835.801(d)]. See section 13.4 of this Guide for Privacy Act considerations.
Requests for exposure information should be answered as soon as possible. At a
minimum, the response should provide the information supplied on the termination
report. Other data that may be requested by the individual should be supplied if available.
Section 143
13.3.0.1 Termination Dose Reports
10 CFR 835.801(b) requires that a termination dose report be provided only upon request
of the individual terminating employment. This requirement includes visiting scientists
and transient workers, such as technicians, and specialists who perform work at a facility
DOE G 441.1-1C 189
5-19-08
and then leave to work elsewhere. The termination dose report shall be provided to the
requesting individual as soon as data are available, but not later than 90 days after
termination. 10 CFR 835.801(b) also requires that a written estimate of the radiation dose
received by the individual based on available information shall be provided at the time of
termination, if requested. The provisions for termination dose reports and written
estimates only apply if the individual requests this information on or before the
individual’s last day of employment. If the request is made after the termination date,
then the request should be handled in accordance with 10 CFR 801(d). When a
termination dose report is provided to an individual, then an annual report to that
individual, under 10 CFR 801(c), is not necessary. Each facility's radiation protection
program should document how the request should be made and to whom the request
should be made. This topic should also be addressed in the appropriate radiological
training courses.
13.3.0.2 Reports to DOE
Reports identifying a specific individual and his or her exposure data may be required to
be sent to DOE. These reports include occurrences reported under DOE O 231.1A,
Environment, Safety and Health Reporting, of exposure of an individual to radiation
and/or radioactive material, or planned special exposures conducted in accordance with
10 CFR 835.204(e). Under 10 CFR 835.801(e), each individual specifically identified in
such reports shall be provided a report on his or her exposure data included in the report
to DOE at a time not later than the transmittal to DOE. A separate report should be
provided to each affected individual discussing the nature and content of the report to
DOE and his or her exposure data contained in the DOE report. Alternatively, a copy of
the report sent to DOE may be sent to each affected individual to satisfy this requirement.
Privacy Act (PA 1974) restrictions shall be considered since DOE report may contain
personal information concerning other affected individuals.
13.3.1 Reports of Planned Special Exposures
A written report of the conduct of a planned special exposure shall be submitted to the
cognizant Program Office and the Secretarial Officer responsible for environment, safety
and health matters (i.e., the Chief Health, Safety and Security Officer) within 30 days
after the exposure [10 CFR 835.204(e)]. This written report is required even though the
actual doses may not have exceeded the values of occupational dose limits established in
10 CFR 835.202.
The report should address, but need not be limited to:
• a description of the circumstances requiring the use of a planned special exposure;
• identification of involved individuals, including exposed individuals, supervisors,
approving management and DOE personnel;
• date(s) on which the exposure(s) occurred;
190 DOE G 441.1-1C
5-19-08
• estimated and actual personnel doses, including doses received by affected
individuals before the planned special exposure; and
• records of ALARA plans, work authorizations, briefings, approvals, and other
work documentation.
Section 144
13.4 Privacy Act Considerations
Any system of records that retrieves information concerning individuals by personal
identifiers, such as name, any identifying numbers (e.g., Social Security Number or
payroll number), symbol, or other identifying particulars assigned to the individual, is
subject to the Privacy Act. The principal records that would apply in this Guide are the
individual radiation dose records. Other records, such as program records, are subject to
the FOIA (FOIA 1986).
No information on an individual shall be revealed to anyone other than the individual,
DOE, or DOE contractor personnel who have a need to know without prior written
consent of the individual, unless authorized by the Privacy Act or for routine uses as
published periodically in the Federal Register. Records of deceased individuals are not
covered by the Privacy Act, but are subject to the FOIA.
The following subsections discuss applicable parts of the Privacy Act as implemented by
DOE through 10 CFR 1008 (DOE 1980).
13.4.0 Informing Individuals
Individuals about whom information will be collected should be informed of the authority
for collection of the information, the principal and routine uses of the information, and
the effects of not furnishing the information.
13.4.1 Identifying Individuals
10 CFR 1008.4 sets forth procedures for identifying the individual making a request for
access to, information from, or amendment of his/her records. Identification of the
individual should be established by one of the following three methods:
• if making a request by mail, a photocopy of two identifying documents bearing
his/her name and signature must be submitted, one of which should bear his/her
current home or business address and date of birth;
• if appearing in person, the individual must present either one identifying
document bearing his/her photograph and signature or two identifying documents
bearing his/her name and signature, one of which should bear his/her birth date
and current home or business address; or
• the individual can provide other proof of identity that the Privacy Act Officer
deems satisfactory in the particular circumstances.
DOE G 441.1-1C 191
5-19-08
13.4.2 Requesting Correction or Amendment of a Record
If an individual requests a correction or amendment to his/her records, the record shall be
changed or the Privacy Act Officer shall inform the requestor that the change has been
denied. The denial should include the record system manager's name and title, the reasons
for the denial, notification of the individual's right to appeal the denial, and the
individual's right to submit a statement of disagreement.
13.4.3 Responding to Requests
Every reasonable effort should be made to respond with the requested material,
correction, or amendment within 10 days. Response should be made within 20 days
unless unusual circumstances prevail. If a response cannot be made within 10 days, an
interim response should be made providing information on the status of the request and
an estimate of when the response will be made.
13.4.4 Accounting for Disclosures
An accounting of all disclosures of information, except those to DOE and DOE
contractor personnel with a need to know or those required by the FOIA, should be
maintained as prescribed by the Privacy Act.
13.5 Record – Keeping Standards
Records shall be retained until final disposition is authorized by DOE
[10 CFR 835.701(b)]. Individual dose records shall be transferred to DOE upon cessation
of activities at the site that could cause exposure to individuals [10 CFR 835.702(h)].
Section 145
General standards for maintenance and retention of radiation protection records,
including media, media conversion, corrections, retention, and retrievability, are provided
in the RCS.
192 DOE G 441.1-1C
5-19-08
14.0 RADIATION SAFETY TRAINING
While there are significant differences in the missions of various DOE and
DOE-contractor operations, and thus significant differences in the content of radiation
safety training programs necessary for adequate protection of employees, the basics of
radiation safety for DOE activities can be taught using core course material augmented
by site-specific material.
Different levels of radiation safety training are used to ensure the safe and efficient
conduct of work. Training courses, such as Radiological Worker Training (RWT) (DOE
2007e), take into account different levels of risk associated with various job functions and
duty locations. Training shall be commensurate with the level of potential radiological
hazards [10 CFR 835.901(c)].
A training program that evaluates the knowledge and skills that a worker needs for safe
job performance, in conjunction with core course material for teaching the fundamentals
of radiation safety, should be implemented to ensure that individuals can perform their
assigned duties safely and respond appropriately to both normal and abnormal situations
they may encounter.
14.1 Implementation Guidance
14.1.0 General Information
Radiation safety training shall be provided to all individuals before:
• being permitted unescorted access to controlled areas; and
• receiving occupational dose (i.e., the exposure resulted from the individual’s work
assignment) during access to controlled areas [10 CFR 835.901(a)]. This
requirement applies whether or not the individual is escorted.
10 CFR 835 requires that radiation safety training shall include certain topics (discussed
in detail in Section 14.3) to the extent appropriate to the individual's prior training, work
assignments, and degree of exposure to potential radiological hazards
[10 CFR 835.901(c)]. Radiation safety training program requirements should be
established in specific procedures that address, at a minimum, the issues discussed in this
Guide.
In addition to the radiation safety training requirements discussed in this Guide,
10 CFR 835.103 establishes requirements for the education, training, and skills of
individuals who are responsible for developing and implementing measures required to
ensure compliance with 10 CFR 835. Chapter 3 provides guidance for achieving
compliance with these requirements.
To ensure that appropriate radiation safety training is provided to all individuals entering
controlled areas, DOE has sponsored development of radiation safety training core course
DOE G 441.1-1C 193
5-19-08
material for General Employee Radiological Training (GERT) (DOE 2007f) and
Radiological Worker Training (RWT) (DOE 2007e). RWT has been developed in a
modular format to support two distinct core courses, RWT-I and RWT-II. RWT-II
includes the material provided in RWT-I, augmented by additional modules on more
complex radiation protection issues, such as high radiation area and contaminated area
entry and exit controls. Detailed guidance for use of the DOE core course material is
provided in the associated Program Management Guides.
Section 146
DOE developed and implemented the core course material to enhance the content of
radiation safety and other training programs across the DOE complex and to bring these
training programs up to a standard consistent with similar programs implemented in the
commercial nuclear industry. DOE recommends the use of the radiation safety training
core course material, updated as necessary to reflect recent changes in regulatory
requirements and other applicable standards, to satisfy the corresponding requirements of
10 CFR 835. Use of the radiation safety training core course material is no longer
mandatory; however, the core course material for GERT and RWT should be strongly
considered as a basis for developing and implementing radiation safety training
programs.
A radiation safety training program sufficient to meet the requirements of
10 CFR 835.901 should include:
• course materials from the DOE core training materials applicable to the
radiological hazards and controls associated with the specific DOE activity;
• site- and activity-specific content and instruction;
• performance demonstrations and examinations as appropriate to demonstrate
understanding of key concepts and practices; and
• an evaluation of other applicable DOE requirements.
A satisfactory training program for radiation safety should also include training
evaluations and provisions for maintaining training records. Detailed requirements and
guidance for maintenance of radiation safety training records are provided in Subpart H
of 10 CFR 835 and Chapter 13 of this Guide.
14.2 Determination of Required Training
10 CFR 835.901(a) and (b) establish requirements for distinct levels of radiation safety
training. If an individual will be permitted unescorted access to controlled areas or
receive occupational exposure to ionizing radiation during escorted or unescorted access
to controlled areas, a determination must be made regarding the appropriate level of
knowledge and the type of training to be provided. This determination should be based
on:
194 DOE G 441.1-1C
5-19-08
• the nature of the radiological hazards in area(s) to which the individual will be
granted access and the nature of the work to be performed. This determination
may be made on an individual basis, but is most commonly made in accordance
with standardized procedures on a group basis, such as work group affiliation,
level of access to certain areas, or type of work to be performed. If an individual
determination is needed to meet special needs (such as for a dignitary or
technical representative), the supervisor responsible for the individual's
activities should establish and document this information. Based upon the
information provided by the cognizant supervisor, the radiological control
organization, training organization, or other cognizant organization should
determine the appropriate level of training;
• the type and complexity of protective actions that the individual might be
expected to undertake in the areas to be entered. This should include an
assessment of both routine and emergency actions;
• a determination with regard to whether or not the individual will be under
constant escort or supervision; and
Section 147
• the individual's previous education, training, and experience in working with
radioactive materials and in the vicinity of radiological hazards. This
determination may be made by review of available training records, provision of
a challenge examination, knowledge of individual experience and capabilities,
personal documented interviews conducted by cognizant radiation protection or
training personnel, documented working agreements with the individual's
sponsoring organization (e.g., International Atomic Energy Agency or Defense
Nuclear Facilities Safety Board), or a combination of these activities.
Challenge examinations may be given based on the individual’s prior experience,
education, and/or training. The radiological control organization should determine
appropriate criteria for allowing challenge examinations. Challenge examinations
should be based on the objectives stated for the training program, and are an approved
form of proficiency testing. Challenge examinations should cover the entire applicable
core training program.
Challenge examinations should address learning objectives from each topic or subject
area of the training to ensure that workers not benefiting from classroom instruction
have the requisite knowledge. With successful completion of the challenge
examination, the student should be granted an exemption from the appropriate core
training course or lesson. DOE 5480.20A requires DOE nuclear facilities to prepare and
submit for approval procedures governing the processes used to grant exceptions from
training or qualification requirements. Such procedures should be developed to govern
radiation safety training for all DOE activities.
DOE G 441.1-1C 195
5-19-08
DOE encourages the establishment of reciprocity agreements to facilitate the
acceptance of training provided at other sites. It is particularly beneficial to implement
a practice of accepting training provided by other sites and facilities having similar
hazards, processes, and facilities. Such agreements require some assurance that the
training provided by the member sites provide a level of training acceptable to all
signatory parties. In general, completion of the applicable sections of the DOE core
course material within the past two years in accordance with the Program Management
Guides should be considered reasonable grounds for acceptance of previously
completed core training (see Section 14.6.). In addition, consideration may be given for
completion of training from other (non-DOE) nuclear facilities, formal education
applicable to radiation safety, and previous experience working in facilities with similar
hazards and controls. Whenever the full radiation safety training core course is not
provided, the justification for any omissions (i.e., identification of any previous
education, training, or experience accepted in lieu of providing radiation safety
training) should be documented.
14.3 Training Course Content
GERT provides the appropriate level of training for individuals who:
• enter controlled areas unescorted; or
• receive occupational exposure during controlled area entry (whether escorted or
not).
These are the individuals addressed in 10 CFR 835.901(a). GERT does not provide the
appropriate level of training for individuals who enter radiological areas unescorted or
for those individuals who perform unescorted duties as a radiological worker.
RWT-I provides the appropriate level of training for individuals who:
Section 148
• enter non-contaminated radiation areas (but not high or very high radiation
areas) or areas in which they are likely to receive doses exceeding 0.1 rem
(0.001 Sv) in a year (e.g., certain radioactive material areas and areas
surrounding radiological areas);
• work with sealed or fixed radioactive material that does not produce high
radiation fields (i.e., fields exceeding 0.1 rem (0.001 Sv) in an hour); or
• work with radiation producing devices that do not produce high radiation fields
(i.e., fields exceeding 0.1 rem (0.001 Sv) in an hour).
RWT-I is not appropriate for individuals who enter contaminated areas or high
radiation areas unescorted. However, RWT-I may be augmented by the specific
196 DOE G 441.1-1C
5-19-08
High/Very High Radiation Area Entry Training module to prepare RWT-I trained
individuals for safe entry into high or very high radiation areas.
RWT-II has been developed to provide the appropriate level of training for individuals
who, in addition to the above criteria:
• are expected to enter high radiation areas;
• are expected to enter contaminated areas; or
• are otherwise expected to work with unsealed quantities of radioactive
materials.
10 CFR 835 establishes provisions allowing the use of escorts in lieu of providing
radiation safety training. Guidance on implementing these provisions is provided in
Section 14.8 of this Guide.
RWT uses a modular format to allow training to be customized to be commensurate
with the hazard present in the area. This format facilitates upgrading of an individuals'
status from RWT-I to RWT-I with High/Very High Radiation Area Training or RWT-II
by simply completing the necessary additional modules.
Employment status (i.e., permanent, contract, temporary) should not be used to
determine the appropriate level of training. As stated above, the type and level of
training may be adjusted to be commensurate with the individual's level of access,
assigned duties, and type of previous training and experience.
Radiation safety training shall include the following topics, to the extent appropriate to
each individual's prior training, work assignments, and degree of exposure to potential
radiological hazards [10 CFR 835.901(c)]:
• basic radiological fundamentals and radiation protection concepts;
• risks of exposure to radiation and radioactive materials, including prenatal
radiation exposure;
• engineered controls, administrative controls, limits, policies, procedures, alarms,
and other measures implemented to control exposures to radiation and
radioactive materials, including both routine and emergency actions;
• individual rights and responsibilities as related to implementation of the
radiation protection program;
• individual responsibilities for implementing as low as is reasonably achievable
(ALARA) measures required by 10 CFR 835.101; and
DOE G 441.1-1C 197
5-19-08
• individual exposure reports that may be requested in accordance with
10 CFR 835.801.
The DOE core course material provides this type of information to the level of detail
that is broadly applicable to all DOE activities, but do not address site-specific
information that individuals may need to conduct work safely.
14.4 Facility-Specific Materials
To implement an effective radiation safety training program, the core courses should be
augmented with facility-specific information as necessary to adequately address the
course content requirements of 10 CFR 835.901(c). The following information should be
considered in developing facility-specific training materials:
Section 149
• procedures for entering and exiting the authorized areas, including use of work
authorizations;
• controls on radiation exposures, including administrative control levels and fetal
exposure control;
• measures for use of protective equipment, including protective clothing and
respiratory protective devices;
• alarms, warning signals, and response actions;
• ALARA measures implemented at the facility;
• requirements for interfacing with the radiation protection organization;
• skills required by the worker to execute his radiation safety responsibilities;
• worker responsibilities for self and coworker protection, including exercise of
stop work authority; and
• measures for requesting personal dose records and reports.
Following assessment of all of the necessary facility-specific information, the
facility-specific portion of the training courses should be developed to augment the DOE
core course material. The final radiation safety training materials should receive the
concurrence of the Radiological Control Manager or his designee.
Although a systematic approach to training is currently required only at DOE facilities
under the requirements of DOE 5480.20A, all DOE activities should, as much as
practicable, use this approach in developing specific training. Suggested learning
objectives and examples for different target audiences and types of facilities, such as
accelerators, radiation generating devices, plutonium, uranium, and tritium facilities, are
198 DOE G 441.1-1C
5-19-08
provided in the additional radiation safety courses developed by DOE. DOE encourages
use of these materials, revised as appropriate to reflect recent changes in applicable
requirements and standards, to identify learning objectives appropriate for the specific
target audiences and facilities.
(See http://www.hss.energy.gov/HealthSafety/WSHP/radiation/RST/rst.htm.)
14.5 Conduct of Radiation Safety Training
Radiation safety training should be conducted in an appropriate training facility, such as a
classroom or computer-based training facility, augmented by suitable mock-up and/or
laboratory facilities and on-the-job training and evaluation for RWT. Training media,
such as handouts, slides, and video presentations, should be appropriate to the subject
matter and the audience. Computer-based training may be used as appropriate to ensure
consistent and reliable presentation of the course materials. Chapter 6 of the RCS and the
Program Management Guides provide detailed guidance regarding instructor
qualifications and recommended performance demonstrations.
14.6 Completion of Radiation Safety Training
Due to the limited access granted to individuals who complete only GERT, examinations
are not required.
Successful completion of RWT shall be demonstrated by completion of an examination
[10 CFR 835.901(b)]. Examinations should be written, but other measures may be
implemented to accommodate those with special needs.
When measures other than written examinations are used, an evaluation should be made
to ensure that all individuals will be able to execute their responsibilities safely. For
example, individuals with reading comprehension impairments may take an oral
examination, but an evaluation should be performed to ensure that the student:
• can read and understand any radiological warning signs and labels, work
authorizations, and procedures affecting their work; or
• will always be provided the same level of assistance during area access and work
performance as was provided during the examination.
Section 150
Computer-based examinations, using automated examination composition and scoring,
may be used as appropriate. The minimum passing score for examinations, including
challenge examinations, should be established at or above 80 percent. When using
computer-based examinations, care must be taken to ensure that the testing process
provides the same degree of fidelity as class room training. Reference material should not
be allowed and the computer-based examination should not allow the trainee to pass the
examination based on trial and error. Permitting a trainee to pass a computer-based
examination by trial and error would be inconsistent with the requirement that individuals
demonstrate an acceptable baseline knowledge level of radiation protection fundamentals
DOE G 441.1-1C 199
5-19-08
and practices. Chapter 6 of the RCS and the core course Program Management Guides
provide detailed guidance for conducting examinations.
The RCS recommends use of DOE developed training material, supplemented by site-
specific training materials, be used to the extent practicable to satisfy the training
requirements of 10 CFR 835.901 and 10 CFR 835.103. DOE has continued to provide
copies of the DOE example test questions to DOE contractors and subcontractors. To
help keep some degree of confidentiality on the DOE example test questions, DOE has
marked the Radiological Control Technician Training Exam Bank as Official Use Only
and requests the contractors and subcontractors to certify that they are only using the
exam banks for conducting radiation safety training purposes.
DOE’s radiation training handbooks provide guidance on implementing a radiation safety
training program, including guidance on use of the DOE developed example test
questions. The DOE example test questions may be used as a basis for developing the
facility exam bank. However, sites should not rely solely on the use of the DOE
developed example test questions. In developing a facility exam bank, sites may
selectively choose some of the DOE example test questions as written. This should be a
small fraction of the total examination. They should also modify some of the DOE
example test questions (i.e., reorder the answers and change numerical values) and
develop facility specific exam questions for the remainder (i.e., the majority) of the
examination. If a facility decides to use some of the DOE example test questions as a
study aid (regardless of DOE’s recommendation), it is suggested that any questions
provided to the student as a study aid not be used verbatim in the final examination.
DOE recognizes that, other than asking contractors and subcontractors to keep the
example test confidential, DOE Headquarters has no mechanism to maintain the DOE
example test as a controlled document. The document that should be kept as a controlled
document is the facility exam bank.
In addition to an examination, students in RWT classes shall be required to complete
performance demonstrations commensurate with their duties [10 CFR 835.901(b)].
Performance demonstrations typically involve such activities as safely entering and
exiting simulated radiological areas, donning and removing protective clothing, and
performing whole body frisking. Sites should periodically evaluate individuals’ abilities
to perform acceptable radiological work practices (such as donning and doffing
protective clothing) including evaluation of performance demonstrations commensurate
with their duties, similar to those activities evaluated as part of their initial qualification.
Chapter 6 of the RCS and the RWT core course material provide detailed guidance for
conducting performance demonstrations.
Section 151
Proof of successful course completion, such as a certificate, wallet-sized card or access
control or other database entry, should be provided to indicate the successful completion
of DOE core radiation safety training. To be acceptable as proof of training at other DOE
activities, the proof of completion should include the:
• individual's name;
200 DOE G 441.1-1C
5-19-08
• date of training;
• modules covered; and
• name of certifying official (such as the instructor or examination evaluator).
To allow reciprocity for completion of the core courses, the proof of completion should
provide the course title (i.e., GERT, RW I, RW II) and, if the entire core course was
completed, a statement to that effect.
For sites planning frequent use of training reciprocity, DOE encourages close prior
coordination to establish inter-facility (or inter-site) working agreements that define
mutually-acceptable standards for acceptable training program implementation.
Regardless of such agreements, each site should retain the discretion to evaluate
incoming workers individually and to require challenge examinations or retraining as
necessary to ensure compliance. Consideration must still be given to the provisions for
facility-specific training discussed above.
Individuals who do not pass all required examinations and performance demonstration
requirements should not be allowed to proceed with unescorted tasks involving exposure
to radioactive materials or radiation until they have completed remedial actions.
Remedial actions for failure to pass a written examination or meet performance
demonstration requirements should include remedial instruction and re-examination,
repetition of the training program, or restriction from job duties. Because challenge
examinations are designed to provide credit toward required training, the remedial action
for failure of a challenge examination should be to deny credit for that examination
toward the required training. The choice and extent of remedial actions should be
determined based upon the extent of the knowledge or skill deficiencies demonstrated by
the individual.
14.7 Periodic Radiation Safety Training
In addition to the initial training provided before an individual is granted access to the
specified areas, radiation safety training shall be conducted at least once every 24 months
and whenever significant changes are implemented that might affect the individual
[10 CFR 835.901(e)]. This periodic training should not simply repeat the initial training,
but should review key principles, provide more detailed knowledge of the subject matter
required in 10 CFR 835.901(c), and stress new program requirements and seldom-used
knowledge and skills. Periodic radiation safety training should be conducted in
accordance with the guidance provided in Section 14.5.
Although many possible program changes may affect individual workers, the assessment
of their need for periodic radiation safety training at intervals of less than 24 months
should at least consider the factors discussed in Section 14.4 of this Guide. If the program
change is judged to be significant, then training should be completed either before the
change is implemented or the individuals should be restricted from their duties until
training has been completed.
DOE G 441.1-1C 201
5-19-08
Section 152
The requirements for periodic radiation safety training are not intended to deter cognizant
management from providing routine updates to workers on radiation safety requirements.
Updates may be necessary to alert workers to radiation protection program changes that
are judged to be non-significant and whose impact does not warrant formal training or
examinations. These updates are typically provided in the form of memoranda or posted
notices. DOE encourages the use of such communication devices.
Periodic radiation safety training for RWT shall include successful completion of an
examination [10 CFR 835.901(e)]. Examinations should be conducted in accordance with
the guidance provided in Section 14.6 of this Guide. If challenge examinations are used
to satisfy all or part of the requirements for periodic radiation safety training, those
examinations should be developed and conducted in accordance with Section 14.6.
14.8 Use of Escorts in Lieu of Training
As indicated in Section 14.2, constant escort of an individual may affect the extent of
required training. The use of constant escort may obviate the need for certain types of
training by making the escort responsible for the protection and actions of the affected
individual. This approach should only be used when:
• the individual will enter the area for a short period of time (i.e., a few hours);
• provision of an escort will provide for an adequate level of safety; and
• provision of an escort will not result in significant adverse dose effects (ALARA
considerations). This determination should be based upon consideration of the
resources (including collective dose) that must be expended to escort the
individual versus those necessary to provide the appropriate training.
Use of an escort is also helpful when an individual has completed portions of the required
training and would benefit from on-the-job experience. In these cases, a fully qualified
individual should directly oversee the trainee’s performance of tasks for which the
appropriate training, examinations, and performance demonstrations have not been
completed.
The assigned escort shall have completed the requisite training and shall ensure that
the untrained individual complies with the documented radiation protection program
[10 CFR 835.901(d)]. For instance, an individual assigned to escort an untrained
individual in a contaminated area shall have completed RWT-II or equivalent
training. In addition, the untrained individual, if occupationally exposed in a
controlled area at a DOE site or facility, shall complete at least those portions of the
training related to the risks of exposure to radiation and radioactive materials,
including prenatal radiation exposure and individual exposure reports that may be
requested [10 CFR 835.901(a)].
For individuals who are expected to remain in the controlled area for an extended period
(i.e., more than a few hours) or to make repeated entries, the full training course should
202 DOE G 441.1-1C
5-19-08
be completed, as appropriate to the individual's prior training, experience, and potential
exposure risks.
14.9 Refresher Training
The RCS recommends and provides guidance for the conduct of radiation safety refresher
training every other year when biennial radiation safety training is not required.
14.10 Other Training Programs
Section 153
In addition to the radiation safety training requirements discussed in this Guide,
10 CFR 835.103 establishes requirements for the education, training, and skills of
individuals who are responsible for developing and implementing measures required to
ensure compliance with 10 CFR 835. Chapter 3 provides guidance for achieving
compliance with these requirements.
14.11 Training Effectiveness Evaluations
Training effectiveness evaluations are quality assurance measures used to determine
whether qualified workers have retained all the required knowledge and skills and that
are applying them properly. Feedback is an important form of evaluation that encourages
improvements and upgrades to the training programs. Comments from supervisors,
instructors, and trainees should be used to enhance course effectiveness. Although other
means of evaluating training programs are currently in place (such as industry and facility
exchanges, instructor evaluations, and routine assessments), they are not addressed in this
Guide.
The effectiveness of radiation safety training should be verified in accordance with the
applicable training course program management guide. DOE has issued guidance for
evaluating the effectiveness of radiation safety training in Evaluating the Effectiveness of
Radiological Training. This document is also included as an attachment to the
DOE-developed Radiological Worker Training and General Employee Radiological
Training Handbooks. In addition, DOE 5480.20A requires that evaluations of training
and qualification programs be conducted in accordance with DOE-STD-1070-94,
GUIDELINES FOR EVALUATION OF NUCLEAR FACILITY TRAINING
PROGRAMS (DOE 1994).
DOE G 441.1-1C 203
5-19-08
15.0 SEALED RADIOACTIVE SOURCE ACCOUNTABILITY AND
CONTROL
A program to control sealed radioactive sources is necessary to prevent unplanned
exposures and loss of sources. DOE has codified a general requirement indicating that all
sealed radioactive sources (both accountable and exempt) shall be used, handled, and
stored in a manner commensurate with the hazards associated with operations involving
the sources (10 CFR 835.1201). For accountable sealed radioactive sources, specific
measures, including inventories and source leak tests, shall be implemented
(10 CFR 835.1202).
Exempt sealed radioactive sources need not be inventoried and leak tested. However,
exempt sealed radioactive sources and the individuals using them are still subject to all
other applicable requirements of 10 CFR 835 (e.g., radioactive material control, posting
and labeling, radiation safety training, etc).
If a sealed radioactive source contains more than one radionuclide, the
sum-of-the-fractions rule (i.e., ∑A1/Q1 + A2/Q2 + ... >= 1; where A is source activity and
Q is the accountability value for the radionuclide) shall be used to determine if the source
is accountable (10 CFR 835, Appendix E, Footnote 1). For radionuclides that are not
listed in Appendix E, 10 CFR 835 provides values of 10 microcuries for alpha emitters
and 100 microcuries for all other radionuclides. The values provided in Appendix E of
10 CFR 835 are not material release values and should not be used to determine the
acceptability of releasing materials from radiological controls either within or outside of
the controlled area.
10 CFR 835.3(e) establishes provisions allowing for extensions of the intervals between
mandatory sealed radioactive source inventories and source leak tests. Chapter 3 provides
guidance for implementing necessary extensions of the required intervals.
Section 154
15.1 Implementation Guidance
This chapter provides guidance for establishing and operating a sealed radioactive source
accountability and control program. Key components of a sealed radioactive source
accountability and control program should include:
• organization and responsibilities;
• receipt;
• labeling and storage;
• inventory;
• source leak testing; and
• handling and disposal.
204 DOE G 441.1-1C
5-19-08
Responsibilities of the organizational components, including line management, the
radiological control organization (hereinafter referred to as the RCO), the source
custodian, and the source user are presented.
15.2 Organization and Responsibilities
The responsibilities of the RCO for a sealed radioactive source accountability and control
program should include the following:
• establishing the program;
• maintaining records related to the accountability and control of sealed radioactive
sources;
• providing each source custodian with an inventory list of accountable sealed
radioactive sources; and
• assisting the source custodian in training source users.
Some of these responsibilities may be delegated to another contractor group, for example,
the safeguards and security group may be given the responsibility for maintaining
accountability records. Non-delegatable responsibilities of the RCO should include:
• approving procurement of all sealed radioactive sources with the source custodian
or user;
• performing receipt monitoring;
• performing source leak tests; and
• monitoring storage and use areas.
Sealed radioactive source custodians and source users are generally expected to work
directly with radioactive materials and therefore would meet the 10 CFR 835.2(a)
definition of the term “radiological worker.” Such individuals would therefore be subject
to the radiation safety training requirements of 10 CFR 835.901(b). An individual shall
be trained in accordance with 10 CFR 835.901(b) prior to performing unescorted
assignments as a radiological worker. 10 CFR 835.103 establishes additional
requirements for the education, training, and skills of those individuals who are
responsible for developing and implementing measures necessary for ensuring regulatory
compliance. That training should include site-specific source accountability and control
measures discussed in this Guide. See Chapters 3 and 14 for additional guidance.
The source custodian should notify and obtain approval of the RCO prior to:
• any significant change in the use of a sealed radioactive source;
DOE G 441.1-1C 205
5-19-08
• transfer of a sealed radioactive source to a new permanent storage location or to a
new source custodian;
• modification of a device containing a sealed radioactive source;
• disposal or off-site transfer of a sealed radioactive source; and
• any procurement or acquisition of additional sealed radioactive sources.
The source custodian should notify the RCO in the event of the loss of, or suspected or
actual damage to, any sealed radioactive source. The source custodian should ensure that
source leak tests are conducted and inventory checks are performed for accountable
sealed radioactive sources at least every 6 months. The RCO should actually perform the
source leak tests. The source custodian should maintain records of the storage and use
locations of all assigned sealed radioactive sources.
Section 155
Prior to taking possession of the sealed radioactive source, the source user should receive
authorization from the RCO and the source custodian. Source users should use, handle,
and store assigned sealed radioactive sources consistent with the training provided and in
accordance with the programmatic requirements established by the RCO.
15.3 Receipt
Prior to receipt of sealed radioactive sources, the RCO should assign the sources to the
proper source custodians. Immediately upon receipt of sealed radioactive sources, the
RCO should be notified. The packaging shall be inspected for damage and contamination
and radiation monitoring performed in accordance with 10 CFR 835.405. Monitoring
pursuant to § 835.405(b) is not required for packages transported on a DOE site which
have remained under the continuous observation and control of a DOE employee or DOE
contractor employee who is knowledgeable of and implements required exposure control
measures [10 CFR 835.405(e)]. Except for gaseous sealed radioactive sources and
tritium, a source leak test shall be performed upon receipt of all accountable sealed
radioactive sources [10 CFR 835.1202(b)]. The receipt monitoring and source leak test
should be performed by the RCO. The source leak test should be performed in
accordance with Section 15.6 of this Guide. The source custodian should be notified of
the arrival of the sealed radioactive sources to ensure that proper accountability and
controls are initiated. The sources should be placed into storage or into the device in
which they will be used. The source custodian’s and site's records should be updated to
include the new sealed radioactive sources.
When receiving radioactive material from NRC-licensed facilities, DOE activities are
required to ensure that the ensuing storage, usage, and control of the material are
consistent with the requirements of 10 CFR 835. Because of differences between DOE
and NRC requirements for radioactive material labeling and control, radioactive material
received from NRC licensees may or may not be received in a condition that is in
compliance with DOE requirements, particularly the labeling requirements found in
Subpart G of 10 CFR 835. Therefore, DOE activities should carefully assess the
206 DOE G 441.1-1C
5-19-08
radiological characteristics of any received material and implement the controls required
by 10 CFR 835. If the material is received with a label, consideration should be given to
retaining the label; and if the material will be transferred frequently between DOE-
regulated and NRC-licensed activities, consideration should be given to implementing
and maintaining the most stringent requirements applicable to ensure ongoing
compliance.
15.4 Labeling and Storage
Unless specifically excepted under 10 CFR 835.606, all sealed radioactive sources having
an activity exceeding 10% of the applicable 10 CFR 835 Appendix E values or 0.1 or
greater Ci content shall be labeled (10 CFR 835.605). Labels should be applied to all
sealed radioactive sources, regardless of the activity of the source, to minimize the
likelihood of loss or unauthorized usage. In recognition of the differing labels
permanently applied to certain sealed radioactive sources by their manufacturers, labels
applied to sealed radioactive sources may be excepted from the color specifications of
10 CFR 835.601(a) [10 CFR 835.606(b)(6)]. However, standard colors and designs
should be used to the extent practicable to foster instant recognition by affected
individuals.
Section 156
Appropriate designs for radioactive material labels applied to sealed radioactive sources
are described in Chapter 12. Labels should be applied directly to the sealed radioactive
source or, if that is not practicable, the labels should be applied to the storage containers
and devices containing sealed radioactive sources. The label should identify the
radionuclide, source activity, date of assay, model and serial number of the source and
container or device, and a method for identifying the source custodian.
In addition, labels should include the contact radiation levels, removable contamination
levels, dates monitored, and name of the individual performing the monitoring. The
label should be sufficiently durable to remain legible for the useful life of the device or
storage container and should be located in a readily visible place. Another method of
labeling makes use of electronic means such as bar codes along with human-readable
labels. These will minimize human errors and compensate for the small size of some
sources.
Ideally, all the labeling information should be on a label affixed to the source; however,
due to the extensive list of information and the small size of many sealed radioactive
sources, this is not always possible. If the source is too small to label, then either its
source container (unless it is also too small) or its radioactive material storage location
should be labeled. A method of tracing a source to its label should be implemented if the
label is affixed to the source container or radioactive material storage location.
Commercially manufactured sources should have a serial number on the source itself
which should be traceable to the serial number on the label. For sources without serial
numbers, the contractor should permanently mark the source, such that the integrity of
the source is not violated, with a unique identification, and should use the same
identification mark on the label.
DOE G 441.1-1C 207
5-19-08
If the radiation intensity around the sealed radioactive source container will change
significantly upon opening the container or changing the position of the source in the
container, that information should be provided on a label so that it is easily observable by
the operator.
The storage location should also be marked in order to ease location identification during
inventory. Storage locations, containers, and devices should be appropriate for the
specific sources, and should only be used to contain radioactive materials. Storage rooms
or cabinets selected to contain accountable sealed radioactive sources should either be
isolated from occupied areas or located in radiological areas, be of a design which would
minimize damage from fire, and be free of flammable or combustible substances. Storage
rooms or cabinets containing sealed radioactive sources should be locked, monitored
routinely, and posted.
Radiation and contamination monitoring of the sealed radioactive source storage area or
facility should be performed before its initial use and periodically thereafter. Monitoring
shall be performed whenever changes in status (e.g., receipt of a new sealed radioactive
source, modification to shielding) are made that may significantly affect radiological
conditions [10 CFR 835.401(a)(3)].
Proper storage practices should be used to limit unauthorized use of a sealed radioactive
source and to minimize the potential for sealed radioactive source rupture, excessive
personnel exposure, or loss of the sealed radioactive source.
Section 157
15.5 Inventory
Except for certain circumstances discussed below, all accountable sealed radioactive
sources shall be inventoried at intervals not to exceed six months. These inventories shall
accomplish the following:
• establish the physical location of each source;
• verify the presence and adequacy of associated postings and labels; and
• establish the adequacy of storage locations, containers, and devices
[10 CFR 835.1202(a)].
The presence and adequacy of postings and labels and adequacy of storage locations may
be assured through verification that these features have been established and maintained
consistent with the guidance provided in this Guide. Upon determination that an
accountable sealed radioactive source has been lost or is not stored, posted, and labeled
consistent with 10 CFR 835, the RCO should be notified.
Although exempt sealed radioactive sources are not required to be inventoried, steps
should be taken to prevent the loss of these sources, regardless of activity, as required by
10 CFR 835.1201. Measures should be implemented to restrict the removal of sources
208 DOE G 441.1-1C
5-19-08
from specified locations and, when sources are moved, to administratively track source
locations.
Appendices 15.A and 15.B are examples of typical accountable sealed radioactive source
accountability forms. A form similar to Appendix 15.A should be completed for each
new source. This form should cover initial receipt and registration of the source, changes
in source status (e.g., disposal, new use, failure of a leak test), custodian information, and
initial/receipt leak testing information. As changes occur in the source status or the source
custodian, applicable portions of the form should be updated as necessary. For example,
if the source is transferred, that portion of the form should be revised by the source
custodian and the updated form sent to the responsible RCO.
The site organization responsible for sealed radioactive source accountability (i.e., the
RCO or delegated organization) should maintain an individual form similar to the one in
Appendix 15.A for each accountable sealed radioactive source at each facility. Each
source custodian should also maintain a form for each accountable sealed radioactive
source under their responsibility.
A form similar to the one in Appendix 15.B should be provided to the source custodian
when inventory checks and/or leak tests are scheduled. This form should be completed
and a copy sent to the responsible RCO to update the accountability records. It is
recommended that the source custodian schedule the conduct of the periodic leak tests
for all of the sealed radioactive sources under his or her responsibility. The inventories
may be done by the source custodian or the RCO (at the time of the leak testing).
Most accountable sealed radioactive sources are used in a location near their
radioactive material storage location. Some portable survey instruments and
fixed-location detection systems have check sources with activities high enough to
classify them as accountable sealed radioactive sources. The source custodian is not
required to know the exact location of each check source affixed to a portable survey
instrument because radiological control technicians frequently carry such instruments
from facility to facility. Notifying the source custodian each time a portable survey
instrument with an accountable check source is moved is not required. Therefore, the
source custodian for check sources in portable survey instruments and fixed-location
detection systems should be an individual in the calibration facility who can perform
the inventory check and get the leak test performed.
Section 158
Similarly, notification of the RCO should not be required for the movement of any
accountable sealed radioactive source as long as it is being used according to approved
operations (e.g., according to a procedure or radiological work permit) as long as the
source will be returned to its original storage location.
15.6 Leak Testing
Except for those sources consisting solely of gaseous radioactive material or tritium,
accountable sealed radioactive sources shall undergo a source leak test upon receipt,
when damage is suspected, and at least every six months [10 CFR 835.1202(b)]. A leak
DOE G 441.1-1C 209
5-19-08
test should be performed prior to initial use of an accountable sealed radioactive source
and when any measurable contamination is detected on handling or storage equipment
(unless the contamination is known to be from another source).
The integrity of an accountable sealed radioactive source should be established by a
wipe test or other leak test method as recommended in ISO/DIS Report 9978, Radiation
Protection Sealed Radioactive Sources Leakage Test Methods (ISO 1990); ISO/TR
Report 4826, Sealed Radioactive Sources - Leak Test Methods (ISO 1979); ISO Report
1677, Sealed Radioactive Sources - General (ISO 1977); NCRP Report No. 40,
Protection Against Radiation from Brachytherapy Sources (NCRP 1972); and
ANSI/HPS N43.6-1997, Sealed Radioactive Sources, Classification (ANSI/HPS
1997b). Appendix V of NUREG-1556, Volume 11, Consolidated Guidance About
Materials Licenses (NRC 1998), provides an acceptable procedure for performing
source leak tests.
Electroplated sources should not be tested for leakage by wiping the foil directly. An
indication of leakage can be obtained by checking the storage container for
radioactivity or by checking the exhaust ports of items such as gas chromatography
devices (ICRP 1977). The integrity of an accountable sealed radioactive source
contained within a shield or device may be checked by wiping the area where
contamination is most likely to occur from a failure of source integrity. If it is necessary
to provide direct access to such a source to perform an adequate leak test, then
appropriate controls should be established in accordance with 10 CFR 835, the RCS,
and the manufacturer’s directions. Due to the high whole body or extremity doses that
can result, leak tests on high activity sources should never be performed by direct
contact. Remote handling devices or indirect monitoring techniques, such as monitoring
of exhaust ports or accessible areas likely to be contaminated by a leaking source,
should be used.
If analysis of the leak test sample (e.g., smear) indicates that the sample has removed
less than 0.005 microcurie (185 Bq) from the area wiped, then the leakage may be
considered to be less than the 10 CFR 835.1202(b) maximum leakage criterion of 0.005
microcurie (185 Bq). For indirect monitoring techniques, the presence of any detectable
removable contamination should be evaluated to determine if the source leakage is
greater than the 10 CFR 835.1202(b) maximum leakage criterion of 0.005 microcurie
(185 Bq).
An accountable sealed radioactive source is not subject to periodic source leak testing if
that source has been removed from service. However, unless leak testing is precluded
by other radiological safety considerations, these sources should be leak tested
periodically to determine the condition of the source. Such sources shall be stored in a
controlled location, subject to periodic inventory, and subject to source leak testing
prior to being returned to service [10 CFR 835.1202(c)]. Additionally, a documented
and updated accountable sealed radioactive source form similar to Appendix 15.A
should be maintained for each accountable sealed radioactive source, recording the last
known leak test.
Section 159
210 DOE G 441.1-1C
5-19-08
An accountable sealed radioactive source is not subject to periodic inventory and
source leak testing if that source is located in an area that is unsafe for human entry or
otherwise inaccessible, e.g., oxygen deficient or very high radiation areas
[10 CFR 835.1202(d)]. If a source is removed from the unsafe area or otherwise
becomes accessible, then this exception would no longer apply. This provision is not
applicable to sources that are located in instruments or other devices located in
accessible areas, nor should it be applied to sources that may be considered inaccessible
due to radiological conditions created by the presence of the source itself; leak tests
may be performed on these sources by wiping the instrument or device consistent with
the guidance provided above. If a source is determined to be inaccessible for inventory
and source leak testing, then appropriate measures should be implemented to control
access to the affected area and to monitor for the presence of contamination that may be
spread as a result of source failure (See Chapter 11). When the conditions that resulted
in the area being inaccessible have been eliminated, the required inventories and source
leak tests should be completed prior to rescinding these measures.
The source custodian should be responsible for ensuring that source leak tests of
accountable sealed radioactive sources are conducted at least every six months. If a
sealed radioactive source cannot be leak tested at the proper time, the source should be
removed from service until the leak test is performed. If a source is installed in an
inaccessible area, the device should not be used until the source has been leak tested.
A test result that reveals the presence of removable radioactivity on the non-radioactive
surfaces is an indication that the sealed radioactive source has lost its integrity. The
leaking source shall be controlled in a manner that minimizes the spread of radioactive
contamination [10 CFR 835.1202(e)]. Any sealed radioactive source that fails a leak
test should be immediately removed from service and controlled in accordance with
contamination control practices defined in 10 CFR 835. The source should be placed in
a separate container to prevent the spread of contamination. All personnel and
equipment that were in contact with the leaking source should be checked for
contamination; this includes transportation vehicles and the work site. The source
custodian, working with the RCO, should either return the leaking source to the
manufacturer or send it to other qualified personnel for repair or disposal. Refer to
Chapter 7 for additional guidance.
15.7 Handling and Disposal
Certain sealed radioactive sources may create significant localized radiation fields
under both normal and abnormal operating conditions. Receipt, storage, use, and
disposal of sealed radioactive sources should be conducted in accordance with
10 CFR 835, applicable DOE Orders, consensus standards, and the following guidance:
• For specific guidance on maintenance of records, see Chapter 13;
• For ALARA practices, see Chapter 4;
• For posting and labeling practices, see Chapter 12;
DOE G 441.1-1C 211
5-19-08
• For specific guidance regarding external dosimetry considerations, see Chapter
6; and
• For specific contamination controls that should be considered for leaking sealed
radioactive sources, see Chapter 11.
Section 160
Off-site sealed radioactive sources, including radiography sources, should not be
brought on-site by external organizations without the prior written approval of the
RCO.
Radiation protection precautions, dose reduction methods, and special dosimetry and
monitoring requirements should be specifically identified in procedures for use of
accountable sealed radioactive sources capable of generating external radiation fields in
excess of 100 millirem/hour (1 mSv/hour) at 30 cm. Radiation monitoring should be
performed during and after use of such sources to verify the adequacy of controls,
posting of immediate and adjacent areas, and return of the source to a safe condition.
Immediately upon determination of the loss of a sealed radioactive source, the user
should notify the source custodian who in turn should notify the RCO. A formal search
of all designated use locations, likely transfer paths, and possible collection points for
the source should be performed. In addition, an investigation should be conducted by
facility management to determine the root cause of the loss.
Obsolete, excess, or leaking sealed radioactive sources should be disposed of according
to RCO instructions. The source inventory requirements of 10 CFR 835 Subpart M are
still applicable while the sealed radioactive sources are awaiting disposition.
212 DOE G 441.1-1C
5-19-08
Appendix 15.A Example Individual Accountable Sealed Radioactive Source Form
Individual Accountable Sealed Radioactive Source Form
SOURCE DESCRIPTION
Source Model and Serial Number: ______________________
Electronic Label (as applicable): _______________________
Manufacturer: _____________________________________
Radionuclide(s): ___________________________________ Radiation Type: _____________________________
Chemical Formula: _________________________________ Physical Form:_______________________
Original Activity:___________________________________ Date of Original Assay: ________________
Physical Description: ___________________________________________________________________________
Radiation Reading at Reference Distance: ___________________________________________________________
SOURCE STATUS
Date of Receipt:____________________________________ Date of Update: _____________________
Status Change: Active - in use Source integrity failed New Source - Initial Entry
Lost In storage Awaiting disposal Transferred to new location
Disposed Returned to manuf. Decayed below accountability threshold
SHIPPING RECORDS (if transferred to off-site location)
Shipping Order Number: ________________________________________________________________________
Shipping Organization: _________________________________________________________________________
Individual Receiving Source: ____________________________________________________________________
SOURCE CUSTODIAN
Custodian's Name: __________________________________ Badge Number:_____________________________
Mailing Address: ___________________________________ Phone Number:_____________________________
SOURCE LOCATION
Facility: __________________________________________ Room:
Location Within Room: _____________________________
Device Model and Serial Number: ______________________
INITIAL/RECEIPT LEAK TEST
Date of Test: _______________________________________
Type of Instrument Used:_____________________________ Instrument ID Number:________________________
Surveyor's Name and Badge Number:_______________________________________________________________
Section 161
Test Results:
__________________________________________________________________________________
DOE G 441.1-1C 213
5-19-08
Appendix 15.B – Example Sealed Radioactive Source Accountability Form
Sealed Radioactive Source Accountability Form
Date:__________________ Surveyor's Name and Badge Number (Print): ______________________
Instrument Type Identification Number Date Calibrated Minimum Detectable
Activity Background (cpm)
A.
B.
C.
Source Model
&
Serial
Number
Radionuclide
&
Activity
Date of Last
Leak Test
Instrument(s)
Used Total Counts Net
Counts Net Activity
Posting /
Labeling
Check
Signature: ______________________________________
214 DOE G 441.1-1C
5-19-08
16.0 TECHNICAL TABLES FOR OCCUPATIONAL RADIATION PROTECTION
Appendix A
Derived Air Concentrations (DAC) For Controlling Radiation Exposure To Workers At
DOE Facilities
The data presented in appendix A are to be used for controlling individual internal
doses in accordance with § 835.209, identifying the need for air monitoring in
accordance with § 835.403, and identifying and posting airborne radioactivity areas in
accordance with § 835.603(d).
The DAC values are given for individual radionuclides. For known mixtures of
radionuclides, determine the sum of the ratio of the observed concentration of a
particular radionuclide and its corresponding DAC for all radionuclides in the mix-
ture. If this sum exceeds unity (1), then the DAC has been exceeded. For unknown
radionuclides, the most restrictive DAC (lowest value) for those isotopes not known
to be absent shall be used. For any single radionuclide not listed in appendix A with
decay mode other than alpha emission or spontaneous fission and with radioactive
half-life greater than two hours, the DAC value shall be 4 E−11 µCi/mL (1 Bq/m3).
For any single radionuclide not listed in appendix A that decays by alpha emission or
spontaneous fission the DAC value shall be 2 E−13 µCi/mL (8 E−03 Bq/m3).
The DACs for limiting radiation exposures through inhalation of radionuclides by
workers are listed in this appendix. The values are based on either a stochastic
(committed effective dose) dose limit of 5 rems (0.05 Sv) or a deterministic (organ or
tissue) dose limit of 50 rems (0.5 Sv) per year, whichever is more limiting.
Note: the 15 rems (0.15 Sv) dose limit for the lens of the eye does not appear as a
critical organ dose limit.
The columns in this appendix contain the following information: (1) Radionuclide;
(2) inhaled air DAC for type F (fast), type M (moderate), and type S (slow) materials
in units of µCi/mL; (3) inhaled air DAC for type F (fast), type M (moderate), and
type S (slow) materials in units of Bq/m3; (4) an indication of whether or not the DAC
for each class is controlled by the stochastic (effective dose) or deterministic (organ
or tissue) dose. The absorption types (F, M, and S) have been established to describe
the absorption type of the materials from the respiratory tract into the blood. The
range of half-times for the absorption types correspond to: Type F, 100% at 10
minutes; Type M, 10% at 10 minutes and 90% at 140 days; and Type S 0.1% at 10
minutes and 99.9% at 7000 days. The DACs are listed by radionuclide, in order of
increasing atomic mass, and are based on the assumption that the particle size
distribution of 5 micrometers AMAD is used. For situations where the particle size
distribution is known to differ significantly from 5 micrometers AMAD, appropriate
corrections may be made to both the estimated dose to workers and the DACs.
Section 162
DOE G 441.1-1C 215
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
H-3 (Water)2
2 E−05
2 E−05
2 E−05
7 E+05
7 E+05
7 E+05
St/St/St
H-3 (Elemental)2
2 E−01
2 E−01
2 E−01
9 E+9
9 E+9
9 E+9
St/St/St
STC
(Insoluble)4
1 E−05
6 E−06
2 E−06
3 E+05
2 E+05
8 E+04
St/St/St
STC (Soluble)
1 E−05
1 E−05
1 E−05
5 E+05
5 E+05
5 E+05
St/St/St
Be-7
-
1 E−05
1 E−05
-
4 E+05
4 E+05
/St/St
Be-10
-
8 E−08
2 E−08
-
3 E+03
1 E+03
/St/St
C-11(Vapor)2
-
1 E−04
-
-
6 E+06
-
/St/
C-11 (CO)2
4 E−04
4 E−04
4 E−04
1 E+07
1 E+07
1 E+07
St/St/St
C-11 (CO2)2
2 E−04
2 E−04
2 E−04
9 E+06
9 E+06
9 E+06
St/St/St
C-14(Vapor)2
-
9 E−07
-
-
3 E+04
-
/St/
C-14 (CO)2
7 E−04
7 E−04
7 E−04
2 E+07
2 E+07
2 E+07
St/St/St
C-14 (CO2)2
8 E−05
8 E−05
8 E−05
3 E+06
3 E+06
3 E+06
St/St/St
F-18
4 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Na-22
2 E−07
-
-
1 E+04
-
-
E/ /
Na-24
4 E−07
-
-
1 E+04
-
-
ET/ /
Mg-28
3 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/St/
Al-26
4 E−08
4 E−08
-
1 E+03
1 E+03
-
St/St/
Si-31
9 E−06
5 E−06
5 E−06
3 E+05
1 E+05
1 E+05
ET/St/St
Si-32
1 E−07
5 E−08
1 E−08
5 E+03
2 E+03
3 E+02
St/St/St
P-32
5 E−07
1 E−07
-
1 E+04
7 E+03
-
St/St/
P-33
4 E−06
4 E−07
-
1 E+05
1 E+04
-
St/St/
S-35 (Vapor)
-
4 E−06
-
-
1 E+05
-
/St/
S-35
7 E−06
5 E−07
-
2 E+05
1 E+04
-
St/St/
Cl-36
1 E−06
1 E−07
-
4 E+04
4 E+03
-
St/St/
Cl-38
7 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
Cl-39
2 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
216 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
K-40
1 E−07
-
-
6 E+03
-
-
St/ /
K-42
2 E−06
-
-
1 E+05
-
-
E/ /
K-43
9 E−07
-
-
3 E+04
-
-
ET/ /
K-44
8 E−06
-
-
2 E+05
-
-
ET/ /
K-45
9 E−06
-
-
3 E+05
-
-
ET/ /
Ca-41
-
2 E−06
-
-
8 E+04
-
/BS/
Ca-45
-
2 E−07
-
-
9 E+03
-
/St/
Ca-47
-
2 E−07
-
-
9 E+03
-
/St/
Sc-43
-
-
2 E−06
-
-
7 E+04
/ /ET
Sc-44m
-
-
2 E−07
-
-
1 E+04
/ /St
Sc-44
-
-
1 E−06
-
-
4 E+04
/ /ET
Sc-46
-
-
1 E−07
-
-
4 E+03
/ /St
Sc-47
-
-
7 E−07
-
-
2 E+04
/ /St
Sc-48
-
-
2 E−07
-
-
1 E+04
/ /ET
Sc-49
-
-
8 E−06
-
-
3 E+05
/ /ET
Ti-44
7 E−09
2 E−08
9 E−09
2 E+02
7 E+02
3 E+02
St/St/St
Ti-45
3 E−06
2 E−06
2 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
V-47
8 E−06
6 E−06
-
3 E+05
2 E+05
-
ET/ET/
V-48
2 E−07
2 E−07
-
9 E+03
7 E+03
-
ET/St/
V-49
1 E−05
2 E−05
-
7 E+05
9 E+05
-
BS/St/
Cr-48
2 E−06
2 E−06
2 E−06
8 E+04
8 E+04
8 E+04
ET/ET/ET
Cr-49
7 E−06
5 E−06
5 E−06
2 E+05
2 E+05
2 E+05
ET/ET/ET
Cr-51
1 E−05
1 E−05
1 E−05
6 E+05
6 E+05
5 E+05
St/St/St
Mn-51
7 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
Mn-52m
7 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
Mn-52
2 E−07
2 E−07
-
8 E+03
8 E+03
-
ET/ET/
DOE G 441.1-1C 217
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Mn-53
5 E−06
1 E−05
-
2 E+05
5 E+05
-
BS/St/
Mn-54
5 E−07
4 E−07
-
1 E+04
1 E+04
-
St/St/
Mn-56
2 E−06
2 E−06
-
9 E+04
8 E+04
-
ET/ET/
Fe–52
6 E−07
5 E−07
-
2 E+04
2 E+04
-
ET/E/
Fe-55
6 E−07
1 E−06
Section 163
-
2 E+04
6 E+04
-
St/St/
Fe-59
1 E−07
1 E−07
-
6 E+03
6 E+03
-
St/St/
Fe-60
1 E−09
4 E−09
-
6 E+01
1 E+02
-
St/St/
Co-55
-
5 E−07
5 E−07
-
2 E+04
2 E+04
/ET/ET
Co-56
-
1 E−07
1 E−07
-
5 E+03
4 E+03
/St/St
Co-57
-
1 E−06
9 E−07
-
5 E+04
3 E+04
/St/St
Co-58m
-
3 E−05
3 E−05
-
1 E+06
1 E+06
/St/St
Co-58
-
4 E−07
3 E−07
-
1 E+04
1 E+04
/St/St
Co-60m
-
4 E−04
4 E−04
-
1 E+07
1 E+07
/St/St
Co-60
-
7 E−08
3 E−08
-
2 E+03
1 E+03
/St/St
Co-61
-
6 E−06
6 E−06
-
2 E+05
2 E+05
/ET/ET
Co-62m
-
7 E−06
6 E−06
-
2 E+05
2 E+05
/ET/ET
Ni-56 (Inorg)
4 E−07
4 E−07
-
1 E+04
1 E+04
-
ET/ET/
Ni-56 (Carbonyl)
-
4 E−07
-
-
1 E+04
-
/St/
Ni-57 (Inorg)
5 E−07
5 E−07
-
2 E+04
2 E+04
-
ET/ET/
Ni-57 (Carbonyl)
-
7 E−07
-
-
2 E+04
-
/ET/
Ni-59 (Inorg)
2 E−06
5 E−06
-
9 E+04
2 E+05
-
St/St/
Ni-59 (Carbonyl)
-
6 E−07
-
-
2 E+04
-
/St/
Ni-63 (Inorg)
1 E−06
1 E−06
-
4 E+04
6 E+04
-
St/St/
Ni-63 (Carbonyl)
-
2 E−07
-
-
1 E+04
-
/St/
Ni-65 (Inorg)
5 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
Ni-65 (Carbonyl)
-
8 E−07
-
-
3 E+04
-
/ET/
218 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ni-66 (Inorg)
7 E−07
2 E−07
-
2 E+04
1 E+04
-
St/St/
Ni-66 (Carbonyl)
-
2 E−07
-
-
1 E+04
-
/ET/
Cu-60
5 E−06
4 E−06
4 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Cu-61
3 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Cu-64
4 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/E/E
Cu-67
2 E−06
1 E−06
9 E−07
8 E+04
3 E+04
3 E+04
ET/St/St
Zn-62
-
-
8 E−07
-
-
3 E+04
/ /St
Zn-63
-
-
5 E−06
-
-
2 E+05
/ /ET
Zn-65
-
-
2 E−07
-
-
7 E+03
/ /St
Zn-69m
-
-
1 E−06
-
-
6 E+04
/ /St
Zn-69
-
-
7 E−06
-
-
2 E+05
/ /ET
Zn-71m
-
-
1 E−06
-
-
5 E+04
/ /ET
Zn-72
-
-
3 E−07
-
-
1 E+04
/ /St
Ga-65
1 E−05
9 E−06
-
4 E+05
3 E+05
-
ET/ET/
Ga-66
8 E−07
7 E−07
-
3 E+04
2 E+04
-
ET/St/
Ga-67
3 E−06
2 E−06
-
1 E+05
7 E+04
-
ET/St/
Ga-68
6 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
Ga-70
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Ga-72
5 E−07
5 E−07
-
2 E+04
2 E+04
-
ET/ET/
Ga-73
4 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/St/
Ge-66
2 E−06
2 E−06
-
9 E+04
9 E+04
-
ET/ET/
Ge-67
1 E−05
7 E−06
-
3 E+05
2 E+05
-
ET/ET/
Ge-68
6 E−07
7 E−08
-
2 E+04
2 E+03
-
ET/St/
Ge-69
1 E−06
1 E−06
-
3 E+04
3 E+04
-
ET/ET/
Ge-71
5 E−05
5 E−05
-
2 E+06
1 E+06
-
ET/E/
Ge-75
1 E−05
7 E−06
-
4 E+05
2 E+05
-
ET/ET/
DOE G 441.1-1C 219
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ge-77
1 E−06
1 E−06
-
4 E+04
4 E+04
-
ET/ET/
Ge-78
3 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/ET/
As-69
-
9 E−06
-
-
3 E+05
-
/ET/
As-70
-
2 E−06
-
-
8 E+04
-
/ET/
As-71
-
1 E−06
-
-
4 E+04
-
/St/
As-72
-
4 E−07
-
-
1 E+04
-
/St/
As-73
-
8 E−07
-
-
3 E+04
-
/St/
As-74
-
3 E−07
-
-
1 E+04
-
/St/
As-76
-
6 E−07
-
-
2 E+04
-
/St/
As-77
-
1 E−06
-
-
4 E+04
-
/St/
As-78
-
3 E−06
-
-
1 E+05
-
/ET/
Se-70
2 E−06
2 E−06
-
1 E+05
9 E+04
-
ET/ET/
Se-73m
1 E−05
1 E−05
-
5 E+05
4 E+05
-
ET/ET/
Se-73
1 E−06
1 E−06
-
6 E+04
Section 164
5 E+04
-
ET/ET/
Se-75
4 E−07
3 E−07
-
1 E+04
1 E+04
-
St/St/
Se-79
3 E−07
1 E−07
-
1 E+04
6 E+03
-
K/St/
Se-81m
1 E−05
6 E−06
-
3 E+05
2 E+05
-
ET/ET/
Se-81
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Se-83
6 E−06
5 E−06
-
2 E+05
1 E+05
-
ET/ET/
Br-74m
3 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/ET/
Br-74
4 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
Br-75
4 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/ET/
Br-76
5 E−07
5 E−07
-
2 E+04
2 E+04
-
ET/ET/
Br-77
2 E−06
2 E−06
-
7 E+04
7 E+04
-
ET/ET/
Br-80m
6 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/St/
Br-80
3 E−05
2 E−05
-
1 E+06
7 E+05
-
ET/ET/
220 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Br-82
3 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/ET/
Br-83
9 E−06
6 E−06
-
3 E+05
2 E+05
-
ET/ET/
Br-84
7 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
Rb-79
8 E−06
-
-
2 E+05
-
-
ET/ /
Rb-81m
1 E−05
-
-
6 E+05
-
-
ET/ /
Rb-81
2 E−06
-
-
1 E+05
-
-
ET/ /
Rb-82m
8 E−07
-
-
3 E+04
-
-
ET/ /
Rb-83
5 E−07
-
-
2 E+04
-
-
St/ /
Rb-84
3 E−07
-
-
1 E+04
-
-
St/ /
Rb-86
4 E−07
-
-
1 E+04
-
-
St/ /
Rb-87
7 E−07
-
-
2 E+04
-
-
St/ /
Rb-88
1 E−05
-
-
5 E+05
-
-
ET/ /
Rb-89
1 E−05
-
-
3 E+05
-
-
ET/ /
Sr-80
3 E−06
-
2 E−06
1 E+05
-
9 E+04
ET/ /St
Sr-81
7 E−06
-
5 E−06
2 E+05
-
2 E+05
ET/ /ET
Sr-82
1 E−07
-
7 E−08
6 E+03
-
2 E+03
St/ /St
Sr-83
1 E−06
-
9 E−07
3 E+04
-
3 E+04
ET/ /ET
Sr-85m
4 E−05
-
3 E−05
1 E+06
-
1 E+06
ET/ /ET
Sr-85
1 E−06
-
8 E−07
3 E+04
-
3 E+04
St/ /St
Sr-87m
1 E−05
-
9 E−06
4 E+05
-
3 E+05
ET/ /ET
Sr-89
4 E−07
-
1 E−07
1 E+04
-
3 E+03
St/ /St
Sr-90
1 E−08
-
7 E−09
4 E+02
-
2 E+02
BS/ /St
Sr-91
1 E−06
-
9 E−07
5 E+04
-
3 E+04
ET/ /St
Sr-92
2 E−06
-
1 E−06
8 E+04
-
6 E+04
ET/ /St
Y-86m
-
7 E−06
6 E−06
-
2 E+05
2 E+05
/ET/ET
Y-86
-
4 E−07
4 E−07
-
1 E+04
1 E+04
/ET/ET
DOE G 441.1-1C 221
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Y-87
-
9 E−07
8 E−07
-
3 E+04
3 E+04
/ET/ET
Y-88
-
1 E−07
1 E−07
-
6 E+03
6 E+03
/St/St
Y-90m
-
4 E−06
4 E−06
-
1 E+05
1 E+05
/St/St
Y-90
-
3 E−07
3 E−07
-
1 E+04
1 E+04
/St/St
Y-91m
-
2 E−05
2 E−05
-
7 E+05
7 E+05
/ET/ET
Y-91
-
1 E−07
9 E−08
-
4 E+03
3 E+03
/St/St
Y-92
-
2 E−06
2 E−06
-
7 E+04
7 E+04
/St/St
Y-93
-
9 E−07
9 E−07
-
3 E+04
3 E+04
/St/St
Y-94
-
8 E−06
8 E−06
-
3 E+05
3 E+05
/ET/ET
Y-95
-
1 E−05
1 E−05
-
4 E+05
4 E+05
/ET/ET
Zr-86
5 E−07
5 E−07
5 E−07
2 E+04
2 E+04
2 E+04
ET/ET/ET
Zr-88
1 E−07
3 E−07
3 E−07
5 E+03
1 E+04
1 E+04
St/St/St
Zr-89
6 E−07
6 E−07
6 E−07
2 E+04
2 E+04
2 E+04
ET/ET/ET
Zr-93
3 E−09
1 E−08
1 E−07
1 E+02
6 E+02
5 E+03
BS/BS/BS
Zr-95
9 E−08
1 E−07
1 E−07
3 E+03
5 E+03
4 E+03
BS/St/St
Zr-97
7 E−07
4 E−07
4 E−07
2 E+04
1 E+04
1 E+04
ET/St/St
Nb-88
-
5 E−06
5 E−06
-
1 E+05
1 E+05
/ET/ET
Nb-89 (66 min)
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/ET/ET
Nb-89 (122 min)
-
2 E−06
2 E−06
-
1 E+05
1 E+05
/ET/ET
Nb-90
-
3 E−07
3 E−07
-
1 E+04
1 E+04
/ET/ET
Nb-93m
-
1 E−06
6 E−07
-
7 E+04
2 E+04
/St/St
Nb-94
-
7 E−08
2 E−08
-
2 E+03
Section 165
8 E+02
/St/St
Nb-95m
-
7 E−07
6 E−07
-
2 E+04
2 E+04
/St/St
Nb-95
-
4 E−07
4 E−07
-
1 E+04
1 E+04
/St/St
Nb-96
-
4 E−07
4 E−07
-
1 E+04
1 E+04
/ET/ET
Nb-97
-
5 E−06
5 E−06
-
1 E+05
1 E+05
/ET/ET
222 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Nb-98
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/ET/ET
Mo-90
8 E−07
-
7 E−07
3 E+04
-
2 E+04
ET/ /ET
Mo-93m
1 E−06
-
1 E−06
3 E+04
-
3 E+04
ET/ /ET
Mo-93
2 E−07
-
4 E−07
7 E+03
-
1 E+04
BS/ /St
Mo-99
1 E−06
-
5 E−07
5 E+04
-
1 E+04
E/ /St
Mo-101
8 E−06
-
6 E−06
3 E+05
-
2 E+05
ET/ /ET
Tc-93m
8 E−06
7 E−06
-
3 E+05
2 E+05
-
ET/ET/
Tc-93
3 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/ET/
Tc-94m
5 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
Tc-94
1 E−06
1 E−06
-
4 E+04
3 E+04
-
ET/ET/
Tc-95m
8 E−07
6 E−07
-
3 E+04
2 E+04
-
ET/St/
Tc-95
1 E−06
1 E−06
-
5 E+04
5 E+04
-
ET/ET/
Tc-96m
2 E−05
2 E−05
-
1 E+06
1 E+06
-
ET/ET/
Tc-96
3 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/ET/
Tc-97m
1 E−06
2 E−07
-
5 E+04
7 E+03
-
St/St/
Tc-97
4 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/St/
Tc-98
3 E−07
9 E−08
-
1 E+04
3 E+03
-
St/St/
Tc-99m
1 E−05
1 E−05
-
5 E+05
4 E+05
-
ET/ET/
Tc-99
1 E−06
1 E−07
-
5 E+04
6 E+03
-
St/St/
Tc-101
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Tc-104
9 E−06
7 E−06
-
3 E+05
2 E+05
-
ET/ET/
Ru-94
5 E−06
5 E−06
5 E−06
2 E+05
1 E+05
1 E+05
ET/ET/ET
Ru-97
2 E−06
2 E−06
2 E−06
8 E+04
8 E+04
8 E+04
ET/ET/ET
Ru-103
8 E−07
2 E−07
2 E−07
3 E+04
1 E+04
9 E+03
St/St/St
Ru-105
2 E−06
2 E−06
2 E−06
9 E+04
8 E+04
8 E+04
ET/ET/ET
Ru-106
5 E−08
3 E−08
1 E−08
2 E+03
1 E+03
5 E+02
St/St/St
DOE G 441.1-1C 223
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Rh-99m
3 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Rh-99
8 E−07
6 E−07
6 E−07
3 E+04
2 E+04
2 E+04
ET/St/St
Rh-100
5 E−07
5 E−07
5 E−07
1 E+04
1 E+04
1 E+04
ET/ET/ET
Rh-101m
1 E−06
1 E−06
1 E−06
6 E+04
6 E+04
6 E+04
ET/ET/ET
Rh-101
3 E−07
3 E−07
1 E−07
1 E+04
1 E+04
6 E+03
St/St/St
Rh-102m
2 E−07
2 E−07
1 E−07
1 E+04
7 E+03
4 E+03
St/St/St
Rh-102
6 E−08
1 E−07
6 E−08
2 E+03
4 E+03
2 E+03
St/St/St
Rh-103m
4 E−04
2 E−04
2 E−04
1 E+07
8 E+06
8 E+06
St/St/St
Rh-105
3 E−06
1 E−06
1 E−06
1 E+05
5 E+04
4 E+04
ET/St/St
Rh-106m
1 E−06
1 E−06
1 E−06
6 E+04
5 E+04
5 E+04
ET/ET/ET
Rh-107
1 E−05
9 E−06
9 E−06
5 E+05
3 E+05
3 E+05
ET/ET/ET
Pd-100
5 E−07
5 E−07
5 E−07
2 E+04
2 E+04
2 E+04
ET/ET/ET
Pd-101
3 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Pd-103
4 E−06
1 E−06
1 E−06
1 E+05
6 E+04
7 E+04
E/St/St
Pd-107
1 E−05
1 E−05
1 E−06
5 E+05
4 E+05
7 E+04
K/St/St
Pd-109
2 E−06
1 E−06
1 E−06
9 E+04
4 E+04
4 E+04
St/St/St
Ag-102
9 E−06
7 E−06
7 E−06
3 E+05
2 E+05
2 E+05
ET/ET/ET
Ag-103
8 E−06
7 E−06
7 E−06
3 E+05
2 E+05
2 E+05
ET/ET/ET
Ag-104m
8 E−06
6 E−06
6 E−06
2 E+05
2 E+05
2 E+05
ET/ET/ET
Ag-104
3 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Ag-105
7 E−07
8 E−07
7 E−07
2 E+04
2 E+04
2 E+04
St/St/St
Ag-106m
2 E−07
2 E−07
2 E−07
9 E+03
9 E+03
9 E+03
ET/ET/ET
Ag-106
1 E−05
1 E−05
1 E−05
5 E+05
Section 166
4 E+05
4 E+05
ET/ET/ET
Ag-108m
7 E−08
1 E−07
2 E−08
2 E+03
4 E+03
1 E+03
St/St/St
Ag-110m
8 E−08
9 E−08
7 E−08
3 E+03
3 E+03
2 E+03
St/St/St
Ag-111
9 E−07
3 E−07
3 E−07
3 E+04
1 E+04
1 E+04
St/St/St
224 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ag-112
4 E−06
2 E−06
2 E−06
1 E+05
8 E+04
8 E+04
E/St/St
Ag-115
1 E−05
8 E−06
8 E−06
4 E+05
3 E+05
3 E+05
ET/ET/ET
Cd-104
4 E−06
4 E−06
4 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Cd-107
5 E−06
5 E−06
4 E−06
2 E+05
1 E+05
1 E+05
ET/ET/ET
Cd-109
2 E−08
9 E−08
1 E−07
9 E+02
3 E+03
4 E+03
K/K/St
Cd-113m
1 E−09
6 E−09
1 E−08
6 E+01
2 E+02
6 E+02
K/K/K
Cd-113
1 E−09
5 E−09
1 E−08
5 E+01
2 E+02
5 E+02
K/K/K
Cd-115m
3 E−08
1 E−07
1 E−07
1 E+03
3 E+03
3 E+03
K/St/St
Cd-115
9 E−07
4 E−07
4 E−07
3 E+04
1 E+04
1 E+04
K/St/St
Cd-117m
1 E−06
1 E−06
1 E−06
4 E+04
4 E+04
4 E+04
ET/ET/ET
Cd-117
2 E−06
2 E−06
2 E−06
8 E+04
7 E+04
7 E+04
ET/ET/ET
In-109
4 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
In-110 (69 min)
5 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
In-110 (5 h)
9 E−07
9 E−07
-
3 E+04
3 E+04
-
ET/ET/
In-111
1 E−06
1 E−06
-
5 E+04
5 E+04
-
ET/ET/
In-112
2 E−05
1 E−05
-
9 E+05
6 E+05
-
ET/ET/
In-113m
1 E−05
1 E−05
-
4 E+05
3 E+05
-
ET/ET/
In-114m
5 E−08
9 E−08
-
1 E+03
3 E+03
-
St/St/
In-115m
6 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
In-115
1 E−09
5 E−09
-
4 E+01
1 E+02
-
St/St/
In-116m
4 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/ET/
In-117m
5 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
In-117
7 E−06
5 E−06
-
2 E+05
2 E+05
-
ET/ET/
In-119m
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Sn-110
1 E−06
1 E−06
-
6 E+04
6 E+04
-
ET/ET/
Sn-111
1 E−05
1 E−05
-
6 E+05
5 E+05
-
ET/ET/
DOE G 441.1-1C 225
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Sn-113
7 E−07
2 E−07
-
2 E+04
1 E+04
-
St/St/
Sn-117m
8 E−07
2 E−07
-
3 E+04
9 E+03
-
BS/St/
Sn-119m
1 E−06
3 E−07
-
5 E+04
1 E+04
-
St/St/
Sn-121m
5 E−07
1 E−07
-
2 E+04
6 E+03
-
St/St/
Sn-121
4 E−06
2 E−06
-
1 E+05
7 E+04
-
ET/St/
Sn-123m
1 E−05
7 E−06
-
4 E+05
2 E+05
-
ET/ET/
Sn-123
3 E−07
1 E−07
-
1 E+04
3 E+03
-
St/St/
Sn-125
4 E−07
2 E−07
-
1 E+04
7 E+03
-
St/St/
Sn-126
4 E−08
3 E−08
-
1 E+03
1 E+03
-
St/St/
Sn-127
2 E−06
2 E−06
-
9 E+04
7 E+04
-
ET/ET/
Sn-128
2 E−06
2 E−06
-
1 E+05
8 E+04
-
ET/ET/
Sb-115
1 E−05
1 E−05
-
5 E+05
4 E+05
-
ET/ET/
Sb-116m
3 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/ET/
Sb-116
1 E−05
1 E−05
-
4 E+05
3 E+05
-
ET/ET/
Sb-117
1 E−05
1 E−05
-
4 E+05
3 E+05
-
ET/ET/
Sb-118m
1 E−06
1 E−06
-
4 E+04
4 E+04
-
ET/ET/
Sb-119
6 E−06
6 E−06
-
2 E+05
2 E+05
-
ET/ET/
Sb-120 (16 min)
2 E−05
2 E−05
-
1 E+06
7 E+05
-
ET/ET/
Sb-120 (6 d)
3 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/ET/
Sb-122
8 E−07
4 E−07
-
3 E+04
1 E+04
-
St/St/
Sb-124m
4 E−05
3 E−05
-
1 E+06
1 E+06
-
ET/ET/
Sb-124
2 E−07
1 E−07
-
1 E+04
4 E+03
-
St/St/
Sb-125
2 E−07
1 E−07
-
7 E+03
6 E+03
-
BS/St/
Sb-126m
1 E−05
7 E−06
-
3 E+05
2 E+05
-
ET/ET/
Sb-126
2 E−07
1 E−07
-
9 E+03
6 E+03
-
ET/St/
Sb-127
7 E−07
3 E−07
-
2 E+04
Section 167
1 E+04
-
E/St/
226 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Sb-128 (9 h)
5 E−07
5 E−07
-
2 E+04
2 E+04
-
ET/ET/
Sb-128 (10 min)
1 E−05
9 E−06
-
4 E+05
3 E+05
-
ET/ET/
Sb-129
1 E−06
1 E−06
-
6 E+04
5 E+04
-
ET/ET/
Sb-130
3 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/ET/
Sb-131
6 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
Te-116 (Vapor)
-
6 E−06
-
-
2 E+05
-
/St /
Te-116
2 E−06
2 E−06
-
8 E+04
7 E+04
-
ET/ET/
Te-121m (Vapor)
-
4 E−08
-
-
1 E+03
-
/BS/
Te-121m
1 E−07
1 E−07
-
4 E+03
5 E+03
-
BS/St/
Te-121 (Vapor)
-
1 E−06
-
-
4 E+04
-
/St /
Te-121
1 E−06
1 E−06
-
3 E+04
3 E+04
-
ET/ET/
Te-123m (Vapor)
-
5 E−08
-
-
2 E+03
-
/BS/
Te-123m
1 E−07
1 E−07
-
4 E+03
6 E+03
-
BS/St/
Te-123 (Vapor)
-
1 E−08
-
-
4 E+02
-
/BS/
Te-123
2 E−08
5 E−08
-
1 E+03
1 E+03
-
BS/BS/
Te-125m (Vapor)
-
1 E−07
-
-
3 E+03
-
/BS/
Te-125m
2 E−07
1 E−07
-
9 E+03
7 E+03
-
BS/St/
Te-127m (Vapor)
-
6 E−08
-
-
2 E+03
-
/BS/
Te-127m
1 E−07
9 E−08
-
5 E+03
3 E+03
-
BS/St/
Te-127 (Vapor)
-
7 E−06
-
-
2 E+05
-
/St/
Te-127
5 E−06
3 E−06
-
2 E+05
1 E+05
-
ET/St/
Te-129m (Vapor)
-
1 E−07
-
-
5 E+03
-
/St/
Te-129m
3 E−07
1 E−07
-
1 E+04
3 E+03
-
St/St/
Te-129 (Vapor)
-
1 E−05
-
-
5 E+05
-
/St/
Te-129
1 E−05
7 E−06
-
4 E+05
2 E+05
-
ET/ET/
Te-131m (Vapor)
-
1 E−07
-
-
5 E+03
-
/T/
DOE G 441.1-1C 227
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Te-131m
3 E−07
3 E−07
-
1 E+04
1 E+04
-
T/St/
Te-131 (Vapor)
-
6 E−06
-
-
2 E+05
-
/T/
Te-131
1 E−05
7 E−06
-
4 E+05
2 E+05
-
ET/ET/
Te-132 (Vapor)
-
7 E−08
-
-
2 E+03
-
/T/
Te-132
1 E−07
1 E−07
-
6 E+03
6 E+03
-
T/St/
Te-133m (Vapor)
-
1 E−06
-
-
6 E+04
-
/T/
Te-133m
3 E−06
2 E−06
-
1 E+05
1 E+05
-
T/ET/
Te-133 (Vapor)
-
7 E−06
-
-
2 E+05
-
/T/
Te-133
1 E−05
9 E−06
-
4 E+05
3 E+05
-
ET/ET/
Te-134 (Vapor)
-
6 E−06
-
-
2 E+05
-
/St/
Te-134
3 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/ET/
I-120m (Methyl)
4 E−06
-
-
1 E+05
-
-
T/ /
I-120m (Vapor)
-
3 E−06
-
-
1 E+05
-
/St /
I-120m
2 E−06
-
-
8 E+04
-
-
ET/ /
I-120 (Methyl)
1 E−06
-
-
6 E+04
-
-
T/ /
I-120 (Vapor)
-
1 E−06
-
-
5 E+04
-
/T/
I-120
2 E−06
-
-
1 E+05
-
-
E/ /
I-121 (Methyl)
5 E−06
-
-
2 E+05
-
-
T/ /
I-121 (Vapor)
-
4 E−06
-
-
1 E+05
-
/T/
I-121
8 E−06
-
-
3 E+05
-
-
T/ /
I-123 (Methyl)
1 E−06
-
-
7 E+04
-
-
T/ /
I-123 (Vapor)
-
1 E−06
-
-
5 E+04
-
/T/
I-123
2 E−06
-
-
1 E+05
-
-
T/ /
I-124 (Methyl)
3 E−08
-
-
1 E+03
-
-
T/ /
I-124 (Vapor)
-
2 E−08
-
-
9 E+02
-
/T/
I-124
4 E−08
-
-
1 E+03
-
-
T/ /
228 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
I-125 (Methyl)
2 E−08
-
-
9 E+02
-
-
T/ /
I-125 (Vapor)
-
2 E−08
-
-
7 E+02
-
/T/
I-125
3 E−08
-
-
1 E+03
-
-
T/ /
I-126 (Methyl)
1 E−08
-
-
5 E+02
-
-
T/ /
I-126 (Vapor)
-
1 E−08
-
-
4 E+02
-
/T/
I-126
2 E−08
-
-
7 E+02
-
-
T/ /
I-128 (Methyl)
3 E−05
-
-
1 E+06
-
-
T/ /
I-128 (Vapor)
-
8 E−06
Section 168
-
-
3 E+05
-
/St/
I-128
1 E−05
-
-
6 E+05
-
-
ET/ /
I-129 (Methyl)
3 E−09
-
-
1 E+02
-
-
T/ /
I-129 (Vapor)
-
2 E−09
-
-
1 E+02
-
/T/
I-129
5 E−09
-
-
2 E+02
-
-
T/ /
I-130 (Methyl)
2 E−07
-
-
7 E+03
-
-
T/ /
I-130 (Vapor)
-
1 E−07
-
-
6 E+03
-
/T/
I-130
3 E−07
-
-
1 E+04
-
-
T/ /
I-131 (Methyl)
1 E−08
-
-
6 E+02
-
-
T/ /
I-131 (Vapor)
-
1 E−08
-
-
5 E+02
-
/T/
I-131
2 E−08
-
-
9 E+02
-
-
T/ /
I-132m (Methyl)
1 E−06
-
-
7 E+04
-
-
T/ /
I-132m (Vapor)
-
1 E−06
-
-
6 E+04
-
/T/
I-132m
3 E−06
-
-
1 E+05
-
-
T/ /
I-132 (Methyl)
1 E−06
-
-
6 E+04
-
-
T/ /
I-132 (Vapor)
-
1 E−06
-
-
5 E+04
-
/T/
I-132
2 E−06
-
-
7 E+04
-
-
T/ /
I-133 (Methyl)
9 E−08
-
-
3 E+03
-
-
T/ /
I-133 (Vapor)
-
7 E−08
-
-
2 E+03
-
/T/
DOE G 441.1-1C 229
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
I-133
1 E−07
-
-
5 E+03
-
-
T/ /
I-134 (Methyl)
8 E−06
-
-
2 E+05
-
-
T/ /
I-134 (Vapor)
-
3 E−06
-
-
1 E+05
-
/St/
I-134
3 E−06
-
-
1 E+05
-
-
ET/ /
I-135 (Methyl)
4 E−07
-
-
1 E+04
-
-
T/ /
I-135 (Vapor)
-
3 E−07
-
-
1 E+04
-
/T/
I-135
6 E−07
-
-
2 E+04
-
-
T/ /
Cs-125
1 E−05
-
-
4 E+05
-
-
ET/ /
Cs-127
4 E−06
-
-
1 E+05
-
-
ET/ /
Cs-129
2 E−06
-
-
9 E+04
-
-
ET/ /
Cs-130
1 E−05
-
-
6 E+05
-
-
ET/ /
Cs-131
7 E−06
-
-
2 E+05
-
-
ET/ /
Cs-132
9 E−07
-
-
3 E+04
-
-
ET/ /
Cs-134m
8 E−06
-
-
2 E+05
-
-
ET/ /
Cs-134
5 E−08
-
-
2 E+03
-
-
St/ /
Cs-135m
8 E−06
-
-
2 E+05
-
-
ET/ /
Cs-135
5 E−07
-
-
2 E+04
-
-
St/ /
Cs-136
2 E−07
-
-
1 E+04
-
-
E/ /
Cs-137
8 E−08
-
-
3 E+03
-
-
St/ /
Cs-138
5 E−06
-
-
2 E+05
-
-
ET/ /
Ba-126
4 E−06
-
-
1 E+05
-
-
ET/ /
Ba-128
4 E−07
-
-
1 E+04
-
-
St/ /
Ba-131m
4 E−05
-
-
1 E+06
-
-
ET/ /
Ba-131
1 E−06
-
-
4 E+04
-
-
ET/ /
Ba-133m
2 E−06
-
-
7 E+04
-
-
St/ /
Ba-133
3 E−07
-
-
1 E+04
-
-
St/ /
230 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ba-135m
2 E−06
-
-
9 E+04
--
-
St/ /
Ba-139
1 E−05
-
-
3 E+05
-
-
St/ /
Ba-140
3 E−07
-
-
1 E+04
-
-
St/ /
Ba-141
1 E−05
-
-
4 E+05
-
-
ET/ /
Ba-142
9 E−06
-
-
3 E+05
-
-
ET/ /
La-131
1 E−05
8 E−06
-
4 E+05
3 E+05
-
ET/ET/
La-132
1 E−06
1 E−06
-
5 E+04
5 E+04
-
ET/ET/
La-135
1 E−05
1 E−05
-
4 E+05
4 E+05
-
ET/ET/
La-137
4 E−08
2 E−07
-
1 E+03
8 E+03
-
L/L/
La-138
3 E−09
1 E−08
-
1 E+02
4 E+02
-
St/St/
La-140
4 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/St/
La-141
5 E−06
2 E−06
-
1 E+05
9 E+04
-
St/St/
La-142
2 E−06
2 E−06
-
9 E+04
8 E+04
-
ET/ET/
La-143
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Ce-134
-
3 E−07
3 E−07
-
1 E+04
1 E+04
/St/St
Ce-135
-
5 E−07
5 E−07
-
2 E+04
2 E+04
/ET/ET
Ce-137m
-
1 E−06
9 E−07
-
3 E+04
3 E+04
/St/St
Ce-137
-
1 E−05
1 E−05
-
7 E+05
7 E+05
/ET/ET
Ce-139
-
4 E−07
4 E−07
-
1 E+04
1 E+04
/St/St
Ce-141
-
2 E−07
1 E−07
-
7 E+03
6 E+03
/St/St
Ce-143
-
5 E−07
5 E−07
-
2 E+04
2 E+04
/St/St
Ce-144
-
2 E−08
1 E−08
-
9 E+02
7 E+02
/St/St
Pr-136
-
1 E−05
1 E−05
-
3 E+05
3 E+05
Section 169
/ET/ET
Pr-137
-
9 E−06
9 E−06
-
3 E+05
3 E+05
/ET/ET
Pr-138m
-
2 E−06
2 E−06
-
7 E+04
7 E+04
/ET/ET
Pr-139
-
1 E−05
1 E−05
-
5 E+05
5 E+05
/ET/ET
DOE G 441.1-1C 231
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Pr-142m
-
6 E−05
5 E−05
-
2 E+06
2 E+06
/St/St
Pr-142
-
8 E−07
7 E−07
-
2 E+04
2 E+04
/St/St
Pr-143
-
2 E−07
2 E−07
-
1 E+04
9 E+03
/St/St
Pr-144
-
1 E−05
1 E−05
-
4 E+05
4 E+05
/ET/ET
Pr-145
-
2 E−06
2 E−06
-
8 E+04
8 E+04
/St/St
Pr-147
-
9 E−06
9 E−06
-
3 E+05
3 E+05
/ET/ET
Nd-136
-
4 E−06
4 E−06
-
1 E+05
1 E+05
/ET/ET
Nd-138
-
1 E−06
1 E−06
-
5 E+04
5 E+04
/St/St
Nd-139m
-
1 E−06
1 E−06
-
5 E+04
5 E+04
/ET/ET
Nd-139
-
1 E−05
1 E−05
-
6 E+05
6 E+05
/ET/ET
Nd-141
-
3 E−05
3 E−05
-
1 E+06
1 E+06
/ET/ET
Nd-147
-
2 E−07
2 E−07
-
1 E+04
9 E+03
/St/St
Nd-149
-
4 E−06
4 E−06
-
1 E+05
1 E+05
/ET/ET
Nd-151
-
9 E−06
9 E−06
-
3 E+05
3 E+05
/ET/ET
Pm-141
-
1 E−05
1E−05
-
4 E+05
4 E+05
/ET/ET
Pm-143
-
5 E−07
6 E−07
-
2 E+04
2 E+04
/St/St
Pm-144
-
1 E−07
1 E−07
-
3 E+03
5 E+03
/St/St
Pm-145
-
1 E−07
4 E−07
-
5 E+03
1 E+04
/BS/St
Pm-146
-
4 E−08
6 E−08
-
1 E+03
2 E+03
/St/St
Pm-147
-
1 E−07
1 E−07
-
4 E+03
6 E+03
/BS/St
Pm-148m
-
1 E−07
1 E−07
-
5 E+03
4 E+03
/St/St
Pm-148
-
2 E−07
2 E−07
-
9 E+03
9 E+03
/St/St
Pm-149
-
7 E−07
6 E−07
-
2 E+04
2 E+04
/St/St
Pm-150
-
2 E−06
2 E−06
-
8 E+04
8 E+04
/ET/ET
Pm-151
-
9 E−07
8 E−07
-
3 E+04
3 E+04
/St/St
Sm-141m
-
5 E−06
-
-
2 E+05
-
/ET/
232 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Sm-141
-
1 E−05
-
-
4 E+05
-
/ET/
Sm-142
-
4 E−06
-
-
1 E+05
-
/ET/
Sm-145
-
4 E−07
-
-
1 E+04
-
/BS/
Sm-146
-
2 E−11
-
-
1 E+00
-
/BS/
Sm-147
-
2 E−11
-
-
1 E+00
-
/BS/
Sm-151
-
7 E−08
-
-
2 E+03
-
/BS/
Sm-153
-
8 E−07
-
-
3 E+04
-
/St/
Sm-155
-
1 E−05
-
-
3 E+05
-
/ET/
Sm-156
-
2 E−06
-
-
7 E+04
-
/St/
Eu-145
-
5 E−07
-
-
2 E+04
-
/ET/
Eu-146
-
3 E−07
-
-
1 E+04
-
/ET/
Eu-147
-
5 E−07
-
-
2 E+04
-
/St/
Eu-148
-
2 E−07
-
-
9 E+03
-
/St/
Eu-149
-
2 E−06
-
-
9 E+04
-
/St/
Eu-150 (12 h)
-
2 E−06
-
-
7 E+04
-
/St/
Eu-150 (34 yr)
-
1 E−08
-
-
6 E+02
-
/St/
Eu-152m
-
1 E−06
-
-
6 E+04
-
/St/
Eu-152
-
2 E−08
-
-
7 E+02
-
/St/
Eu-154
-
1 E−08
-
-
5 E+02
-
/St/
Eu-155
-
7 E−08
-
-
2 E+03
-
/BS/
Eu-156
-
1 E−07
-
-
6 E+03
-
/St/
Eu-157
-
1 E−06
-
-
4 E+04
-
/St/
Eu-158
-
5 E−6
-
-
1 E+05
-
/ET/
Gd-145
9 E−06
7 E−06
-
3 E+05
2 E+05
-
ET/ET/
Gd-146
1 E−07
1 E−07
-
4 E+03
4 E+03
-
St/St/
Gd-147
7 E−07
6 E−07
-
2 E+04
2 E+04
-
ET/ET/
DOE G 441.1-1C 233
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Gd-148
5 E−12
2 E−11
-
2 E−01
9 E−01
-
BS/BS/
Gd-149
1 E−06
7 E−07
-
4 E+04
2 E+04
-
ET/ET/
Gd-151
2 E−07
8 E−07
-
9 E+03
3 E+04
-
BS/St/
Gd-152
7 E−12
3 E−11
-
2 E−01
1 E+00
-
BS/BS/
Gd-153
9 E−08
4 E−07
-
3 E+03
1 E+04
-
BS/St/
Section 170
Gd-159
3 E−06
1 E−06
-
1 E+05
5 E+04
-
St/St/
Tb-147
-
2 E−06
-
-
1 E+05
-
/ET/
Tb-149
-
1 E−07
-
-
6 E+03
-
/St/
Tb-150
-
2 E−06
-
-
8 E+04
-
/ET/
Tb-151
-
1 E−06
-
-
4 E+04
-
/ET/
Tb-153
-
2 E−06
-
-
8 E+04
-
/St/
Tb-154
-
5 E−07
-
-
2 E+04
-
/ET/
Tb-155
-
2 E−06
-
-
8 E+04
-
/St/
Tb-156m (24 h)
-
2 E−06
-
-
9 E+04
-
/St/
Tb-156m (5 h)
-
4 E−06
-
-
1 E+05
-
/St/
Tb-156
-
4 E−07
-
-
1 E+04
-
/E/
Tb-157
-
2 E−07
-
-
8 E+03
-
/BS/
Tb-158
-
1 E−08
-
-
6 E+02
-
/BS/
Tb-160
-
1 E−07
-
-
3 E+03
-
/St/
Tb-161
-
4 E−07
-
-
1 E+04
-
/St/
Dy-155
-
2 E−06
-
-
1 E+05
-
/ET/
Dy-157
-
5 E−06
-
-
1 E+05
-
/ET/
Dy-159
-
2 E−06
-
-
8 E+04
-
/BS/
Dy-165
-
6 E−06
-
-
2 E+05
-
/ET/
Dy-166
-
3 E−07
-
-
1 E+04
-
/St/
Ho-155
-
1 E−05
-
-
4 E+05
-
/ET/
234 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ho-157
-
2 E−05
-
-
1 E+06
-
/ET/
Ho-159
-
2 E−05
-
-
9 E+05
-
/ET/
Ho-161
-
3 E−05
-
-
1 E+06
-
/ET/
Ho-162m
-
9 E−06
-
-
3 E+05
-
/ET/
Ho-162
-
5 E−05
-
-
2 E+06
-
/ET/
Ho-164m
-
3 E−05
-
-
1 E+06
-
/St/
Ho-164
-
2 E−05
-
-
8 E+05
-
/ET/
Ho-166m
-
7 E−09
-
-
2 E+02
-
/St/
Ho-166
-
6 E−07
-
-
2 E+04
-
/St/
Ho-167
-
4 E−06
-
-
1 E+05
-
/ET/
Er-161
-
3 E−06
-
-
1 E+05
-
/ET/
Er-165
-
2 E−05
-
-
1 E+06
-
/ET/
Er-169
-
6 E−07
-
-
2 E+04
-
/St/
Er-171
-
1 E−06
-
-
6 E+04
-
/St/
Er-172
-
4 E−07
-
-
1 E+04
-
/St/
Tm-162
-
9 E−06
-
-
3E+05
-
/ET/
Tm-166
-
1 E−06
-
-
4 E+04
-
/ET/
Tm-167
-
5 E−07
-
-
2 E+04
-
/St/
Tm-170
-
1 E−07
-
-
4 E+03
-
/St/
Tm-171
-
2 E−07
-
-
9 E+03
-
/BS/
Tm-172
-
4 E−07
-
-
1 E+04
-
/St/
Tm-173
-
2 E−06
-
-
8 E+04
-
/St/
Tm-175
-
8 E−06
-
-
2 E+05
-
/ET/
Yb-162
-
1 E−05
1 E−05
-
5 E+05
5 E+05
/ET/ET
Yb-166
-
6 E−07
5 E−07
-
2 E+04
2 E+04
/St/St
Yb-167
-
3 E−05
3 E−05
-
1 E+06
1 E+06
/ET/ET
DOE G 441.1-1C 235
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Yb-169
-
2 E−07
2 E−07
-
9 E+03
8 E+03
/St/St
Yb-175
-
8 E−07
8 E−07
-
3 E+04
2 E+04
/St/St
Yb-177
-
6 E−06
5 E−06
-
2 E+05
2 E+05
/ET/ET
Yb-178
-
5 E−06
5 E−06
-
1 E+05
1 E+05
/ET/E
Lu-169
-
9 E−07
9 E−07
-
3 E+04
3 E+04
/ET/ET
Lu-170
-
4 E−07
4 E−07
-
1 E+04
1 E+04
/ET/ET
Lu-171
-
6 E−07
6 E−07
-
2 E+04
2 E+04
/St/St
Lu-172
-
3 E−07
3 E−07
-
1 E+04
1 E+04
/St/St
Lu-173
-
2 E−07
4 E−07
-
8 E+03
1 E+04
/BS/St
Lu-174m
-
2 E−07
2 E−07
-
7 E+03
8 E+03
/BS/St
Lu-174
-
9 E−08
2 E−07
-
3 E+03
8 E+03
/BS/St
Lu-176m
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/St/St
Lu-176
-
3 E−09
1 E−08
-
1 E+02
6 E+02
/BS/St
Lu-177m
-
5 E−08
4 E−08
-
2 E+03
1 E+03
/St/St
Lu-177
-
5 E−07
5 E−07
-
2 E+04
1 E+04
/St/St
Lu-178m
-
4 E−06
4 E−06
-
1 E+05
1 E+05
/ET/ET
Lu-178
-
8 E−06
8 E−06
-
3 E+05
3 E+05
/ET/ET
Lu-179
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/St/St
Hf-170
1 E−06
1 E−06
-
4 E+04
4 E+04
-
ET/ET/
Hf-172
6 E−09
3 E−08
-
2 E+02
1 E+03
-
BS/BS/
Section 171
Hf-173
2 E−06
2 E−06
-
9 E+04
8 E+04
-
ET/ET/
Hf-175
5 E−07
6 E−07
-
2 E+04
2 E+04
-
BS/St/
Hf-177m
2 E−06
1 E−06
-
9 E+04
6 E+04
-
ET/ET/
Hf-178m
8 E−10
4 E−09
-
3 E+01
1 E+02
-
BS/BS/
Hf-179m
2 E−07
1 E−07
-
8 E+03
6 E+03
-
BS/St/
Hf-180m
2 E−06
1 E−06
-
7 E+04
6 E+04
-
ET/ET/
236 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Hf-181
1 E−07
1 E−07
-
4 E+03
5 E+03
-
BS/St/
Hf-182m
5 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
Hf-182
5 E−10
2 E−09
-
2 E+01
9 E+01
-
BS/BS/
Hf-183
6 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
Hf-184
1 E−06
1 E−06
-
5 E+04
4 E+04
-
ET/St/
Ta-172
-
5 E−06
5 E−06
-
1 E+05
1 E+05
/ET/ET
Ta-173
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/E/E
Ta-174
-
5 E−06
5 E−06
-
2 E+05
2 E+05
/ET/ET
Ta-175
-
1 E−06
1 E−06
-
6 E+04
6 E+04
/ET/ET
Ta-176
-
1 E−06
1 E−06
-
3 E+04
3 E+04
/ET/ET
Ta-177
-
4 E−06
4 E−06
-
1 E+05
1 E+05
/St/St
Ta-178
-
3 E−06
3 E−06
-
1 E+05
1 E+05
/ET/ET
Ta-179
-
4 E−06
1 E−06
-
1 E+05
7 E+04
/St/St
Ta-180m
-
9 E−06
9 E−06
-
3 E+05
3 E+05
/St/St
Ta-180
-
1 E−07
4 E−08
-
4 E+03
1 E+03
/St/St
Ta-182m
-
6 E−06
6 E−06
-
2 E+05
2 E+05
/ET/ET
Ta-182
-
9 E−08
7 E−08
-
3 E+03
2 E+03
/St/St
Ta-183
-
3 E−07
2 E−07
-
1 E+04
1 E+04
/St/St
Ta-184
-
8 E−07
8 E−07
-
3 E+04
3 E+04
/ET/ET
Ta-185
-
5 E−06
5 E−06
-
2 E+05
1 E+05
/ET/ET
Ta-186
-
7 E−06
7 E−06
-
2 E+05
2 E+05
/ET/ET
W-176
3 E−06
-
-
1 E+05
-
-
ET/ /
W-177
5 E−06
-
-
2 E+05
-
-
ET/ /
W-178
3 E−06
-
-
1 E+05
-
-
ET/ /
W-179
1 E−04
-
-
5 E+06
-
-
ET/ /
W-181
1 E−05
-
-
4 E+05
-
-
ET/ /
DOE G 441.1-1C 237
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
W-185
2 E−06
-
-
9 E+04
-
-
St/ /
W-187
1 E−06
-
-
5 E+04
-
-
ET/ /
W-188
6 E−07
-
-
2 E+04
-
-
St/ /
Re-177
1 E−05
1 E−05
-
6 E+05
4 E+05
-
ET/ET/
Re-178
1 E−05
1 E−05
-
5 E+05
3 E+05
-
ET/ET/
Re-181
1 E−06
1 E−06
-
5 E+04
4 E+04
-
ET/ET/
Re-182 (64 h)
4 E−07
3 E−07
-
1 E+04
1 E+04
-
ET/St/
Re-182 (12 h)
1 E−06
1 E−06
-
4 E+04
4 E+04
-
ET/ET/
Re-184m
6 E−07
1 E−07
-
2 E+04
4 E+03
-
St/St/
Re-184
7 E−07
3 E−07
-
2 E+04
1 E+04
-
ET/St/
Re-186m
4 E−7
7 E−08
-
1 E+04
2 E+03
-
St/St/
Re-186
7 E−07
4 E−07
-
2 E+04
1 E+04
-
St/St/
Re-187
2 E−04
1 E−04
-
8 E+06
4 E+06
-
St/St/
Re-188m
3 E−05
2 E−05
-
1 E+06
1 E+06
-
St/St/
Re-188
8 E−07
7 E−07
-
3 E+04
2 E+04
-
St/St/
Re-189
1 E−06
9 E−07
-
4 E+04
3 E+04
-
St/St/
Os-180
1 E−05
1 E−05
1 E−05
5 E+05
3 E+05
3 E+05
ET/ET/ET
Os-181
3 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Os-182
1 E−06
9 E−07
9 E−07
3 E+04
3 E+04
3 E+04
ET/ET/ET
Os-185
4 E−07
5 E−07
5 E−07
1 E+04
2 E+04
1 E+04
St/St/St
Os-189m
1 E−04
7 E−05
7 E−05
4 E+06
2 E+06
2 E+06
St/St/St
Os-191m
1 E−05
4 E−06
4 E−06
5 E+05
1 E+05
1 E+05
St/St/St
Os-191
1 E−06
4 E−07
3 E−07
5 E+04
1 E+04
1 E+04
St/St/St
Os-193
2 E−06
8 E−07
8 E−07
7 E+04
3 E+04
3 E+04
St/St/St
Os-194
4 E−08
4 E−08
1 E−08
1 E+03
1 E+03
4 E+02
St/St/St
Ir-182
9 E−06
7 E−06
7 E−06
3 E+05
2 E+05
2 E+05
Section 172
ET/ET/ET
238 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Ir-184
1 E−06
1 E−06
1 E−06
7 E+04
6 E+04
7 E+04
ET/ET/ET
Ir-185
2 E−06
1 E−06
1 E−06
7 E+04
7 E+04
7 E+04
ET/ET/ET
Ir-186 (16 h)
8 E−07
7 E−07
7 E−07
2 E+04
2 E+04
2 E+04
ET/ET/ET
Ir-186 (2 h)
5 E−06
4 E−06
4 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Ir-187
4 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/ET/ET
Ir-188
6 E−07
6 E−07
6 E−07
2 E+04
2 E+04
2 E+04
ET/ET/ET
Ir-189
3 E−06
1 E−06
1 E−06
1 E+05
5 E+04
4 E+04
St/St/St
Ir-190m (3 h)
2 E−06
2 E−06
2 E−06
8 E+04
8 E+04
7 E+04
ET/ET/ET
Ir-190m (1 h)
9 E−05
5 E−05
5 E−05
3 E+06
2 E+06
1 E+06
ET/St/St
Ir-190
4 E−07
2 E−07
2 E−07
1 E+04
9 E+03
8 E+03
ET/St/St
Ir-192m
1 E−07
1 E−07
2 E−08
3 E+03
6 E+03
1 E+03
St/St/St
Ir-192
2 E−07
1 E−07
1 E−07
9 E+03
5 E+03
4 E+03
St/St/St
Ir-194m
8 E−08
8 E−08
6 E−08
3 E+03
3 E+03
2 E+03
St/St/St
Ir-194
1 E−06
7 E−07
7 E−07
5 E+04
2 E+04
2 E+04
St/St/St
Ir-195m
2 E−06
2 E−06
2 E−06
9 E+04
7 E+04
7 E+04
ET/ET/ET
Ir-195
7 E−06
5 E−06
4 E−06
2 E+05
1 E+05
1 E+05
ET/ET/ET
Pt-186
3 E−06
-
-
1 E+05
-
-
ET/ /
Pt-188
8 E−07
-
-
3 E+04
-
-
E/ /
Pt-189
3 E−06
-
-
1 E+05
-
-
ET/ /
Pt-191
1 E−06
-
-
7 E+04
-
-
ET/ /
Pt-193m
2 E−06
-
-
8 E+04
-
-
ET/ /
Pt-193
2 E−05
-
-
7 E+05
-
-
ET/ /
Pt-195m
1 E−06
-
-
5 E+04
-
-
ET/ /
Pt-197m
7 E−06
-
-
2 E+05
-
-
ET/ /
Pt-197
3 E−06
-
-
1 E+05
-
-
ET/ /
Pt-199
1 E−05
-
-
4 E+05
-
-
ET/ /
DOE G 441.1-1C 239
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Pt-200
1 E−06
-
-
5 E+04
-
-
St/ /
Au-193
4 E−06
3 E−06
3 E−06
1 E+05
1 E+05
1 E+05
ET/E/St
Au-194
9 E−07
9 E−07
9 E−07
3 E+04
3 E+04
3 E+04
ET/ET/ET
Au-195
3 E−06
7 E−07
4 E−07
1 E+05
2 E+04
1 E+04
ET/St/St
Au-198m
6 E−07
2 E−07
2 E−07
2 E+04
1 E+04
1 E+04
ET/St/St
Au-198
1 E−06
5 E−07
5 E−07
4 E+04
2 E+04
1 E+04
ET/St/St
Au-199
2 E−06
8 E−07
7 E−07
7 E+04
3 E+04
2 E+04
ET/St/St
Au-200m
5 E−07
4 E−07
4 E−07
1 E+04
1 E+04
1 E+04
ET/ET/ET
Au-200
1 E−05
7E−06
7 E−06
4 E+05
2 E+05
2 E+05
ET/ET/ET
Au-201
1 E−05
1 E−05
9 E−06
5 E+05
3 E+05
3 E+05
ET/ET/ET
Hg-193m (Org)
1 E−06
-
-
4 E+04
-
-
ET/ /
Hg-193m
1 E−06
1 E−06
-
4 E+04
4 E+04
-
ET/ET/
Hg-193m (Vapor)
-
1 E−07
-
-
6 E+03
-
/St/
Hg-193 (Org)
5 E−06
-
-
1 E+05
-
-
ET/ /
Hg-193
5 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
Hg-193 (Vapor)
-
5 E−07
-
-
1 E+04
-
/St/
Hg-194 (Org)
2 E−08
-
-
1 E+03
-
-
St/ /
Hg-194
3 E−08
1 E−07
-
1 E+03
3 E+03
-
St/St/
Hg-194 (Vapor)
-
1 E−08
-
-
5 E+02
-
/St/
Hg-195m (Org)
1 E−06
-
-
5 E+04
-
-
ET/ /
Hg-195m
1 E−06
8 E−07
-
5 E+04
3 E+04
-
ET/St/
Hg-195m (Vapor)
-
6 E−08
-
-
2 E+03
-
/St/
Hg-195 (Org)
6 E−06
-
-
2 E+05
-
-
ET/ /
Hg-195
6 E−06
6 E−06
-
2 E+05
2 E+05
-
ET/ET/
Hg-195 (Vapor)
-
4 E−07
-
-
1 E+04
-
/St/
Hg-197m (Org)
1 E−06
-
-
5 E+04
-
-
ET/ /
240 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Hg-197m
1 E−06
8 E−07
-
5 E+04
Section 173
3 E+04
-
ET/St/
Hg-197m (Vapor)
-
9 E−08
-
-
3 E+03
-
/St/
Hg-197 (Org)
4 E−06
-
-
1 E+05
-
-
ET/ /
Hg-197
4 E−06
2 E−06
-
1 E+05
7 E+04
-
ET/St/
Hg-197 (Vapor)
-
1 E−07
-
-
4 E+03
-
/St/
Hg-199m (Org)
8 E−06
-
-
3 E+05
-
-
ET/ /
Hg-199m
8 E−06
5 E−06
-
3 E+05
1 E+05
-
ET/ET/
Hg-199m (Vapor)
-
3 E−06
-
-
1 E+05
-
/St/
Hg-203 (Org)
7 E−07
-
-
2 E+04
-
-
St/ /
Hg-203
9 E−07
2 E−07
-
3 E+04
1 E+04
-
St/St/
Hg-203 (Vapor)
-
8 E−08
-
-
2 E+03
-
/St/
Tl-194m
5 E−06
-
-
2 E+05
-
-
ET/ /
Tl-194
2 E−05
-
-
8 E+05
-
-
ET/ /
Tl-195
6 E−06
-
-
2 E+05
-
-
ET/ /
Tl-197
8 E−06
-
-
2 E+05
-
-
ET/ /
Tl-198m
2 E−06
-
-
9 E+04
-
-
ET/ /
Tl-198
1 E−06
-
-
5 E+04
-
-
ET/ /
Tl-199
5 E−06
-
-
2 E+05
-
-
ET/ /
Tl-200
8 E−07
-
-
3 E+04
-
-
ET/ /
Tl-201
4 E−06
-
-
1 E+05
-
-
ET/ /
Tl-202
1 E−06
-
-
5 E+04
-
-
ET/ /
Tl-204
9 E−07
-
-
3 E+04
-
-
St/ /
Pb-195m
7 E−06
-
-
2 E+05
-
-
ET/ /
Pb-198
2 E−06
-
-
9 E+04
-
-
ET/ /
Pb-199
4 E−06
-
-
1 E+05
-
-
ET/ /
Pb-200
1 E−06
-
-
4 E+04
-
-
ET/ /
DOE G 441.1-1C 241
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Pb-201
2 E−06
-
-
7 E+04
-
-
ET/ /
Pb-202m
1 E−06
-
-
6 E+04
-
-
ET/ /
Pb-202
4 E−08
-
-
1 E+03
-
-
St/ /
Pb-203
2 E−06
-
-
7 E+04
-
-
ET/ /
Pb-205
9 E−07
-
-
3 E+04
-
-
BS/ /
Pb-209
9 E−06
-
-
3 E+05
-
-
ET/ /
Pb-210
1 E−10
-
-
5 E+00
-
-
BS/ /
Pb-211
4 E−08
-
-
1 E+03
-
-
ET/ /
Pb-212
5 E−09
-
-
2 E+02
-
-
ET/ /
Pb-214
4 E−08
-
-
1 E+03
-
-
ET/ /
Bi-200
5 E−06
4 E−06
-
2 E+05
1 E+05
-
ET/ET/
Bi-201
3 E−06
2 E−06
-
1 E+05
1 E+05
-
ET/ET/
Bi-202
2 E−06
2 E−06
-
9 E+04
9 E+04
-
ET/ET/
Bi-203
7 E−07
7 E−07
-
2 E+04
2 E+04
-
ET/ET/
Bi-205
4 E−07
4 E−07
-
1 E+04
1 E+04
-
ET/ET/
Bi-206
2 E−07
2 E−07
-
9 E+03
8 E+03
-
ET/ET/
Bi-207
4 E−07
1 E−07
-
1 E+04
6 E+03
-
ET/St/
Bi-210m
3 E−09
2 E−10
-
1 E+02
9 E+00
-
K/St/
Bi-210
1 E−07
9 E−09
-
6 E+03
3 E+02
-
K/St/
Bi-212
1 E−08
8 E−09
-
4 E+02
3 E+02
-
ET/ET/
Bi-213
1 E−08
7 E−09
-
4 E+02
2 E+02
-
ET/ET/
Bi-214
1 E−08
1 E−08
-
6 E+02
4 E+02
-
ET/ET/
Po-203
5 E−06
4 E−06
-
1 E+05
1 E+05
-
ET/ET/
Po-205
4 E−06
3 E−06
-
1 E+05
1 E+05
-
ET/ET/
Po-207
1 E−06
1 E−06
-
7 E+04
6 E+04
-
ET/ET/
Po-210
7 E−10
2 E−10
-
2 E+01
9 E+00
-
K/St/
242 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
At-207
1 E−06
2 E−07
-
4 E+04
1 E+04
-
St/St/
At-211
7 E−09
5 E−09
-
2 E+02
1 E+02
-
ET/St/
Rn-2205
1 E−08
-
-
6 E+02
-
-
-
Rn-2225
8 E−08
-
-
3 E+03
-
-
-
Fr-222
1 E−08
-
-
3 E+02
-
-
ET/ /
Fr-223
4 E−07
-
-
1 E+04
-
-
St/ /
Ra-223
-
9 E−11
-
-
3 E+00
-
/St/
Ra-224
-
2 E−10
-
-
8 E+00
-
/St/
Ra-225
-
1 E−10
-
-
4 E+00
-
/St/
Ra-226
-
2 E−10
-
-
9 E+00
-
/St/
Ra-227
-
8 E−07
-
-
3 E+04
-
/BS/
Ra-228
-
1 E−10
-
-
5 E+00
-
/BS/
Ac-224
1 E−08
6 E−09
5 E−09
6 E+02
2 E+02
2 E+02
BS/St/St
Ac-225
2 E−10
9 E−11
8 E−11
7 E+00
3 E+00
3 E+00
BS/St/St
Ac-226
1 E−09
6 E−10
5 E−10
4 E+01
2 E+01
Section 174
2 E+01
ET/St/St
Ac-227
2 E−13
1 E−12
1 E−11
1 E−02
5 E−02
4 E−01
BS/BS/St
Ac-228
6 E−09
3 E−08
4 E−08
2 E+02
1 E+03
1 E+03
BS/BS/St
Th-226
-
4 E−09
4 E−09
-
1 E+02
1 E+02
/ET/ET
Th-227
-
9 E−11
7 E−11
-
3 E+00
2 E+00
/St/St
Th-228
-
2 E−11
2 E−11
-
7 E−01
8 E−01
/BS/St
Th-229
-
2 E−12
1 E−11
-
7 E−02
4 E−01
/BS/St
Th-230
-
3 E−12
4 E−11
-
1 E−01
1 E+00
/BS/BS
Th-231
-
1 E−06
1 E−06
-
5 E+04
5 E+04
/St/St
Th-232
-
3 E−12
4 E−11
-
1 E−01
1 E+00
/BS/BS
Th-234
-
1 E−07
9 E−08
-
3 E+03
3 E+03
/St/St
Pa-227
-
4 E−09
4 E−09
-
1 E+02
1 E+02
/ET/ET
DOE G 441.1-1C 243
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Pa-228
-
1 E−08
1 E−08
-
3 E+02
4 E+02
/BS/St
Pa-230
-
1 E−09
9 E−10
-
4 E+01
3 E+01
/St/St
Pa-231
-
1 E−12
1 E−11
-
4 E−02
4 E−01
/BS/BS
Pa-232
-
1 E−08
1 E−07
-
6 E+02
7 E+03
/BS/BS
Pa-233
-
2 E−07
1 E−07
-
7 E+03
6 E+03
/St/St
Pa-234
-
7 E−07
7 E−07
-
2 E+04
2 E+04
/ET/ET
U-230
6 E−10
5 E−11
4 E−11
2 E+01
2 E+00
1 E+00
K/St/St
U-231
2 E−06
1 E−06
1 E−06
8 E+04
4 E+04
4 E+04
ET/St/St
U-232
5 E−11
1 E−10
2 E−11
2 E+00
4 E+00
7 E−01
BS/St/ET
U-233
4 E−10
2 E−10
7 E−11
1 E+01
9 E+00
2 E+00
BS/St/ET
U-234
5 E−10
2 E−10
7 E−11
1 E+01
9 E+00
2 E+00
BS/St/ET
U-235
5 E−10
3 E−10
8 E−11
1 E+01
1 E+01
3 E+00
BS/St/ET
U-236
5 E−10
2 E−10
7 E−11
1 E+01
1 E+01
2 E+00
BS/St/ET
U-237
1 E−06
3 E−07
3 E−07
4 E+04
1 E+04
1 E+04
ET/St/St
U-238
5 E−10
3 E−10
8 E−11
2 E+01
1 E+01
3 E+00
BS/St/ET
U-239
1 E−05
9 E−06
9 E−06
5 E+05
3 E+05
3 E+05
ET/ET/ET
U-240
1 E−06
7 E−07
6 E−07
5 E+04
2 E+04
2 E+04
ET/St/St
Np-232
-
3 E−06
-
-
1 E+05
-
/BS/
Np-233
-
7 E−05
-
-
2 E+06
-
/ET/
Np-234
-
5 E−07
-
-
2 E+04
-
/ET/
Np-235
-
1 E−06
-
-
4 E+04
-
/BS/
Np-236 (1 E+05 yr)
-
4 E−11
-
-
1 E+00
-
/BS/
Np-236 (22 h)
-
5 E−08
-
-
1 E+03
-
/BS/
Np-237
-
8 E−12
-
-
3 E−01
-
/BS/
Np-238
-
1 E−07
-
-
4 E+03
-
/BS/
Np-239
-
5 E−07
-
-
1 E+04
-
/St/
244 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Np-240
-
2 E−06
-
-
8 E+04
-
/ET/
Pu-234
-
3 E−08
3 E−08
-
1 E+03
1 E+03
/St/St
Pu-235
-
9 E−05
8 E−05
-
3 E+06
3 E+06
/ET/ET
Pu-236
-
1 E−11
7 E−11
-
6 E−01
2 E+00
/BS/St
Pu-237
-
1 E−06
1 E−06
-
7 E+04
6 E+04
/St/St
Pu-238
-
6 E−12
5 E−11
-
2 E−01
1 E+00
/BS/St
Pu-239
-
5 E−12
6 E−11
-
2 E−01
2 E+00
/BS/BS
Pu-240
-
5 E−12
6 E−11
-
2 E−01
2 E+00
/BS/BS
Pu-241
-
2 E−10
2 E−09
-
1 E+01
1 E+02
/BS/BS
Pu-242
-
5 E−12
6 E−11
-
2 E−01
2 E+00
/BS/BS
Pu-243
-
5 E−06
5 E−06
-
1 E+05
1 E+05
/E/E
Pu-244
-
5 E−12
6 E−11
-
2 E−01
2 E+00
/BS/BS
Pu-245
-
9 E−07
8 E−07
-
3 E+04
3 E+04
/St/St
Pu-246
-
8 E−08
8 E−08
-
3 E+03
2 E+03
/St/St
Am-237
-
8 E−06
-
-
3 E+05
-
/ET/
Am-238
-
2 E−06
-
-
9 E+04
-
/BS/
Am-239
-
1 E−06
-
-
6 E+04
-
/ET/
Am-240
-
7 E−07
-
-
2 E+04
-
/ET/
Am-241
-
5 E−12
-
-
1 E−01
-
/BS/
Am-242m
-
5 E−12
-
-
1 E−01
-
/BS/
Am-242
-
4 E−08
-
-
1 E+03
-
/St/
Am-243
-
5 E−12
-
-
1 E−01
-
Section 175
/BS/
Am-244m
-
3 E−06
-
-
1 E+05
-
/BS/
Am-244
-
1 E−07
-
-
5 E+03
-
/BS/
Am-245
-
5 E−06
-
-
2 E+05
-
/ET/
Am-246m
-
6 E−06
-
-
2 E+05
-
/ET/
DOE G 441.1-1C 245
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Am-246
-
2 E−06
-
-
9 E+04
-
/ET/
Cm-238
-
1 E−07
-
-
4 E+03
-
/St/
Cm-240
-
2 E−10
-
-
7 E+00
-
/St/
Cm-241
-
2 E−08
-
-
8 E+02
-
/St/
Cm-242
-
1 E−10
-
-
5 E+00
-
/St/
Cm-243
-
7 E−12
-
-
2 E−01
-
/BS/
Cm-244
-
9 E−12
-
-
3 E−01
-
/BS/
Cm-245
-
5 E−12
-
-
1 E−01
-
/BS/
Cm-246
-
5 E−12
-
-
1 E−01
-
/BS/
Cm-247
-
5 E−12
-
-
2 E−01
-
/BS/
Cm-248
-
1 E−12
-
-
5 E−02
-
/BS/
Cm-249
-
8 E−06
-
-
3 E+05
-
/ET/
Cm-250
-
2 E−13
-
-
8 E−03
-
/BS/
Bk-245
-
3 E−07
-
-
1 E+04
-
/St/
Bk-246
-
8 E−07
-
-
3 E+04
-
/ET/
Bk-247
-
3 E−12
-
-
1 E−01
-
/BS/
Bk-249
-
1 E−09
-
-
5 E+01
-
/BS/
Bk-250
-
2 E−07
-
-
9 E+03
-
/BS/
Cf-244
-
1 E−08
-
-
5 E+02
-
/ET/
Cf-246
-
1 E−09
-
-
5 E+01
-
/St/
Cf-248
-
5 E−11
-
-
2 E+00
-
/BS/
Cf-249
-
3 E−12
-
-
1 E−01
-
/BS/
Cf-250
-
7 E−12
-
-
2 E−01
-
/BS/
Cf-251
-
3 E−12
-
-
1 E−01
-
/BS/
Cf-252
-
1 E−11
-
-
6 E−01
-
/BS/
Cf-253
-
5 E−10
-
-
2 E+01
-
/St/
246 DOE G 441.1-1C
5-19-08
Absorption Type3
Absorption Type3
µCi/mL
Bq/m3
Stochastic
or organ
or tissue1
Radionuclide
F
M
S
F
M
S
( F/ M/ S)
Cf-254
-
2 E−11
-
-
8 E−01
-
/BS/
Es-250
-
4 E−07
-
-
1 E+04
-
/BS/
Es-251
-
3 E−07
-
-
1 E+04
-
/St/
Es-253
-
2 E−10
-
-
9 E+00
-
/St/
Es-254m
-
1 E−09
-
-
5 E+01
-
/St/
Es-254
-
6 E−11
-
-
2 E+00
-
/BS/
Fm-252
-
2 E−09
-
-
8 E+01
-
/St/
Fm-253
-
1 E−09
-
-
6 E+01
-
/St/
Fm-254
-
6 E−09
-
-
2 E+02
-
/ET/
Fm-255
-
2 E−09
-
-
8 E+01
-
/St/
Fm-257
-
1 E−10
-
-
4 E+00
-
/St/
Md-257
-
2 E−08
-
-
1 E+03
-
/St/
Md-258
-
1 E−10
-
-
4 E+00
-
/St/
Footnotes for Appendix A
1 A determination of whether the DACs are controlled by stochastic (St) or deterministic (organ or tissue) dose, or if
they both give the same result (E), for each absorption type, is given in this column. The key to the organ notation for
deterministic dose is: BS = Bone surface, ET = Extra thoracic, K = Kidney, L = Liver, and T = Thyroid. A blank
indicates that no calculations were performed for the absorption type shown.
2 The ICRP identifies these materials as soluble or reactive gases and vapors or highly soluble or reactive gases and
vapors. For tritiated water, the inhalation DAC values allow for an additional 50% absorption through the skin, as
described in ICRP Publication No. 68, Dose Coefficients for Intakes of Radionuclides by Workers. For elemental
tritium, the DAC values include a factor that irradiation from gas within the lungs might increase the dose by 20%.
3 A dash indicates no values given for this data category.
4 DAC values derived using hafnium tritide particle and are based on “observed activity” (i.e., only radiation emitted
from the particle is considered). DAC values derived using methodology found in Radiological Control Programs for
Special Tritium Compounds, DOE-HDBK-1184-2004.
5 These values are appropriate for protection from radon combined with its short-lived decay products and are based on
information given in ICRP Publication 65: Protection Against Radon-222 at Home and at Work and in DOE-STD-1121-
98: Internal Dosimetry. The values given are for 100% equilibrium concentration conditions of the short-lived radon
decay products with the parent. To allow for an actual measured equilibrium concentration or a demonstrated equili-
brium concentration, the values given in this table should be multiplied by the ratio (100%/actual %) or
(100%/demonstrated %), respectively. Alternatively, the DAC values for Rn-220 and Rn-222 may be replaced by 2.5
working level (WL) and 0.83 WL, respectively, for appropriate limiting of decay product concentrations. A WL is any
combination of short-lived radon decay products, in one liter of air without regard to the degree of equilibrium, that will
result in the ultimate emission of 1.3 E+05 MeV of alpha energy.
Section 176
DOE G 441.1-1C 247 (and 248)
5-19-08
Appendix B
Reserved
DOE G 441.1-1C 249
5-19-08
Appendix C
Derived Air Concentration (DAC) For Workers From External Exposure During
Immersion In A Cloud Of Airborne Radioactive Material
a. The data presented in appendix C are to be used for controlling occupational
exposures in accordance with § 835.209, identifying the need for air monitoring in
accordance with § 835.403 and identifying the need for posting of airborne radioactivity
areas in accordance with § 835.603(d).
b. The air immersion DAC values shown in this appendix are based on a stochastic dose
limit of 5 rems (0.05 Sv) per year. Four columns of information are presented: (1)
radionuclide; (2) half-life in units of seconds (s), minutes (min), hours (h), days (d), or
years (yr); (3) air immersion DAC in units of µCi/mL; and (4) air immersion DAC in
units of Bq/m3. The data are listed by radionuclide in order of increasing atomic mass.
The air immersion DACs were calculated for a continuous, nonshielded exposure via
immersion in a semi-infinite cloud of airborne radioactive material. The DACs listed in
this appendix may be modified to allow for submersion in a cloud of finite dimensions.
c. The DAC values are given for individual radionuclides. For known mixtures of
radionuclides, determine the sum of the ratio of the observed concentration of a
particular radionuclide and its corresponding DAC for all radionuclides in the mixture.
If this sum exceeds unity (1), then the DAC has been exceeded. For unknown
radionuclides, the most restrictive DAC (lowest value) for those isotopes not known to
be absent shall be used.
Air Immersion DAC
Radionuclide
Half-Life
(µCi/mL)
(Bq/m3)
Ar-37
35.02 d
1 E+00
4 E+10
Ar-39
269 yr
4 E−04
1 E+07
Ar-41
1.827 h
1 E−06
3 E+04
Kr-74
11.5 min
1 E−06
4 E+04
Kr-76
14.8 h
3 E−06
1 E+05
Kr-77
74.7 h
1 E−06
5 E+04
Kr-79
35.04 h
5 E−06
2 E+05
Kr-81
2.1E+05 yr
2 E−04
9 E+06
Kr-83m
1.83 h
2 E−02
9 E+08
Kr-85
10.72 yr
2 E−04
9 E+06
250 DOE G 441.1-1C
5-19-08
Air Immersion DAC
Radionuclide
Half-Life
(µCi/mL)
(Bq/m3)
Kr-85m 4.48 h 9 E−06 3 E+05
Kr-87
76.3 min
1 E−06
5 E+04
Kr-88
2.84 h
6 E−07
2 E+04
Xe-120
40.0 min
3 E−06
1 E+05
Xe-121
40.1 min
7 E−07
2 E+04
Xe-122
20.1 h
2 E−05
1 E+06
Xe-123
2.14 h
2 E−06
8 E+04
Xe-125
16.8 h
5 E−06
2 E+05
Xe-127
36.406 d
5 E−06
2 E+05
Xe-129m
8.89 d
6 E−05
2 E+06
Xe-131m
11.84 d
1 E−04
6 E+06
Xe-133
5.245 d
4 E−05
1 E+06
Xe-133m
2.19 d
4 E−05
1 E+06
Xe-135
9.11 h
5 E−06
2 E+05
Xe-135m
15.36 min
3 E−06
1 E+05
Xe-138
14.13 min
1 E−06
4 E+04
For any single radionuclide not listed above with decay mode other than alpha emission or
spontaneous fission and with radioactive half-life less than two hours, the DAC value shall be 6
E−06 µCi/mL (2 E+04 Bq/m3).
DOE G 441.1-1C 251
5-19-08
Appendix D
Surface Contamination Values
The data presented in appendix D are to be used in identifying and posting contamination
and high contamination areas in accordance with § 835.603(e) and (f) and identifying the
need for surface contamination monitoring and control in accordance with § 835.1101
and 1102.
Surface Contamination Values1 in dpm/100 cm2
Radionuclide
Removable 2,4
Total
(Fixed +
Removable)2,3
U-nat, U-235, U-238, and associated decay
products
7 1,000
7 5,000
Section 177
Transuranics, Ra-226, Ra-228, Th-230,
Th-228, Pa-231, Ac-227, I-125, I-129
20
500
Th-nat, Th-232, Sr-90, Ra-223, Ra-224, U-
232, I-126, I-131, I-133
200
1,000
Beta-gamma emitters (nuclides with decay
modes other than alpha emission or
spontaneous fission) except Sr-90 and
others noted above5
1,000
5,000
Tritium and STCs 6
10,000
See Footnote 6
1 The values in this appendix, with the exception noted in footnote 6 below, apply to
radioactive contamination deposited on, but not incorporated into the interior or matrix
of, the contaminated item. Where surface contamination by both alpha- and beta-gamma-
emitting nuclides exists, the limits established for alpha- and beta-gamma-emitting
nuclides apply independently.
2 As used in this table, dpm (disintegrations per minute) means the rate of emission by
radioactive material as determined by correcting the counts per minute observed by an
appropriate detector for background, efficiency, and geometric factors associated with the
instrumentation.
3 The levels may be averaged over one square meter provided the maximum surface
activity in any area of 100 cm2 is less than three times the value specified. For purposes
of averaging, any square meter of surface shall be considered to be above the surface
contamination value if: (1) from measurements of a representative number of sections it
is determined that the average contamination level exceeds the applicable value; or (2) it
252 DOE G 441.1-1C
5-19-08
is determined that the sum of the activity of all isolated spots or particles in any 100 cm2
area exceeds three times the applicable value.
4 The amount of removable radioactive material per 100 cm2 of surface area should be
determined by swiping the area with dry filter or soft absorbent paper, applying moderate
pressure, and then assessing the amount of radioactive material on the swipe with an
appropriate instrument of known efficiency. (Note - The use of dry material may not be
appropriate for tritium.) When removable contamination on objects of surface area less
than 100 cm2 is determined, the activity per unit area shall be based on the actual area and
the entire surface shall be wiped. It is not necessary to use swiping techniques to measure
removable contamination levels if direct scan surveys indicate that the total residual
surface contamination levels are within the limits for removable contamination.
5 This category of radionuclides includes mixed fission products, including the Sr-90
which is present in them. It does not apply to Sr-90 which has been separated from the
other fission products or mixtures where the Sr-90 has been enriched.
6 Tritium contamination may diffuse into the volume or matrix of materials. Evaluation of
surface contamination shall consider the extent to which such contamination may migrate
to the surface in order to ensure the surface contamination value provided in this
appendix is not exceeded. Once this contamination migrates to the surface, it may be
removable, not fixed; therefore, a "Total" value does not apply. In certain cases, a “Total”
value of 10,000 dpm/100 cm2 may be applicable either to metals of the types from which
insoluble special tritium compounds are formed, that have been exposed to tritium, or to
bulk materials to which insoluble special tritium compound particles are fixed to a
surface.
7 These limits apply only to the alpha emitters within the respective decay series.
DOE G 441.1-1C 253
5-19-08
Appendix E
Section 178
Values For Establishing Sealed Radioactive Source Accountability And Radioactive
Material Posting And Labeling Requirements
The data presented in appendix E are to be used for identifying accountable sealed
radioactive sources and radioactive material areas as those terms are defined at §
835.2(a), establishing the need for radioactive material area posting in accordance with
§ 835.603(g), and establishing the need for radioactive material labeling in accordance
with § 835.605.
Nuclide
Activity (µCi)
H-3 1.5E+08
Be-7 3.1E+03
Be-10 1.4E+05
C-14 4.6E+06
Na-22 1.9E+01
Al-26 1.5E+01
Si-32 4.9E+04
S-35 2.4E+06
Cl-36 5.2E+05
K-40 2.7E+02
Ca-41 9.3E+06
Ca-45 1.1E+06
Sc-46 6.2E+01
Ti-44 1.5E+02
V-49 1.0E+08
Mn-53 7.5E+07
Mn-54 6.5E+01
Fe-55 2.9E+06
Fe-59 1.9E+02
Fe-60 8.1E+03
Co-56 3.9E+01
Co-57 2.3E+02
Co-58 1.3E+02
Co-60 1.7E+01
Ni-59 3.2E+06
Ni-63 1.3E+06
Zn-65 1.1E+02
Ge-68 5.6E+02
As-73 5.3E+02
Se-75 6.3E+01
Se-79 8.7E+05
Rb-83 9.1E+01
Rb-84 2.0E+02
Sr-85 1.2E+02
Sr-89 4.8E+05
Sr-90 3.5E+04
Y-88 3.3E+01
Nuclide
Activity (µCi)
Y-91 5.0E+04
Zr-88 1.1E+02
Zr-93 9.3E+04
Zr-95 1.9E+02
Nb-91 6.9E+01
Nb-91m 3.6E+02
Nb-92 1.8E+01
Nb-93m 4.4E+02
Nb-94 2.3E+01
Nb-95 3.4E+02
Mo-93 7.7E+01
Tc-95m 1.3E+02
Tc-97 8.1E+01
Tc-97m 3.5E+02
Tc-98 2.5E+01
Tc-99 8.4E+05
Ru-103 4.4E+02
Ru-106 2.5E+02
Rh-101 8.7E+05
Rh-102 3.0E+05
Rh-102m 6.4E+05
Pd-107 9.3E+06
Ag-105 3.3E+06
Ag-108m 1.8E+01
Ag-110m 2.2E+01
Cd-109 1.6E+02
Cd-113m 2.0E+04
Cd-115m 1.0E+04
In-114m 7.7E+02
Sn-113
3.1E+02
Sn-119m 3.3E+02
Sn-121m 8.1E+05
Sn-123 1.3E+04
Sn-126 1.8E+02
Sb-124 9.1E+01
Sb-125 6.7E+01
Te-121m 1.8E+02
254 DOE G 441.1-1C
5-19-08
Nuclide
Activity (µCi)
Te-123m 2.8E+02
Te-125m 4.4E+02
Te-127m 8.0E+02
Te-129m 2.3E+03
I-125 3.5E+02
I-129 1.8E+02
Cs-134 2.6E+01
Cs-135 1.3E+06
Cs-137 6.0E+01
Ba-133 5.1E+01
La-137 2.7E+05
Ce-139 2.4E+02
Ce-141 2.4E+03
Ce-144 1.4E+03
Pm-143 1.3E+02
Pm-144 2.9E+01
Pm-145 2.6E+02
Pm-146 4.4E+01
Pm-147 7.7E+05
Pm-148m 1.0E+02
Sm-145 2.4E+06
Sm-146 4.0E+02
Sm-151 2.5E+05
Eu-148 1.1E+06
Eu-149 1.1E+07
Eu-152 3.1E+01
Eu-154 3.1E+01
Eu-155
3.6E+02
Gd-146 5.1E+05
Gd-148 9.0E+01
Gd-151 2.9E+06
Gd-153 2.1E+02
Tb-157 2.5E+03
Tb-158 9.0E+04
Tb-160 1.2E+02
Dy-159 1.0E+07
Ho-166m 2.1E+01
Tm-170 8.4E+03
Tm-171 2.8E+04
Yb-169 5.5E+02
Lu-173 1.8E+06
Lu-174 9.3E+05
Lu-174m 1.0E+06
Lu-177m 5.8E+01
Hf-172 7.3E+04
Hf-175 3.0E+06
Hf-178m 8.7E+03
Hf-181 3.4E+02
Hf-182 7.5E+03
Ta-179 9.3E+06
Nuclide
Activity (µCi)
Ta-182 7.3E+01
W-181 1.0E+03
W-185 3.9E+06
W-188 6.3E+04
Re-183 5.3E+02
Re-184 2.6E+02
Re-184m 1.5E+02
Re-186m 3.4E+05
Os-185 1.3E+02
Os-194 6.4E+04
Ir-192 1.3E+02
Ir-192m 1.4E+05
Ir-194m 2.7E+01
Pt-193 8.7E+07
Au-195 4.8E+02
Hg-194 5.2E+04
Hg-203 4.9E+02
Tl-204 2.2E+04
Pb-202 1.9E+05
Pb-205 9.0E+01
Pb-210 9.2E+01
Bi-207 1.7E+01
Bi-208 1.5E+01
Bi-210m 1.2E+03
Po-209 6.3E+03
Po-210 1.2E+03
Ra-226 2.2E+02
Ra-228 1.5E+03
Ac-227 4.2E+00
Th-228 8.4E+01
Th-229 3.1E+01
Th-230 5.4E+00
Th-232 9.3E+01
Pa-231 3.0E+01
U-232 1.0E+02
U-233 3.9E+02
U-234 2.9E+02
U-235 6.7E+01
U-236 3.1E+02
U-238 3.5E+02
Np-235 1.1E+02
Np-236 2.1E+01
Np-237 4.9E+01
Pu-236 2.0E+02
Pu-237 3.3E+02
Pu-238 9.0E+01
Pu-239 8.4E+01
Pu-240 8.4E+01
Pu-241 4.6E+03
Pu-242 8.7E+01
DOE G 441.1-1C 255
5-19-08
Nuclide
Activity (µCi)
Pu-244 9.0E+01
Am-241 7.2E+01
Am-242m 1.1E+02
Am-243 7.3E+01
Cm-241 1.0E+05
Cm-242 6.2E+02
Cm-243 4.8E+01
Cm-244 1.5E+02
Cm-245 5.0E+01
Cm-246 1.0E+02
Cm-247 8.5E+01
Cm-248 2.8E+01
Cm-250 5.4E+00
Nuclide
Activity (µCi)
Section 179
Bk-247 6.0E+01
Bk-249 2.7E+04
Cf-248 4.4E+02
Cf-249 5.5E+01
Cf-250 1.2E+02
Cf-251 5.3E+01
Cf-252 5.2E+00
Cf-254 1.2E+02
Es-254 6.3E+01
Es-255 8.8E+03
Fm-257 5.1E+02
Md-258 6.1E+02
Any alpha emitting radionuclide not listed in appendix E and mixtures of alpha emitters of
unknown composition have a value of 10 µCi.
With the exception that any type of STC has a value of 10 Ci, any radionuclide other than alpha
emitting radionuclides not listed in appendix E and mixtures of beta emitters of unknown
composition have a value of 100 µCi. DOE DOE-HDBK-1184-2004, RADIOLOGICAL
CONTROL PROGRAMS FOR SPECIAL TRITIUM COMPOUNDS (DOE 2004d), provides
guidance for radiological controls, including monitoring, for special tritium compounds.
Note: Where there is involved a combination of radionuclides in known amounts, derive the
value for the combination as follows: determine, for each radionuclide in the combination, the
ratio between the quantity present in the combination and the value otherwise established for the
specific radionuclide when not in combination. If the sum of such ratios for all radionuclides in
the combination exceeds unity (1), then the accountability criterion has been exceeded.
The values in the above table were derived based on the quantity of radioactive material which
results in either an external or internal whole body dose, from either inhalation or ingestion, of
100 millirems. The external exposure scenario assumed a photon exposure for 12 hours a day for
365 days with the source distance being at 1 meter, with the exception for Californium-252,
which was obtained by substituting a neutron exposure for the photon exposure in the external
exposure scenario using values from Reference Neutron Radiations – Part 1: Characteristics and
Methods of Production, ISO/CD, 8529-1. The internal exposure scenario assumed an
instantaneous intake of 0.001% of the material by an individual. The scenario which resulted in a
lower quantity of radioactive material was chosen.
DOE G 441.1-1C 257
5-19-08
Appendix F
Radiation Weighting Factors
The below table is taken from the “Definitions” section of 10 CFR 835 and is provided for
information purposes. There is no corresponding Appendix F in 10 CFR 835.
RADIATION WEIGHTING FACTORS1, wR
Type and energy range
Radiation weighting factor
Photons, electrons and muons, all energies
1
Neutrons, energy < 10 keV2, 3
5
Neutrons, energy 10 keV to 100 keV2, 3
10
Neutrons, energy > 100 keV to 2 MeV2, 3
20
Neutrons, energy > 2 MeV to 20 MeV2, 3
10
Neutrons, energy > 20 MeV2, 3
5
Protons, other than recoil protons, energy > 2
MeV
5
Alpha particles, fission fragments, heavy
nuclei
20
1. All values relate to the radiation incident on the body or, for internal sources, emitted
from the source.
2. When spectral data are insufficient to identify the energy of the neutrons, a radiation
weighting factor of 20 shall be used.
3. When spectral data are sufficient to identify the energy of the neutrons, the following
equation may be used to determine a neutron radiation weighting factor value:
wR = 5 + 17 exp ⎥
⎦
⎤
⎢
⎣
⎡−
6
))2(ln( 2
nE
Where En is the neutron energy in MeV.
258 DOE G 441.1-1C
5-19-08
Appendix G
Tissue Weighting Factors
The below table is taken from the “Definitions” section of 10 CFR 835 and is provided for
information purposes. There is no corresponding Appendix G in 10 CFR 835.
TISSUE WEIGHTING FACTORS FOR VARIOUS ORGANS AND TISSUES
Organs or tissues, T
Tissue weighting
Section 180
factor, wT
Gonads
0.20
Red bone marrow
0.12
Colon
0.12
Lungs
0.12
Stomach
0.12
Bladder
0.05
Breast
0.05
Liver
0.05
Esophagus
0.05
Thyroid
0.05
Skin
0.01
Bone surfaces
0.01
Remainder1
0.05
Whole body2
1.00
1 "Remainder" means the following additional tissues and organs and their masses, in grams,
following parenthetically: adrenals (14), brain (1400), extrathoracic airways (15), small
intestine (640), kidneys (310), muscle (28,000), pancreas (100), spleen (180), thymus (20),
and uterus (80). The equivalent dose to the remainder tissues (Hremainder), is normally
calculated as the mass-weighted mean dose to the preceding ten organs and tissues. In those
cases in which the most highly irradiated remainder tissue or organ receives the highest
equivalent dose of all the organs, a weighting factor of 0.025 (half of remainder) is applied to
that tissue or organ and 0.025 (half of remainder) to the mass-weighted equivalent dose in the
rest of the remainder tissues and organs to give the remainder equivalent dose.
2 For the case of uniform external irradiation of the whole body, a tissue weighting factor
(wT) equal to 1 may be used in determination of the effective dose.
DOE G 441.1-1C 259
5-19-08
REFERENCES
(AEC1954) Atomic Energy Commission 1954. U.S. Atomic Energy Act of 1954, as
amended. Public Law 83-703 (68 Stat. 919), Title 42 U.S.C., Section 2011.
(ANSI 1979) American National Standards Institute 1979. ANSI N320, American National
Standard Performance Specifications for Reactor Emergency Radiological Monitoring
Instrumentation, New York, NY.
(ANSI 1988) American National Standards Institute 1988. ANSI N13.3, Dosimetry for
Criticality Accidents. McClean, VA.
(ANSI 1993) American National Standards Institute 1993. ANSI N43.3-1993, General
Radiation Safety -Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources,
Energies up to 10 MeV. New York, NY.
(ANSI 1997a) American National Standards Institute 1997. ANSI N323A-1997, American
National Standard Radiation Protection Instrumentation Test and Calibration, Portable
Survey Instruments. New York, NY.
(ANSI 1997b) American National Standards Institute 1997. ANSI N322, American National
Standard Inspection, Test, Construction, and Performance Requirements for Direct Reading
Electrostatic/Electroscope Type Dosimeters, New York, NY.
(ANSI 1989a) American National Standards Institute 1989. ANSI N13.5-R1989, American
National Standard Performance Specifications for Direct Reading and Indirect Reading
Pocket Dosimeters. New York, NY.
(ANSI 1989b) American National Standards Institute 1989. ANSI N42.17A-1989,
Performance Specifications for Health Physics Instrumentation - Portable Instrumentation
for Use in Normal Environmental Conditions. New York, NY.
(ANSI 1989c) American National Standards Institute 1989. ANSI N42.17C-1989,
Performance Specifications for Health Physics Instrumentation - Portable Instrumentation
for Use in Extreme Environmental Conditions. New York, NY.
(ANSI 1989d) American National Standards Institute 1989. ANSI N42.17B, Performance
Specifications for Health Physics Instrumentation - Occupational Airborne Radioactivity
Monitoring Instrumentation. New York, NY.
(ANSI 1989e) American National Standards Institute 1989. ANSI N2.1-1971(R1989),
Radiation Symbol. New York, NY.
(ANSI 1992a) American National Standards Institute 1992. ANSI N13.27, Performance
Specifications for Pocket-sized Alarming Dosimeter/Ratemeters. New York, NY.
(ANSI 1992b) American National Standards Institute 1992. ANSI Z88.2-1992, Practices for
Respiratory Protection. New York, NY.
Section 181
260 DOE G 441.1-1C
5-19-08
(ANSI/HPS 1996) American National Standards Institute/Health Physics Society 1996.
ANSI/HPS N13.30-1996, Performance Criteria for Radiobioassay. McLean, VA .
(ANSI/HPS 1997a) American National Standards Institute/Health Physics Society 1997.
ANSI/HPS N13.41-1997, Criteria for Performing Multiple Dosimetry. McClean, VA.
(ANSI/HPS 1997b) American National Standards Institute/Health Physics Society 1997.
ANSI/HPS N43.6-1997, Sealed Radioactive Sources Classification. Mclean, VA.
(ANSI/HPS 1999) American National Standards Institute/Health Physics Society 1999.
ANSI /HPS N13.6-1999, Practice for Occupational Radiation Exposure Records Systems.
McClean, VA.
(ANSI/HPS 2000) American National Standards Institute/Health Physics Society 2000.
ANSI/HPS N13.39-2000, American National Standard for Design of Internal Dosimetry
Programs. McLean, VA.
(ANSI/HPS 2001a) American National Standards Institute/Health Physics Society 2001.
ANSI/HPS N43.2-2001, Radiation Safety for X-Ray Diffraction and Fluorescence Analysis
Equipment. McClean, VA.
(ANSI/HPS 2001b) American National Standards Institute/Health Physics Society 2001.
ANSI/HPS N13.49-2001, Performance and Documentation of Radiological Surveys.
McClean, VA.
(ANSI/HPS 2005) American National Standards Institute/Health Physics Society 2005.
ANSI/HPS N43.5-2005, Radiological Safety Standard for the Design of Radiographic and
Fluoroscopic Industrial X-Ray Equipment. McClean, VA.
(ANSI/NCSL 1994) American National Standards Institute/National Conference of
Standards Laboratories 1994. ANSI/NCSL Z540-1-1994, American National Standard for
Calibration - Calibration Laboratories and Measuring and Test Equipment -General
Requirements, Boulder, Colorado.
(BRH 1970) Bureau of Radiological Health. Radiological Health Handbook, U.S.
Government Printing Office. Washington, D.C.
(DOE 1993a) DOE O 5400.5, Ch. 2, Radiation Protection of the Public and the
Environment, U.S. Department of Energy. Washington, D.C.
(DOE 1993b) DOE O 5480.30, Ch 1, Nuclear Reactor Safety Design Criteria, U.S.
Department of Energy. Washington, D.C.
(DOE 1994) DOE-STD-1070-94, GUIDELINES FOR EVALUATION OF NUCLEAR
FACILITY TRAINING PROGRAMS, U.S. Department of Energy. Washington, D.C
(DOE 1996) DOE P 441.1, Department of Energy Radiological Health and Safety Policy,
U.S. Department of Energy. Washington, D.C.
DOE G 441.1-1C 261
5-19-08
(DOE 1997a) DOE-STD-1107-97, KNOWLEDGE, SKILLS, AND ABILITIES FOR KEY
RADIATION PROTECTION POSITIONS AT DOE FACILITIES, U.S. Department of
Energy. Washington, D.C. (Use the revised version, reflecting the 2007 amendment to 10
CFR 835, when available.)
(DOE 1997b) DOE-HDBK-1106-97, RADIOLOGICAL CONTAMINATION CONTROL
TRAINING FOR LABORATORY RESEARCH, U.S. Department of Energy. Washington,
D.C. (Use the revised version, reflecting the 2007 amendment to 10 CFR 835, when
available.)
(DOE 1997c) DOE-HDBK-1109-97, RADIOLOGICAL SAFETY TRAINING FOR
RADIATION-PRODUCING (X-RAY) DEVICES, U.S. Department of Energy. Washington,
D.C. (Use the revised version, reflecting the 2007 amendment to 10 CFR 835, when
available.)
(DOE 1998a) DOE-STD-1111-98, DEPARTMENT OF ENERGY LABORATORY
ACCREDITATION PROGRAM ADMINISTRATION, U.S. Department of Energy.
Washington, D.C. (Use the revised version, reflecting the 2007 amendment to 10 CFR 835,
when available.)
(DOE 1998b) DOE-STD-1112-98. DEPARTMENT OF ENERGY LABORATORY
ACCREDITATION PROGRAM FOR RADIOBIOASSAY, U.S. Department of Energy.
Washington, D.C. (Use the revised version, reflecting the 2007 amendment to 10 CFR 835,
when available.)
Section 182
(DOE 1998c) DOE-HDBK-1113-98, RADIOLOGICAL SAFETY TRAINING FOR
URANIUM FACILITIES, U.S. Department of Energy. Washington, D.C. (Use the revised
version, reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 1999a) DOE-STD-1098-99, RADIOLOGICAL CONTROL, U.S. Department of
Energy. Washington, D.C. (Use the revised version, reflecting the 2007 amendment to 10
CFR 835, when available.)
(DOE 1999b) DOE-HDBK-1122-99 RADIOLOGICAL CONTROL TECHNICIAN
TRAINING, U.S. Department of Energy. Washington, D.C. (Use the revised version,
reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 2001a) 10 CFR 830 Subpart A, U.S. Department of Energy, Quality Assurance
Requirements. 66 FR 1810, Federal Register, Vol. 66, No. 7, dated 1-10-2001. Washington,
D.C.
(DOE 2001b) DOE O 5480.20A. Ch. 1, Personnel Selection, Qualification, and Training
Requirements for DOE Nuclear Facilities. U.S. Department of Energy. Washington, D.C.
(DOE 2001c) DOE-HDBK-1143-2001, RADIOLOGICAL CONTROL TRAINING FOR
SUPERVISORS, U.S. Department of Energy. Washington, D.C. (Use the revised version,
reflecting the 2007 amendment to 10 CFR 835, when available.)
262 DOE G 441.1-1C
5-19-08
(DOE 2001d) DOE-HDBK-1145-2001, RADIOLOGICAL SAFETY TRAINING FOR
PLUTONIUM FACILITIES, U.S. Department of Energy. Washington, D.C. (Use the revised
version, reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 2001e) DOE-HDBK-1141-2001, RADIOLOGICAL ASSESSOR TRAINING, U.S.
Department of Energy. Washington, D.C. (Use the revised version, reflecting the 2007
amendment to 10 CFR 835, when available.)
(DOE 2001f) DOE O 435.1, Ch.1, Radioactive Waste Management. U.S. Department of
Energy. Washington, D.C.
(DOE 2002a) DOE-HDBK-2002, RADIOLOGICAL SAFETY TRAINING FOR TRITIUM
FACILITIES, U.S. Department of Energy. Washington, D.C. (Use the revised version,
reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 2002b) DOE-HDBK-1108-2002, RADIOLOGICAL SAFETY TRAINING FOR
ACCELERATOR FACILITIES, U.S. Department of Energy. Washington, D.C. (Use the
revised version, reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 2003) DOE-STD-1121-2003, INTERNAL DOSIMETRY, U.S. Department of
Energy. Washington, D.C. (Use the revised version, reflecting the 2007 amendment to 10
CFR 835, when available.)
(DOE 2004a) DOE O 420.2B, Safety of Accelerator Facilities, U.S. Department of Energy.
Washington, D.C.
(DOE 2004b) DOE O 231.1A, Ch.1. Environment, Safety and Health Reporting, U.S.
Department of Energy. Washington, D.C.
(DOE 2004c) DOE M 231.1-1A, Ch. 1, Environment, Safety and Health Reporting Manual,
U.S. Department of Energy. Washington, D.C.
(DOE 2004d) DOE DOE-HDBK-1184-2004, RADIOLOGICAL CONTROL PROGRAMS
FOR SPECIAL TRITIUM COMPOUNDS, U.S. Department of Energy. Washington, D.C.
(Use the revised version, reflecting the 2007 amendment to 10 CFR 835, when available.)
(DOE 2005a) DOE O 414.1C, Quality Assurance, U.S. Department of Energy. Washington,
D.C.
(DOE 2005b) DOE O 226.1, Implementation of Department of Energy Oversight Policy,
U.S. Department of Energy. Washington, D.C.
(DOE 2005c) DOE O 151.1C, Comprehensive Emergency Management System, U.S.
Department of Energy. Washington, D.C.
(DOE 2005d) DOE O 420.1B, Facility Safety, U.S. Department of Energy. Washington,
D.C.
DOE G 441.1-1C 263
5-19-08
(DOE 2006a) DOE M 251.1-1B, Departmental Directives Program Manual, U.S.
Department of Energy, Washington, D.C.
Section 183
(DOE 2006b) DOE O 413.3A, Program and Project Management for the Acquisition of
Capital Assets, U.S. Department of Energy, Washington, D.C.
(DOE 2006c) 10 CFR 851, U.S. Department of Energy, Worker Safety and Health Program.
Federal Register, Vol. 71, No. 27, dated 02-09-2006. Washington, D.C.
(DOE 2006d) DOE G 440.1-8, Implementation Guide for Use with Title 10 code of Federal
Regulations Part 851, Worker Safety and Health Program, U.S. Department of Energy.
Washington, D.C.
(DOE 2007a) 10 CFR 835, U.S. Department of Energy. Occupational Radiation Protection.
Federal Register, Vol. 72, No. 110, dated 06-10-2007. Washington, D.C.
(DOE 2007b) 10 CFR 820, U. S. Department of Energy, Procedural Rules for DOE Nuclear
Activities, Vol. 72, No. 110, dated 06-10-2007. Washington, D.C.
(DOE 2007c) DOE O 440.1B, Worker Protection Program for DOE (Including the National
Nuclear Security Administration) Federal Employees, U.S. Department of Energy.
Washington, D.C.
(DOE 2007d) DOE-HDBK-1129-2007, TRITIUM HANDLING AND SAFE STORAGE,
U.S. Department of Energy. Washington, D.C.
(DOE 2007e) DOE-HDBK-1130-2007, RADIOLOGICAL WORKER TRAINING, U.S.
Department of Energy. Washington, D.C.
(DOE 20007f) DOE-HDBK-1131-2007, GENERAL EMPLOYEE RADIOLOGICAL
TRAINING, U.S. Department of Energy. Washington, D.C.
(DOE 2008) DOE-HDBK-1110-2008, ALARA TRAINING FOR TECHNICAL SUPPORT
PERSONNEL, U.S. Department of Energy. Washington, D.C.
(EPA 1987) U.S. Environmental Protection Agency 1987. Radiation Protection Guidance to
Federal Agencies for Occupational Exposure. 52 FR 2822, Federal Register, Vol. 52, No.
17. Washington, D.C.
(FOIA 1986) Freedom of Information Act 1986. Public Law 99-570, Title 5 U.S.C. sec. 552.
(ICRP 1977) International Commission on Radiological Protection 1977. ICRP Publication
26, Recommendation of the International Commission on Radiological Protection, Pergamon
Press. New York, New York.
264 DOE G 441.1-1C
5-19-08
(ICRP 1979) International Commission on Radiological Protection 1979. ICRP Publication
30, Limits for Intakes of Radionuclides by Workers: Design and Interpretation, Pergamon
Press. New York, New York.
(ICRP 1982) International Commission on Radiological Protection 1982. ICRP Publication
37, Cost-Benefit Analysis in the Optimization of Radiation Protection, Pergamon Press. New
York, New York.
(ICRP 1990) International Commission on Radiological Protection 1990. ICRP Publication
55, Optimization and Decision-Making in Radiological Protection, Pergamon Press. New
York, New York.
(ICRP 1991) International Commission on Radiological Protection 1991. ICRP Publication
60, 1990 Recommendations of the ICRP on Radiological Protection, Pergamon Press. New
York, New York.
(ICRP 1995) International Commission on Radiological Protection 1995. ICRP Publication
68, Dose Coefficients for Intakes of Radionuclides by Workers, Pergamon Press. New York,
New York.
(ICRP 1996) International Commission on Radiological Protection 1996. ICRP Publication
74, Conversion Coefficients for Use in Radiological Protection Against External Radiation,
Pergamon Press. New York, New York.
(ICRP 1998) International Commission on Radiological Protection 1998. ICRP Publication
88, Doses to the Embryo and Fetus from Intakes of Radionuclides by the Mother, Pergamon
Press. New York, New York.
(ICRU 1988) International Commission on Radiation Units and Measurements 1988. ICRU
Report No. 43, Determination of Dose Equivalents from External Radiation Sources - Part 2.
Bethesda, MD.
Section 184
(ISO 1977) International Organization for Standardization 1977. ISO 1677, Sealed
Radioactive Sources - General. Geneva, Switzerland.
(ISO 1990) International Organization for Standardization 1990. Draft International Standard
ISO/DIS 9978, Radiation Protection Sealed Radioactive Sources Leakage Test Methods.
Geneva, Switzerland.
(NCRP 1972) National Council on Radiation Protection and Measurements 1972. NCRP
Report No. 40, Protection Against Radiation from Brachytherapy Sources. Bethesda,
Maryland.
(NCRP 1980) National Council on Radiation Protection and Measurements 1980. NCRP
Report No. 65, Management of Persons Accidentally Contaminated with Radionuclides.
Bethesda, Maryland.
DOE G 441.1-1C 265
5-19-08
(NCRP 1985) National Council on Radiation Protection and Measurements 1985. NCRP
Report No. 84.,General Concepts for the Dosimetry of Internally Deposited Radionuclides.
Bethesda, Maryland.
(NCRP 1987a) National Council on Radiation Protection and Measurements 1987. NCRP
Report No. 87, Use of Radiobioassay Procedures for Assessment of Internal Radionuclide
Deposition. Bethesda, Maryland.
(NCRP 1987b) National Council on Radiation Protection and Measurements 1987. NCRP
Report No. 91, Recommendations on Limits for Exposure to Ionizing Radiation. Bethesda,
MD.
(NCRP 1989) National Council on Radiation Protection and Measurements 1989. NCRP
Report No. 106, Limit for Exposure to "Hot Particles" on the Skin. Bethesda, MD.
(NCRP 1992) National Council on Radiation Protection and Measurements 1992. NCRP
Report No. 114, dated 11-30-92, Maintaining Radiation Protection Records. Bethesda, MD
(NCRP 1993) National Council on Radiation Protection and Measurements 1993. NCRP
Report No. 116, Limitation of Exposure to Ionizing Radiation. Washington, D.C.
(NCSL 1989) National Conference of Standards Laboratories 1989. Recommended Practice
RP-1, Establishment and Adjustment of Calibration Intervals. Boulder, Colorado.
(NRC 1987) U.S. Nuclear Regulatory Commission 1987. Regulatory Guide 8.13, Instruction
Concerning Prenatal Radiation Exposure. Washington, D.C.
(NRC 1992) U.S. Nuclear Regulatory Commission 1992. 10 CFR 34, Licenses for
Radiography and Radiation Safety Requirements for Radiographic Operations. Washington,
D.C.
(NRC 1993) U.S. Nuclear Regulatory Commission 1993. NUREG-1400, Rev. 1, Air
Sampling in the Workplace. Washington, D.C.
(NRC 1998) U.S. Nuclear Regulatory Commission 1998. NUREG-1556, Volume 11,
Consolidated Guidance About Materials Licenses. . Washington, D.C.
(OSHA 174) Occupational Safety and Health Administration 1974. Occupational Safety and
Health Standards, 29 CFR 1910, 39 FR 23502. Washington, D.C.
(PA 1974) Privacy Act 1974. Privacy Act of 1974, as amended, Public Law 93-579, Title 5
U.S.C. sec. 552a.
(PNL 1987) Pacific Northwest Laboratory 1987. PNL-6301, Neutron Dose and Energy
Spectra Measurements at Savannah River Plant, Richland, WA.
266 DOE G 441.1-1C
5-19-08
(PNL 1988a) Pacific Northwest Laboratory 1988. PNL-6577, Health Physics Manual of
Good Practices for Reducing Radiation Exposure to As Low As Reasonably Achievable
(ALARA), Richland, WA.
(PNL 1988b) Pacific Northwest Laboratory 1988. PNL-6620, Personnel Neutron Dose
Assessment Upgrade, Richland, WA.
(USLW 1991) United States Law Week. United Automobile Workers v. Johnson Controls,
Inc. 499 U.S. 187, 206 (1991).